Search NASA⌕ Search

SEARCH · Search NASA

Results for “VOLUME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Quantifying the atomistic free-volume morphology of materials with graph theory

Here, we introduce a new computational methodology for the identification and characterization of free volume within/around atomistic configurations. This scheme employs a three-stage workflow, by which spheres are iteratively grown inside of voxels, and ultimately converted to planar graphs, which are then characterized via a graph-based order parameter. Our approach is computationally efficient, physically intuitive, and universally transferable to any material system. Validation of our methodology is performed on several sets of materials problems: (1) classification of unique free volumes in various crystal phases, (2) autonomous detection and classification of complex surface defects during epitaxial growth simulations, (3) characterization of free volume defects in metals/alloys, and (4) quantification of the spatio-temporal behavior of nano-scale free volume morphologies as a function of both temperature and free-volume size. Our method accurately identifies and characterizes unique free volumes over a multitude of systems and length scales, indicating its potential for future use in understanding the relationship between free volume morphology and material properties under both static and dynamic conditions.

36 MATERIALS SCIENCE↗

Tumor Volume Is a Prognostic Factor in Non-Small-Cell Lung Cancer Treated With Chemoradiotherapy

Purpose: To investigate whether primary tumor and nodal volumes defined on radiotherapy planning scans are correlated with outcome (survival and recurrence) after combined-modality treatment. Methods and Materials: A retrospective review of patients with Stage III non-small-cell lung cancer treated with chemoradiation at Brigham and Women's Hospital/Dana-Farber Cancer Institute from 2000 to 2006 was performed. Tumor and nodal volume measurements, as computed by Eclipse (Varian, Palo Alto, CA), were used as independent variables, along with existing clinical factors, in univariate and multivariate analyses for association with outcomes. Results: For patients treated with definitive chemoradiotherapy, both nodal volume (hazard ratio [HR], 1.09; p < 0.01) and tumor volume (HR, 1.03; p < 0.01) were associated with overall survival on multivariate analysis. Both nodal volume (HR, 1.10; p < 0.01) and tumor volume (HR, 1.04; p < 0.01) were also associated with local control but not distant metastases. Conclusions: In addition to traditional surgical staging variables, disease burden, measured by primary tumor and nodal metastases volume, provides information that may be helpful in determining prognosis and identifying groups of patients for which more aggressive local therapy is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new method to estimate the atomic volume of ternary intermetallic compounds

The atomic volume of an A{sub x}B{sub y}C{sub z} ternary intermetallic compound can be calculated starting from volumes of some proper A-B, A-C and B-C binary phases. The three methods by Colinet, Muggianu and Kohler, originally used to estimate thermodynamic quantities, and a new method here proposed, were tested to derive volume data in eight systems containing 91 ternary phases with the known structure. The comparison between experimental and calculated volume values shows the best agreement both for the Kohler method and for the new proposed procedure. -- Graphical abstract: Synopsys: the volume of a ternary intermetallic compound can be calculated starting from volumes of some binary phases, selected by the methods of Colinet, Muggianu, Kohler and a new method proposed here. The so obtained values are compared with the experimental ones for eight ternary systems. Display Omitted Research highlights: {yields} The application of some thermodinamic methods to a crystallochemical problem. {yields} The prevision of the average atomic volume of ternary intermetallic phases. {yields} The proposal of a new procedure to select the proper starting set of binary phases.

