Search NASA⌕ Search

SEARCH · Search NASA

Results for “Periodic Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Temporal Treatment of a Thermal Response for Defect Depth Estimation

Transient thermography, which employs pulse surface heating of an inspected component followed by acquisition of the thermal decay stage, is gaining wider acceptance as a result of its remoteness and rapidness. Flaws in the component s material may induce a thermal contrast in surface thermograms. An important issue in transient thermography is estimating the depth of a subsurface flaw from the thermal response. This improves the quantitative ability of the thermal evaluation: from one scan it is possible to locate regions of anomalies in thickness (caused by corrosion) and estimate the implications of the flaw on the integrity of the structure. Our research focuses on thick composite aircraft components. A long square heating pulse and several minutes observation period are required to receive an adequate thermal response from such a component. Application of various time-related informative parameters of the thermal response for depth estimation is discussed. A three-dimensional finite difference model of heat propagation in solids in Cartesian coordinates is used to simulate the thermographic process. Typical physical properties of polymer graphite composites are assumed for the model.

Plotnikov, Y. A.↗

Examining the Early Onset of Selected Large Solar Eruptions During the 2024 May Superstorm Episode

Recent studies indicate that solar flares are preceded by a period of above-ambient coronal heating, along with an increase in coronal X-ray emissions (Hudson et al. 2021). Despite being extremely common, the cause of these enhanced preflare emissions has not yet been understood. Here, our team examines in detail several of the large eruptions during the May 2024 superstorm period that resulted in significant geomagnetic disturbances. We use data from the Solar Dynamics Observatory's (SDO) Atmospheric Imaging Assembly (AIA) and Helioseismic and Magnetic Imager (HMI), from the Hinode satellite, and from other sources. For several of the GOES X-class events on 8-10 May, we find that the preflare heating signature is more complex than in the case of flares occurring in less dynamic solar regions, but nonetheless distinct hot (>~ 10 MK) preflare coronal signatures are present. Understanding of the cause of such preflare activity prior to the onset of geoeffective solar eruptions is essential to developing an eventual robust prediction algorithm for warning of impending solar eruptions that threaten Space Weather consequences.

Alphonse C. Sterling↗

Development Unit Configuration and Current Status of the MIP/MAAC Experiment

The Mars In-Situ Propellant Production (ISPP) Precursor (MIP) experiment package is planned for inclusion on the Mars 2001 Lander. This experiment package consists of five experiments whose purpose is to demonstrate the performance of various ISPP processes in-situ on Mars. The demonstrated ability to produce propellant for Mars Return Vehicles (MRV) is considered to be a necessary precursor to any future manned mission to Mars. The Mars Atmosphere Acquisition and Compression (MAAC) experiment is part of the MIP package and is intended to demonstrate that, by using a sorption compressor, CO2 can be preferentially adsorbed at about 6 torr from the Mars atmosphere during the night when the bed is cold then subsequently compressed to about 800 torr by heating the bed and desorbing CO2 during the day. The compressed CO2 produced by MAAC is to be fed to the Oxygen Generator Subsystem (OGS) where pure oxygen is to be produced. Pure oxygen is considered to be one of the primary constituents of a future manned MRV propellant system. A MAAC Development Unit (DU) has been fabricated and tested at JPL. The MAAC DU consists of 1) a sorption bed filled with a CO2 selective sorbent material, 2) a purge system to be used to periodically backflush non-CO2 gases from the sorbent bed during adsorption, 3) a JPL-developed gas-gap heat switch that allows heat transfer to a radiator for heat removal from the bed during the night time adsorption period and that impedes heat transfer during the day time desorption period, 4) a radiator to radiate heat to the night sky during the adsorption period, 5) a set of three isolation valves and connecting tubing. 6) two pressure transducers and several thermocouples for monitoring the MAAC operating conditions, and command and data handling electronics. This paper will describe the operational theory and the configuration of the MAAC DU and will discuss the current status of the MAAC experiment development including some selected results of performance testing that has been completed prior to the ISRU III meeting.

