Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Multiclass Flight Anomaly Detection Using Sensor Fusion Based on Dempster-Shafer Theory

As aviation systems in commercial operations continue to grow in complexity, the anomalies exhibited by these systems become more elaborate and difficult to detect. To address the challenge of detecting these complex anomalies, deep learning models have been used extensively in aviation anomaly detection studies, at the expense of end-user interpretability. Aiming to maintain the same level of interpretability as traditional threshold-exceedance methods, we continue our development of prediction models using ordinal patterns and their distributions throughout the flight. Specifically, this study extends our work into multiclass anomaly detection using sensor fusion based on Dempster-Shafer theory (DST), a second-order probability theory used to combine information from different sources of evidence. Our approach uses DST toreduce the uncertainty in the class predictions of an ensemble of classifiers. These classifiers rely on the similarity between flight data and class templates to make a prediction of the state of the aircraft. Our approach aims to take advantage of simple models trained on interpretable features (ordinal patterns) to correctly predict an anomaly and identify the flight dynamics linked to the anomaly. Our results show an improvement when using DST-based sensor fusion over simple majority voting. Additionally, our results provide insight into aircraft states linked to rare high-risk anomalies.

Risk detection↗

Molecularly Imprinted Polymer Sensor Empowered by Bound States in the Continuum for Selective Trace-Detection of TGF-beta

The integration of advanced materials and photonic nanostructures can lead to enhanced biodetection capabilities, crucial in clinical scenarios and point-of-care diagnostics, where simplified strategies are essential. Herein, a molecularly imprinted polymer (MIP) photonic nanostructure is demonstrated, which selectively binding to transforming growth factor-beta (TGF-β), in which the sensing transduction is enhanced by bound states in the continuum (BICs). The MIP operating as a synthetic antibody matrix and coupled with BIC resonance, enhances the optical response to TGF-β at imprinted sites, leading to an augmented detection capability, thoroughly evaluated through spectral shift and optical lever analogue readout. The validation underscores the MIP-BIC sensor capability to detect TGF-β in spiked saliva, achieving a limit of detection of 10 fM and a resolution of 0.5 pM at physiological concentrations, with a precision of two orders of magnitude above discrimination threshold in patients. The MIP tailored selectivity is highlighted by an imprinting factor of 52, showcasing the sensor resistance to interference from other analytes. The MIP-BIC sensor architecture streamlines the detection process eliminating the need for complex sandwich immunoassays and demonstrates the potential for high-precision quantification. This positions the system as a robust tool for biomarker detection, especially in real-world diagnostic scenarios.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantum AI Based Enhanced Detection of Dementia

Quantum computing has the potential to significantly improve the early detection of Alzheimer's Disease and Related Dementias (ADRD). Quantum-enhanced machine learning can be used to perform an early screening of Alzheimer's disease using brain imaging data based on dataset of MRI scans from both healthy individuals and those diagnosed with Alzheimer's. This study aims to demonstrate the potential of quantum transfer learning to enhance the performance of the classical deep learning model for dementia detection. Using the MRI sagittal images available in the OASIS-2 (64 demented and 72 non-demented subjects between 60 and 96 years), we show how quantum techniques can transform a suboptimal classical model into a more effective solution for dementia detection, highlighting their potential impact on advancing healthcare technology. We begin with a simple classical deep learning model with a significantly smaller number of parameters, which gives suboptimal performance on the problem. Then, we apply different configurations of quantum transfer learning based on the pre-trained weak classifier (Figure 1). We fix the weak classifier's initial convolutional layers at their fixed pre-trained parameters and replace the last set of dense layers with a dressed quantum circuit (DQN), which we train to enhance performance. We performed 4-fold cross-validation for both the classical and the hybrid quantum models and trained them using Pennylane's `default.qubit' simulator and IonQ's Aria-1 simulator (noisy simulation). We showed that with significantly fewer parameters, the quantum transfer learning-based hybrid models showed significant performance enhancement over the base weak classical deep learning model for dementia detection. To classify between a demented and non-demented subject, the accuracy of quantum-based AI methods improved by 6 to 14% compared to classical methods. The sensitivity of the models improved by 4 to 17%. This shows that there are fewer chances of misclassifying demented patients. Figure 2 compares the performance of the hybrid quantum models and their base classical model, and Table 1 summarizes the results. We illustrated that with assistance from quantum machine learning, it is possible to enhance detection for dementia based on brain images. This shows the potential for practical utility of quantum computing in ADRD research.

