Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time-Of-Flight Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Application of a Chemical Index to Aerosol Mass Spectrometry: Delta Plots and Functional Group Distributions

A better understanding of the chemical properties of organic aerosol (OA) particles will improve our ability to characterize their sources and predict their lifetime. The high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA in real time using thermal vaporization followed by electron ionization (EI). EI creates fragment ions that can be assigned to functional groups using delta analysis, a method of classifying mass spectra according to the presence of different chemically related ion series. In this study, we demonstrate the application of delta analysis to characterize molecular structures using a new visualization method. We also use delta analysis to quantify the functional group distribution with an average absolute error of ∼5–6% for individual standard molecules, comparable to the error observed for OA mixtures from biomass and coal combustion fit with Fourier transform infrared spectroscopy. Finally, we apply delta functional group analysis to AMS positive matrix factorization (PMF) factors across seven different field campaigns and find a similar composition across the more oxidized factors with about 55% acid and 26% alcohol groups. The analysis method described here can be applied to any HR-ToF-AMS data set to provide quantitative relative functional group distributions for OA mixtures.

aerosol↗

TOFHunter—unlocking rapid untargeted screening of inductively coupled plasma–time-of-flight–mass spectrometry data

This study provides an overview of a newly developed open source program written in Python, TOFHunter, which permits the rapid and untargeted screening of inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) datasets. ICP-TOF-MS is an analytical tool capable of providing quasi simultaneous detection of all nuclides from Li to Pu. This capability has triggered an increase in studies investigating single-particle analysis in which the TOF-MS provides correlated elemental/isotopic signatures on a particle basis in time. Similarly, laser ablation mapping has seen rapid growth owing to ICP-TOF-MS's capacity to handle fast washout times (<10 ms) while providing a broad nuclide coverage. The caveat to this broad mass coverage and high time resolution comes in the form of large, overwhelming datasets. With datasets typically on the scale of gigabytes, it is easy for a user to only focus on very targeted analytes; however, this focus diminishes the opportunity offered by the TOF-MS detector. TOFHunter applies chemometric methods, principal component analysis (PCA), and interesting features finder (IFF) on ICP-TOF-MS data, allowing for investigation of correlations, major and minor variance sources, and sample screening. The unique spectra identified by the (IFF) are used to generate a list of mass peaks, which are then matched with both nuclides and potential interferences before being exported for the user to investigate. Several case studies are discussed herein, demonstrating TOFHunter's ability to screen aqueous injections, single-particle/single-cell analysis, and probe laser ablation mapping files for unique regions of interest.

47 OTHER INSTRUMENTATION↗

Average neutron time-of-flight instrument response function inferred from single D-T neutron events within a plastic scintillator

The apparent ion temperature and neutron-reaction history are important characteristics of a fusion plasma. Extracting these quantities from a measured neutron-time-of-flight signal requires accurate knowledge of the instrument response function (IRF). This paper describes a novel method for obtaining the IRF directly for single DT neutron interactions by utilizing n-alpha coincidence. The t(d,α)n nuclear reaction was produced at Sandia National Laboratories’ Ion Beam Laboratory using a 300 keV Cockcroft-Walton generator to accelerate a 2.5 μA beam of 175 keV D + ions into a stationary ErT 2 target. The average neutron IRF was calculated by taking a time-corrected average of individual neutron events within an EJ-228 plastic scintillator. The scintillator was coupled to two independent photo-multiplier tubes operated in the current mode: a Hamamatsu 5946 mod-5 and a Photek PMT240. Finally, the experimental setup and results will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ab initio response functions for Cherenkov-based neutron detectors

Neutron time-of-flight diagnostics at the NIF were of late outfitted with Cherenkov detectors. A fused silica radiator delivers sub-nanosecond response time and is optically coupled to a microchannel plate photomultiplier tube with gain from ~1 to 10 4 . Capitalizing on fast time response and gamma-ray sensitivity, these systems can provide better than 30 ps precision for measuring first moments of neutron distributions. Generation of ab initio instrument response functions (IRFs) is critical to meet the <1% uncertainty needed. A combination of Monte Carlo modeling, benchtop characterization, and in situ comparison is employed. Close agreement is shown between the modeled IRFs and in situ measurements using the NIF’s short-pulse advanced radiographic capability beams. First and second moments of neutron spectra calculated using ab initio IRFs agree well with established scintillator measurements. Next-step designs offer increased sensitivity and time-response.

