Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Machine Tool Data Analytics for Digital Twin and Machine Predictive Maintenance

The primary objective of this project is to improve machining process performance using in-process machining data from the machine tool controller and external sensors. Advances in the Industrial Internet of Things (IIoT) enable monitoring of machines using controller data. Examples of the data provided by a controller include execution status of the controller, part count, block of code being executed, door status, tool position, the spindle and axis load, etc. MTConnect and OPC-UA are the two common protocols for capturing machine information. In this collaboration, methods for retrieving the machine controller data from selected machine tool controls and making these data accessible in different subsystems (such as digital twins and machine maintenance portals, etc.) will be developed and tested. In addition, analytics to improve machining process performance (by increasing productivity and reducing downtime) will be developed.

42 ENGINEERING↗

Improving Control System Cyber-State Awareness using Known Secure Sensor Measurements

Abstract—This paper presents design and simulation of a low cost and low false alarm rate method for improved cyber-state awareness of critical control systems - the Known Secure Sensor Measurements (KSSM) method. The KSSM concept relies on physical measurements to detect malicious falsification of the control systems state. The KSSM method can be incrementally integrated with already installed control systems for enhanced resilience. This paper reviews the previously developed theoretical KSSM concept and then describes a simulation of the KSSM system. A simulated control system network is integrated with the KSSM components. The effectiveness of detection of various intrusion scenarios is demonstrated on several control system network topologies.

97 MATHEMATICS AND COMPUTING↗

A Novel Solid Electrolyte Oxygen Sensor System for In-Situ Measurement and Process Control

In 1993 the oxygen partial pressure was firstly measured inside a plasma wind tunnel using conventional {lambda}-probes. Since then, a considerable amount of knowledge has been gained in using these sensors in ground test facilities and space. However, these commercially available sensors were too large in scale and weight. Consequently, a new development of solid electrolyte sensors called FIPEX more feasible for space was initiated. Due to space driven benefits, interest arose to use FIPEX technique in terrestrial applications e.g. to monitor sputter plants for float glass coating. Therefore, the VacuSen registered sensor was developed. The characterization of VacuSen registered at nominal sensor temperature T{sub S} = 680 deg. C resulted in a sensor current according to I{sub S} = b{center_dot}p{sub O2}{sup 0{center_dot}8{+-}0{center_dot}05} I[{mu}A] in the operation range between p{sub tot} = 1{center_dot}10{sup -3} to 5 Pa. From pulse width modulation (PWM) temperature control, additional information allows to measure ptot according to p{sub tot} = a{center_dot}RPWM{sup 0{center_dot}107{+-}0{center_dot}005} thus enlarging the operation range to p{sub tot} = 1{center_dot}10{sup -3} to 1{center_dot}10{sup 5} Pa. A one point calibration routine with air, ideally at p{sub tot} = 5 Pa in order to determine both calibration parameters a and b simultaneously, is proposed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Corrosion detector apparatus for universal assessment of pollution in data centers

A compact corrosion measurement apparatus and system includes an air fan, a corrosion sensor, a temperature sensor, a humidity sensor, a heater element, and an air flow sensor all under control to monitor and maintain constant air parameters in an environment and minimize environmental fluctuations around the corrosion sensor to overcome the variation commonly encountered in corrosion rate measurement. The corrosion measurement apparatus includes a structure providing an enclosure within which are located the sensors. Constant air flow and temperature is maintained within the enclosure where the corrosion sensor is located by integrating a variable speed air fan and a heater with the corresponding feedback loop control. Temperature and air flow control loops ensure that corrosivity is measured under similar conditions in different facilities offering a general reference point that allow a one to one comparison between facilities with similar or different pollution levels.

