Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

NUMERICAL VERIFICATION OF THE RELAP-7 CORE CHANNEL SINGLE-PHASE MODEL

The RELAP-7 code is the next generation of nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). All the physics in RELAP-7 are fully coupled and the errors resulted from the traditional operator-splitting approach are eliminated. By using 2nd order methods in both time and space and eliminating operator-splitting errors, the numerical error of RELAP-7 can be minimized. Numerical verification is the process to verify the orders of numerical methods. It is an important part of modern verification and validation process. The core channel component in RELAP-7 is designed to simulate coolant flow as well as the conjugated heat transfer between coolant flow and the fuel rod. A special treatment at fuel centerline to avoid numerical singularity for the cylindrical heat conduction in the continuous finite element mesh is discussed. One steady state test case and one fast power up transient test case are utilized for the verification of the core channel model with single-phase flow. Analytical solution for the fuel pin temperature and figures of merit such as peak clad temperature and peak fuel temperature are used to define numerical errors. These cases prove that the mass and energy are well conserved and 2nd order convergence rates for both time and space are achieved in the core channel model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Addendum to SAND2023-09604 Xyce lumped-element transmission line model verification to support Empire-Cable cable SGEMP analyses

This report supplements the Verification of Empire-Cable SAND report by expanding on the use of Xyce to simulate the coupling to a transmission line cable model. While Empire-Cable solves its governing equations on a high-order, finite-element mesh with an an implicit-in-time formulation, Xyce must use a first order graph for the circuit and explicit-in-time approach to be compatible with non-linear electrical device models. Thus, given the different solution methodologies in Xyce as compared to Empire-Cable, the convergence rates are expected to be different but the overall quality of the solution should be the same. The original four canonical problems studied in the Empire-Cable verification report are replicated here running in Xyce using transmission line modeling parameters from the verification report. Overall, agreement between the codes is excellent with Xyce’s convergence rates being limited mostly to first order due to the circuit network approximation of a transmission line being a first order approximation.

42 ENGINEERING↗

Investigation of an implantable dosimeter for single-point water equivalent path length verification in proton therapy

Purpose: In vivo range verification in proton therapy is highly desirable. A recent study suggested that it was feasible to use point dose measurement for in vivo beam range verification in proton therapy, provided that the spread-out Bragg peak dose distribution is delivered in a different and rather unconventional manner. In this work, the authors investigate the possibility of using a commercial implantable dosimeter with wireless reading for this particular application. Methods: The traditional proton treatment technique delivers all the Bragg peaks required for a SOBP field in a single sequence, producing a constant dose plateau across the target volume. As a result, a point dose measurement anywhere in the target volume will produce the same value, thus providing no information regarding the water equivalent path length to the point of measurement. However, the same constant dose distribution can be achieved by splitting the field into a complementary pair of subfields, producing two oppositely ''sloped'' depth-dose distributions, respectively. The ratio between the two distributions can be a sensitive function of depth and measuring this ratio at a point inside the target volume can provide the water equivalent path length to the dosimeter location. Two types of field splits were used in the experiment, one achieved by the technique of beam current modulation and the other by manipulating the location and width of the beam pulse relative to the range modulator track. Eight MOSFET-based implantable dosimeters at four different depths in a water tank were used to measure the dose ratios for these field pairs. A method was developed to correct the effect of the well-known LET dependence of the MOSFET detectors on the depth-dose distributions using the columnar recombination model. The LET-corrected dose ratios were used to derive the water equivalent path lengths to the dosimeter locations to be compared to physical measurements. Results: The implantable dosimeters measured the dose ratios with a reasonable relative uncertainty of 1%-3% at all depths, except when the ratio itself becomes very small. In total, 55% of the individual measurements reproduced the water equivalent path lengths to the dosimeters within 1 mm. For three dosimeters, the difference was consistently less than 1 mm. Half of the standard deviations over the repeated measurements were equal or less than 1 mm. Conclusions: With a single fitting parameter, the LET-correction method worked remarkably well for the MOSFET detectors. The overall results were very encouraging for a potential method of in vivo beam range verification with millimeter accuracy. This is sufficient accuracy to expand range of clinical applications in which the authors could use the distal fall off of the proton depth dose for tight margins.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remaining Sites Verification Package for the 600-111, P-11 Critical Mass Laboratory Crib, and UPR-600-16, Fire and Contamination Spread Waste Sites, Waste Site Reclassification Form 2004-065