36 MATERIALS SCIENCE↗

Factors Affecting Prostate Volume Estimation in Computed Tomography Images

The aim of this study was to investigate how apex-localizing methods and the computed tomography (CT) slice thickness affected the CT-based prostate volume estimation. Twenty-eight volunteers underwent evaluations of prostate volume by CT, where the contour segmentations were performed by three observers. The bottom of ischial tuberosities (ITs) and the bulb of the penis were used as reference positions to locate the apex, and the distances to the apex were recorded as 1.3 and 2.0 cm, respectively. Interobserver variations to locate ITs and the bulb of the penis were, on average, 0.10 cm (range 0.03-0.38 cm) and 0.30 cm (range 0.00-0.98 cm), respectively. The range of CT slice thickness varied from 0.08-0.48 cm and was adopted to examine the influence of the variation on volume estimation. The volume deviation from the reference case (0.08 cm), which increases in tandem with the slice thickness, was within {+-} 3 cm{sup 3}, regardless of the adopted apex-locating reference positions. In addition, the maximum error of apex identification was 1.5 times of slice thickness. Finally, based on the precise CT films and the methods of apex identification, there were strong positive correlation coefficients for the estimated prostate volume by CT and the transabdominal ultrasonography, as found in the present study (r > 0.87; p < 0.0001), and this was confirmed by Bland-Altman analysis. These results will help to identify factors that affect prostate volume calculation and to contribute to the improved estimation of the prostate volume based on CT images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Evaluation Studies↗

Conjunction Assessment Screening Volume Sizing and Event Filtering in Light of Natural Conjunction Event Development Behaviors

Conjunction Assessment screening volumes used in the protection of NASA satellites are constructed as geometric volumes about these satellites, of a size expected to capture a certain percentage of the serious conjunction events by a certain time before closest approach. However, the analyses that established these sizes were grounded on covariance-based projections rather than empirical screening results, did not tailor the volume sizes to ensure operational actionability of those results, and did not consider the adjunct ability to produce data that could provide prevenient assistance for maneuver planning. The present study effort seeks to reconsider these questions based on a six-month dataset of empirical screening results using an extremely large screening volume. The results, pursued here for a highly-populated orbit regime near 700 km altitude, identify theoretical limits of screening volume performance, explore volume configuration to facilitate both maneuver remediation planning as well as basic asset protection, and recommend sizing principles that maximize volume performance while minimizing the capture of "chaff" conjunctions that are unlikely ever to become serious events.

screening volume↗

Formalized Reasoning of Operational Volumes for Wildland Fire Fighting

This work is focused on the formalized reasoning of operational volumes as it relates to the current and future technologies developed by NASA to aid in wildfire fighting operations. One such technology is the unmanned aircraft system pilot kit (UASP-kit) developed by the Scalable Traffic Management for Emergency Response Operations (STEReO) project at NASA, which is used to increase situation awareness for a ground operator in the field. The UASP-kit utilizes operational volumes which represent mission areas and alerting volumes, to alert when another aircraft is within one of these volumes from received ADS-B data. This work is focused on developing a rigorous foundation for the concept of operational volumes for modeling and prototyping operations in such a tool as the UASP-kit. This includes establishing a class of algorithms to detect when an object is in an operational volume, and when an operational volume is intersecting or contained within another. Additionally, this work is focused on providing rigorous proof in an interactive theorem prover that the algorithms work as intended. Scenarios are presented that model current UASP-kit operations and extend past the current capabilities of the technology to modeling more complex scenarios such as mission planning.

Operational Volumes↗

Formalized Reasoning of Operational Volumes for Wildland Fire Fighting

This work is focused on the formalized reasoning of operational volumes as it relates to the current and future technologies developed by NASA to aid in wildland firefighting operations. One such technology is the Unmanned Aircraft System Pilot Kit (UASP-kit) developed by the Scalable Traffic Management for Emergency Response Operations (STEReO) project at NASA, which is used to increase situational awareness for a ground operator in the field. The UASP-kit utilizes operational volumes to represent mission areas and alerting volumes; these volumes, in combinations with ADS-B data, can then be used to alert the ground operator when another aircraft has entered one of these areas. This work presents a rigorous foundation for the concept of operational volumes for modeling and prototyping operations in such a tool as the UASP-kit. This includes establishing a class of algorithms to detect when an object is in an operational volume, and when one operational volume intersects or is contained in another. Additionally, this work provides rigorous proof that the algorithms work as intended. Scenarios are presented that model current UASP-kit operations and extend past the current capabilities of the technology to modeling more complex scenarios such as mission planning.