47 OTHER INSTRUMENTATION↗

NREL Hydrogen Sensor Testing Laboratory

Relevance: Detection is recognized as a critical element for hydrogen facility safety design and supports risk mitigation. Detection methodologies will support validation of H2 behavior research. Hydrogen point sensors play a critical role for safety and process monitoring, but other methodologies can be developed. Approach: NREL Sensor Laboratory tests and verifies sensor performance for manufacturers, developers, end-users, regulatory agencies and SDOs/CDOs NREL deployment activity supports regulatory requirement verification, hydrogen behavior models, and method development for use by stakeholders. Accomplishments and Progress: NREL's R&D accomplishments have supported developers, industry, and SDOs by providing sensor performance and deployment expertise not otherwise available. Development of alternative detection strategies for hydrogen applications have been initiated. HyWAM and advanced detection methodologies deployments at H2@Scale Facilities are being implemented. Collaborations: Collaboration with government laboratories, universities, private organizations and regulatory agencies has leveraged the NREL Sensor Laboratory's success in advancing hydrogen safety sensors and process control. Proposed Future Work: NREL will support hydrogen deployment by the proper implementation of hydrogen sensors and advanced detection strategies. NREL will continue to support science-based codes and standards. This effort will be guided by the needs of the hydrogen community.

codes and standards↗

Engine control system having fuel-based timing

A control system for an engine having a cylinder is disclosed having an engine valve movable to regulate a fluid flow of the cylinder and an actuator associated with the engine valve. The control system also has a sensor configured to generate a signal indicative of an amount of an air/fuel mixture remaining within the cylinder after completion of a first combustion event and a controller in communication with the actuator and the sensor. The controller may be configured to compare the amount with a desired amount, and to selectively regulate the actuator to adjust a timing of the engine valve associated with a subsequent combustion event based on the comparison.

33 ADVANCED PROPULSION SYSTEMS↗

Detecting Payload Attacks on Programmable Logic Controllers (PLCs)

Programmable logic controllers (PLCs) play critical roles in industrial control systems (ICS). Providing hardware peripherals and firmware support for control programs (i.e., a PLC’s “payload”) written in languages such as ladder logic, PLCs directly receive sensor readings and control ICS physical processes. An attacker with access to PLC development software (e.g., by compromising an engineering workstation) can modify the payload program and cause severe physical damages to the ICS. To protect critical ICS infrastructure, we propose to model runtime behaviors of legitimate PLC payload program and use runtime behavior monitoring in PLC firmware to detect payload attacks. By monitoring the I/O access patterns, network access patterns, as well as payload program timing characteristics, our proposed firmware-level detection mechanism can detect abnormal runtime behaviors of malicious PLC payload. Using our proof-of-concept implementation, we evaluate the memory and execution time overhead of implementing our proposed method and find that it is feasible to incorporate our method into existing PLC firmware. In addition, our evaluation results show that a wide variety of payload attacks can be effectively detected by our proposed approach. The proposed firmware-level payload attack detection scheme complements existing bumpin- the-wire solutions (e.g., external temporal-logic-based model checkers) in that it can detect payload attacks that violate realtime requirements of ICS operations and does not require any additional apparatus.

42 ENGINEERING↗

Optoelectronic polymer memristors with dynamic control for power-efficient in-sensor edge computing

Abstract As the demand for edge platforms in artificial intelligence increases, including mobile devices and security applications, the surge in data influx into edge devices often triggers interference and suboptimal decision-making. There is a pressing need for solutions emphasizing low power consumption and cost-effectiveness. In-sensor computing systems employing memristors face challenges in optimizing energy efficiency and streamlining manufacturing due to the necessity for multiple physical processing components. Here, we introduce low-power organic optoelectronic memristors with synergistic optical and mV-level electrical tunable operation for a dynamic “control-on-demand” architecture. Integrating signal sensing, featuring, and processing within the same memristors enables the realization of each in-sensor analogue reservoir computing module, and minimizes circuit integration complexity. The system achieves 97.15% fingerprint recognition accuracy while maintaining a minimal reservoir size and ultra-low energy consumption. Furthermore, we leverage wafer-scale solution techniques and flexible substrates for optimal memristor fabrication. By centralizing core functionalities on the same in-sensor platform, we propose a resilient and adaptable framework for energy-efficient and economical edge computing.