Karlmann, P. B.↗

Development Unit Configuration Status of the MIP/MAAC Experiment

The Mars In-Situ Propellant Production (ISPP) Precursor (MIP) experiment package is planned for inclusion on the Mars 2001 Lander. This experiment package consists of five experiments whose purpose is to demonstrate the performance of various ISPP processes in-situ on Mars. The demonstrated ability to produce propellant for Mars Return Vehicles (MRV) is considered to be a necessary precursor to any future manned mission to Mars. The Mars Atmosphere Acquisition and Compression (MAAC) experiment is part of the MIP package and is intended to demonstrate that, by using a sorption compressor, CO2 can be preferentially adsorbed at about 6 torr from the Mars atmosphere during the night when the bed is cold then subsequently compressed to about 800 torr by heating the bed and desorbing C02 during the day. The compressed CO2 produced by MAAC is to be fed to the Oxygen Generator Subsystem (OGS) where pure oxygen is to be produced. Pure oxygen is considered to be one of the primary constituents of a future manned MRV propellant system. A MAAC Development Unit (DU) has been fabricated and tested at JPL. The MAAC DU consists of: (1) a sorption bed filled with a CO2 selective sorbent material; (2) a purge system to be used to periodically backflush non-CO2 gases from the sorbent bed during adsorption; (3) a JPL-developed gas-gap heat switch that allows heat transfer to a radiator for heat removal from the bed during the night time adsorption period and that impedes heat transfer during the day time desorption period; (4) a radiator to radiate heat to the night sky during the adsorption period; (5) a set of three isolation valves and connecting tubing; (6) two pressure transducers and several thermocouples for monitoring the MAAC operating conditions, and command and data handling electronics. This paper will describe the operational theory and the configuration of the MAAC DU and will discuss the current status of the MAAC experiment development including some selected results of performance testing that has been completed prior to the ISRU III meeting.

Karlmann, P. B.↗

Theta-Pinch Thruster for Piloted Deep Space Exploration

A new high-power propulsion concept that combines a rapidly pulsed theta-pinch discharge with upstream particle reflection by a magnetic mirror was evaluated under a Phase 1 grant awarded through the NASA Institute for Advanced Concepts. Analytic and numerical models were developed to predict the performance of a theta-pinch thruster operated over a wide range of initial gas pressures and discharge periods. The models indicate that a 1 m radius, 10 m long thruster operated with hydrogen propellant could provide impulse-bits ranging from 1 N-s to 330 N-s with specific impulse values of 7,500 s to 2,500 s, respectively. A pulsed magnetic field strength of 2 T is required to compress and heat the preionized hydrogen over a 10(exp -3) second discharge period, with about 60% of the heated plasma exiting the chamber each period to produce thrust. The unoptimized thruster efficiency is low, peaking at approximately 16% for an initial hydrogen chamber pressure of 100 Torr. The specific impulse and impulse-bit at this operating condition are 3,500 s and 90 N-s, respectively, and the required discharge energy is approximately 9x10(exp 6) J. For a pulse repetition rate of 10 Hz, the engine would produce an average thrust of 900 N at 3,500 s specific impulse. Combined with the electrodeless nature of the device, these performance parameters indicate that theta-pinch thrusters could provide unique, long-life propulsion systems for piloted deep space mission applications.

LaPointe, Mike R.↗

Transient nucleate pool boiling in microgravity: Some initial results

Variable gravity provides an opportunity to test the understanding of phenomena which are considered to depend on buoyancy, such as nucleate pool boiling. The active fundamental research in nucleate boiling has sought to determine the mechanisms or physical processes responsible for its high effectiveness, manifested by the high heat flux levels possible with relatively low temperature differences. Earlier research on nucleate pool boiling at high gravity levels under steady conditions demonstrated quantitatively that the heat transfer is degraded as the buoyancy normal to the heater surfaced increases. Correspondingly, it was later shown, qualitatively for short periods of time only, that nucleate boiling heat transfer is enhanced as the buoyancy normal to the heater surface is reduced. It can be deduced that nucleate pool boiling can be sustained as a quasi-steady process provided that some means is available to remove the vapor generated from the immediate vicinity of the heater surface. One of the objectives of the research, the initial results of which are presented here, is to quantify the heat transfer associated with boiling in microgravity. Some quantitative results of nucleate pool boiling in high quality microgravity (a/g approximately 10(exp -5)) of 5s duration, obtained in an evacuated drop tower, are presented here. These experiments were conducted as precursors of longer term space experiments. A transient heating technique is used, in which the heater surface is a transparent gold film sputtered on a qua rtz substrate, simultaneously providing the mean surface temperature from resistance thermometry and viewing of the boiling process both from beneath and across the surface. The measurement of the transient mean heater surface temperature permits the computation, by numerical means, of the transient mean heat transfer coefficient. The preliminary data obtained demonstrates that a quasi-steady boiling process can occur in microgravity if the bulk liquid subcooling is sufficiently high and if the imposed heat flux is sufficiently low. This is attributed to suface tension effects at the liquid-vapor-solid junction causing rewetting to take place, sustaining the nucleate boiling. Otherwise, dryout at the heater surface will occur, as observed.