Operational Volumes↗

Estimating Highway Volumes Using Vehicle Probe Data - Proof of Concept: Preprint

This paper examines the feasibility of using sampled commercial probe data in combination with validated continuous counter data to accurately estimate vehicle volume across the entire roadway network, for any hour during the year. Currently either real time or archived volume data for roadways at specific times are extremely sparse. Most volume data are average annual daily traffic (AADT) measures derived from the Highway Performance Monitoring System (HPMS). Although methods to factor the AADT to hourly averages for typical day of week exist, actual volume data is limited to a sparse collection of locations in which volumes are continuously recorded. This paper explores the use of commercial probe data to generate accurate volume measures that span the highway network providing ubiquitous coverage in space, and specific point-in-time measures for a specific date and time. The paper examines the need for the data, fundamental accuracy limitations based on a basic statistical model that take into account the sampling nature of probe data, and early results from a proof of concept exercise revealing the potential of probe type data calibrated with public continuous count data to meet end user expectations in terms of accuracy of volume estimates.

25 ENERGY STORAGE↗

A comparison of segmented abdominopelvic fluid volumes with conventional CT signs of abdominal compartment syndrome in a trauma population

Purpose: To compare the utility of abdominopelvic fluid volume measurements with established computed tomography signs for refractory post-traumatic abdominal compartment syndrome. Methods: This retrospective observational cohort study included 64 consecutive adult trauma patients with preoperative CT and diagnosis of refractory abdominal compartment syndrome requiring decompressive laparotomy at a level I trauma referral center between 2004 and 2014. We hypothesized that abdominal fluid volume measurements would be more predictive of the need for early laparotomy than previously described conventional CT signs of refractory ACS. Abdominopelvic fluid volumes were determined quantitatively using semi-automated segmentation software. The following conventional imaging parameters were recorded: abdominal anteroposterior:transverse ratio (round belly sign); infrahepatic vena cava diameter; distal abdominal aortic diameter; largest single small bowel wall diameter; hydronephrosis, inguinal herniation; and mesenteric and body wall edema. For outcome analysis, patients were stratified into two groups: those who underwent early (< 24 h) and late (≥ 24 h) decompressive laparotomy following CT. Correlation analysis, comparison of means, and multivariate logistic regression were performed. Results: Abdominal fluid volumes (p = 0.001) and anteroposterior:transverse ratio (p = 0.009) were increased and inferior vena cava diameter (p = 0.009) was decreased in the early decompressive laparotomy group. Multivariate analysis including conventional CT variables, fluid volumes, and laboratory values revealed abdominal fluid volumes (p = 0.012; Δ in log odds of 1.002/mL) as the only independent predictor of early decompressive laparotomy. Conclusions: Segmented abdominopelvic free fluid volumes had greater predictive utility for decision to perform early decompressive laparotomy than previously described ACS-related CT signs in trauma patients who developed refractory abdominal compartment syndrome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors for Chronic Urinary Toxicity After the Treatment of Prostate Cancer With Adaptive Three-Dimensional Conformal Radiotherapy: Dose-Volume Analysis of a Phase II Dose-Escalation Study

Purpose: To identify factors predictive for chronic urinary toxicity secondary to high-dose adaptive three-dimensional conformal radiation. Methods and Materials: From 1999 to 2002, 331 consecutive patients with clinical Stage II-III prostate cancer were prospectively treated (median dose, 75.6 Gy). The bladder was contoured, and the bladder wall was defined as the outer 3 mm of the bladder solid volume. Toxicity was quantified according to the National Cancer Institute Common Toxicity Criteria 2.0. Median follow-up was 1.6 years. Results: The 3-year rates of Grade {>=}2 and Grade 3 chronic urinary toxicity were 17.0% and 3.6%, respectively. Prostate volume, confidence-limited patient-specific planning target volume, bladder wall volume, and acute urinary toxicity were all found to be accurate predictors for chronic urinary toxicity. The volume of bladder wall receiving {>=}30 Gy (V30) and {>=}82 Gy (V82), along with prostate volume, were all clinically useful predictors of Grade {>=}2 and Grade 3 chronic urinary toxicity and chronic urinary retention. Both Grade {>=}2 (p = 0.001) and Grade 3 (p = 0.03) acute urinary toxicity were predictive for the development of Grade {>=}2 (p = 0.001, p = 0.03) and Grade 3 (p = 0.05, p < 0.001) chronic urinary toxicity. On Cox multivariate analysis the development of acute toxicity was independently predictive for the development of both Grade {>=}2 and Grade 3 chronic urinary toxicity. Conclusions: Acute urinary toxicity and bladder wall dose-volume endpoints are strong predictors for the development of subsequent chronic urinary toxicity. Our recommendation is to attempt to limit the bladder wall V30 to <30 cm{sup 3} and the V82 to <7 cm{sup 3} when possible. If bladder wall information is not available, bladder solid V30 and V82 may be used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Five Segmentation Tools for {sup 18}F-Fluoro-Deoxy-Glucose-Positron Emission Tomography-Based Target Volume Definition in Head and Neck Cancer

