At least 325 records · Page 18

Introduction to Grid Forming Inverters: A Key to Transforming our Power Grid [Slides]

A grid-forming (GFM) inverter-based resource (IBR) controls maintain an internal voltage phasor that is constant or nearly constant in the sub-transient to transient time frame. This definition means that the GFM IBR will nearly immediately respond to changes in the external system and attempt to maintain IBR control during challenging network conditions to maintain grid stability. In GFM IBR, the voltage phasor is controlled to maintain synchronism with other devices in the grid while regulating the active and reactive power appropriately to support the grid. This contrasts with conventional GFL IBR controls wherein immediately after a disturbance (0-5 cycles), within the normal operating range of voltage, the output current phasor magnitude and angle remain unchanged, and the current phasor begins changing only within the transient time frame (tens of cycles) to strictly control the active and reactive power being injected into the network. This presentation gives an introduction to GFM IBR and presents the current state of the art in this area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Human Factors Design for Particle Accelerator Control Room Interfaces

Fermilab, the birthplace of many scientific discoveries in physics and particle accelerator sciences, is in the midst of a widescale modernization effort. The Accelerator Control Operations Research Network (ACORN project’s goal is to modernize the accelerator control system by replacing end-of-life power supplies and enhance future operations of the Fermilab accelerator complex with megawatt particle beams. Within ACORN, opportunities for process improvement concerning software development, human-system interface design, and task performance are also being considered. Human factors researchers from Idaho National Laboratory in collaboration with usability experts from Fermilab, are currently investigating human-centered design improvements for the accelerator control system. For example, substantial tribal knowledge and memory recall are required to effectively operate the accelerator system. This contributes to high cognitive workload and potential burnout of accelerator operators. Developing guidance for consistent visual and functional design enables a more intuitive interaction and relieves operators of cognitive burden. Additionally, developing more intuitive and integrated interfaces can also lead to improved accelerator efficacy by empowering operators with greater understanding and control of the systems. The challenge in developing such interfaces is in designing for a wide variety of user goals, system specifications, and level of experience in users. The challenges need to be met while e also considering the maintainability of the control system. The purpose of this paper is to detail the human factors process and design within the ACORN project, describe results gathered thus far, and discuss the larger implications for this work.

43 PARTICLE ACCELERATORS↗

Robust Decentralized Secondary Control Scheme for Inverter-based Power Networks

Inverter-dominated microgrids are quickly becoming a key building block of future power systems. They rely on centralized controllers that can provide reliability and resiliency in extreme events. Nonetheless, communication failures due to cyber-physical attacks or natural disasters can make autonomous operation of islanded microgrids challenging. This paper examines a unified decentralized secondary control scheme that is robust to inverter clock synchronization errors and can be seamlessly applied to grid-following or grid-forming control architectures. The proposed scheme overcomes the well-known stability problem that arises from parallel operation of local integral controllers. Theoretical guarantees for stability are provided along with criteria to appropriately tune the secondary control gains to achieve good frequency regulation performance while ensuring fair power sharing. The efficacy of our approach is demonstrated through simulations on a 5-bus microgrid with four grid-forming inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Galerkin Neural Networks: A Framework for Approximating Variational Equations with Error Control

Herein, we present a new approach to using neural networks to approximate the solutions of variational equations, based on the adaptive construction of a sequence of finite-dimensional sub-spaces whose basis functions are realizations of a sequence of neural networks. Here, the finite-dimensional subspaces are then used to define a standard Galerkin approximation of the variational equation. This approach enjoys a number of advantages, including: the sequential nature of the algorithm offers a systematic approach to enhancing the accuracy of a given approximation; the sequential enhancements provide a useful indicator for the error that can be used as a criterion for terminating the sequential updates; the basic approach is largely oblivious to the nature of the partial differential equation under consideration; and, some basic theoretical results are presented regarding the convergence (or otherwise) of the method which are used to formulate basic guidelines for applying the method.

