Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery energy storage system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Principles and Options for Designing Battery Energy Storage Zoning Ordinances

Deployment of battery energy storage (BESS) systems, both standalone and as part of hybrid systems paired with generation, has rapidly increased in the United States in recent years as utilities and communities have deployed storage to improve electric grid reliability and act as a cost-effective alternative to larger grid infrastructure. The modular nature of BESS technologies means systems may be built near other existing land uses, creating the potential for conflicts with neighboring landowners that can be managed and mitigated through zoning and permitting requirements established by local jurisdictions. While many cities and counties have adopted ordinances specific to BESS into their local zoning codes, these ordinances vary significantly in their requirements and level of detail. Meanwhile, many other jurisdictions, including those home to proposed or existing BESS projects, lack any specific language related to BESS in their zoning codes. Local planning and zoning officials have limited capacity and may lack the familiarity with BESS technologies needed to develop ordinances or otherwise make reasonable zoning decisions that balance safety, community impacts, and other goals. The resulting uncertainty at the local zoning level has led developers to withdraw projects in some areas and has spurred moratoria or bans on energy storage projects in others. This report intends to provide practical resources for practitioners interested in reasonable and effective local regulation of battery energy storage. It does not present a model zoning ordinance, but rather is intended to complement model ordinances developed by others by providing additional context and analysis regarding the structure of energy storage zoning ordinances and the decision points for local officials. Zoning ordinances at the city, town, and county level across the U.S. were surveyed alongside two template model ordinances to identify common elements and options for regulating the zoning and siting of BESS. Common elements identified and analyzed include definitions and general requirements, including cutoffs or tiers used to apply regulations to different system sizes and the permitted zones where jurisdictions allow BESS to be sited; visual, noise, and aesthetic requirements, including property line setbacks, fencing and visual screening, noise, and lighting requirements; and safety and planning requirements, such as site plans, decommissioning plans or funds, and requirements for access by emergency services. The report also summarizes some of the more unique regulations, including those that place additional restrictions on BESS at the local level.

25 ENERGY STORAGE↗

Hydropower Advantages over Batteries in Energy Storage of Off-Grid Systems: A Case Study

Microgrids are decentralized power production systems, where the energy production and consumption are very close to each other. Microgrids generally exploit renewable energy sources, encountering a problem of storage, as the power production from solar and wind is intermittent. This research presents a new integrated methodology and discusses a comparison of batteries and pumped storage hydropower (PSH) as energy storage systems with the integration of wind and solar PV energy sources, which are the major upcoming technologies in the renewable energy sector. We implemented the simulator and optimizer model (HOMER), which develops energy availability usage to obtain optimized renewable energy integration in the microgrid, showing its economic added value. Two scenarios are run with this model—one considers batteries as an energy storage technology and the other considers PSH—in order to obtain the best economic and technical results for the analyzed microgrid. The economic analysis showed a lower net present cost (NPC) and levelized cost of energy (LCOE) for the microgrid with PSH. The results showed that the microgrid with the storage of PSH was economical, with an NPC of 45.8 M€ and an LCOE of 0.379 €/kWh, in comparison with the scenario with batteries, which had an NPC of 95.2 M€ and an LCOE of 0.786 €/kWh. The role of storage was understood by differentiating the data into different seasons, using a Python model. Furthermore, a sensitivity analysis was conducted by varying the capital cost multiplier of solar PV and wind turbines to obtain the best optimal economic solutions.

Guruprasad, Prajwal↗

Optimal Strategies for Hybrid Battery‐Storage Systems Design

As stationary hybrid energy‐storage systems (HESS) for power systems applications have recently drawn interest due to their enhanced performance and decreasing cost, developing systematic approaches for HESS design while considering controls is gaining traction. Herein, a method is presented to optimally design hybrid battery storage by proposing a mathematical modeling framework, formulated as a mixed integer linear programming model. The optimization is capable of handling multiple subsystems of batteries, considering their economic and technological performance. Decisions involve sizing of the batteries, optimal temporal and strategic dispatch to end uses, and energy sources for charging each battery. The applicability of the model is tested on four case studies for three battery chemistries representing distinct objectives: high‐power, high‐energy, and second life. Compared to traditionally designed battery storage with a homogeneous battery, optimally designed hybrid systems can save 12%–26% of system costs, depending on the nature of the dispatch profile. Findings point to design preference toward the second life battery supplemented with some high‐power or high‐energy battery capacity, or both. With the utilized electricity price structure, customers can experience approximately 10%–35% reduction in their bills.

