Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

Investigating Resilience of Loops in HPC Programs: A Semantic Approach with LLMs

Soft errors have become one of the major concerns for the error resilience of the HPC applications as those errors may cause HPC applications to generate serious outcomes such as silent data corruptions (SDCs). Protecting the applications from soft errors is an essential while challenging task. Among different approaches, obtaining a profound understanding of the resilience proneness of an application is very important to devise efficient error detection and recovery strategies. Given the scale of the HPC applications both in the code size and execution time, there are often cases that the error propagation analysis on such applications would produce a massive volume of unstructured data, which requires a significant amount of efforts, to process and to obtain indicating actions towards error protection. In this paper, we present a control-flow based visual analysis framework to help the users conduct error propagation analysis and identify the critical sections of a program that may have a higher likelihood of leading to erroneous outcomes when affected by the control flow related errors. We also design and implement the scalable visualization framework - ResilienceVis that efficiently and effectively visualizes the affected program states under errors and the propagation traces for an application in a user-friendly manner, and eventually, we combine the analysis and visualization to exhibit the error-proneness of the different sections of applications.

Jiang, Hailong↗

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

Unconventional Applications of Superconducting Nanowire Single Photon Detectors

Superconducting nanowire single photon detectors are becoming a dominant technology in quantum optics and quantum communication, primarily because of their low timing jitter and capability to detect individual low-energy photons with high quantum efficiencies. However, other desirable characteristics, such as high detection rates, operation in cryogenic and high magnetic field environments, or high-efficiency detection of charged particles, are underrepresented in literature, potentially leading to a lack of interest in other fields that might benefit from this technology. We review the progress in use of superconducting nanowire technology in photon and particle detection outside of the usual areas of physics, with emphasis on the potential use in ongoing and future experiments in nuclear and high energy physics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Halide Perovskites and Their Derivatives for Efficient, High‐Resolution Direct Radiation Detection: Design Strategies and Applications

Abstract The past decade has witnessed a rapid rise in the performance of optoelectronic devices based on lead‐halide perovskites (LHPs). The large mobility‐lifetime products and defect tolerance of these materials, essential for optoelectronics, also make them well‐suited for radiation detectors, especially given the heavy elements present, which is essential for strong X‐ray and γ‐ray attenuation. Over the past decade, LHP thick films, wafers, and single crystals have given rise to direct radiation detectors that have outperformed incumbent technologies in terms of sensitivity (reported values up to 3.5 × 10 6 µC Gy air −1 cm −2 ), limit of detection (directly measured values down to 1.5 nGy air s −1 ), along with competitive energy and imaging resolution at room temperature. At the same time, lead‐free perovskite‐inspired materials (e.g., methylammonium bismuth iodide), which have underperformed in solar cells, have recently matched and, in some areas (e.g., in polarization stability), surpassed the performance of LHP detectors. These advances open up opportunities to achieve devices for safer medical imaging, as well as more effective non‐invasive analysis for security, nuclear safety, or product inspection applications. Herein, the principles behind the rapid rises in performance of LHP and perovskite‐inspired material detectors, and how their properties and performance link with critical applications in non‐invasive diagnostics are discussed. The key strategies to engineer the performance of these materials, and the important challenges to overcome to commercialize these new technologies are also discussed.

36 MATERIALS SCIENCE↗

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗

Time-lapse seismic inversion for CO 2 saturation with SeisCO2Net: An application to Frio-II site

Seismic monitoring of geological CO 2 storage (GCS) involves highly nonlinear seismic inversion and petrophysical inversion, making it challenging to estimate CO 2 volume efficiently and detect possible early CO 2 leakages. Deep learning (DL) using convolutional neural networks (CNNs) has shown promise in solving highly nonlinear seismic inversion problems. However, direct estimation of CO 2 plume extent/saturation from time-lapse seismic gathers using DL is still underexplored, with no reported field applications to date. The investigation of field data is primarily hindered by scarcity of field data for neural network training. Other obstacles include highly nonlinear seismic-petrophysics inverse relationship, and presence of noise in field seismic data. We introduce SeisCO2Net, a deep CNN that predicts CO 2 saturation maps directly from time-lapse full waveform shot gathers. For training, we use site-specific geological information, fluid flow physics, rock physics, and seismic modeling to generate synthetic datasets that closely resemble the CO 2 storage site. Synthetic tests show promising results, inspiring us to apply SeisCO2Net's trained weights on field data collected at Frio-II GCS site by leveraging transfer learning principles. As reference, we compare SeisCO2Net's predicted CO 2 saturation maps with results obtained from physics-based inversion. Our analyses show both methods display similar CO 2 plume shapes, reasonable CO 2 plume characteristics, and comparable saturation values. Our results suggest pre-training CNNs on physics-informed synthetic datasets and then applying the learned weights to field data is a viable approach to estimating field CO 2 saturation. This method effectively addresses the scarcity of field training data, thus encouraging the feasibility of long-term GCS monitoring.