The 600-111, P-11 Critical Mass Laboratory Crib waste site, also referred to as the P-11 Facility, included the 120 Experimental Building, the 123 Control Building, and the P-11 Crib. The facility was constructed in 1949 and was used as a laboratory for plutonium criticality studies. In accordance with this evaluation, the confirmatory and verification sampling results support a reclassification of this site to Interim Closed Out. The results of confirmatory and verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quarterly Report for Dry Storage Safeguards -Q3-2018-LLNL

The objective of this study is to develop a novel methodology for verification of spent fuel inside dry storage casks by analyzing fast/epi-thermal neutrons coming from the top surface of the dry storage casks. In FY2018, data required for MCNP modeling will be gathered, prepared and used to perform MCNP simulations of the system to validate the effectiveness of the verification methodology. Once the methodology is demonstrated to be effective and valid, parameters that affect the detector system sensitivity will be studied as well as the study of diversion scenarios and partial detect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of an in-vivo proton beam range check method in an anthropomorphic pelvic phantom using dose measurements

Purpose: In-vivo dosimetry and beam range verification in proton therapy could play significant role in proton treatment validation and improvements. In-vivo beam range verification, in particular, could enable new treatment techniques one of which could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. This paper reports validation study of an in-vivo range verification method which can reduce the range uncertainty to submillimeter levels and potentially allow for in-vivo dosimetry. Methods: An anthropomorphic pelvic phantom is used to validate the clinical potential of the time-resolved dose method for range verification in the case of prostrate treatment using range modulated anterior proton beams. The method uses a 3 × 4 matrix of 1 mm diodes mounted in water balloon which are read by an ADC system at 100 kHz. The method is first validated against beam range measurements by dose extinction measurements. The validation is first completed in water phantom and then in pelvic phantom for both open field and treatment field configurations. Later, the beam range results are compared with the water equivalent path length (WEPL) values computed from the treatment planning system XIO. Results: Beam range measurements from both time-resolved dose method and the dose extinction method agree with submillimeter precision in water phantom. For the pelvic phantom, when discarding two of the diodes that show sign of significant range mixing, the two methods agree with ±1 mm. Only a dose of 7 mGy is sufficient to achieve this result. The comparison to the computed WEPL by the treatment planning system (XIO) shows that XIO underestimates the protons beam range. Quantifying the exact XIO range underestimation depends on the strategy used to evaluate the WEPL results. To our best evaluation, XIO underestimates the treatment beam range between a minimum of 1.7% and maximum of 4.1%. Conclusions: Time-resolved dose measurement method satisfies the two basic requirements, WEPL accuracy and minimum dose, necessary for clinical use, thus, its potential for in-vivo protons range verification. Further development is needed, namely, devising a workflow that takes into account the limits imposed by proton range mixing and the susceptibility of the comparison of measured and expected WEPLs to errors on the detector positions. The methods may also be used for in-vivo dosimetry and could benefit various proton therapy treatments.

