Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microspheres”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

SiOC coatings on yttria stabilized zirconia microspheres using a fluidized bed coating process

In this study, defect-free SiOC coatings were prepared on yttria stabilized zirconia (YSZ) microspheres by a fluidized bed coating process. Effects of the rheological properties of the coating solution on the coating process were elucidated. An impact regime diagram was constructed, which demonstrated that the coating mechanisms were collision/impact. During the fluidized bed coating, longer spouted time resulted in wider dispersion, longer residence time, and more circulatory motion of particles; the fluid distributed more uniformly throughout the column, as demonstrated in our Multiphase Flow with Interface eXchange (MFiX) simulations. Two-step pyrolysis in Ar achieved complete coating layers, which were comprised of SiOC, SiO 2 , SiC, and graphite. The two stage mass loss during the pyrolysis corresponded to simultaneous reactions due to depolymerization and hydrocarbon loss from 400 to 600°C. Carbon cluster size in the pyrolyzed samples was calculated to be 25 ± 2 Å. In conclusion, this work provides a new method for producing SiOC coatings on micron spheres, with nuclear TRISO fuel particles as the application.

42 ENGINEERING↗

Upcycling : converting waste plastics into paramagnetic, conducting, solid, pure carbon microspheres.

The recent tremendous increase in the volume of waste plastics (WP) will have a harmful environmental impact on the health of living beings. Hundreds of years are required to degrade WP in atmospheric conditions. Hence, in coming years, in addition to traditional recycling services, innovative 'upcycling' processes are necessary. This article presents an environmentally benign, solvent-free autogenic process that converts various WP [low density polyethylene (LDPE), high density polyethylene (HDPE), polyethylene terephthalate (PET), polystyrene (PS), or their mixtures] into carbon microspheres (CMSs), an industrially significant, value-added product. The thermal dissociation of these individual or mixed WP in a closed reactor under autogenic pressure (1000 psi) produced dry, pure powder of CMSs. In this paper, the optimization of process parameters such as the effect of mixing of WP with other materials, and the role of reaction temperature and time are reported. Employing advanced analytical techniques, the atomic structure, composition, and morphology of as-obtained CMSs were analyzed. The room-temperature paramagnetism in CMSs prepared from waste LDPE, HDPE, and PS was further studied by electron paramagnetic resonance (EPR). The conducting and paramagnetic nature of CMSs holds promise for their potential applications in toners, printers, paints, batteries, lubricants, and tires.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microspherical photonics: Sorting resonant photonic atoms by using light

A method of sorting microspheres by resonant light forces in vacuum, air, or liquid is proposed. Based on a two-dimensional model, it is shown that the sorting can be realized by allowing spherical particles to traverse a focused beam. Under resonance with the whispering gallery modes, the particles acquire significant velocity along the beam direction. This opens a unique way of large-volume sorting of nearly identical photonic atoms with 1/Q accuracy, where Q is the resonance quality factor. This is an enabling technology for developing super-low-loss coupled-cavity structures and devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging of sub-wavelength structures radiating coherently near microspheres

Using a two-dimensional model, we show that the optical images of a sub-wavelength object depend strongly on the excitation of its electromagnetic modes. There exist modes that enable the resolution of the object features smaller than the classical diffraction limit, in particular, due to the destructive interference. We propose to use such modes for super-resolution of resonant structures such as coupled cavities, metal dimers, or bowties. A dielectric microsphere in contact with the object forms its magnified image in a wide range of the virtual image plane positions. It is also suggested that the resonances may significantly affect the resolution quantification in recent experimental studies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Size dependence of second-harmonic generation at the surface of microspheres