97 MATHEMATICS AND COMPUTING↗

Experimental Validation of a Command and Control Traffic Detection Model

Network intrusion detection systems (NIDS) are commonly used to detect malware communications, including command-and-control (C2) traffic from botnets. NIDS performance assessments have been studied for decades, but mathematical modeling has rarely been used to explore NIDS performance. This paper details a mathematical model that describes a NIDS performing packet inspection and its detection of malware's C2 traffic. Here, the paper further describes an emulation testbed and a set of cyber experiments that used the testbed to validate the model. These experiments included a commonly used NIDS (Snort) and traffic with contents from a pervasive malware (Emotet). Results are presented for two scenarios: a nominal scenario and a “stressed” scenario in which the NIDS cannot process all incoming packets. Model and experiment results match well, with model estimates mostly falling within 95 % confidence intervals on the experiment means. Model results were produced 70-3000 times faster than the experimental results. Consequently, the model's predictive capability could potentially be used to support decisions about NIDS configuration and effectiveness that require high confidence results, quantification of uncertainty, and exploration of large parameter spaces. Furthermore, the experiments provide an example for how emulation testbeds can be used to validate cyber models that include stochastic variability.

mathematical model↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters

Smart inverters (SIs) have demonstrated their potential to provide grid services for both transmission and distribution systems. One of these grid services, distribution network voltage regulation by SIs, has the potential to improve network voltage regulation through controlling the reactive and active power output of the SIs. Voltage regulation by SIs will be distributed and might be better suited to controlling local conditions to complement traditional voltage-regulating assets, e.g., tap-changing transformers, capacitor banks, and line voltage regulators. There is a gap in the literature on comparing the SI response characteristics when the SIs are controlled by a local controller or external control signals. This paper presents an experimental study to characterize SI reactive power regulation responses to two different control methods: autonomous control and remote dispatch. We found that SI reactive power regulation responses exhibit important differences between these methods in terms of delays and ramp rate. Finally, power-hardware-in-the-loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL test results show that the SI response characteristics for autonomous control and remote dispatch need to be considered when planning for distribution network voltage regulation using SIs.

autonomous control↗

Dynamics of streamflow permanence in a headwater network: Insights from catchment-scale model simulations

The hillslope and channel dynamics that govern streamflow permanence in headwater systems have important implications for ecosystem functioning and downstream water quality. Recent advancements in process-based, semi-distributed hydrologic models that build upon empirical studies of streamflow permanence in well-monitored headwater catchments show promise for characterizing the dynamics of streamflow permanence in headwater systems. However, few process-based models consider the continuum of hillslope-stream network connectivity as a control on streamflow permanence in headwater systems. The objective of this study was to expand a process-based, catchment-scale hydrologic model to better understand the spatiotemporal dynamics of headwater streamflow permanence and to identify controls of streamflow expansion and contraction in a headwater network. Further, we aimed to develop an approach that enhanced the fidelity of model simulations, yet required little additional data, with the intent that the model might be later transferred to catchments with limited long-term and spatially explicit measurements. This approach facilitated network-scale estimates of the controls of streamflow expansion and contraction, albeit with higher degrees of uncertainty in individual reaches due to data constraints. Our model simulated that streamflow permanence was highly dynamic in first-order reaches with steep slopes and variable contributing areas. The simulated stream network length ranged from nearly 98±2% of the geomorphic channel extent during wet periods to nearly 50±10% during dry periods. The model identified a discharge threshold of approximately 1 mm d –1 , above which the rate of streamflow expansion decreases by nearly an order of magnitude, indicating a lack of sensitivity of streamflow expansion to hydrologic forcing during high-flow periods. Overall, we demonstrate that process-based, catchment-scale models offer important insights on the controls of streamflow permanence, despite uncertainties and limitations of the model. We encourage researchers to increase data collection efforts and develop benchmarks to better evaluate such models.

54 ENVIRONMENTAL SCIENCES↗

Adaptive primal–dual control for distributed energy resource management

With the increased adoption of distributed energy resources (DERs) in distribution networks, their coordinated control with a DER management system (DERMS) that provides grid services (e.g., voltage regulation, virtual power plant) is becoming more necessary. One particular type of DERMS using primal–dual control has recently been found to be very effective at providing multiple grid services among an aggregation of DERs; however, the main parameter, the primal–dual step size, must be manually tuned for the DERMS to be effective, which can take a considerable amount of engineering time and labor. To this end, we design a simple method that self-tunes the step size(s) and adapts it to changing system conditions. Additionally, it gives the DER management operator the ability to prioritize among possibly competing grid services. Here we evaluate the automatic tuning method on a simulation model of a real-world feeder in Colorado with data obtained from an electric utility. Through a variety of scenarios, we demonstrate that the DERMS with automatically and adaptively tuned step sizes provides higher-quality grid services than a DERMS with a manually tuned step size.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scalable, Physical Effects Measurable Microgrid for Cyber Resilience Analysis (SPEMMCRA)