Bhowmik, Sounak [University of Tennessee, Knoxvill↗

Dual-Phase Malicious User Detection Scheme for IM-OFDMA Systems Using IQ Imbalance

Physical-layer security techniques have contributed to the achievement of various security objectives in an efficient and lightweight manner. Thus, these techniques have been widely considered for limited-resource networks such as Internet of Things networks. Among the different security objectives, malicious user detection by exploiting physical-layer parameters has demonstrated efficient performance. In this work, malicious user detection in the recently proposed index modulation-based orthogonal frequency division multiple access (IM-OFDMA) is addressed. The proposed malicious user detection scheme exploits the hardware impairments, especially the in-phase and quadrature imbalance parameters, for both legitimate and malicious users to design a dual-phase efficient detection scheme. The proposed scheme accounts for the special characteristics of IM-OFDMA transmission that are different from other multiple-access techniques. The performance of the proposed scheme was evaluated considering detection probability and false alarm probability performance metrics. Moreover, closed-form expressions of these metrics were derived for both phases and were validated by Monte Carlo simulation results under different configurations of IM-OFDMA systems.

Alaca, Ozgur [ORNL] (ORCID:0000000153713758)↗

Robust Spectral Anomaly Detection in EELS Spectral Images via 3D Convolutional Variational Autoencoders

Abstract A 3D Convolutional Variational Autoencoder (3D‐CVAE) is introduced for automated anomaly detection in electron energy‐loss spectroscopy spectrum imaging (EELS‐SI) data. This approach leverages the full 3D structure of EELS‐SI data to detect subtle spectral anomalies while preserving both spatial and spectral correlations across the datacube. By employing cross‐entropy loss and training on bulk spectra, the model learns to reconstruct bulk features characteristic of the defect‐free material. In exploring methods for anomaly detection, both the 3D‐CVAE approach and principal component analysis (PCA) are evaluated, testing their performance using FeL‐edge ΔEpeak shifts designed to simulate material defects. These results show that 3D‐CVAE achieves superior anomaly detection and maintains consistent performance across various shift magnitudes. The method demonstrates clear bimodal separation between bulk and anomalous spectra, enabling reliable classification. Further analysis verifies that lower‐dimensional representations are robust to anomalies in the data. While performance advantages over PCA diminish with decreasing anomaly concentration, our method maintains high reconstruction quality even in challenging, noise‐dominated spectral regions. This approach provides a robust framework for unsupervised automated detection of spectral anomalies in EELS‐SI data, particularly valuable for analyzing complex material systems.

Chemistry↗

Out-of-Distribution Detection and Radiological Data Monitoring Using Statistical Process Control

Abstract Machine learning (ML) models often fail with data that deviates from their training distribution. This is a significant concern for ML-enabled devices as data drift may lead to unexpected performance. This work introduces a new framework for out of distribution (OOD) detection and data drift monitoring that combines ML and geometric methods with statistical process control (SPC). We investigated different design choices, including methods for extracting feature representations and drift quantification for OOD detection in individual images and as an approach for input data monitoring. We evaluated the framework for both identifying OOD images and demonstrating the ability to detect shifts in data streams over time. We demonstrated a proof-of-concept via the following tasks: 1) differentiating axial vs. non-axial CT images, 2) differentiating CXR vs. other radiographic imaging modalities, and 3) differentiating adult CXR vs. pediatric CXR. For the identification of individual OOD images, our framework achieved high sensitivity in detecting OOD inputs: 0.980 in CT, 0.984 in CXR, and 0.854 in pediatric CXR. Our framework is also adept at monitoring data streams and identifying the time a drift occurred. In our simulations tracking drift over time, it effectively detected a shift from CXR to non-CXR instantly, a transition from axial to non-axial CT within few days, and a drift from adult to pediatric CXRs within a day—all while maintaining a low false positive rate. Through additional experiments, we demonstrate the framework is modality-agnostic and independent from the underlying model structure, making it highly customizable for specific applications and broadly applicable across different imaging modalities and deployed ML models.