The resonance-enhanced surface second-harmonic generation (SHG) from a suspension of polystyrene microspheres was investigated as a function of particle size in a range of the order of the fundamental wavelength for two different second-harmonic-enhancing dyes--malachite green and pyridine 1. The two dyes gave the same strongly modulated pattern of the forward second-harmonic scattering efficiency. Direct comparison to the nonlinear Rayleigh-Gans-Debye (NLRGD) and nonlinear Wentzel-Kramers-Brillouin (NLWKB) model predictions showed that the NLWKB model reproduces the overall trend in the size dependence but fails with respect to the strong modulations. The standard NLRGD model was found to fail altogether in the present particle size range, which was well beyond the observed upper particle size for which the NLRGD and NLWKB models give comparable results. A generalization of the NLRGD model to allow for dispersion and to use the particle refractive indices instead of those of the surrounding medium extended its applicability range by almost an order of magnitude in particle size. There is a pronounced maximal SHG efficiency for particles with a radius that is close to the fundamental wavelength inside the particle. The optically soft particle approximation is inadequate to describe the SHG in this particle size range, as refraction and reflection of the waves at the particle surface have a decisive influence. Dispersion of the media plays a negligible role for particle sizes up to about twice the optimal one for SHG.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical transport and statistics of radiative losses in disordered chains of microspheres

Optical transport in a one-dimensional chain of microspherical resonators with size disorder is studied in the spectral range of high-Q whispering gallery modes. An ab initio approach is used to develop a theoretical framework for analysis of steady-state transport parameters with main emphasis on properly defined radiative loss coefficient. Probability distribution and scaling properties of the latter are established and explained.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Casimir microsphere diclusters and three-body effects in fluids

Our previous paper [Phys. Rev. Lett. 104, 060401 (2010)] predicted that Casimir forces induced by the material-dispersion properties of certain dielectrics can give rise to stable configurations of objects. This phenomenon was illustrated via a dicluster configuration of nontouching objects consisting of two spheres immersed in a fluid and suspended against gravity above a plate. Here, we examine these predictions from the perspective of a practical experiment and consider the influence of nonadditive, three-body, and nonzero-temperature effects on the stability of the two spheres. We conclude that the presence of Brownian motion reduces the set of experimentally realizable silicon-teflon spherical diclusters to those consisting of layered microspheres, such as the hollow core (spherical shells) considered here.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-D-201-05: Phantom Study to Determine Optimal PET Reconstruction Parameters for PET/MR Imaging of Y-90 Microspheres Following Radioembolization

Purpose: Imaging Y-90 microspheres with PET/MRI following hepatic radioembolization has the potential for predicting treatment outcome and, in turn, improving patient care. The positron decay branching ratio, however, is very small (32 ppm), yielding images with poor statistics even when therapy doses are used. Our purpose is to find PET reconstruction parameters that maximize the PET recovery coefficients and minimize noise. Methods: An initial 7.5 GBq of Y-90 chloride solution was used to fill an ACR phantom for measurements with a PET/MRI scanner (Siemens Biograph mMR). Four hot cylinders and a warm background activity volume of the phantom were filled with a 10:1 ratio. Phantom attenuation maps were derived from scaled CT images of the phantom and included the MR phased array coil. The phantom was imaged at six time points between 7.5–1.0 GBq total activity over a period of eight days. PET images were reconstructed via OP-OSEM with 21 subsets and varying iteration number (1–5), post-reconstruction filter size (5–10 mm), and either absolute or relative scatter correction. Recovery coefficients, SNR, and noise were measured as well as total activity in the phantom. Results: For the 120 different reconstructions, recovery coefficients ranged from 0.1–0.6 and improved with increasing iteration number and reduced post-reconstruction filter size. SNR, however, improved substantially with lower iteration numbers and larger post-reconstruction filters. From the phantom data, we found that performing 2 iterations, 21 subsets, and applying a 5 mm Gaussian post-reconstruction filter provided optimal recovery coefficients at a moderate noise level for a wide range of activity levels. Conclusion: The choice of reconstruction parameters for Y-90 PET images greatly influences both the accuracy of measurements and image quality. We have found reconstruction parameters that provide optimal recovery coefficients with minimized noise. Future work will include the effects of the body matrix coil and off-center measurements.