Koleva, Mariya↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

Battery Storage Unlocked: Lessons Learned From Emerging Economies

The Clean Energy Ministerial (CEM) is a global forum that promotes policies and programs that advance clean energy technology. The CEM's mission is to bring together a community of global leaders to scale clean energy, amplifying the impact to all the sectors of the economy and applying a whole-of-society approach to meet collective climate and clean energy goals. At COP28 in Dubai, United Arab Emirates, the CEM announced the Supercharging Battery Storage Initiative as a vehicle to accelerate battery storage deployment around the world. The initiative supports countries around the world in co-creating strategies that enhance policy, regulation, supply chain, manufacturing, and financing solutions for battery energy storage deployment. Additionally, the initiative seeks to reduce the cost of the technology and promote diversified, sustainable, and secure supply chains (CEM n.d.). Through international collaboration, the initiative supports the integration of renewable energy globally, while securing the stability and reliability of the electricity grid.

batteries↗

Thermal control system for Space Station Freedom photovoltaic power module

The electric power for Space Station Freedom (SSF) is generated by the solar arrays of the photovoltaic power modules (PVM's) and conditioned, controlled, and distributed by a power management and distribution system. The PVM's are located outboard of the alpha gimbals of SSF. A single-phase thermal control system is being developed to provide thermal control of PVM electrical equipment and energy storage batteries. This system uses ammonia as the coolant and a direct-flow deployable radiator. This paper presents the description and development status of the PVM thermal control system.

Hacha, Thomas H.↗

Thermal control system for Space Station Freedom photovoltaic power module

The electric power for Space Station Freedom (SSF) is generated by the solar arrays of the photovoltaic power modules (PVM's) and conditioned, controlled, and distributed by a power management and distribution system. The PVM's are located outboard of the alpha gimbals of SSF. A single-phase thermal control system is being developed to provide thermal control of PVM electrical equipment and energy storage batteries. This system uses ammonia as the coolant and a direct-flow deployable radiator. The description and development status of the PVM thermal control system is presented.

Hacha, Thomas H.↗

Sabathani Community Center Solar + Battery Resilience Hub

To meet south Minneapolis, Minnesota's clean energy goals, the community exploring opportunities to transition Sabathani Community Center into a resilience hub to provide critical community services during power outages, including shelter and warmth or cooling, continued food distribution services, and more. The National Renewable Energy Laboratory, through the U.S. Department of Energy's Communities LEAP (Local Energy Action Program) pilot, worked with Sabathani to quantify the costs and benefits of installing stand-alone solar photovoltaics (PV) and PV paired with battery systems to reduce energy costs, avoid emissions, and improve resilience.

battery energy storage system↗

Assessment of Energy Technology Options for the Island of Molokai, Hawaii: Analysis of Floating Solar, Pumped Storage Hydropower, and Backup Energy Systems

This report documents analysis done by researchers at the National Laboratory of the Rockies and Pacific Northwest National Laboratory to evaluate the potential for and explore project concepts of electricity generation and storage additions on the island of Molokai, Hawaii, as identified in the Community Energy Resilience Action Plan (CERAP) by the Molokai Clean Energy Hui (MCEH), Sustainable Molokai, and the Hawaii Natural Energy Institute (HNEI). These electricity generation and storage additions include distributed photovoltaics (PV), battery energy storage, and generators for critical facilities on the island that can provide backup energy to the facilities during grid disruptions and outages, a floating PV (FPV) system on Kualapuu Reservoir, and pumped storage hydropower (PSH) systems scaled to act as a significant or primary source of energy storage on the Molokai grid.

