Search NASA⌕ Search

SEARCH · Search NASA

Results for “RECORDING INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

AGC-4 Experiment Irradiation Monitoring Data Qualification Final Report

The Graphite Technology Development Program ran a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. This report focuses on the fourth experiment, Advanced Graphite Creep 4 (AGC 4). The Advanced Reactor Development (ARD) Technology Development Office (TDO) Program for research and development activities require documentation of qualified monitoring data to design and license the first high-temperature reactor nuclear plant. Qualified data meets the requirements for use as described in the experiment planning and quality assurance documents. Failed data do not meet the requirements and provide no useable information. Trend data may not meet all requirements but still provide some useable information. Use of Trend data requires assessment of how any deficiencies affect a particular use of the data. AGC-4 began with Advanced Test Reactor (ATR) Cycle 157D on May 30, 2015. After irradiating the graphite for two cycles, the capsule was removed from the reactor after ATR Cycle 158A, which ended on January 2, 2016, due to interference with another experiment. Irradiation was resumed with Cycle 162A on October 7, 2017 after the interfering experiment was removed from the reactor. AGC-4 irradiation completed by the end of Cycle 166B on January 10, 2020. Between Cycles 162A and 166B, AGC-4 capsule was removed from the reactor core during two Powered Axial Locator Mechanism (PALM) Cycles 163A and 165A to avoid overheating. All thermocouples (TCs) have functioned throughout the AGC-4 experiment. A total of 9,256,184 out of all 11,167,213 temperature records (or 82.9%) are Qualified for use by the ARD Program and 1,911,029 missing values are Failed. Argon, helium, and total gas flow data were within expected ranges, except only eight out-of-range values occurred during outages. A total of 21,240,627 out of all 22,288,5103 gas flow rates (or 92.8%) are Qualified for use by the ARD Program and 1,644,476 are Failed records mostly due to missing values. Discharge gas line moisture values were consistently low during full ATR power, except for 162B, when moisture content was increasing to more than 200 ppmv by the end of this cycle. During outages, moisture content reached as high as 700 ppmv. 1,089,941 out of a total of 1,107,331 moisture values (or 98.4%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 17,390 missing moisture values are Failed. Graphite creep specimens were subjected to one of three loads: 393, 491, or 589 lbf. For a brief period during Cycle 157D between 12:19 on June 2, 2015, and 08:23 on June 11, 2015, the load cells were wired incorrectly, resulting in missing stack load data. Missing stack loads were estimated from measured ram pressures using regression equations developed from the existing data from Cycle 157D. Estimated stack loads during this period are considered to be an accurate representation of actual load applied to the stacks. These loads deviate slightly from the planned loads. This deviation does not prevent the data from being Qualified for use but must be taken into account when analyzing the effect of load on creep. 6,095,728 out of a total of 6,403,985 moisture values (or 95.2%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 308,257 missing load values are Failed. Stack displacement increased consistently throughout the eight cycles, with total displacement reached highest value of 2.4 in by the end of irradiation. During ATR outages, a set of pneumatic rams raised the stacks of graphite creep specimens to ensure the specimens were not stuck within the test train. This stack raising was performed seven times throughout irradiation. All stacks were raised successfully each time. 4,744,974 out of a total of 6,094,513 displacement values (or 77.9%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 1,349,539 displacement values are Failed mostly due to missing values. Analyses were conducted on correlations between TCs to look for trends and step changes that might indicate instrument degradation or failure. Correlation analysis was used to identify instances when TCs form short circuits, referred to as virtual junctions, which result in TCs reporting temperatures from some location in the capsule other than the location where they were intended to read. No evidence of virtual junctions was found. Analyses were also conducted on control charts of temperature differences of between two TCs, which are expected to behave consistently throughout the entire irradiation period. Upward or downward trend over time indicates at least one TC in the pair was drifted. Examining control charts for all 66 possible pairs out of twelve TCs installed in the AGC-4 capsules reveal no clear drift failures occurred, except unstable behavior of two TCs in Zone 3, TC-7 and TC-8, over irradiation time. In conclus