60 APPLIED LIFE SCIENCES↗

SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with {sup 90}Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than other methods of dose calculation usually applied in the clinic.

60 APPLIED LIFE SCIENCES↗

IMPACT OF COMPOSITION AND HEAT TREATMENT ON PORE SIZE IN POROUS WALLED HOLLOW GLASS MICROSPHERES

The Savannah River National Laboratory (SRNL) developed a new geometric form: hollow glass microspheres (HGMs), with unique porous walls. The new geometric form combines the existing technology of HGMs with basic glass science knowledge in the realm of glass-in-glass phase separation. Conceptually, the development of a HGM with porous walls (referred to as a PWHGM) provides a unique system in which various media or filling agents can be incorporated into the PWHGM (via transport through the porous walls) and ultimately has the capacity to serve as a functional delivery system in various industrial applications. Applications of these types of systems could range from hydrogen storage, molecular sieves, drug and bioactive delivery systems, to environmental, chemical and biological indicators, relevant to Energy, Environmental Processing and Homeland Security fields. As a specific example, previous studies at SRNL have introduced materials capable of hydrogen storage (as well as other materials) into the interior of the PWHGMs. The goal of this project was to determine if the microstructure (i.e., pore size and pore size distribution) of a PWHGM could be altered or tailored by varying composition and/or heat treatment (time and/or temperature) conditions. The ability to tailor the microstructure through composition or heat treatments could provide the opportunity to design the PWHGM system to accommodate different additives or fill agents. To meet this objective, HGMs of various alkali borosilicate compositions were fabricated using a flame forming apparatus installed at the Aiken County Technical Laboratory (ACTL). HGMs were treated under various heat treatment conditions to induce and/or enhance glass in glass phase separation. Heat treatment temperatures ranged from 580 C to 620 C, while heat treatment times were either 8 or 24 hours. Of the two primary variables assessed in this study, heat treatment temperature was determined to be most effective in changing the porosity of PWHGMs. Pore diameter in a non-heat treated baseline sample is approximately 100 {angstrom} and with heat treatment at 600 C for 8 hours, the diameter is approximately 1000 {angstrom}; an increase of a factor of 10. The results of this study also indicate significant microstructural differences with only a 20 C difference in heat treatment temperature (580 C and 600 C) for constant times. The microstructural changes observed via electron microscopy as a function of heat treatment temperature were confirmed by mercury porosimetry measurements, where considerable increases in pore volume were measured. Under constant heat treatment conditions, composition may impose a secondary effect on the resulting microstructure as micrographs indicate variations in the degree of porosity. Although microstructural differences were observed among the compositions assessed, the magnitude of the impact (i.e., difference in pore size or pore volume) appears to be smaller than that associated with heat treatment temperature. With respect to heat treatment time, the results suggest that the change in the degree of porosity is minimal for samples heat treated between 8 and 24 hours (it should be noted that the assessment of the impact of time on the resulting microstructure was limited to two compositions). The minimal impact of heat treatment time (on the two glasses evaluated) was confirmed by mercury porosimetry measurements indicating that there was a very slight shift in pore diameter and very little increase in pore volume in the baseline sample. Another important parameter, which will need to be considered under manufacturing or operational conditions, is the yield of the HGM and/or PWHGM and the characteristics of the final product (i.e., not only microstructure characteristics, but perhaps strength of the PWHGM for use under certain applications). In this report, yield is defined as the percentage of feed material converted to HGMs or the percentage of HGMs converted to PWHGMs. The yield of HGM formation was found to be a strong function of composition. As the SiO{sub 2} and B{sub 2}O{sub 3} contents are increased or decreased from the baseline composition, the yield is reduced. PWHGM yield doesn't appear to be influenced by composition, but there is a noticeable increase in yield when comparing the non-heat treated samples to those that were heat treated prior to acid leaching. The results of this study suggest that PWHGM microstructures (pore size and pore volume) can be tailored or specifically designed to meet different end-user needs within certain limitations. The primary effect on the resulting microstructure is heat treatment temperature, which can produce a significant shift in pore size or volume even with a very small difference in heat treatment temperature (20 C). The ability to control the microstructure of PWHGMs provides the opportunity to design the PWHGM system to accommodate different additives or fill agents as required.