47 OTHER INSTRUMENTATION↗

Design of a multi-detector, single line-of-sight, time-of-flight system to measure time-resolved neutron energy spectra

In the dynamic environment of burning, thermonuclear deuterium–tritium plasmas, diagnosing the time-resolved neutron energy spectrum is of critical importance. Strategies exist for this diagnosis in magnetic confinement fusion plasmas, which presently have a lifetime of ~10 12 longer than inertial confinement fusion (ICF) plasmas. In this work, we present a novel concept for a simple, precise, and scale-able diagnostic to measure time-resolved neutron spectra in ICF plasmas. The concept leverages general tomographic reconstruction techniques adapted to time-of-flight parameter space, and then employs an updated Monte Carlo algorithm and National Ignition Facility-relevant constraints to reconstruct the time-evolving neutron energy spectrum. Reconstructed spectra of the primary 14.028 MeV n DT peak are in good agreement with the exact synthetic spectra. The technique is also used to reconstruct the time-evolving downscattered spectrum, although the present implementation shows significantly more error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of a spatially resolved ion temperature diagnostic for inertial confinement fusion

Here, the performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium–tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing drift velocity dispersion in MAPbI 3 photovoltaic cells with nonlinear photocurrent spectroscopy

Conventional time-of-flight (TOF) measurements yield charge carrier mobilities in photovoltaic cells with time resolution limited by the RC time constant of the device, which is on the order of 0.1–1 µs for the systems targeted in the present work. We have recently developed an alternate TOF method, termed nonlinear photocurrent spectroscopy (NLPC), in which carrier drift velocities are determined with picosecond time resolution by applying a pair of laser pulses to a device with an experimentally controlled delay time. In this technique, carriers photoexcited by the first laser pulse are “probed” by way of recombination processes involving carriers associated with the second laser pulse. Here, we report NLPC measurements conducted with a simplified experimental apparatus in which synchronized 40 ps diode lasers enable delay times up to 100 µs at 5 kHz repetition rates. Carrier mobilities of ∼0.025 cm 2 /V/s are determined for MAPbI 3 photovoltaic cells with active layer thicknesses of 240 and 460 nm using this instrument. Here, our experiments and model calculations suggest that the nonlinear response of the photocurrent weakens as the carrier densities photoexcited by the first laser pulse trap and broaden while traversing the active layer of a device. Based on this aspect of the signal generation mechanism, experiments conducted with co-propagating and counter-propagating laser beam geometries are leveraged to determine a 60 nm length scale of drift velocity dispersion in MAPbI 3 films. Contributions from localized states induced by thermal fluctuations are consistent with drift velocity dispersion on this length scale.

14 SOLAR ENERGY↗

Ionizing photon interactions modulate the optical properties of crystals with femtosecond scale temporal resolution

In this work, we continue our study of a new method for the detection of ionizing radiation with the potential for a dramatic improvement in coincidence time resolution (CTR) for time-of-flight positron emission tomography (ToF-PET) using the modulation of a material's optical properties instead of the scintillation mechanism. Our previous work has shown that for non-scintillation materials such as bismuth silicon oxide (BSO) and cadmium telluride (CdTe), their refractive index can be modulated by annihilation photon interactions. Additionally, the ultrafast nature of this process however remains unexplored. The ionizing radiation-induced charge carriers alter the local band structure in these materials, thus changing the complex refractive index. This mechanism is routinely used at the linac coherent light source (LCLS) facility of the SLAC National Accelerator Laboratory to measure x-ray pulse arrival times with femtosecond scale resolution for photon energies between 0.5 and 10 keV. The method described here follows that example by using a frequency chirped visible continuum pulse to provide a monotonic wavelength-to-time mapping by which one can measure the time-dependent refractive index modulation. In addition, we describe an interference-based measurement setup that allows for significantly improved sensitivity while preserving a timing precision of approximately 10 fs (σ) when measuring the arrival time of below 10 keV x-ray pulses with yttrium aluminum garnet (YAG) crystal. The method is presented in the context of ToF-PET application with further discussions on the potential CTR achievable if a similar detection concept is adopted for detecting 511 keV photons. Semi-empirical analysis indicates that the predicted CTR achievable is on the order of 1 ps (FWHM).