58 GEOSCIENCES↗

Hadron blind Cherenkov counters

A Hadron Blind Detector, or HBD, is a novel form of Cherenkov counter that is designed to provide high efficiency for detecting highly relativistic electrons while being essentially blind to most hadrons. Herein, we present some of the most prominent realizations of the HBD concept in real experiments. We describe the first implementation of an HBD that was made in the CERES experiment at CERN using a spectrometer based on a doublet of hadron blind RICH detectors for the measurement of low-mass electron pairs in pA and AA collisions at the SPS. We next present a detailed account of a more extensive realization of the HBD that was made in the PHENIX experiment for the measurement of low-mass electron pairs in central heavy-ion collisions at RHIC, followed by a description of a very similar detector that is currently under construction at J-PARC for the measurement of vector mesons through their e + e – decay in pA collisions. We conclude with a brief discussion of possible evolutions of the HBD concept as well as possible developments and uses of HBDs in experiments at the future Electron Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Designing Porous Ion Emitters for Thermal Ionization Mass Spectrometry: Evaluating Metal-Organic Frameworks

In this work we describe the first exploration of metal-organic frameworks (MOFs) as ‘next generation’ ion emitters for thermal ionization mass spectrometry (TIMS). MOFs were identified as promising candidates for this application given the synthetic control over their desired structural properties. This tunability results in well-ordered, high surface area, high porosity frameworks with targeted sorption affinities. Here we explored an aluminum-based, bipyridine-containing MOF (MOF-253) with and without incorporating the high work function metal, rhenium (Re). After analysis of a Nd-bearing MOF, we hypothesized that the well-dispersed, sponge-like interconnected network of the degraded structure would enhance Nd ionization more than traditional TIMS loading activators (i.e., phosphoric acid). Compared to filaments loaded with phosphoric acid that require an additional benzene carburization step, the Nd ionization efficiencies (atoms detected relative to atoms loaded) for heated filaments loaded with MOF-253 were similar (~1%). Electron microscopy after TIMS analysis demonstrated that the MOF was retained on the filament and, as hypothesized, preserved sub-micron porosity post analysis. While these results are preliminary, they demonstrate that MOFs have potential to enhance ionization and exceed the performance of traditional loading techniques by forming nano-porous ion emitters (nano-PIEs). Thus, further experimentation is likely to exceed this performance through more specific selection of the base MOF structure and modifications to porosity and composition. This work represents a novel application of MOFs and a next step in the pursuit of advanced thermal ionization with potential to expand across the periodic table.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facile Decomposition of Organophosphonates by Dual Lewis Sites on a Fe 3 O 4 (111) Film

Dimethyl methylphosphonate (DMMP) is used as a simulant for toxic nerve agents and pesticides, rendering the understanding of surface chemistry requisite to design effective materials for organophosphonate (catalytic) decomposition at room temperature. In this work, DMMP surface chemistry is studied on an iron oxide surface in a very well-defined environment using temperature-programmed reaction, isotopic labeling, scanning tunneling microscopy, X-ray photoelectron spectroscopy, and density functional theory. DMMP, (CH 3 O) 2 P(O)(CH 3 ), dissociates to yield methoxy and methyl methylphosphonate, (CH 3 O)P(O) 2 (CH 3 ), on the surface at room temperature. At higher temperatures, dimethyl ether is formed via intramolecular reaction, followed by the formation of formaldehyde and methanol from adsorbed methoxy decomposition during temperature-programmed reaction. Ultimately, stochiometric combustion at 870 K produces CO, H 2 C=O, and CO 2 via reaction with lattice oxygen, with PO x remaining on the surface. Excess oxygen from the bulk is required to drive these higher temperature pathways. Neither hydrolysis nor a photoreaction is observed, when exposing the adsorbed DMMP to water or light above the band gap, respectively. No evolution of P-containing species is detected, indicating efficient trapping of this contaminant. The activity for DMMP decomposition at room temperature is reduced by the accumulation of PO x . However, a significant amount of reaction persists after multiple temperature-programmed reaction experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

J-PLUS: Uncovering a large population of extreme [OIII] emitters in the local Universe