Zamzmi, Ghada↗

Exceptional NH 3 Detection by Cu(cyhdc) MOF Sensor Due to H 2 O Coadsorption

Metal–organic framework (MOF)-based electrical impedance sensors are a growing class of sensors that show utility in the detection of environmentally toxic gases. Detection of trace NH 3 has been particularly difficult to design due to the low electrical response of NH 3 . However, this has been circumvented by judiciously selecting a MOF that has enhanced electrical response to NH 3 due to coadsorption with predominant atmospheric gases such as water. Herein, an MOF Cu(cyhdc) based sensor has been successfully demonstrated for the enhanced detection of environmentally toxic NH 3 gas. The sensor shows a change in impedance when it is exposed to 5 ppm of NH 3 . At 20 °C, >30% relative humidity (RH) is necessary to elicit a change, with the response increasing with RH and reaching 3170× at 92% RH, producing the largest published response to NH 3 for a MOF direct electrical sensor. In the absence of water, no change is observed toward 5 ppm of NH 3 over 20–50 °C. Here, this electrical response is largely driven by huge decreases in the imaginary component of the impedance, attributed to increased capacitance at the surface of the MOF crystallites upon NH 3 and H 2 O coadsorption. Complementary structural and microstructural characterization proves that the Cu(cyhdc) crystalline structure and morphology remain intact under trace NH 3 and/or H 2 O adsorption. Despite extremely low NH 3 , loadings seen in TGA, XPS, and FT-IR confirm NH 3 and H 2 O adsorption, and changes to the metal-carboxylate IR peak positions are observed upon NH 3 adsorption. Concentrated primarily at the outer surfaces of the MOF crystallites, this NH 3 and H 2 O coadsorption effectively increases the surface capacitance across the Cu(cyhdc) powder and enables direct electrical detection of trace NH 3 . Together, these results demonstrate how coadsorption of specific molecules (H 2 O) can be used to enable the electrical detection of trace toxic gases that would otherwise not have produced a MOF sensor response.

ammonia↗

Copper-Based Two-Dimensional Conductive Metal–Organic Framework Thin Films for Ultrasensitive Detection of Perfluoroalkyls in Drinking Water

Perfluoroalkyls (PFAS) continue to emerge as a global health threat making their effective detection and capture extremely important. Though metal–organic frameworks (MOFs) have stood out as a promising class of porous materials for sensing PFAS, detection limits remain insufficient and a fundamental understanding of detection mechanisms warrants further investigation. Here, in this study, we show the use of a 2D conductive MOF film based on copper hexahydroxy triphenylene (Cu-HHTP) to fabricate chemiresistive sensing devices for detecting PFAS in drinking water. We further show ultrasensitive detection using electrochemical impedance spectroscopy. Owing to excellent electrostatic attractions and electrochemical interactions between the copper-based MOF and PFAS, confirmed by high-resolution spectroscopy and theoretical simulations, the MOF-based sensor reported herein exhibits excellent affinity and sensitivity toward perfluorinated acids at concentrations as low as 0.002 ng/L.

2D metal−organic frameworks↗

Exploring Approaches for Accelerated Mass Spectrometric Detection of Fluorochemicals from Aqueous Solutions Using Indirect, Adsorbent-Facilitated Desorption Ionization

There is a growing need for rapid, low-cost analytical tools to screen water supplies for persistent contaminants. Due to their ubiquitous presence in the environment and their detrimental effects on human health, there is a public interest in widespread testing for perfluoroalkyl substances (PFAS). However, the most common methods for PFAS analysis can be time-intensive, requiring a preconcentration step followed by liquid chromatography–mass spectrometry (LC–MS), and are cost-prohibitive for most members of the public. To address these challenges, this study explores a novel method for rapid analysis of aqueous analytes by concentrating analytes on solid adsorbents and detecting them using mass spectrometric analysis via desorption ionization directly from the adsorbent surface. We demonstrate this general approach of indirect solution analysis (ISA) with desorption electrospray ionization (ISA-DESI) and laser desorption ionization (ISA-LDI). Various adsorbent materials were screened, including commercial mesoporous carbons, alumina, and metal–organic frameworks (MOFs). Using ISA-DESI, we consistently detect concentrations as low as 5–100 parts per trillion (ppt) for perfluorooctanoic acid (PFOA) and 10–100 ppt for perfluoroundecanoic acid (PFUnDA). This approach enables rapid detection in under 5 min, making it suitable for applications requiring trace detection with fast response times. We further demonstrate the use of ISA-DESI on a range of environmentally relevant contaminants. Advantages of this indirect solution analysis approach include simplified sample preparation, accelerated analysis, and low cost with readily available materials, making it a promising tool to accelerate mass spectrometric PFAS detection for identifying contaminated sites, performing laboratory studies, and monitoring industrial waste streams.