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accurate prediction of mega-electron-volt electron beam properties from UED using machine learning

To harness the full potential of the ultrafast electron diffraction (UED) and microscopy (UEM), we must know accurately the electron beam properties, such as emittance, energy spread, spatial-pointing jitter, and shot-to-shot energy fluctuation. Owing to the inherent fluctuations in UED/UEM instruments, obtaining such detailed knowledge requires real-time characterization of the beam properties for each electron bunch. While diagnostics of these properties exist, they are often invasive, and many of them cannot operate at a high repetition rate. Here, we present a technique to overcome such limitations. Employing a machine learning (ML) strategy, we can accurately predict electron beam properties for every shot using only parameters that are easily recorded at high repetition rate by the detector while the experiments are ongoing, by training a model on a small set of fully diagnosed bunches. Applying ML as real-time noninvasive diagnostics could enable some new capabilities, e.g., online optimization of the long-term stability and fine single-shot quality of the electron beam, filtering the events and making online corrections of the data for time-resolved UED, otherwise impossible. This opens the possibility of fully realizing the potential of high repetition rate UED and UEM for life science and condensed matter physics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Acoustic Signatures of Solvent Extraction Processes [Poster and Paper]

Data from four low-frequency acoustic sensors were used to investigate potential acoustic characteristics of centrifugal contactor, aqueous pump, and organic pump activity during the experiment. Three of the four sensors were Gem Infrasound Loggers (Anderson, et al. 2018) with serial numbers 190, 189, and 188. They will hereafter be referred to as GEM190, GEM189, and GEM188, respectively. The fourth acoustic sensor was a Raspberry Shake & Boom (Raspberry Shake 2017), which will hereafter be referred to as the RS&B. All four sensors record audio at a sampling rate of 100 Hz, allowing analysis of signals with characteristic frequencies up to 50 Hz.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating the state-of-the-art in remote volcanic eruption characterization Part II: Ulawun volcano, Papua New Guinea

Retrospective eruption characterization is valuable for advancing our understanding of volcanic systems and evaluating our observational capabilities, especially with remote technologies (defined here as a space-borne system or non-local, ground-based instrumentation which include regional and remote infrasound sensors). In June 2019, the open-system Ulawun volcano, Papua New Guinea, produced a VEI 4 eruption. We combined data from satellites (including Sentinel-2, TROPOMI, MODIS, Himawari-8), the International Monitoring System infrasound network, and GLD360 globally detected lightning with information from the local authorities and social media to characterize the pre-, syn- and post-eruptive behaviour. The Rabaul Volcano Observatory recorded ~24 h of seismicity and detected SO 2 emissions ~16 h before the visually-documented start of the Plinian phase on 26 June at 04:20 UTC. Infrasound and SO2 detections suggest the eruption started during the night on 24 June 2019 at 10:39 UTC ~38 h before ash detections with a gas-dominated jetting phase. Local reports and infrasound detections show that the second phase of the eruption started on 25 June 19:28 UTC with ~6 h of jetting. The first detected lightning occurred on 26 June 00:14 UTC, and ash emissions were first detected by Himawari-8 at 01:00 UTC. Post-eruptive satellite imagery indicates new flow deposits to the south and north of the edifice and ash fall to the west and southwest. In particular, regional infrasound data provided novel insight into eruption onset and syn-eruptive changes in intensity. We conclude that, while remote observations are sufficient for detection and tracking of syn-eruptive changes, key challenges in data latency, acquisition, and synthesis must be addressed to improve future near-real-time characterization of eruptions at minimally-monitored or unmonitored volcanoes.