The ability to advance state of the art automated protections for industrial control systems (ICS) has as a precursor in the ability to understand the tradeoff space. That is, to enable a cyber feedback loop in a control system environment you must first consider both the security mitigation available, the benefits and the impacts to the control system functionality when the mitigation is used. More damaging impacts could be precipitated that the mitigation was intended to rectify. This paper details networked ICS that controls a simulation of the frequency response represented with the swing equation. The microgrid loads and base generation can be balanced through the control of an emulated battery and power inverter. The simulated plant, which is implemented in Raspberry Pi computers, provides an inexpensive platform to realize the physical effects of cyber attacks to show the tradeoffs of available mitigatoins. This network design can include a commercial ICS controller to introduce real world implementation of feedback controls, and provides a scalable, physical effects measurable Microgrid for cyber resilience analysis (SPEMMCRA).

42 ENGINEERING↗

Decentralized Low-Rank State Estimation for Power Distribution Systems

This article considers the low-observability state estimation problem in power distribution networks and develops a decentralized state estimation algorithm leveraging the matrix completion methodology. Matrix completion has been shown to be an effective technique in state estimation that exploits the low dimensionality of the power system measurements to recover missing information. This technique can utilize an approximate (linear) load flow model, or it can be used with no physical models in a network where no information about the topology or line admittance is available. The direct application of matrix completion algorithms requires solving a semi-definite programming (SDP) problem, which becomes computationally challenging for large networks. We therefore develop a decentralized algorithm that capitalizes on the popular proximal alternating direction method of multipliers (proximal ADMM). The method allows us to distribute the computation among different areas of the network, leading to a scalable algorithm. By doing all computations at individual control areas and only communicating with neighboring areas, the algorithm eliminates the need for data to be sent to a central processing unit and thus increases efficiency and contributes to the goal of autonomous control of distribution networks. We illustrate the advantages of the proposed algorithm numerically using standard IEEE test cases.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Image-based solar estimates

An example device is configured to determine, based on a sky image of a portion of sky over a power distribution network and using a convolutional neural network (CNN)-based image regression model, an estimated global horizontal irradiance (GHI) value and manage or control the power distribution network using the estimated GHI value. The device may also be configured to determine, based on GHI values and aggregate load values for at least a portion of the power distribution network, using a Bayesian Structural Time Series model, an estimated photovoltaic power output value for the at least a portion of the power distribution network. The device may manage or control the power distribution network using the estimated photovoltaic power output value.

Bernstein, Andrey↗

Cooperative Systems in Presence of Cyber-Attacks: A Unified Framework for Resilient Control and Attack Identification

Here, this paper considers a cooperative control problem in presence of unknown attacks. The attacker aims at destabilizing the consensus dynamics by intercepting the system’s communication network and corrupting its local state feedback. We first revisit the virtual network based resilient control proposed in our previous work and provide a new interpretation and insights into its implementation. Based on these insights, a novel distributed algorithm is presented to detect and identify the compromised communication links. It is shown that it is not possible for the adversary to launch a harmful and stealthy attack by only manipulating the physical states being exchanged via the network. In addition, a new virtual network is proposed which makes it more difficult for the adversary to launch a stealthy attack even though it is also able to manipulate information being exchanged via the virtual network. A numerical example demonstrates that the proposed control framework achieves simultaneously resilient operation and real-time attack identification.

97 MATHEMATICS AND COMPUTING↗

Traffic Signal Control With Adaptive Online-Learning Scheme Using Multiple-Model Neural Networks

This article proposes a new traffic signal control algorithm to deal with unknown-traffic-system uncertainties and reduce delays in vehicle travel time. Unknown-traffic-system dynamics are approximated using a recurrent neural network (NN). To accurately identify the traffic system model, an online-learning scheme is developed to switch among a set of candidate NNs (i.e., multiple-model NNs) based on their estimation errors. Then, a bank of optimal signal-timing controllers is designed based on the online identification of the traffic system. Simulation studies have been carried out for the obtained control strategies using multiple-model NNs, and the desired results have been obtained. Moreover, compared with the widely used actuated traffic signal control schemes, it is shown that the proposed method can reduce vehicle travel delays and improve traffic system robustness.