Bays, Nathan Robert [Sandia National Laboratories ↗

Regional and Temporal Variability of Atmospheric River Seasonality: Influences of Detection Algorithms and Moisture Transport Dynamics

Abstract Understanding the regional and temporal variability of atmospheric river (AR) seasonality is crucial for preparedness and mitigation of extreme events. While ARs were thought to peak in winter, recent research shows they exhibit region‐specific seasonality and are heavily influenced by the chosen detection algorithm. This study examines the link between the year‐to‐year consistency of peak‐AR activity to the presence of a dominant seasonal pattern, considering both location and algorithm choice. Regions are categorized by their temporal characteristics: consistent patterns (e.g., East Asia), patterns with occasional outliers (e.g., British Columbia coast), and regions lacking a clear dominant peak season (e.g., South Atlantic, parts of Australia). Hence, not all regions display a consistent seasonal cycle of AR activity. This study quantifies the extent to which a region experiences a dominant peak season of AR activity (or lacks one) and offers insights to enhance decision‐making in water management, natural hazard preparedness, and forecasting. Furthermore, given our finding that detection algorithms influence the peak season of AR activity, we also examine two diagnostic variables representative of moisture transport to corroborate our results. Integrated vapor transport, which captures meridional and zonal moisture transport, and Moist Wave Activity, representing moisture intrusions from lower to higher latitudes, are examined. Our analysis indicates that inconsistencies in the seasonal cycle of AR activity are not solely due to discrepancies in detection algorithms but also arise from changes in moisture transport. Plain Language Summary Atmospheric rivers (ARs) are critical weather phenomena that can cause extreme events like heavy rainfall and flooding. Understanding when and where ARs are most likely to occur throughout the year is essential for preparing and responding to these events. Traditionally, ARs were thought to peak in winter, but recent studies show this varies by region. Our study helps address the challenge decision‐makers face in anticipating and preparing for AR events by providing insights into the consistency of peak seasonal patterns across different areas. Some regions, like East Asia, and the British Columbia coast, show a consistent peak season, while others, like the South Atlantic and parts of Australia, have significant year‐to‐year variations, making it hard to identify a dominant season. To better understand these changes over time, the study also examines how moisture moves in the atmosphere, using Integrated Vapor Transport (which looks at moisture movement in various directions) and Moist Wave Activity (which tracks moisture shifts from lower to higher latitudes). The findings suggest that inconsistencies in AR patterns are due not only to detection methods but also due to changes in moisture transport. Key Points The peak season of atmospheric river activity can change depending on the year in some areas Interannual variations in the peak season can make identifying a dominant season challenging for some regions Frequent shifts in peak season across years reflect inconsistencies tied to detection algorithms and to underlying dynamics

Kamnani, Diya↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Detection of Br and I as atomic anions using liquid sampling – atmospheric pressure glow discharge/Orbitrap mass spectrometry