Purpose: Target-volume delineation for radiation treatment to the head and neck area traditionally is based on physical examination, computed tomography (CT), and magnetic resonance imaging. Additional molecular imaging with {sup 18}F-fluoro-deoxy-glucose (FDG)-positron emission tomography (PET) may improve definition of the gross tumor volume (GTV). In this study, five methods for tumor delineation on FDG-PET are compared with CT-based delineation. Methods and Materials: Seventy-eight patients with Stages II-IV squamous cell carcinoma of the head and neck area underwent coregistered CT and FDG-PET. The primary tumor was delineated on CT, and five PET-based GTVs were obtained: visual interpretation, applying an isocontour of a standardized uptake value of 2.5, using a fixed threshold of 40% and 50% of the maximum signal intensity, and applying an adaptive threshold based on the signal-to-background ratio. Absolute GTV volumes were compared, and overlap analyses were performed. Results: The GTV method of applying an isocontour of a standardized uptake value of 2.5 failed to provide successful delineation in 45% of cases. For the other PET delineation methods, volume and shape of the GTV were influenced heavily by the choice of segmentation tool. On average, all threshold-based PET-GTVs were smaller than on CT. Nevertheless, PET frequently detected significant tumor extension outside the GTV delineated on CT (15-34% of PET volume). Conclusions: The choice of segmentation tool for target-volume definition of head and neck cancer based on FDG-PET images is not trivial because it influences both volume and shape of the resulting GTV. With adequate delineation, PET may add significantly to CT- and physical examination-based GTV definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postimplantation Analysis Enables Improvement of Dose-Volume Histograms and Reduction of Toxicity for Permanent Seed Implantation

Purpose: To demonstrate how postimplantation analysis is useful for improving permanent seed implantation and reducing toxicity. Patients and Methods: We evaluated 197 questionnaires completed by patients after permanent seed implantation (monotherapy between 1999 and 2003). For 70% of these patients, a computed tomography was available to perform postimplantation analysis. The index doses and volumes of the dose-volume histograms (DVHs) were determined and categorized with respect to the date of implantation. Differences in symptom scores relative to pretherapeutic status were analyzed with regard to follow-up times and DVH descriptors. Acute and subacute toxicities in a control group of 117 patients from an earlier study (June 1999 to September 2001) by Wust et al. (2004) were compared with a matched subgroup from this study equaling 110 patients treated between October 2001 and August 2003. Results: Improved performance, identifying a characteristic time dependency of DVH parameters (after implantation) and toxicity scores, was demonstrated. Although coverage (volume covered by 100% of the prescription dose of the prostate) increased slightly, high-dose regions decreased with the growing experience of the users. Improvement in the DVH and a reduction of toxicities were found in the patient group implanted in the later period. A decline in symptoms with follow-up time counteracts this gain of experience and must be considered. Urinary and sexual discomfort was enhanced by dose heterogeneities (e.g., dose covering 10% of the prostate volume, volume covered by 200% of prescription dose). In contrast, rectal toxicities correlated with exposed rectal volumes, especially the rectal volume covered by 100% of the prescription dose. Conclusion: The typical side effects occurring after permanent seed implantation can be reduced by improving the dose distributions. An improvement in dose distributions and a reduction of toxicities were identified with elapsed time between 1999 and 2003.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

When Is CT-Based Postoperative Seroma Most Useful to Plan Partial Breast Radiotherapy? Evaluation of Clinical Factors Affecting Seroma Volume and Clarity