Merte, Herman, Jr.↗

Dynamics of Water Absorption and Evaporation During Methanol Droplet Combustion in Microgravity

The combustion of methanol droplets is profoundly influenced by the absorption and evaporation of water, generated in the gas phase as a part of the combustion products. Initially there is a water-absorption period of combustion during which the latent heat of condensation of water vapor, released into the droplet, enhances its burning rate, whereas later there is a water-evaporation period, during which the water vapor reduces the flame temperature suffciently to extinguish the flame. Recent methanol droplet-combustion experiments in ambient environments diluted with carbon dioxide, conducted in the Combustion Integrated Rack on the International Space Station (ISS), as a part of the FLEX project, provided a method to delineate the water-absorption period from the water-evaporation period using video images of flame intensity. These were obtained using an ultra-violet camera that captures the OH* radical emission at 310 nm wavelength and a color camera that captures visible flame emission. These results are compared with results of ground-based tests in the Zero Gravity Facility at the NASA Glenn Research Center which employed smaller droplets in argon-diluted environments. A simplified theoretical model developed earlier correlates the transition time at which water absorption ends and evaporation starts. The model results are shown to agree reasonably well with experiment.

Hicks, Michael C.↗

LOFTID Surface Heating Reconstruction

On November 10, 2022, the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) reentry vehicle launched to low-Earth orbit aboard a United Launch Alliance Atlas V rocket out of Vandenberg Air Force Base. The aeroshell, the largest Hypersonic Inflatable Aerodynamic Decelerator (HIAD) ever flown, was inflated to its full 6-meter diameter before successful re-entry into the atmosphere. The aeroshell was heavily instrumented in order to understand its behavior during entry. There were 82 thermocouples (TCs) distributed across the aeroshell, with 22 integrated into the flexible thermal protection system (FTPS) on the rigid nose, 36 in the FTPS on the deployable structure, and 24 on the inflatable structure. TCs were placed at different depths throughout the FTPS. Those nearest to the surface were located just beneath the two SiC outer fabric layers. The near-surface TCs on the rigid nose were Type R with flame spray alumina insulation, while those on the flank were Type N with mica/ceramic insulation. Additionally, a radiometer was placed at the center of the nose surrounded by four total heat flux gauges in a cruciform configuration at a radius of 0.41 m. The nose instrumentation is shown in Fig. 1 and a cross-section of the aeroshell with all TC locations is shown in Fig. 2. The objective of this work was to use the temperatures measured by the TCs during flight to estimate the surface heat rate across the aeroshell throughout the period of re-entry by inverse analysis methodology. The results were used to evaluate the fidelity of measurements from the total heat flux gauges on the nose, determine the surface heat flux at aeroshell locations where gauges were not present, and compare to pre-flight CFD-based heating predictions. Inversely estimated surface heat flux continues to be used to correlate FTPS thermal models to reconstruct in-flight thermal response.

H S Alpert↗

LOFTID Surface Heating Reconstruction

On November 10, 2022, the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) reentry vehicle launched to low-Earth orbit aboard a United Launch Alliance Atlas V rocket out of Vandenberg Air Force Base. The aeroshell, the largest Hypersonic Inflatable Aerodynamic Decelerator (HIAD) ever flown, was inflated to its full 6-meter diameter before successful re-entry into the atmosphere. The aeroshell was heavily instrumented in order to understand its behavior during entry. There were 82 thermocouples (TCs) distributed across the aeroshell, with 22 integrated into the flexible thermal protection system (FTPS) on the rigid nose, 36 in the FTPS on the deployable structure, and 24 on the inflatable structure. TCs were placed at different depths throughout the FTPS. Those nearest to the surface were located just beneath the two SiC outer fabric layers. The near-surface TCs on the rigid nose were Type R with flame spray alumina insulation, while those on the flank were Type N with mica/ceramic insulation. Additionally, a radiometer was placed at the center of the nose surrounded by four total heat flux gauges in a cruciform configuration at a radius of 0.41 m. The nose instrumentation is shown in Fig. 1 and a cross-section of the aeroshell with all TC locations is shown in Fig. 2. The objective of this work was to use the temperatures measured by the TCs during flight to estimate the surface heat rate across the aeroshell throughout the period of re-entry by inverse analysis methodology. The results were used to evaluate the fidelity of measurements from the total heat flux gauges on the nose, determine the surface heat flux at aeroshell locations where gauges were not present, and compare to pre-flight CFD-based heating predictions. Inversely estimated surface heat flux continues to be used to correlate FTPS thermal models to reconstruct in-flight thermal response.