13 HYDRO ENERGY↗

Assessment of Energy Technology Options for the Island of Molokai, Hawaii: Analysis of Floating Solar, Pumped Storage Hydropower, and Backup Energy Systems [Slides]

This presentation summarizes analysis done by researchers at the National Laboratory of the Rockies and Pacific Northwest National Laboratory to evaluate the potential for and explore project concepts of electricity generation and storage additions on the island of Molokai, Hawaii, as identified in the Community Energy Resilience Action Plan (CERAP) by the Molokai Clean Energy Hui (MCEH), Sustainable Molokai, and the Hawaii Natural Energy Institute (HNEI). These electricity generation and storage additions include distributed photovoltaics (PV), battery energy storage, and generators for critical facilities on the island that can provide backup energy to the facilities during grid disruptions and outages, a floating PV (FPV) system on Kualapuu Reservoir, and pumped storage hydropower (PSH) systems scaled to act as a significant or primary source of energy storage on the Molokai grid. This presentation accompanies the full technical report published under the same title.

14 SOLAR ENERGY↗

Electric Vehicle Lithium-Ion Battery Life Cycle Management

There is no question that electric vehicles (EVs), which are key for addressing climate change impacts from the transportation sector, are quickly gaining popularity and availability. With limits and other challenges related to the supply of critical battery minerals, maximizing the use of EV batteries and ensuring recovery of battery minerals is imperative. Therefore, proper end-of-life-cycle management (reuse and recycling) of these batteries must be part of the EV ecosystem from the perspective of both the supply chain and environmental footprint. Second use of batteries for energy storage systems extends the initial life of these resources and provides a buffer until economical material recovery facilities are in place. Although there are multiple pathways to recycling and recovery of materials, new recovery technologies are moving toward commercially available hydrometallurgy and promising direct recycling, which analysis has shown has the lowest overall carbon footprint. Strategically locating these plants close to battery collection further reduces transportation and thus recycling and recovering costs. Proper life cycle management could alleviate future lithium-ion battery materials supply chains for EVs. Governments and other stakeholders around the world have started initiatives and proposed regulations to address the challenges associated with life cycle management of EV lithium batteries. Finally, as manufacturers are increasingly faced with the likelihood of such extensive regulatory requirements, attention should be given to new designs, sales, and service models that can reduce life cycle management costs.

25 ENERGY STORAGE↗

An Anode-Free Zn–MnO 2 Battery

Aqueous Zn-based batteries are attractive because of the low cost and high theoretical capacity of the Zn metal anode. However, the Zn-based batteries developed so far utilize an excess amount of Zn (i.e., thick Zn metal anode), which decreases the energy density of the whole battery. In this study, we demonstrate an anode-free design (i.e., zero-excess Zn), which is enabled by employing a nanocarbon nucleation layer. Electrochemical studies show that this design allows for uniform Zn electrodeposition with high efficiency and stability over a range of current densities and plating capacities. Using this anode-free configuration, we showcase a Zn–MnO 2 battery prototype, showing 68.2% capacity retention after 80 cycles. Our anode-free design opens a new direction for implementing aqueous Zn-based batteries in energy storage systems.

25 ENERGY STORAGE↗

Assessment of the potential of solar thermal small power systems in small utilities

The potential economic benefit of small solar thermal electric power systems to small municipal and rural electric utilities is assessed. Five different solar thermal small power system configurations were considered in three different solar thermal technologies. The configurations included: (1) 1 MW, 2 MW, and 10 MW parabolic dish concentrators with a 15 kW heat engine mounted at the focal point of each dish, these systems utilized advanced battery energy storage; (2) a 10 MW system with variable slat concentrators and central steam Rankine energy conversion, this system utilized sensible thermal energy storage; and (3) a 50 MW central receiver system consisting of a field of heliostats concentrating energy on a tower-mounted receiver and a central steam Rankine conversion system, this system also utilized sensible thermal storage. The results are summarized in terms of break-even capital costs. The break-even capital cost was defined as the solar thermal plant capital cost which would have to be achieved in order for the solar thermal plants to penetrate 10 percent of the reference small utility generation mix by the year 2000. The calculated break-even capital costs are presented.