Purpose: To evaluate the effect of the time from surgery and other clinical factors on seroma volume and clarity and establish the optimal time to use the computed tomography (CT)-based seroma to plan partial breast irradiation (PBI). Methods and Materials: A total of 205 women with early-stage breast cancer underwent planning CT after breast-conserving surgery. One radiation oncologist contoured the seroma volume and scored the seroma clarity, using a standardized Seroma Clarity Score scale, from 0 (not detectable) to 5 (clearest). Univariate and multivariate analyses were performed to evaluate the associations between the seroma characteristics and the interval from surgery and other clinical factors. Results: The mean interval from surgery to CT was 84 days (standard deviation 59). During postoperative Weeks 3-8, the mean seroma volume decreased from 47 to 30 cm{sup 3}, stabilized during Weeks 9-14 (mean 21) and was involuted beyond 14 weeks (mean 9 cm{sup 3}). The mean seroma clarity score was 3.4 at Weeks 3-8, 2.5 at Weeks 9-14, and 1.6 after 14 weeks. The seroma clarity was greater in patients aged {>=}70 years. The seroma volume and clarity correlated significantly with the volume of excised breast tissue but not with the maximal tumor diameter, surgical re-excision, or chemotherapy use. Conclusion: The optimal time to obtain the planning CT scan for PBI is within 8 weeks after surgery. During Weeks 9-14, the seroma might remain adequately defined in some patients; however, after 14 weeks, alternate strategies are needed to identify the PBI target. The lack of correlation between the seroma volume and tumor size suggests that the CT-based seroma should not be the sole guide for PBI target volume definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variation in the Definition of Clinical Target Volumes for Pelvic Nodal Conformal Radiation Therapy for Prostate Cancer

Purpose: We conducted a comparative study of clinical target volume (CTV) definition of pelvic lymph nodes by multiple genitourinary (GU) radiation oncologists looking at the levels of discrepancies amongst this group. Methods and Materials: Pelvic computed tomography (CT) scans from 2 men were distributed to 14 Radiation Therapy Oncology Group GU radiation oncologists with instructions to define CTVs for the iliac and presacral lymph nodes. The CT data with contours were then returned for analysis. In addition, a questionnaire was completed that described the physicians' method for target volume definition. Results: Significant variation in the definition of the iliac and presacral CTVs was seen among the physicians. The minimum, maximum, mean (SD) iliac volumes (mL) were 81.8, 876.6, 337.6 {+-} 203 for case 1 and 60.3, 627.7, 251.8 {+-} 159.3 for case 2. The volume of 100% agreement was 30.6 and 17.4 for case 1 and 2 and the volume of the union of all contours was 1,012.0 and 807.4 for case 1 and 2, respectively. The overall agreement was judged to be moderate in both cases (kappa = 0.53 (p < 0.0001) and kappa = 0.48 (p < 0.0001). There was no volume of 100% agreement for either of the two presacral volumes. These variations were confirmed in the responses to the associated questionnaire. Conclusions: Significant disagreement exists in the definition of the CTV for pelvic nodal radiation therapy among GU radiation oncology specialists. A consensus needs to be developed so as to accurately assess the merit and safety of such treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Fluorodeoxyglucose Positron Emission Tomography to Assess Tumor Volume During Radiotherapy for Non-Small-Cell Lung Cancer and Its Potential Impact on Adaptive Dose Escalation and Normal Tissue Sparing