60 APPLIED LIFE SCIENCES↗

An Optimized Online Verification Imaging Procedure for External Beam Partial Breast Irradiation

The purpose of this study was to evaluate the capabilities of a kilovoltage (kV) on-board imager (OBI)-equipped linear accelerator in the setting of on-line verification imaging for external-beam partial breast irradiation. Available imaging techniques were optimized and assessed for image quality using a modified anthropomorphic phantom. Imaging dose was also assessed. Imaging techniques were assessed for physical clearance between patient and treatment machine using a volunteer. Nonorthogonal kV image pairs were identified as optimal in terms of image quality, clearance, and dose. After institutional review board approval, this approach was used for 17 patients receiving accelerated partial breast irradiation. Imaging was performed before every fraction verification with online correction of setup deviations >5 mm (total image sessions = 170). Treatment staff rated risk of collision and visibility of tumor bed surgical clips where present. Image session duration and detected setup deviations were recorded. For all cases, both image projections (n = 34) had low collision risk. Surgical clips were rated as well as visualized in all cases where they were present (n = 5). The average imaging session time was 6 min, 16 sec, and a reduction in duration was observed as staff became familiar with the technique. Setup deviations of up to 1.3 cm were detected before treatment and subsequently confirmed offline. Nonorthogonal kV image pairs allowed effective and efficient online verification for partial breast irradiation. It has yet to be tested in a multicenter study to determine whether it is dependent on skilled treatment staff.

61 RADIATION PROTECTION AND DOSIMETRY↗

High-Temperature Gas-Cooled Reactors Multiphysics Simulation Demonstration and Code Validation

This study presents a comprehensive benchmarking and verification effort of several thermal-hydraulic and multiphysics capabilities for high-temperature gas-cooled reactor applications. The first part of this effort focuses on the running-in verification of Griffin’s multiphysics capabilities, specifically for simulating the evolution of pebble-bed reactor cores from startup to equilibrium. Since Fiscal Year 2024, improvements and enhancements have been implemented in Griffin, including simplifying the process to specify streamlines and developing the online cross-section generation capability. In the absence of validation data, code-to-code comparisons are conducted with kugelpy, showing good agreement for integral quantities like k-eff predictions and predictions for maximum power density. However, accuracy issues are noted for more detailed quantities like the spatial distribution of fission rate densities which will require further work to address. The second part of this report presents an improved System Analysis Module (SAM) core channel model where the effects of cross flow are considered during the pressurized loss of forced cooling transient, resulting in an improved agreement of the predicted pebble temperature with respect to the predictions from the SAM 2D porous media model. Additionally, the wall channeling effect due to variable porosity at the near wall region of the core is also investigated. Furthermore, to demonstrate Griffin’s online cross-section generation capability, a Multiphysics simulation is performed by coupling Griffin to the SAM core channel model. In the third part of the report, as a part of the Organisation for Economic Co-operation and Development/Nuclear Energy Agency (OECD/NEA) thermal-hydraulic code validation benchmark activity for a high-temperature gas-cooled reactor, the High Temperature Test Facility (HTTF) is investigated first using the NekRS computational fluid dynamics (CFD) code to study the flow mixing phenomenon in the lower plenum of the facility. Then, code-to-code and code-to-data comparisons are performed for Test PG27, which is a pressurized conduction cooldown (PCC) test, using five different codes by six organizations from five countries. The different simulations show good agreements in terms of the general trend but there are differences in some results such as the peak temperatures of different regions and heat removal rate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY2021 Improvements to the New CTH Code Verification & Validation Test Suite

Over the past few years, the CTH multiphysics hydrocode has overhauled its software quality and testing processes, implementing current best practices in software quality and building a robust V&V test suite comprised of traditional hydrocode verification problems, including ASC Tri-Lab Test Suite and Enhanced Tri-Lab Test Suite problems, as well as validation problems for some of CTH’s most frequently used equations of state, materials models, and other key capabilities. Substantial progress towards building this new test suite was made in FY19 and FY20. In FY21, the test suite has been expanded to include verification and validation tests of the Steinberg-Guinan-Lund (ST) viscoplastic model and the Johnson Cook (JFRAC) fracture model. Additionally, two new verification tests were added, covering hydrodynamics and high explosive (HE) modeling capabilities: the Kidder Gaussian density problem and the Escape of HE Products (EHEP) problem from the Tri-Lab Test Suite. This report discusses each of these test problems in detail. Verification test results are compared to analytic solutions. Validation test results are compared to experimental data. Wherever possible, convergence or mesh refinement studies are included. Additionally, while implementing the Kidder verification problem, a bug was identified that affects the use of tables to initialize pressure or density in 1D or 2D calculations. A brief discussion of the bug and its fix is included. CTH demonstrates good performance overall on the new test suite problems. Simulation results showed good agreement with analytic solutions for the Kidder problem, with convergence rates ranging between 1.8 and sub-linear, and relatively good agreement for the EHEP problem, though convergence rates for pressure and density were nearly 0. The ST and JFRAC strain rate loading verification tests show good agreement with analytic solutions. Likewise, CTH simulation results show good agreement with experimental validation data, including Taylor rod impact testing, for the materials tested. Future V&V work will focus on adding 2D and 3D versions of existing verification tests as well as adding validation tests of other frequently used capabilities such as other fracture models.