08 HYDROGEN↗

BIOCOMPATIBLE FLUORESCENT MICROSPHERES: SAFE PARTICLES FOR MATERIAL PENETRATION STUDIES (TAS Review Brief)

The use of biocompatible polymer microspheres has been proposed for use in drug delivery, dispersal model verification and as a surrogate for threat agents in instrument validation. Modifying the production methods used in drug delivery for aerosol production should allow for low cost bio-weapon simulants. The ability to have a polymer sphere with a broad range of property tuning will allow for safe low cost use for homeland security and defense applications. Three main challenges are present in the production of such spheres. The first challenge is the reproduction of the fluorescent and other chemical properties of interest. Secondly, the particles must have the size and charge attributes needed for the specific application and testing. Finally, in order to reproduce testing and evaluation criteria a rapid, reliable, scalable and low cost production method must be available.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SEM visualization of glycosylated surface molecules using lectin-coated microspheres

There are several techniques currently used to localize glycosylated surface molecules by scanning electron microscopy (Grinnell, 1980; Molday, 1976; Linthicum and Sell, 1975; Nicolson, 1974; Lo Buglio, et al, 1972). A simple and rapid method, using a modification of Grinnell's technique is reported here. Essentially, microspheres coated with Concavalin A are used to bind to glycosylated regions of the palatal shelf epithelium and are visualized in the scanning electron microscope (SEM).

Non-NASA Center↗

High-Q Microsphere Cavity for Laser Stabilization and Optoelectronic Microwave

With submillimeter size and optical Q up to ~ 10(sup 10), microspheres with whispering-gallery (WG) modes are attractive new component for fiber-optics/photonics applications and a potential core in ultra-compact high-spectral-purity optical and microwave oscillators.

microspheres fiber optics microwave photonics↗

A Fiber-Coupled Erbium-Doped Microsphere Laser

We report a demonstration of an erbium-doped silicate glass microsphere laser with both pumping (at~980nm) and the pickup of laser output (~1550nm) provided by novel angle-polished singel-mode fiber coupler.

microsphere↗

Irradiated Microsphere Gamma Analyzer for Examination of Particle Fuel

Fabrication of the first series of fuel compacts for the current US tristructural isotropic (TRISO) coated particle fuel development and qualification effort was completed at Oak Ridge National Laboratory (ORNL) in 2006. In November of 2009, after almost 3 years and 620 effective full power days of irradiation in the Advanced Test Reactor at Idaho National Laboratory (INL), the first Advanced Gas Reactor irradiation test (AGR-1) was concluded. Compacts were irradiated at a calculated timeaveraged, volume-averaged temperature of 955–1136°C to a burnup ranging from 11.2–19.5% fissions per initial metal atom and a total fast fluence of 2.2–4.3·1025 n/m2 [1]. No indication of fission product release from TRISO coating failure was observed during the irradiation test, based on real-time monitoring of gaseous fission products. Post-irradiation examination (PIE) and hightemperature safety testing of the compacts has been in progress at both ORNL and INL since 2010, and have revealed small releases of a limited subset of fission products (such as silver, cesium, and europium). Past experience has shown that some elements can be released from TRISO particles when a defect forms in the SiC layer, even when one or more pyrocarbon layers remain intact and retain the gaseous fission products. Some volatile elements can also be released by diffusion through an intact SiC layer during safety testing if temperatures are high enough and the duration is long enough. In order to understand and quantify the release of certain radioactive fission products, it is sometimes necessary to individually examine each of the more than 4000 coated particles in a given compact. The Advanced Irradiated Microsphere Gamma Analyzer (Advanced- IMGA) was designed to perform this task in a remote hot cell environment. This paper describes the Advanced- IMGA equipment and examination process and gives results for a typical full compact evaluation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