58 GEOSCIENCES↗

Idaho National Laboratory Data Acquisition And Processing System

The INLDAS data acquisition and processing system is designed to develop prototype measurements and real-time processing techniques. The INLDAS hardware and firmware currently consists of National Instruments • NI-DAQmx 14.1 • cDAQ-9184 • 9205 • 9211 INLDAS can perform of standard data acquisition functions as well as novel functions and real-time processing algorithms. There are 3 acquisition modes to choose from: • Continuous mode runs when the user hits start, processing data and logging it to file • SWTrigger mode waits for one or more predefined triggers before acquiring data. It will buffer data as well, so it can record data that happened shortly before the trigger • Wakeup mode waits on predefined timers. When a time goes off, it acquires a preset amount of data There are also 3 Data Processing Modes • Normal mode does no processing besides the rolling average • FFT Mode Performs an FFT on incoming data every time the time window has elapsed • STFFT mode

Smith, JamesA↗

High efficiency Al/Sc-based multilayer coatings in the EUV wavelength range above 40 nanometers

In this Letter, we have developed new and highly efficient periodic multilayer mirrors Al/Sc, Al/Sc/SiC, and Mo/Al/Sc with optimized reflectance at wavelengths between 40 and 65 nm. We have reached record values in measured peak reflectance: 57.5% at 44.7 nm and 46.5% at 51 nm, with Al/Sc/SiC at near-normal incidence. Furthermore, to the best of our knowledge, we have achieved the largest reported bandwidth with Mo/Al/Sc at 57 nm and the narrowest bandwidth with Al/Sc at a 60 nm wavelength. These new and promising results demonstrate that Al/Sc-based multilayer coatings are excellent candidates for future generations of extreme ultraviolet (EUV) instruments for solar physics, EUV lasers, and attosecond science, in a wavelength range that has not been fully explored.

36 MATERIALS SCIENCE↗

2020 ETI Annual Summer School: Data Science and Engineering

The Consortium for Enabling Technologies & Innovation (ETI) was established in 2019 to address emerging technologies within the context of nuclear nonproliferation. ETI creates a research and education environment to support cross-cutting technologies across three core disciplines: 1) computer and engineering science research specifically in a form of machine learning and high performance computing (HPC), 2) advanced manufacturing, and 3) nuclear detection technologies. For outreach and development, ETI hosted the first of three summer schools from August 24-28, 2020 with the theme of “Data Science and Engineering”. The school was hosted in an on-line format and had over 200 participants. The recorded content is available on-line as a resource for students. The summer school had four modules: 1) Fundamentals of data Applications, 2) Computational Machine Learning, 3) Bayesian Modeling and Inference, and 4) Data Science for Safeguards. Modules contained both lectures as well as student exercises. Poll Everywhere was utilized in some modules as an on-line method to engage large groups of students. Upcoming ETI Summer Schools include Novel Instrumentation in 2021 and Advanced Manufacturing in 2022.

Biegalski, Steven R.↗

TITUS: Visualization of Neutrino Events in Liquid Argon Time Projection Chambers

The amount and complexity of data recorded by high energy physics experiments are rapidly growing, and with these grow the difficulties in visualizing such data. To study the physics of neutrinos, a type of elementary particle, scientists use liquid argon time projection chamber (LArTPC) detectors, among other technologies. LArTPCs have a very high spatial resolution and resolve many of the elementary particles that come out of a neutrino interacting within the argon in the detector. Visualizing these neutrino interactions is of fundamental importance to understanding the properties of neutrinos, but also monitoring and checking on the detector conditions and operations. From these ideas, we have developed TITUS, an event display that shows images recorded by these neutrino detectors. TITUS is a piece of software that reads data coming from LArTPC detectors (as well as the corresponding simulation) and allows users to explore such data in multiple ways. TITUS is flexible to enable fast prototyping and customization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The 100-month Swift catalogue of supergiant fast X–ray transients