42 ENGINEERING↗

Verification of the sensitivity and uncertainty-based criticality safety validation techniques: ORNL’s SCALE case study

The use of sensitivity and uncertainty-based techniques has been well-developed in the neutronic community for criticality safety applications. Sensitivity techniques calculate the first-order relative variations in keff due to relative cross-section variations by isotope, reaction type, and incident neutron energy. The result is a vector of sensitivity coefficients which is folded with prior cross-section uncertainties to calculate the so-called similarity indices. Similarity indices are integral quantities which serve as useful mathematical measures for assessing the relevance of existing or new experiments to given application conditions, representing design systems for which the models are to be validated. Despite their importance for a wide range of validation activities, the peer-reviewed literature is non-existent on the development of rigorous verification analysis for their calculated values. Thus, this manuscript proposes a simple non-intrusive method to calculate similarity indices, serving as an independent verification tool for their evaluation. The manuscript derives the theoretical basis for the proposed verification analysis. Next, the verification analysis is applied to the ORNL’s SCALE code suite which employs adjoint-based methods to calculate similarity indices. Numerical experiments using a number of well-known benchmark experiments are employed to verify the calculation of the similarity indices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Code-verification techniques for hypersonic reacting flows in thermochemical nonequilibrium

The study of hypersonic flows and their underlying aerothermochemical reactions is particularly important in the design and analysis of vehicles exiting and reentering Earth's atmosphere. Computational physics codes can be employed to simulate these phenomena; however, code verification of these codes is necessary to certify their credibility. To date, few approaches have been presented for verifying codes that simulate hypersonic flows, especially flows reacting in thermochemical nonequilibrium. In this work, we present our code-verification techniques for verifying the spatial accuracy and thermochemical source term in hypersonic reacting flows in thermochemical nonequilibrium. Additionally, we demonstrate the effectiveness of these techniques on the Sandia Parallel Aerodynamics and Reentry Code (SPARC).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A limited-angle intrafraction verification (LIVE) system for radiation therapy