LOFTID↗

Characteristics of precipitation regimes during the global weather experiment

Rainfall data were used in conjunction with heating rate values obtained from GLA/NASA to describe large scale heating changes and concurrent circulation fluctuations for weekly averages during the Special Observing Period I (January-March 1979) of the Global Weather Experiment. The GLA diabatic heating rates were obtained as residues of the thermodynamic energy equation during the four-dimensional data assimilation cycle (as described by Kalnay and Baker, 1984). In week one, the heating and rainfall rate profiles display a positive anomaly on the West Pacific in both fields. The anomaly appears to propagate eastward into the East Pacific and South America by the fifth week. By the week four, the negative anomaly over the Indian Ocean becomes positive. These heating patterns are reflected on positive divergent anomalies at 200 mb analyzed for the same periods. The stream-function anomalies display anticyclonic circulations over the heating anomalies.

Ahrens, Glen D.↗

Single-family-residence solar heating--Carlsbad, New Mexico

Solar-heating and hot-water system includes 408 square feet of flat-plate air collectors, rock storage bin, energy transport system, air-to-water heat exchanger, controls, and hot-water preheat tank. Hot-air oil furnace supplies auxiliary space heating, and electricity powers air-handler blower and hot water preheat pump. For 12 month period, system provided 43 percent of space-heating and 53 percent of hot-water energy; net energy savings were 23.072 million Btu.

Source record↗

Latent heat and cyclone activity in the South Pacific, 10-18 January 1979

This paper examines the heat budget of the tropical South Pacific for the period of January 10-18, 1979 and compares precipitation estimates obtained from the budget equation with those derived from GOES-IR satellite imagery, using data that were part of the total FGGE package. In addition, the relationship between latent heat release and the baroclinic energy conversion is examined for the life cycles of two cyclones which propagated along the South Pacific Convection Zone in that period. It is shown that latent heat plays an important role in the baroclinic energy conversion between potential and kinetic energy through diabatically-induced vertical circulations. For a cyclone where latent heat stays at a high level both spacially and with regard to intensity, there appears to be ample fuel for its intensification. On the other hand, for a filling cyclone, the latent heat impact decreased and the baroclinic conversion fell off rapidly, due to the lack of both potential energy generation and diabatically-induced thermally-direct circulations.

Miller, B. L.↗

Analysis of Free-Flight Laminar, Transitional, and Turbulent Heat-Transfer Results at Free-Stream Mach Numbers Near 20 (Reentry F)

Laminar, transitional, and turbulent heat-transfer data were measured during a reentry flight at a Mach number of 20 on a 5 deg half-angle cone 3.962 m (13 ft) long with an initial nose tip radius of 0.254 cm (0.1 in.). The free-stream Reynolds number increased during the prime data period from 7.0 x 10(exp 6) to 51.5 x 10(exp 6) per meter (2.1 x 10(exp 6) to 15.7 x 10(exp 6) per foot) and the ratio of wall to total temperature varied from 0.053 to 0.12. The angle of attack was less than 1deg for the prime data period. The experimental laminar and turbulent heating rates are compared with results from existing flat-plate prediction methods. At conditions of minimal tip blunting and angle of attack (above 26.8 km (88 000 ft)), values from a flat-plate laminar method agreed within 20 percent with the laminar data. The Schultz-Grunow skin-friction equation with reference enthalpy; conditions, with the Reynolds number based on distance from the transition location, and with the Colburn Reynolds analogy agreed within 10 percent with the experimental turbuleiit heating data. The Van Driest n skin-friction equation with Reynolds number greater than 10(exp 7) based on distance from the peak heating point and the Colburn Reynolds analogy was also within approximately 10 percent of the experimental turbulent heating data. A data correlation jbf the extent of transition and a simple empirical transition-zone heating correlation were also presented.