Supergiant fast X-ray transients (SFXTs) are high mass X-ray binaries (HMXBs) displaying X-ray outbursts that can reach peak luminosities up to 10 38 erg s -1 and spend most of their lives in more quiescent states with luminosities as low as 10 32 -10 33 erg s -1 . During the quiescent states, less luminous flares are also frequently observed with luminosities of 10 34 -10 35 erg s -1 . The main goal of the comprehensive and uniform analysis of the SFXT Swift triggers presented in this paper is to provide tools to predict whether a transient that has no known X-ray counterpart may be an SFXT candidate. These tools can be exploited for the development of future missions exploring the variable X-ray sky through large field-of-view instruments. We examined all available data on outbursts of SFXTs that triggered the Swift/Burst Alert Telescope (BAT) collected between 2005 August 30 and 2014 December 31, in particular those for which broad-band data, including the Swift/X-ray Telescope (XRT) data, are also available. This work complements and extends our previous catalogue of SFXT flares detected by BAT from 2005 February 12 to 2013 May 31, since we now include the additional BAT triggers recorded until the end of 2014 (i.e. beyond the formal first 100 months of the Swift mission). Due to a change in the mission’s observational strategy, virtually no SFXT triggers obtained a broad-band response after 2014. We processed all BAT and XRT data uniformly by using the Swift Burst Analyser to produce spectral evolution dependent flux light curves for each outburst in the sample. The BAT data allowed us to infer useful diagnostics to set SFXT triggers apart from the general γ-ray burst population, showing that SFXTs uniquely give rise to image triggers and are simultaneously very long, faint, and ‘soft’ hard-X-ray transients. We find that the BAT data alone can discriminate very well the SFXTs from other classes of fast transients, such as anomalous X-ray pulsars and soft gamma repeaters. On the contrary, the XRT data collected around the time of the BAT triggers are shown to be decisive for distinguishing SFXTs from, for instance, accreting millisecond X-ray pulsars and jetted tidal disruption events. The XRT observations of 35 (out of 52 in total) SFXT BAT triggers show that in the soft X-ray energy band, SFXTs display a decay in flux from the peak of the outburst of at least three orders of magnitude within a day and rarely undergo large re-brightening episodes, favouring in most cases a rapid decay down to the quiescent level within three to five days (at most).

79 ASTRONOMY AND ASTROPHYSICS↗

Data associated with the manuscript “Radiative impact of record-breaking wildfires from integrated ground-based data” collected in Richland, Washington in September 2020

This data package is associated with the publication “Radiative impact of record-breaking wildfires from integrated ground-based data” submitted to Nature Scientific Reports (Kassianov et al., 2024). Data from ground-based measurements of shortwave and spectrally resolved irradiance and aerosol optical depth (AOD) in the visible and near-infrared spectral ranges were assessed to quantify the radiative impact of the September 2020 wildfires that occurred in the Western United States. Data were collected in September 2020 by several ground-based instruments at the Atmospheric Measurements Laboratory (AML) located in Richland, Washington (46.3451, -119.2792). These data include (1) Aerosol Optical Depth (AOD); (2) spectrally resolved and shortwave (SW) irradiances; (3) backscatter profiles; (4) total sky images; and (5) near-surface ambient air temperatures.The data package consists of five sub-directories: (1) “AML_Ceilometer_”; (2)” AML_CSPHOT_”; (3) “AML_MFRSR_irradiances_”; (4) “AML_SW_irradiances_and_Temp_”; (5) “AML_TSI_images_”; and 6 files stored at the directory level, including the readme, file-level metadata file, and data dictionary. The file-level metadata file (the file ending in “_flmd.csv”) lists all files contained in this data package and descriptions for each. The data dictionary (the file ending in “_dd.csv”) describes each tabular column header’s unit, definition, and structure. Below are descriptions of each sub-directory:“AML_Ceilometer_” includes ceilometer data collected at the AML. These files contain the corresponding narratives of data. Details related to the ceilometer data can be found in Morris (2016). “AML_CSPHOT_” includes ascii files with high-temporal resolution (about 10-15 min) AML CSPHOT data and their daily-averaged counterparts. These two files contain the corresponding narratives of data. Details related to the CSPHOT data can be found in Gregory (2011). “AML_MFRSR_irradiances_” includes ascii files with the AML MFRSR-measured diffuse, normal, and total spectrally resolved irradiance. Details related to the MFRSR data can be found in Hodges and Michalsky (2016) and Koontz et al. (2013). “AML_SW_irradiances_+_Temp_” includes near-surface ambient air temperature and SW irradiances, namely direct normal, diffuse hemispherical, and total hemispheric (global), measured at the AML. These files also incorporate the corresponding narratives of data. Details related to the SW irradiances can be found in Andreas et al. (2018). “AML_TSI_images_” includes Total Sky Images (TSIs) collected at the AML. Details related to the TSI data can be found in Morris (2005).