Purpose: Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study aims to develop a limited-angle intrafraction verification (LIVE) system to use prior information, deformation models, and limited angle kV-MV projections to verify target position intrafractionally. Methods: The LIVE system acquires limited-angle kV projections simultaneously during arc treatment delivery or in-between static 3D/IMRT treatment beams as the gantry moves from one beam to the next. Orthogonal limited-angle MV projections are acquired from the beam's eye view (BEV) exit fluence of arc treatment beam or in-between static beams to provide additional anatomical information. MV projections are converted to kV projections using a linear conversion function. Patient prior planning CT at one phase is used as the prior information, and the on-board patient volume is considered as a deformation of the prior images. The deformation field is solved using the data fidelity constraint, a breathing motion model extracted from the planning 4D-CT based on principal component analysis (PCA) and a free-form deformation (FD) model. LIVE was evaluated using a 4D digital extended cardiac torso phantom (XCAT) and a CIRS 008A dynamic thoracic phantom. In the XCAT study, patient breathing pattern and tumor size changes were simulated from CT to treatment position. In the CIRS phantom study, the artificial target in the lung region experienced both size change and position shift from CT to treatment position. Varian Truebeam research mode was used to acquire kV and MV projections simultaneously during the delivery of a dynamic conformal arc plan. The reconstruction accuracy was evaluated by calculating the 3D volume percentage difference (VPD) and the center of mass (COM) difference of the tumor in the true on-board images and reconstructed images. Results: In both simulation and phantom studies, LIVE achieved substantially better reconstruction accuracy than reconstruction using PCA or FD deformation model alone. In the XCAT study, the average VPD and COM differences among different patient scenarios for LIVE system using orthogonal 30° scan angles were 4.3% and 0.3 mm when using kV+BEV MV. Reducing scan angle to 15° increased the average VPD and COM differences to 15.1% and 1.7 mm. In the CIRS phantom study, the VPD and COM differences for the LIVE system using orthogonal 30° scan angles were 6.4% and 1.4 mm. Reducing scan angle to 15° increased the VPD and COM differences to 51.9% and 3.8 mm. Conclusions: The LIVE system has the potential to substantially improve intrafraction target localization accuracy by providing volumetric verification of tumor position simultaneously during arc treatment delivery or in-between static treatment beams. With this improvement, LIVE opens up a new avenue for margin reduction and dose escalation in both fractionated treatments and SRS and SBRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmark for two-dimensional large scale coherent structures in partially magnetized E × B plasmas—community collaboration & lessons learned

Low-temperature plasmas (LTPs) are essential to both fundamental scientific research and critical industrial applications. As in many areas of science, numerical simulations have become a vital tool for uncovering new physical phenomena and guiding technological development. Code benchmarking remains crucial for verifying implementations and evaluating performance. This work continues the Landmark benchmark initiative, a series specifically designed to support the verification of LTP codes. In this study, seventeen simulation codes from a collaborative community of nineteen international institutions modeled a partially magnetized E × B Penning discharge. The emergence of large scale coherent structures, or rotating plasma spokes, endows this configuration with an enormous range of time scales, making it particularly challenging to simulate. The codes showed excellent agreement on the rotation frequency of the spoke as well as key plasma properties, including time-averaged ion density, plasma potential, and electron temperature profiles. Achieving this level of agreement came with challenges, and we share lessons learned on how to conduct future benchmarking campaigns. Comparing code implementations, computational hardware, and simulation runtimes also revealed interesting trends, which are summarized with the aim of guiding future plasma simulation software development.

benchmarking↗

The Influence of Sulfur Content on the Carbothermal Reduction of SiMn Slag

This article examines the influence of sulfur content on the carbothermal reduction of MnO and SiO{sub 2} in SiMn slag by carbon black. The sulfur content in the synthetic slag is varied from 0 to 1.0 wt pct. Reduction experiments are carried out in a thermogravimetric (TG) furnace at 1873 K (1600 °C) under CO atmospheric pressure. The reduction rates are measured based on the weight loss data, and the samples are characterized by SEM/EDS and ICP-MS. The wetting property of slag on carbon black is also studied with the sessile drop technique. The reaction rate on the slag-metal interface is one order higher than on the slag-carbon interface. A small amount of sulfur (0.2 and 0.44 wt pct) accelerates the slag-metal reaction rate constant by 2.2 and 4.2 times, respectively. Therefore, small amounts of sulfur in slag significantly improve the reduction of MnO and SiO{sub 2}. The MnS precipitation phenomenon during slag cooling is studied by FactSage simulation and experimental verification.