59 BASIC BIOLOGICAL SCIENCES↗

Pulse shape measurements for neutron/gamma discrimination using the TOFPET2 ASIC

Many highly pixelated organic scintillator detection systems would benefit from independent readout of each scintillator pixel. Recent advances in Silicon Photomultiplier (SiPM) technology makes this goal feasible, however the data acquisition from potentially hundreds or thousands of channels requires a low-cost and compact solution. For pixelated neutron detection with organic scintillators, the capability to distinguish between neutron and gamma interactions using Pulse Shape Discrimination (PSD) is required along with pulse charge and time of arrival. The TOFPET2 ASIC from PETsys Electronics is a 64-channel readout chip providing pulse time and charge integration measurements from SiPMs, and is specifically designed for time-of-flight positron-emission tomography. Using an 8 × 8 array of 6 mm × 6 mm J-series SiPMs from SensL/OnSemi (ArrayJ-60035-64P-PCB), we have studied the energy and PSD performance of the TOFPET2 ASIC using a 4 × 4 array of 6 mm × 6 mm × 30 mm trans -Stilbene crystals from Inrad Optics and a custom SiPM routing board from PETsys Electronics. In conclusion, using a time-over-threshold method, we measure a maximum PSD figure-of-merit of approximately 1.2 at 478 keV (the Compton edge of 662 keV) for a J-series SiPM operating at an over-voltage of 3V.

47 OTHER INSTRUMENTATION↗

High resolution measurement of tagged two-neutron energy and angle correlations in 252-Cf (sf)

Spontaneous fission events emit prompt neutrons correlated with one another in emission angle and energy. Measurements of these correlations can shed light on the partitioning of the excitation energy between the fragments, even if they are not directly measured. Purpose: We explore the relationship in energy and angle between correlated prompt neutrons emitted from 252 Cf spontaneous fission. Methods: Measurements with the Chi-Nu array provide experimental data for coincident neutrons tagged with a fission chamber signal with 10° angular resolution and 1-ns timing resolution for time-of-flight energy calculations. The experimental results are compared to simulations produced by the fission event generators cgmf, freya, and mcnpx-polimi ipol(1) = 1. Results: We find that the measurements and the simulations all exhibit anisotropic neutron emission, although differences between fission event generators are evident. In conclusion, this work shows that the dependence of detected neutron energy on the energy of another neutron detected in coincidence, although weak, is non-negligible, indicating that there may be correlations in energy between two neutrons emitted in the same fission event..

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision pulse shape simulation for proton detection at the Nab experiment

The Nab experiment at Oak Ridge National Laboratory, USA, aims to measure the beta-antineutrino angular correlation following neutron β decay to an anticipated precision of approximately 0.1%. The proton momentum is reconstructed through proton time-of-flight measurements, and potential systematic biases in the timing reconstruction due to detector effects must be controlled at the nanosecond level. In conclusion, we present a thorough and detailed semiconductor and quasiparticle transport simulation effort to provide precise pulse shapes, and report on relevant systematic effects and potential measurement schemes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pressure cells for in situ neutron total scattering: time and real-space resolution during deuterium absorption

In situ gas-loading sample holders for two-dimensionally arranged detectors in time-of-flight neutron total scattering experiments have been developed to investigate atomic arrangements during deuterium absorption using time and real-space resolution. A single-crystal sapphire container was developed that allows conditions of 473 K and 10 MPa hydrogen gas pressure. High-resolution transient measurements detected deuterium absorption by palladium that proceeded within a few seconds. A double-layered container with thick- and thin-walled vanadium allowed conditions of 423 K and 10 MPa hydrogen gas pressure. The deuterium occupation sites of a lanthanum–nickel–aluminium alloy are discussed in detail on the basis of real-space high-resolution data obtained from in situ neutron scattering measurements and reverse Monte Carlo structural modeling.