54 ENVIRONMENTAL SCIENCES↗

Holes in Optical Lightning Flashes: Identifying Poorly Transmissive Clouds in Lightning Imager Data

Space-based optical lightning sensors including the lightning imaging sensor (LIS) and geostationary lightning mapper (GLM) are pixelated imagers that detect lightning as transient increases in cloud top illumination. Detection requires optical emissions to escape the cloud top to space with sufficient energy to trigger a pixel on the imaging array. Through scattering and absorption, certain clouds are able to block most light from reaching the instrument, causing a reduction in detection efficiency (DE) and possibly location accuracy (LA). Radiant lightning emissions that illuminate large cloud top areas are used to examine scenarios where clouds block light from reaching orbit. In some cases, these anomalies in the spatial radiance distribution from the lightning pulse lead to “holes” in the optical lightning flash where certain pixels fail to trigger. Such holes are identified algorithmically in the Tropical Rainfall Measuring Mission satellite LIS record and the microphysical properties of the coincident storm region are queried. We find that holes primarily occur in tall (IR T b < 235 K) convection (87%) and overhanging anvil clouds (10%). The remaining 3% of holes occur in moderate-to-weak convection or in clear air breaks between stormclouds. We further demonstrate how an algorithm that assesses the spatial radiance patterns from energetic lightning pulses might be used to construct an optical transmission gridded stoplight product for GLM that could help operators identify clouds with a potentially reduced DE and LA.

54 ENVIRONMENTAL SCIENCES↗

Three-colour digital holographic microscopy based on a Mach – Zender interferometer and a solid-state RGB laser

We have developed a facility for recording colour digital holograms involving a Mach – Zender interferometer and a pulsed solid-state RGB laser, which radiates simultaneously at three wavelengths: 451, 532, and 634 nm. These wavelengths are obtained in the conversion of the radiation of a pulsed Nd{sup 3+} : YAG laser (1064 nm), which operates in the regime of intracavity parametric oscillation at a wavelength of 1570 nm, with the subsequent conversion of its frequencies to the red, green, and blue spectral regions in nonlinear KTP-crystal elements. The combination of this three-wavelength pulsed light source with the Mach – Zender interferometer provides the simultaneous recording of three spectral digital holograms with one matrix RGB radiation detector. Pulsed three-colour digital holography shows promise for the analysis of fast processes and rapidly varying colour phase objects. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MHD-240 Neutron Detection Efficiency and Sensitivity Calibration

The neutron detection efficiency of the MHD-240 scintillation detector was measured at Ohio University Edwards Accelerator Laboratory. Pulsed broad-spectrum sources from the 27 Al(d,n) and 9 Be(d,n) reactions were used to produce the neutrons. The neutron time-of-flight technique was used to make an energy-differential efficiency measurement. The measurements were made in a low rate pulse mode. The pulse height distribution was also recorded, and the data were used to derive a neutron sensitivity that would be applicable in a high rate environment such as a critical assembly where the detector would be expected to operate in a current mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Texas A&M University Mobile Facility Measurements during TRACER (Field Campaign Report)