36 MATERIALS SCIENCE↗

RF pulse shape control in the compact linear collider test facility

The Compact Linear Collider (CLIC) is a study for an electron–positron machine aiming at accelerating and colliding particles at the next energy frontier. The CLIC concept is based on the novel two-beam acceleration scheme, where a high-current low-energy drive beam generates RF in series of power extraction and transfer structures accelerating the low-current main beam. To compensate for the transient beam-loading and meet the energy spread specification requirements for the main linac, the RF pulse shape must be carefully optimized. This was recently modelled by varying the drive beam phase switch times in the sub-harmonic buncher so that, when combined, the drive beam modulation translates into the required voltage modulation of the accelerating pulse. In this paper, the control over the RF pulse shape with the phase switches, that is crucial for the success of the developed compensation model, is studied. The results on the experimental verification of this control method are presented and a good agreement with the numerical predictions is demonstrated. Implications for the CLIC beam-loading compensation model are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental and modeling study on char combustion

In this study, on the basis of experimental verifications with an FTIR online measurement system, theoretical calculations by using the strict continuous-film model were first compared with those by the simple single-film model that is still widely used in mathematical modeling of pulverized coal flames. The results indicated that the single-film model has some significant errors in its predictions of the ignition temperature and the combustion following ignition and hence should have some restrictions on its application. Then an improved char combustion model has been presented, taking into consideration the influence of the finite-rate heterogeneous reduction and oxidation reactions. This model gives the explicit algebraic expressions for the overall rate of combustion, the surface temperature of the particle, and the gas temperature at the flame sheet. Compared with the single-film model, predictions by the present model were in much better agreement with those predicted by the continuous-film model and the experimental data. The novel model is also much easier to be integrated into the comprehensive computing codes for industrial pulverized coal flame than the continuous-film model. 21 refs., 14 figs.

01 COAL, LIGNITE, AND PEAT↗

Challenges and Possible Solutions in Aeroelastic Modeling for the Distributed Wind Industry

Aeroelastic modeling (AM) is the primary methodology for structural and performance assessment of any wind turbine; it provides an understanding of the impact of design parameters on turbine loading and power response before witnessing it in the field. Despite these advantages, the use of AM in the distributed wind technology (DWT) sector is limited. This article represents a short summary of an in-depth assessment by the authors of the status of AM and its role within the distributed wind technology design standards. The research gathered input and feedback from a large number of U.S. and international stakeholders, reviewed technical strengths and weaknesses of the current edition of the design standards, analyzed the minutes from recent industry workshops and meetings, collected publicly available AM templates, and provided an evaluation of the existing AM codes. Several goals were achieved including providing strategies for the load assessment categorization of turbines based on rotor swept area and archetype, and guidance for AM verification and validation. Recommendations within this study will advance the value and the ease-of-use of AM, thereby allowing the industry to better capitalize this underutilized tool, resulting in a more efficient design process, an easier path to certification, and overall better and more reliable distributed wind technology products.

17 WIND ENERGY↗

SU-E-T-260: Development of a System to Verify for Connection Consistency in a Brachytherapy

Purpose: Brachytherapy has multiple manual procedures which are prone to human error, especially during the connection process of the treatment device to applicator. This is when considerable attention is required. In this study, we propose a new connection verification device concept. Methods: The system is composed of a ring magnet (anisotropic ferrite : magfine Inc), hole device (A1324LUA-T : Allegro MicroSystems Phil Inc) and an in-house check cable, which is made from magnetic material (Figure1). The magnetic field distribution is affected by the check cable position and any magnetic field variation is detected by the hole device. This system frequency is 20Hz and the average of 4 signals was used as hole device value to reduce noise. Results: The value of the hole device is altered, depending on the location of the check cable. The resolution of the check cable position is 5mm and 10mm, around a 10mm region from the hole device and over 10mm, respectively. There was a reduction in sensitivity of the hole device, in our test, which was linked to the distance of the hole device from the check cable. Conclusion: We demonstrated a new concept of connection verification in a brachytherapy. This system has the possibility to detect an incorrect connection. Moreover, the system is capable of self-optimization, such as determining the number of hole device and the magnet strength.Acknowledgement:This work was supported by JSPS Core -to-Core program Number 23003 and KAKENHI Grant Number 26860401. This work was supported by JSPS Core-to-Core program Number 23003 and KAKENHI Grant Number 26860401.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