08 HYDROGEN↗

Time Resolution Measurements of EJ-232Q With Single- and Dual-Sided Readouts

In view of its importance to applications in high energy physics, nuclear security, and time-of-flight PET, the time resolution of 0.5% benzophenone-quenched EJ-232Q plastic scintillators of various lengths was studied using a fast waveform digitizer and fast PMTs. The scintillator sizes were 5 mm × 5 mm × 10, 25, 50, 75, or 100 mm. First, the timing measurements were performed by using a single PMT reading out one end. The degradation in time resolution with increasing scintillator length was studied. The irradiation geometry was also observed to have a non-negligible impact on the time resolution due to the variation of depth-of-interaction positions, especially for the scintillators with a high aspect ratio. Second, two PMTs were employed for a dual-sided readout. This readout together with the mean time method was demonstrated to be an effective approach to improve the timing performance since the depth-of-interaction-related effect was considerably mitigated. A time resolution of 79 ± 1 ps (full-width at half-maximum) has been achieved for the 5 × 5 × 10 mm 3 scintillator. The 5 × 5 × 100 mm 3 scintillator can still provide a time resolution as good as 172 ± 1 ps. Here, the energy range used for each was between 340 keVee and 450 keVee. In addition, the time information from individual PMTs in a dual-sided readout was able to show a time resolution almost identical to that determined with the mean-time-based technique after correcting for the depth-of-interaction variation for the 100 mm long scintillator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deep learning-based temporal deconvolution for photon time-of-flight distribution retrieval

The acquisition of the time of flight (ToF) of photons has found numerous applications in the biomedical field. Over the last decades, a few strategies have been proposed to deconvolve the temporal instrument response function (IRF) that distorts the experimental time-resolved data. However, these methods require burdensome computational strategies and regularization terms to mitigate noise contributions. Herein, we propose a deep learning model specifically to perform the deconvolution task in fluorescence lifetime imaging (FLI). The model is trained and validated with representative simulated FLI data with the goal of retrieving the true photon ToF distribution. Its performance and robustness are validated with well-controlled in vitro experiments using three time-resolved imaging modalities with markedly different temporal IRFs. The model aptitude is further established with in vivo preclinical investigation. Overall, these in vitro and in vivo validations demonstrate the flexibility and accuracy of deep learning model-based deconvolution in time-resolved FLI and diffuse optical imaging.

Pandey, Vikas (ORCID:0000000154771095)↗

An Evaluation of Bang-Time Measurements from a Multichannel, Triaxial, nTOF Diagnostic for MagLIF Experiments at the Z facility