99 GENERAL AND MISCELLANEOUS↗

Support for Reactor Operators in Case of Cyber-Security Threats (NEUP Final Report)

Increasing use of digital technology in nuclear power plants (NPPs) poses cyber-security as a crucial threat to public safety and to continuous energy production. Cyber-security risks are comprised of complex known and unknown interactions between various entities, system vulnerabilities, network protocols, human users and malicious attacks. There is little understanding or research geared towards plant operators’ response under cyber-security threats and operational procedures to cope with such threats. This is particularly critical when a cyber-security event masquerades as a safety incident or an evolving accident. Instead of leading operators to the remediation of the accident, the masked cyber event may lead them to circumvent the safety mechanisms of the plant. Given these challenges, the objective of this project is to develop a tool to characterize abnormal NPP events as “cyber” or “safety” incidents, and to further develop this tool as a real-time operator aid to assist in response to the incident. This NEUP Final Report summarizes the research efforts towards the above goals and the results in the following three aspects. First, a methodology for classifying abnormal NPP events as cyber-attacks or safety incidents was developed. This provides the basis for responding to potential cyber-attacks. In this methodology, the causal relationships between various variables (i.e., physical variables, network variables, and control variables) for a nuclear system under consideration are modeled using dynamic Bayesian networks. Based on observations of certain variables (i.e., the evidence), inference is performed to identify the state of hidden variables, which helps indicate the occurrence of cyber-attacks or safety incidents. The proposed methodology was applied to the full scope NPP simulator system at The Ohio State University as a case study. The result shows that the proposed methodology is capable of distinguishing between cyber-attacks and safety incidents. Second, a game-theoretic approach for responding to cyber-attacks on nuclear power plants was developed. This is the second major goal of the project, and the method is used to recommend optimal responses to reactor operators in the case of cyber-attacks. We consider two cases in this research. In the first case, the interaction between the defender (i.e., the reactor operator) and the attacker is modeled as a two-player, nonzero-sum, Markov game with an infinite time horizon. In the second case, we consider a semi-Markov game between the defender and the attacker within a finite time horizon. The model in the second case enables us to consider the time sensitive response of the defender. In each case, the method for deriving the Nash equilibrium is developed. The Nash Equilibrium of the game provides the valid prediction of both players’ actions because no single player can benefit from unilaterally deviating from the equilibrium policy if the other player adheres to his/hers, hence it provides the best response of the defender to cyber-attacks. The proposed method in each case is demonstrated through a simplified benchmark digital feedwater control system. Third, a prototype display is developed to integrate the above information. The prototype display depicts the communication information to the operator and incorporates the cyber-security tool developed by the team into the interface. It consists of the regular display in current control rooms, as well as a panel used to indicate the occurrence of cyber-attacks or safety events and a panel used to guide the operator’s response to detected cyber-attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neuroevolution Application to Collaborative and Heuristics-Based Connected and Autonomous Vehicle Cohort Simulation at Uncontrolled Intersection

Artificial intelligence is gaining tremendous attractiveness and showing great success in solving various problems, such as simplifying optimal control derivation. This work focuses on the application of Neuroevolution to the control of Connected and Autonomous Vehicle (CAV) cohorts operating at uncontrolled intersections. The proposed method implementation’s simplicity, thanks to the inclusion of heuristics and effective real-time performance are demonstrated. The resulting architecture achieves nearly ideal operating conditions in keeping the average speeds close to the speed limit. It achieves twice as high mean speed throughput as a controlled intersection, hence enabling lower travel time and mitigating energy inefficiencies from stop-and-go vehicle dynamics. Low deviation from the road speed limit is hence continuously sustained for cohorts of at most 50 m long. This limitation can be mitigated with additional lanes that the cohorts can split into. The concept also allows the testing and implementation of fast-turning lanes by simply replicating and reconnecting the control architecture at each new road crossing, enabling high scalability for complex road network analysis. The controller is also successfully validated within a high-fidelity vehicle dynamic environment, showing its potential for driverless vehicle control in addition to offering a new traffic control simulation model for future autonomous operation studies.

Jacquelin, Frederic (ORCID:0000000183154344)↗