Optics↗

Current Observer Based Predictive Decoupled Power Control Grid-Interactive Inverter

This paper presents a sensor-less current model predictive control (MPC) scheme via a full state observer based current estimator. The grid interactive inverters’ control schemes require current and voltage sensors. Elimination of current sensor enhances the inverter reliability. This paper leverages the inherent characteristics of MPC towards robust current sensor-less grid interactive inverter with LC filter. The observer for inductor current is developed based on the existing capacitor voltage measurement. The estimator dynamic state-space matrices are then obtained through reconstruction of the inverter model with the capacitor voltage and inductor current being the state variables. The controller objectives are to regulate active and reactive power in a decoupled manner. The theoretical expectation, controller performance, and accuracy of the current estimation are verified by conducting a real-time simulation via Typhoon HIL.

Zhang, Zhen↗

Mercury Detection Utilizing an Aquatic Animal as a Remote-Sensing Platform

Mercury species in open water, especially the accumulated methylmercury ion, pose a threat to fish and environment. Therefore, it is important to develop a small sensor package that can be integrated into a biotelemetry sensor carried by an aquatic animal, enhancing the ability to detect mercury contamination in large water areas. A quartz crystal microbalance (QCM) sensor using metal-organic framework (MOF) as sensing material was developed to detect mercury and methylmercury ions in real time based on acoustic wave perturbation. Thiol groups were introduced into the MOF UiO-66 through the organic linker to prepare the UiO-66-SH which was confirmed by infrared spectroscopy results. Batch adsorption experiments were conducted for the Hg 2+ , CH 3 Hg + , and Ca 2+ ions adsorption in the UiO-66-SH. The adsorption capacities of the mercury ions were more than an order of magnitude higher than those of the competing Ca 2+ ions at the same concentration. The frequency changes of the QCM sensor with the UiO-66-SH sensing film were an order of magnitude higher than those of the controlled baseline QCM sensor without a sensing film. Additionally, the frequency change can be tailored by adjusting the thickness of the MOF film and the adsorption properties of the sensing material. The sensor frequency change correlates well with ion adsorption capacities.

47 OTHER INSTRUMENTATION↗

A Robust Method to Secure Multi-Inverter Grid Tied PV and Battery Energy Storage Systems Against Cyber Intrusions

This paper details a robust method to secure a multi-inverter grid tied system that interfaces photovoltaic (PV) and battery energy storage against potential cyber-attacks. The method can be applied to any third-party inverter systems without a need to modify their internal controls. A small random private excitation signal termed "watermark" is injected into the DC input voltage terminals (via a series transformer) connected to the PV/battery inverter system. An external robust cyber intrusion detector (CID) hardware consisting of a digital signal processor (DSP) generates the "watermark" and also receives the sensor signals that control the setpoints of the PV/battery grid tied system. The CID algorithm is shown to detect all possible cyber intrusions (such as false data injection(FDI)) on external sensor signals such as P and Q measured by a smart meter that control the overall system operation. The proposed CID computes online system ID and two variance tests in real time on each sensor signal and is able pinpoint intrusion location in a multi-inverter system. Results on a hardware in the loop (HIL) of a two-inverter grid connected system demonstrate effectiveness of the proposed CID system for FDI and unobservable FDI. Test results on a laboratory prototype will be discussed in the conference presentation.

Ibrahim, Hasan↗

Response characteristics of stable mixed-potential NH 3 sensors in diesel engine exhaust

Here, a mixed-potential, electrochemical sensor platform is extended to NH 3 sensing by the introduction of a new gold alloy working electrode. A planar, pre-commercial NH 3 sensor utilized LANL’s controlled interface approach, and a Pd-Au alloy working electrode was tested in exhaust of a GM 1.9 L diesel engine downstream of a diesel oxidation catalyst through a slipstream arrangement. A fraction of the exhaust was pulled across the sensor with a pump at 20 L/min. In order to simulate NH 3 slip inside of a full SCR emissions control system, NH 3 was injected immediately upstream of the sensor using a calibrated mass flow controller. The sensor response quantitatively tracked the NH 3 as measured via Fourier transform infrared (FTIR) analyzer. A calibration curve was obtained in the exhaust from an ammonia staircase response with the engine running at steady-state engine conditions resulting in low background concentrations of NO x and HC (<20 ppm) during calibration. Exhaust gas recirculation (EGR) switching and sweeps were used to evaluate the NH 3 sensor response under different amounts of total background NO x . The calibration curve was used to directly compare the [NH 3 ] calculated from sensor response to the gas phase composition measured via FTIR. In general, there was excellent quantitative agreement between the sensor response and the actual NH 3 in the exhaust gas, and fast response time such that transients (<5 ppm) could be easily discerned from baseline. A LANL pre-commercial NO x sensor was tested simultaneously with the NH 3 sensor and the extent of cross-sensitivity between the two sensors will be discussed.