Steitz, P.↗

Antigua and Barbuda Distributed Energy Resources Deployment Guidelines

This document is designed to provide comprehensive considerations, best practices and guidance for deployment of Distributed Energy Resources (DERs) in Antigua and Barbuda. The document provides lists of various technology selection guidance including technical specifications, requirements and applicable key standards and code associated with key DERs and balance of plant equipment. The document also presents the key microgrid design considerations to integrate the DERs to achieve the economic, decarbonization and resiliency goals. Taking into account sensitive grid for such islands, for grid readiness and screening the potential DER interconnection, general approach is highlighted along with the potential technical interconnection requirements. Furthermore, this document shows the key stakeholders involved in such DER integration and/or microgrid project and how key responsible project team can be qualified. Finally, this document refers to key information about warranties and consumer rights and maintenance of the systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligent Hierarchical Resilient Operation of Distribution Systems: Implementation and Validation in a Power Hardware-in-the-Loop Simulation Testbed

This paper reports on the structure of a power hardware-in-the-loop (PHIL) simulation testbed that implements, tests, and validates a novel AI-based hierarchical resilient operation model for distribution systems. The testbed implements the central and distributed controllers of the hierarchical resilient operation model and integrates a Digital Real-Time Simulator (DRTS), protective relays, a Real-Time Automation Controller (RTAC), a Software Defined Network (SDN) switch, and a battery energy storage (BES) system. The testbed provides comprehensive real-time visualization and monitoring capability as an advanced situational awareness and operator interface solution. The IEEE 33-node system is used as a test case to test and validate the operation of the model in normal operation and recovery operation after major outages in a fully automated fashion.

Ganjkhani, Mehdi↗

Rapid Electrochemical Diagnosis of Battery Health and Safety from Cells to Modules

Rapid electrochemical diagnosis of battery health and failure is critical for ensuring reliable battery performance and battery safety. Traditional battery health diagnostics such as capacity measurements and DC pulse tests are reliable and well-understood, however, these measurements of battery capacity and resistance do not capture all aspects of battery degradation. Other aspects of degradation, such as electrolyte decomposition, lithium-plating, and particle cracking are difficult to detect electrochemically but are crucial to measure to get a full picture of battery safety and flag out potential failures. In this work, lab- and field-aged commercial lithium-ion batteries and modules of various chemistries and formats are tested using a variety of traditional electrochemical characterization methods as well as using 2-minute pseudo-random DC pulse sequences at rest and during charge/discharge. The electrochemical measurements are compared to physical cell measurements, cell efficiency, drive cycle performance, physical and thermal heterogeneity, and qualitative safety metrics using statistical and machine-learning methods to discover if a comprehensive "battery health map" can be accurately identified using only rapid DC measurements.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Corral Summit Pumped Storage Hydropower Hybrid: Site Suitability Assessment

In 2024, Idaho National Laboratory (INL) and Pacific Northwest National Laboratory (PNNL) initiated a technical-assistance project to support Cat Creek Energy, LLC, (CCE) in evaluating site suitability for the proposed Corral Summit Pumped Storage Hydropower (PSH) project in south-central Idaho near Mackay Reservoir. The Corral Summit facility incorporates battery storage and photovoltaic (PV) solar arrays in a Trybrid configuration to deliver large-volume long-duration (LVLD) storage solutions for rural electric cooperatives in eastern Idaho. The evaluation process focused on determining the most-suitable location for the upper reservoir of the PSH system, guided by a comprehensive assessment framework spanning multiple categories, including physical characteristics, environmental constraints, building infrastructure, regulatory constraints, cultural resources and sensitivity, social factors, and power market and grid integration. Each site was analyzed based on a ranking scale (0–1), which scores ranging from “severely disfavored” to “highly favored,” allowing detailed comparisons of site-specific conditions. Categories such as hydraulic head, utilities corridor, land ownership, and transmission-grid limitations emerged as key contributors to the overall assessment. Site 2 (Idaho Trust) demonstrated a slight advantage over Site 1 (Bureau of Land Management) primarily due to favorable outcomes in regulatory constraints, building infrastructure, and power-market integration. However, Site 1 outperformed Site 2 in factors related to physical characteristics and social factors. The report emphasizes the need for further evaluation of both sites before clear determination of which site is preferred, due to the limited information available on either site at the time of this report. Key areas of evaluation to clearly define the preferred site are ecological impacts, cultural-resource surveys, and economic-feasibility assessments. For successful project execution, recommended follow-up actions include seismic and geotechnical surveys, groundwater and habitat monitoring, regulatory reviews of water rights and right-of-way agreements, cultural engagement with local tribal governments, and enhanced stakeholder strategies. These efforts will ensure the Corral Summit Trybrid facility meets local energy needs while balancing environmental, social, and regulatory responsibilities.

13 - HYDRO ENERGY↗