Zoby, Ernest V.↗

Organic Biomarker-Based Assays to Evaluate Total Bioburden and Organic Compounds on Space Flight Hardware

Meeting planetary protection (PP) requirements for space flight hardware may involve bioburden reduction by dry heat microbial reduction (DHMR). The NASA standard assay to demonstrate the reduction of organisms involves the swabbing of surfaces, heat shock of the extracted samples, plating of the samples on Trypticase Soy Agar (TSA), and counting colony forming units after an incubation period. The standard assay uses enumeration of heat tolerant spore-formers as a proxy for total bioburden and is generally expected to provide a lower limit. We suggest that a better estimate of the total bioburden could be obtained through sampling and analysis of organic biomarkers. As biological organisms are fundamentally organic in chemistry (i.e. carbon containing materials) it is important to characterize the biomarker compounds that are released from organisms that 1) exist on flight hardware before microbial reduction and 2) left behind from the killed organisms following microbial reduction.

Locke, Darren R.↗

Northern North Atlantic Sea Surface Height and Ocean Heat Content Variability

The evolution of nearly 20 years of altimetric sea surface height (SSH) is investigated to understand its association with decadal to multidecadal variability of the North Atlantic heat content. Altimetric SSH is dominated by an increase of about 14 cm in the Labrador and Irminger seas from 1993 to 2011, while the opposite has occurred over the Gulf Stream region over the same time period. During the altimeter period the observed 0-700 m ocean heat content (OHC) in the subpolar gyre mirrors the increased SSH by its dominantly positive trend. Over a longer period, 1955-2011, fluctuations in the subpolar OHC reflect Atlantic multidecadal variability (AMV) and can be attributed to advection driven by the wind stress ''gyre mode'' bringing more subtropical waters into the subpolar gyre. The extended subpolar warming evident in SSH and OHC during the altimeter period represents transition of the AMV from cold to warm phase. In addition to the dominant trend, the first empirical orthogonal function SSH time series shows an abrupt change 2009-2010 reaching a new minimum in 2010. The change coincides with the change in the meridional overturning circulation at 26.5N as observed by the RAPID (Rapid Climate Change) project, and with extreme behavior of the wind stress gyre mode and of atmospheric blocking. While the general relationship between northern warming and Atlantic meridional overturning circulation (AMOC) volume transport remains undetermined, the meridional heat and salt transport carried by AMOC's arteries are rich with decade-to-century timescale variability.

Sea-surface↗

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE↗

Measurement of the heat produced internally during discharge by the 6V Eveready Energizer Battery, no. 528

When a 6V Eveready Energizer Battery, 528, is discharged, heat is produced internally within the battery itself. Detailed measurements of this battery heat were made for a five day discharge period using a load resistance of 20 ohms and an ambient temperature of 10 C. The battery heat produced per quarter day varied considerably, ranging from 1.08 watt-hrs to 2.63 watt-hrs. The total battery heat produced, using a 3.0 volt cutoff, is significant (37 watt-hrs) when compared to the total load heat produced (70 watt-hrs).

F. D. Hooker↗

Thermal coupling-decoupling mechanism of heat transfer across van der Waals interfaces in n-eicosane

Progress toward improving thermal transport properties of n-eicosane, a promising phase change material for thermal energy storage near human body temperature, is hindered by lack of a general theoretical framework to model thermal interfacial conductance (TIC) of the van der Waals (vdW) force bonded molecular interfaces, which have little compositional/structural mismatch. Combining molecular dynamics simulations at temperatures up to the melting point and a time-domain analysis of interfacial heat currents in individual molecules, we unveil that (1) the heat flux across a molecular vdW interface has an alternating coupling-decoupling pattern at the single molecule level due to thermal fluctuations, and (2) the net heat transfer during the thermally coupled periods is orders of magnitude larger than that during the thermally decoupled periods. Furthermore, we demonstrate that a vdW interface's TIC correlates almost linearly with two atomistic-scale coupling-decoupling parameters: αc and σc, that represent the duration and strength of the thermal coupling, respectively. This thermal coupling-decoupling mechanism proposes a new paradigm that explicitly accounts for the effects of structural flexibility and dynamical fluctuation on heat transfer across molecular interfaces, and will likely provide new insights into modeling thermal transport properties in a wide-ranging soft materials, including self-assembled monolayers, paraffins or lipids.

42 ENGINEERING↗