Neutron bang times for a series of MagLIF (Magnetic Liner Inertial Fusion) experiments with D 2 -filled targets have been measured at the Z facility. The emitted neutrons were detected as current-mode pulses in a multichannel, neutron time-of-flight (nTOF) diagnostic with conventional, scintillator-photomultiplier-tube (PMT) detectors. In these experiments, the detectors were fielded at known, fixed distances L (690-2510 cm) from the target, and on three, non-coplanar (but convergent) lines-of-sight (LOS). The primary goal of this diagnostic was to estimate a fiducial time (bang time) relative to an externally generated time-base for synchronizing all the diagnostics in an experiment. Recorded arrival times (A7) of the pulses were characterized experimentally by three numerical methods: a first-moment estimate (centroid) and two nodal measures — Savitzky-Golay (SG) smoothing and a single point peak estimate of the raw data. These times were corrected for internal detector time delays (transit and impulse-response function) — an adjustment that linked the recorded ATs to the corresponding arrival of uncollided neutrons at each detector. The bang time was then estimated by linearly regressing the arrival times against the associated distances to the source; t bang (on the system timescale) was taken as the temporal intercept of the regression equation at distance L = 0. This article reports the analysis for a representative shot #2584 for which (a) the recorded ATs — even without detector corrections — agreed by method in each channel to within 1-2 ns; (b) internal corrections were each ~3 — 5 ns; and (c) a 95% uncertainty (confidence) interval for t bang in this shot was estimated at ±3 ns with 4 degrees of freedom. A secondary goal for this diagnostic was to check that the bang time measurements corresponded to neutrons emitted by the D(d,n) 3 He reaction in a thermalized DD plasma. According to the theoretical studies by Brysk, such neutrons should be emitted with an isotropic Gaussian distribution of mean kinetic energy $ \overline{E}$ of 2.449 MeV; this energy translates to a mean neutron speed $ \overline{u}$ of 2.160 cm/ns [D. H. Munro, Nuclear Fusion, 56(3) 036001 (2016)]. In the MagLIF series of shots there was no evidence of spatial asymmetry in the time-distance regressions, and it was possible to extract the mean neutron speed from the slope of these fits. In shot 2584 $ \overline{u}$ was estimated at 2.152 cm/ns ± 0.010 cm/ns [95 % confidence, 4 dof] and the mean kinetic energy $ \overline{E}$ (with relativistic corrections) was 2.431 MeV ± 0.022 MeV [95 % confidence, 4 dof] — results supporting the assumption that D-D neutrons were, in fact, measured.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Epithermal Neutron Resonance Analysis Using a Compact D-T Generator

Nuclear material identification and isotopic composition analysis are important capabilities for safeguards and the verification of nuclear arms control and nonproliferation treaties. Epithermal neutron resonance imaging has been proposed for spent fuel assay measurements, and the development of a mobile neutron imaging system could provide such a tool for on-site applications. This technique is highly sensitive to isotopes of interest for safeguards applications (e.g. 235,238 U, 238,239,240 Pu) and yields unique transmission spectra for a target containing actinides and some mid- and high-Z elements. Paired with a position-sensitive neutron detector, such a system could provide spatial information of the target isotopic composition. Recent progress in the development of high intensity neutron sources could make mobile epithermal neutron imaging designs increasingly feasible to serve as a tool for nuclear inspectors. In this work, Monte Carlo (MC) simulations were performed to further optimize a previous design for an epithermal neutron resonance-based analysis apparatus using a D-T portable neutron generator. Additionally, experimental work is being performed to test the feasibility of this method. The MC simulations of moderation time distributions for different moderator compositions and thicknesses were measured to provide a multi-group correction for neutron time-of-flight energy reconstruction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular composition and volatility of isoprene photochemical oxidation secondary organic aerosol under low- and high-NO<sub><i>x</i></sub> conditions

Abstract. We present measurements of secondary organic aerosol (SOA) formation from isoprene photochemical oxidation in an environmental simulation chamber at a variety of oxidant conditions and using dry neutral seed particles to suppress acid-catalyzed multiphase chemistry. A high-resolution time-of-flight chemical ionization mass spectrometer (HR-ToF-CIMS) utilizing iodide-adduct ionization coupled to the Filter Inlet for Gases and Aerosols (FIGAERO) allowed for simultaneous online sampling of the gas and particle composition. Under high-HO2 and low-NO conditions, highly oxygenated (O : C ≥ 1) C5 compounds were major components (∼ 50 %) of SOA. The SOA composition and effective volatility evolved both as a function of time and as a function of input NO concentrations. Organic nitrates increased in both the gas and particle phases as input NO increased, but the dominant non-nitrate particle-phase components monotonically decreased. We use comparisons of measured and predicted gas-particle partitioning of individual components to assess the validity of literature-based group-contribution methods for estimating saturation vapor concentrations. While there is evidence for equilibrium partitioning being achieved on the chamber residence timescale (5.2 h) for some individual components, significant errors in group-contribution methods are revealed. In addition, > 30 % of the SOA mass, detected as low-molecular-weight semivolatile compounds, cannot be reconciled with equilibrium partitioning. These compounds desorb from the FIGAERO at unexpectedly high temperatures given their molecular composition, which is indicative of thermal decomposition of effectively lower-volatility components such as larger molecular weight oligomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