Over the past decades, several studies have discovered a population of galaxies that undergo very strong star formation events. They are called extreme emission line galaxies (EELGs). We exploit the capabilities of the Javalambre Photometric Local Universe Survey (J-PLUS), a wide-field multifilter survey, with which 2000 square degrees of the northern sky are already observed. We use it to identify EELGs at low redshift by their [OIII]5007 emission line. We intend to provide a more complete, deep, and less biased sample of local EELGs. We selected objects with an excess of flux in the J-PLUS medium-band J0515 filter, which covers the [OIII] line at z < 0.06. We removed contaminants (stars and higher-redshift systems) using J-PLUS and WISE infrared photometry, with SDSS spectra as a benchmark. We performed spectral energy distribution fitting to estimate the physical properties of the galaxies: line fluxes, equivalent widths (EWs), masses, stellar population ages, and so on. We identify 466 EELGs at z < 0.06 with [OIII] EW over 300 Å and an r-band magnitude below 20, of which 411 were previously unknown. Most show compact morphologies, low stellar masses (log(M • /M ⊙ ) ~ 8.13 –0.58 +0.61 ), low dust extinction (E( B–V ) ~ 0.1 –0.1 +0.2 ), and very young bursts of star formation (3.0 –2.0 +2.7 Myr). Our method is up to ~20 times more efficient in detecting EELGs per Mpc 3 than broadband surveys, and it is as complete as magnitude-limited spectroscopic surveys (but reaches fainter objects). The sample is not directly biased against strong Hα emitters, in contrast with works using broadband surveys. We demonstrate that J-PLUS can identify a large sample of previously unknown EELGs showing unique properties following a clear selection process. A fraction of the EELGs are probably similar to the first galaxies in the Universe, but they are at a much lower redshift, which makes them ideal targets for follow-up studies.

79 ASTRONOMY AND ASTROPHYSICS↗

An Arabinoxylan Extracted from Corn Grain Is Inhibitory to Cellulase Activity

The maize seed expression system is a powerful platform for recombinant protein production. It has been utilized for high-yield production of industrial cellulases such as endo-1,4-b-Dglucanase (E1) and 1,4-b-D-glucan cellobiohydrolases (CBHI & CBHII). However, inhibitory compounds that could significantly reduce the cellulolytic efficiency were detected even in purified E1 and CBHII samples. After several steps of purification and analysis, the inhibitory compound found in the purified E1 sample had characteristics consistent with a thermostable polysaccharide with a molecular size over 10 kDa. Further polysaccharide analysis confirmed the molecular size of the detected polysaccharide and suggested that it is an arabinoxylan with a high arabinose/xylose ratio. Even though the strict column purification process should have removed water soluble non-protein molecules during protein purification, the inhibitor remained. Here, a possible explanation is that recombinant cellulase can bind to the inhibitor, carry it through all purification steps and finally release it when denatured by heat.

59 BASIC BIOLOGICAL SCIENCES↗

Beyond Contrast Transfer: Spectral SNR as a Finite-Dose Metric for STEM Phase Retrieval

The contrast transfer function (CTF) is widely used to evaluate phase retrieval methods in scanning transmission electron microscopy (STEM), including center-of-mass imaging, parallax imaging, direct ptychography, and iterative ptychography. However, the CTF reflects only the maximum usable signal, neglecting the effects of finite electron fluence and the Poisson-limited nature of detection. As a result, it can significantly overestimate practical performance, especially in low-dose regimes. Here, we employ the spectral signal-to-noise ratio (SSNR), as a finite-dose statistical framework to evaluate the recoverable signal as a function of spatial frequency. Using numerical reconstructions of white-noise objects, we show that center-of-mass, parallax, and direct ptychography exhibit dose-independent SSNRs, with close-form analytic expressions. In contrast, iterative ptychography exhibits a surprising dose dependence: at low fluence, its SSNR converges to that of direct ptychography; at high fluence, it saturates at a value consistent with the maximum detective quantum efficiency predicted by recent quantum Fisher information bounds. The results highlight the limitations of CTF-based evaluation and motivate SSNR as a more accurate, finite-dose metric for assessing STEM phase retrieval methods.

STEM phase retrieval↗

Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths

Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. In this work, we report the angular dependence of the specular reflectance in vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of an FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cross Section Evaluation for Exclusive Channels of K+Λ and K+Σ0 Electroproduction off Protons Using CLAS Detector Data

In this work, a method for evaluating the cross sections of electroproduction of K+Λ0 and K+Σ0 off protons in the region of invariant masses of final hadrons MK + MY <W < 2.65 GeV (MK and MY being the masses of the kaon and hyperon, respectively) and squares of four-momentum transfers of virtual photons, i.e., photon virtualities 0 < Q2 < 5 GeV2, is developed based on experimental data of these exclusive channels’ cross sections measured by the CLAS detector in Hall B at Jefferson Lab. A set of algorithms has been implemented to evaluate the differential cross sections of these channels, along with their statistical and systematic uncertainties. A program was developed for the evaluation of differential cross sections and structure functions using C++ and Python libraries. An interactive website was created for working with the program, enabling the analysis of one-dimensional and two-dimensional dependences of structure functions and differential cross sections. The evaluation of differential cross sections for the K+Λ and K+Σ0 electroproduction channels is necessary for extracting the structure function σLT from the data on the polarization asymmetry of electroproduction reactions of these final states with longitudinally polarized electrons. The obtained results are also important for the development of realistic Monte Carlo event generators in planning future experiments and for evaluating the efficiency of detecting final particles when extracting reaction cross sections from experimental data.

Golda, A. V.↗