One of the main goals of the U.S Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Tracking Aerosol Convection Interactions Experiment (TRACER) near Houston, Texas is to improve understanding of how meteorology and aerosols impact storm dynamical and microphysical processes in deep convection to better constrain and improve their model representation. The Houston area is strongly influenced by sea- and bay-breeze circulations that generate convergence and help to initiate and organize deep convection. To properly isolate and understand the roles of varied meteorological conditions and cloud condensation nuclei (CCN) and ice nucleation particles (INP) distributions in different air masses, co-located thermodynamic, kinematic, and aerosol vertical profile observations are needed. The focus of this campaign was to provide key measurements in air masses both in front of and behind sea/bay breeze fronts moving through the greater Houston area to sample the airmass heterogeneity. The overarching scientific goal of this campaign is to understand how the vertical distributions of both CCN and INP correspond to the inflow layer of deep convection in maritime, background continental, and polluted continental air masses, and how these variations influence deep convection. To fully sample the heterogeneity in both meteorological conditions and aerosols across the sea-breeze front (SBF), Texas A&M University (TAMU) deployed a InterMet 3050A 403 MHz mobile unit launching iMet-4 radiosondes and the new Rapid Onsite Atmospheric Measurement Van (ROAM-V) for aerosol sampling during the TRACER intensive operational period (IOP) from June to September 2022. The suite of instruments deployed on ROAM-V included a condensation particle counter (CPC; GRIMM Model 5.403 CPC), scanning mobility particle sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A differential mobility analyzer), cloud condensation nuclei counter (Droplet Measurement Technologies CCN counter), micropulse lidar (Droplet Measurement Technologies micropulse lidar [miniMPL]), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the Global Positioning System (GPS) on the phone application “My Altitude”. The DRUM data were collected as part of a closely related ARM field campaign and also supported by DOE Atmospheric System Research grant DE-SC0021047. The TAMU team sampled these airmass heterogeneities by strategically choosing deployment sites in a different airmass than the ARM fixed sites in La Porte and Guy, Texas. On days when the sea/bay breeze boundary was pushing inland, the TAMU team would usually sample the airmass on the maritime side of the SBF at a coastal site in Galveston, Texas in the early afternoon (1730-1900 UTC) and then move inland ahead of the SBF to sample the airmass on the continental side during late afternoon (2030-2230). Figure 1 shows the Galveston maritime site and the array of sites for the late afternoon continental measurements.

54 ENVIRONMENTAL SCIENCES↗

Test GammaPix™ Radiation Detection Software with Smartphones

GammaPix™ is a smartphone application that uses smartphone cameras to detect ionizing radiation. Brookhaven National Laboratory (BNL) evaluated the performance of the software in detecting radioactive materials. For this purpose, a series of tests were conducted at the Radiation Calibration Facility Annex at BNL. The experiments included dose measurements with three types of NIST-traceable calibration sources, 60Co, 241Am, and 137Cs. The recorded results by GammaPix™ were compared with the values measured by calibrated dosimeters to determine the detection thresholds. Several selected models of iPhones and Android cell phones with different pixel sizes and resolution were tested. In this paper, we present the test procedures and discuss the test results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical device for in-line and real-time monitoring of microorganisms

A multi-wavelength laser diode based optical sensor system capable of monitoring the dynamics and physiological changes of a microorganism culture in real-time. The microorganism culture from a microorganism production chamber is pumped to a flow chamber. Laser diodes emit light at certain wavelengths through the flow chamber, which is sensed by photodiodes. A laser control circuitry is operatively connected to the laser diodes and a signal conditioning circuitry is operatively connected to the photodiodes. A microprocessor reads and records voltage signals corresponding to the wavelengths. A data acquisition system converts said voltage signals into measurements of biological parameters, which are displayed on a graphical user interface and allow a user to monitor the measurements in real time.

47 OTHER INSTRUMENTATION↗

Relation between sampling, sensitivity and precision in strain mapping using the Geometric Phase Analysis method in Scanning Transmission Electron Microscopy

The sensitivity and the precision of the Geometric Phase Analysis (GPA) method for strain characterization is a topic widely discussed in the literature and is usually difficult to quantify. Indeed, the GPA precision is intricately linked to the resolution of the strain maps defined when masking the periodic reflections in Fourier space. In this study an additional parameter, sampling, is proposed to be analyzed regarding the precision of GPA by developing the concept of a phase noise in the GPA equations. Both experimentally and theoretically, the following article demonstrates how the precision, and the sensitivity of the GPA method is improved when using a larger pixel spacing to record an electron micrograph in Scanning Transmission Electron Microscopy (STEM). In conclusion, the counterintuitive concept of increasing the field of view to improve the GPA precision results in an extension of the application of strain characterization methods in STEM towards low deformation levels.

47 OTHER INSTRUMENTATION↗