The quantification and determination of halogen isotope composition is essential in many fields including geochemistry and nuclear forensics. Detection of the halogen elements is commonly attempted with inductively coupled plasma mass spectrometry (ICP-MS) however, there are multiple challenges faced. Most significantly this includes very poor ionization efficiency and the potential for isobaric interferences from either matrix or plasma species. Thus, sensitivity and accuracy are often limiting issues. Here a liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source is coupled with an ultrahigh resolution Orbitrap MS to perform halogen detection of bromine and iodine as initial analytes. This facilitates simple and sensitive detection of these elements as atomic anions from simple aqueous salt solutions. Collision-induced dissociation (CID) and higher-energy collisional dissociation (HCD) energies were optimized to produce the maximum response of Br − and I − . The LS-APGD conditions were optimized using a design of experiments (DOE) approach for Br − and I − concurrently. Response curves for Br − and I − solutions determined limit of detection (LOD) values of 50 pg and 5 pg, respectively, in 20 μL aliquots. The curves indicated response factors of 0.67 for 79 Br − and 0.90 for 127 I − . Br isotope ratios were determined with precision between 0.7 and 7.3% RSD, with the isotope ratios determined with precision 0.8% RSD at concentrations above the limit of quantification. Preliminary tests were conducted to evaluate the effect of different cations (Na + , K + , and Mg 2+ ) on Br − responses, with no discernible impacts observed on the halogen signal responses. This study demonstrates the potential use of the LS-APGD-Orbitrap-MS for the detection of multiple halogens while avoiding interferences, minimizing sample preparation, and overcoming ionization barriers.

Lang, Dehlia A. [Clemson University, SC (United St↗

Cyberattack Detection and Mitigation on Central Volt‐VAr Using Circuit Law and Machine Learning

ABSTRACT In a distribution grid, voltage is maintained within a nominal range through a Volt‐VAr function that controls capacitor banks, reactive power of distributed energy resources (DER), and on‐load tap changers (OLTC). Availability of communications helps with the implementation of central Volt‐VAr control; however, it also opens the system to cyberattacks, causing voltage disturbances. Previous work has shown the adverse impacts of false data injection (FDI) on the central Volt‐VAr control; however, very few works have studied methods to detect and mitigate FDI on Volt‐VAr control. This paper addresses gaps in the detection and mitigation of FDI on the measurement packets of a central Volt‐VAr control. This work uses a two‐stage algorithm for cyberattack detection since the accuracy of a single‐stage machine learning (ML)–based detection method decreases while dealing with unseen data. The first stage is based on the verification of measurements against circuit laws, and the second stage utilizes a tree search algorithm and an ML method to detect the falsified data. This paper compares long short‐term memory (LSTM) and bidirectional LSTM (BiLSTM) as the employed ML algorithms. Finally, the mitigation algorithm replaces the falsified data with the estimated output of the ML algorithm. The effectiveness of the proposed method is tested for several cases using the IEEE 13‐bus test system in PSCAD software.

Beikbabaei, Milad [Bradley Department of Electrica↗

Selection function of clusters in Dark Energy Survey year 3 data from cross-matching with South Pole Telescope detections

Context. Galaxy clusters selected based on overdensities of galaxies in photometric surveys provide the largest cluster samples. However, modeling the selection function of such samples is complicated by noncluster members projected along the line of sight (projection effects) and the potential detection of unvirialized objects (contamination). Aims. We empirically constrained the magnitude of these effects by cross-matching galaxy clusters selected in the Dark Energy Survey data with the redMaPPer algorithm with significant detections in three South Pole Telescope surveys (SZ, pol-ECS, pol-500d). Methods. For matched clusters, we augmented the redMaPPer catalog with the SPT detection significance. For unmatched objects we used the SPT detection threshold as an upper limit on the SZe signature. Using a Bayesian population model applied to the collected multiwavelength data, we explored various physically motivated models to describe the relationship between observed richness and halo mass. Results. Our analysis reveals a clear preference for models with an additional skewed scatter component associated with projection effects over a purely log-normal scatter model. We rule out significant contamination by unvirialized objects at the high-richness end of the sample. While dedicated simulations offer a well-fitting calibration of projection effects, our findings suggest the presence of redshift-dependent trends that these simulations may not have captured. Our findings highlight that modeling the selection function of optically detected clusters remains a complicated challenge that requires a combination of simulation and data-driven approaches.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-time signal detection for Cyclotron Radiation Emission Spectroscopy measurements using antenna arrays