Purpose: To quantify changes in fluorodeoxyglucose (FDG)-avid tumor volume on positron emission tomography/computed tomography (PET/CT) during the course of radiation therapy and examine its potential use in adaptive radiotherapy for tumor dose escalation or normal tissue sparing in patients with non-small-cell lung cancer (NSCLC). Methods and Materials: As part of a pilot study, patients with Stage I-III NSCLC underwent FDG-PET/CT before radiotherapy (RT) and in mid-RT (after 40-50 Gy). Gross tumor volumes were contoured on CT and PET scans obtained before and during RT. Three-dimensional conformal RT plans were generated for each patient, first using only pretreatment CT scans. Mid-RT PET volumes were then used to design boost fields. Results: Fourteen patients with FDG-avid tumors were assessed. Two patients had a complete metabolic response, and 2 patients had slightly increased FDG uptake in the adjacent lung tissue. Mid-RT PET scans were useful in the 10 remaining patients. Mean decreases in CT and PET tumor volumes were 26% (range, +15% to -75%) and 44% (range, +10% to -100%), respectively. Designing boosts based on mid-RT PET allowed for a meaningful dose escalation of 30-102 Gy (mean, 58 Gy) or a reduction in normal tissue complication probability (NTCP) of 0.4-3% (mean, 2%) in 5 of 6 patients with smaller yet residual tumor volumes. Conclusions: Tumor metabolic activity and volume can change significantly after 40-50 Gy of RT. Using mid-RT PET volumes, tumor dose can be significantly escalated or NTCP reduced. Clinical studies evaluating patient outcome after PET-based adaptive RT are ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Repeat Computed Tomography Simulation to Assess Lumpectomy Cavity Volume During Whole-Breast Irradiation

Purpose: To determine whether the lumpectomy cavity (LPC) decreases in volume during whole-breast radiotherapy (RT) and what factors influence the decrease. Patients and Methods: Forty-three women with 44 breast lesions were prospectively enrolled. Eligible patients underwent lumpectomy followed by a CT simulation (CT1) within 60 days of surgery. Patients were treated to the entire breast to a dose of 45-50.4 Gy. After 21-23 treatments, a second planning CT simulation (CT2) was done. The LPC was contoured on CT2, and the volumes (LCV) were compared between CT1 and CT2. Results: The median LCV on CT1 and CT2 was 38.2 cm{sup 3} and 21.7 cm{sup 3}, respectively. The median percent change and volume decrease between CT1 and CT2 was -32.0% and 11.2 cm{sup 3}, respectively (n = 44). The LCV decreased in 38 of 44 patients (86%). There was a significant correlation between initial LCV and decrease in volume (p = 0.001) and initial LCV and percent decrease in volume (p < 0.001). There was no correlation between time from surgery to CT1, to start of RT, or to CT2 and change in volume. Conclusions: Patients who undergo lumpectomy almost always have a decrease in their LCV during whole-breast RT. There was a correlation between the initial LCV and decrease in volume on repeat CT simulation. Evaluating patients for this change can potentially lead to decreased doses of radiation to the remaining breast and other critical structures when delivering a small-field boost. Repeat CT simulation should be considered in patients with larger cavities or cavities near critical structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the Effect of a Contouring Protocol on Postprostatectomy Radiotherapy Clinical Target Volumes and Interphysician Variation

Purpose: To compare postprostatectomy clinical target volume (CTV) delineation before and after the introduction of a contouring protocol and to investigate its effect on interphysician variability Methods and Materials: Six site-specialized radiation oncologists independently delineated a CTV on the computed tomography (CT) scans of 3 patients who had received postprostatectomy radiotherapy. At least 3 weeks later this was repeated, but with the physicians adhering to the contouring protocol from the Medical Research Council's Radiotherapy and Androgen Deprivation In Combination After Local Surgery (RADICALS) trial. The volumes obtained before and after the protocol were compared and the effect of the protocol on interphysician variability assessed. Results: An increase in mean CTV for all patients of 40.7 to 53.9cm{sup 3} was noted as a result of observing the protocol, with individual increases in the mean CTV of 65%, 15%, and 24% for Patients 1, 2, and 3 respectively. A reduction in interphysician variability was noted when the protocol was used. Conclusions: Substantial interphysician variation in target volume delineation for postprostatectomy radiotherapy exists, which can be reduced by the use of a contouring protocol. The RADICALS contouring protocol increases the target volumes when compared with those volumes typically applied at our center. The effect of treating larger volumes on the therapeutic ratio and resultant toxicity should be carefully monitored, particularly if the same dose-response as documented in radical prostate radiotherapy applies to the adjuvant and salvage setting. Prostate cancer, Postprostatectomy, Radiotherapy, Target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