47 OTHER INSTRUMENTATION↗

Review of Electrical Architectures and Power Requirements for Automated Vehicles

Automated vehicles require sensors and computer processing that can perceive the surrounding environment and make real time decisions. These additional electrical loads expand the auxiliary load profile, therefore reducing the range of an automated electric vehicle compared to a standard electric vehicle. Furthermore, a fully automated vehicle must be fail-safe from sensor to vehicle control, thus demanding additional electrical loads due to redundancies in hardware throughout the vehicle. This paper presents a review of the sensors needed to make a vehicle automated, the power required for these additional auxiliary loads, and the necessary electrical architectures for increasing levels of robustness.

Baxter, Jared↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

Digital Twin for Hydropower System Object Modeling: Alder Dam (FY2023)

Hydropower is the world's largest source of renewable electricity, and hydropower plants are distributed all over the world. Typical major components of a hydropower plant are the governor, excitation, generator, thrust bearing, hydraulic turbine, transformer, the main lead, metering and control, tailwater depression, and dissolved oxygen. For each component, various measures are taken. The measurements are acquired by various heterogeneous systems, including standalone sensors, programmable logic controllers (PLC), Supervisory control and data acquisition (SCADA), Internet of Things (IoT), and data acquisition and integration platforms such as OSI/PI. The measured data are often archived within the plant by a data management platform, and many institutions have cloud-based archive systems, such as Hydropower Research Institution (HRI), U.S. Army Corps of Engineers (USACE), and Columbia River Data Access in Real Time (DART). Object Modeling is a general framework for designing information systems. It focuses on objects, the actions they perform, and the messages they send to one another to cause those actions to be taken. The major differences among object modeling, network modeling, data modeling, and process modeling are that in the first we focus on the actions in response to information, objects which form the system, the actions they perform, and how they pass information to one another, while in the second we concentrate on where, when and how much information is moved, while in the third we focus on what information is moved and where it is moved, while in the last we focus on how it is moved and when it is moved. Object modeling was developed basically as a method to develop object-oriented systems and to support object-oriented programming. It describes the static structure of the system. The object Modeling Technique is easy to draw and use. That is why we choose object modeling to connect physical hydropower plants to Digital Twin. It recognizes the objects and the relationship between them. It identifies the attributes and functions of each class. Dynamic Modeling: It explains how objects respond to events. Functional Modeling indicates the processes executed in an object and how data changes when it moves to objects. It has been used in many applications like telecommunication, transportation, etc.

13 HYDRO ENERGY↗

Automated cryogenic refilling system

An improved system and method for the automated refilling of cryogenic helium is provided. In one embodiment, the system includes a dewar in fluid communication with a liquid helium cryostat through a cryogen transfer line. A controller regulates operation of a three-way valve to pre-cool the transfer line and to cause gaseous helium to flow to the dewar and force liquid helium through the transfer line into the cryostat. The controller is coupled to the output of a cryogenic level sensor, such that the controller regulates the helium liquid level within the cryostat. During filling cycles, the dewar liquid level is also monitored by the cryogenic level sensor and an alarm sounds if the dewar liquid level is undesirably low. Between filling cycles, the controller is operable to ventilate the dewar through a solenoid vent valve in fixed time intervals to ensure the dewar pressure is sufficiently low so as to not bleed liquid helium into the cryostat.

Ruiz-Rodriguez, Mariano M.↗