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40 meV, requiring a large supply of tritium atoms stored in a multi-cubic meter detector volume. Antenna arrays are one potential technology compatible with an experiment of this scale, but the capability of an antenna-based CRES experiment to measure the neutrino mass depends on the efficiency of the signal detection algorithms. Here, in this paper, we develop efficiency models for three signal detection algorithms and compare them using simulations from a prototype antenna-based CRES experiment as a case-study. The algorithms include a power threshold, a matched filter template bank, and a neural network based machine learning approach, which are analyzed in terms of their average detection efficiency and relative computational cost. It is found that significant improvements in detection efficiency and, therefore, neutrino mass sensitivity are achievable, with only a moderate increase in computation cost, by utilizing either the matched filter or machine learning approach in place of a power threshold, which is the baseline signal detection algorithm used in previous CRES experiments by Project 8.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Silicon Photomultiplier Photon Detection Efficiency at Liquid Nitrogen Temperature

The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect scintillation light either directly or after it has been wavelength-shifted. Maximizing the photon detection efficiency (PDE) of the SiPMs used in these experiments optimizes the sensitivity to new physics; however, the PDEs of commercial SiPMs, although well known at room temperature, are not well characterized at the cryogenic temperatures at which many experiments operate them. Here we present results from an experimental setup that measures the photon detection efficiencies of silicon photomultipliers at liquid nitrogen temperature, 77 K. Results from a KETEK PM3325-WB-D0 and a Hamamatsu S13360-3050CS silicon photomultiplier — of R&D interest to the LEGEND experiment — exhibit a decrease in photon detection efficiency greater than 20% at liquid nitrogen temperature relative to room temperature for 562 nm light.

Cryogenic detectors↗

Mapping the cosmic gamma-ray horizon: the 1CGH catalogue of Fermi -LAT detections above 10 GeV

ABSTRACT We present the First Cosmic Gamma-ray Horizon (1CGH) catalogue, featuring $\gamma$-ray detections above 10 GeV based on 16 yr of observations with the Fermi Large Area Telescope (Fermi-LAT) satellite. After carefully selecting a sample of blazars and blazar candidates from catalogues in the literature, we performed a binned likelihood analysis and identified 2791 $\gamma$-ray emitters above 10 GeV, at >3$\sigma$ level, including 62 that are new $\gamma$-ray detections. For each source, we estimated the mean energy of the highest energy bin and analysed them in the context of the cosmic gamma-ray horizon. By adopting a reference model for the extragalactic background light (EBL), we identified a subsample of 525 sources where moderate to severe $\gamma$-ray absorption could be detected across the redshift range of 0–3. This work provides the most up-to-date compilation of detections above 10 GeV, along with their redshift information. We condense extensive results from the literature, including reports on observational campaigns dedicated to blazars and $\gamma$-ray sources, thereby delivering an unprecedented review of the redshift information for sources detected above 10 GeV. Additionally, we highlight key 1CGH sources where redshift information remains incomplete, offering guidance for future optical observation campaigns. The 1CGH catalogue aims to track the most significant sources for studying the $\gamma$-ray transparency of the Universe. Furthermore, it provides a targeted subsample where the EBL optical depth, $\tau _{(E,z)}$, can be robustly measured using Fermi-LAT data.

Arsioli, Bruno (ORCID:0000000181666602)↗

Using strong lensing to detect subhaloes with steep inner density profiles

ABSTRACT The inner region of a subhalo’s density distribution is particularly sensitive to dark matter microphysics, with alternative dark matter models leading to both cored and steeply-rising inner density profiles. This work investigates how the lensing signature and detectability of dark matter subhaloes in mock HST-, Euclid-, and JWST-like strong lensing observations depend on the subhalo’s radial density profile, especially with regards to the inner power-law slope, $\beta$. We demonstrate that the minimum subhalo mass detectable along the Einstein ring of a system is strongly dependent on $\beta$. In particular, we show that subhaloes with $\beta = 2.2$ can be detected down to masses over an order-of-magnitude lower than their Navarro–Frenk–White (NFW) counterparts with $\beta = 1$. Importantly, we find that the detectability of subhaloes with steep inner profiles is minimally affected by increasing the complexity of the main lens galaxy’s mass model. This is a notable characteristic of these subhaloes, as those with NFW or shallower profiles become essentially undetectable when multipole perturbations are added to the lens model. The results of this work highlight how the underlying dark matter physics can significantly impact the expected number of subhalo detections from strong gravitational lensing observations. This is important for testing Cold Dark Matter against alternative models, such as Self-Interacting Dark Matter, that predict a diverse range of subhalo inner density profiles.

dark matter↗