Search NASA⌕ Search

SEARCH · Search NASA

Results for “interferometric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Computational interferometric description of nested flow fields

Computer graphics and theoretical descriptions of density are used to obtain computer generated flow visualizations called computational interferograms. Computational interferograms are pictorially analogous to optical interferograms, and examples showing the fringe pattern for the flow about a sharp tip cone in a supersonic air stream are presented. To ascertain the effect of unsteady behavior, local density disturbances are added to the steady state flow field. This introduces irregularities to the computational interferogram like those seen in the optical interferograms. These theoretical disturbances can be varied in geometry, density description, translated with time, and strengthened or dissipated. The accuracy of computational interferometry relies on the accuracy of the theoretical density descriptions and therefore, it provides a way of verifying existing models of flow fields, especially those containing unsteady or turbulent behavior. In addition to being a unique method of flow visualization, computational interferometry can be used to develop and modify theories or numerical solutions to both simple and complex flow fields. The presented research is a general description of this process.

Havener, A. George↗

Interferometric phase velocity measurements in the auroral electrojet

A double-probe electric field detector and two spatially separated fixed-bias Langmuir probes were flown on a Taurus-Tomahawk sounding rocket launched from Poker Flat Research Range in March 1982. Interesting wave data have been obtained from about 10s of the downleg portion of the flight during which the rocket passed through the auroral electrojet. Here the electric field receiver and both density fluctuation (delta-n/n) receivers responded to a broad band of turbulence centered at 105 km-altitude and at frequencies generally below 4 kHz. Closer examination of the two delta-n/n turbulent waveforms reveals that they are correlated; from the phase difference between the two signals, the phase velocity of the waves in the rocket reference frame is inferred. The magnitude and direction of the observed phase velocity are consistent either with waves which travel at the ion sound speed or with waves which travel at the electron drift velocity. The observed phase velocity varies by about 50 percent over a 5 km altitude range, an effect which probably results from shear in the zonal neutral wind, although, unfortunately, no simultaneous neutral wind measurements exist to confirm this.

Labelle, J.↗

Development and applications of optical interferometric micrometrology in the angstrom and subangstrom range

The recent development of the scanning electron tunneling microscope and the atomic force microscope requires absolute standards for measurements in the angstrom and subangstrom range. Optical interferometry with lasers and multiple mode laser resonances can provide absolute measurements as the laser wavelengths are very accurately known. A key feature of such measurements is the use of piezoelectric crystals as translators of the highest accuracy for very small disturbances. However, the dimensional changes of these crystals resulting from electrical potential changes depend on many variables, among them the method of mounting, so that accurate calibrations are necessary. Starting from advances in optical metrology made by physicists trying to find gravity waves, advances which led to measurements down to 10 to the -5 A, the author designed and built a much simpler system for the angstrom range. The major limiting factors were mechanical vibrations, air currents, thermal changes and laser instabilities.

Lauer, James L.↗

Fiber-linked interferometric pressure sensor

A fiber-optic pressure sensor is described which uses a diaphragm to modulate the mirror separation of a Fabry-Perot cavity (the sensing cavity). A multimode optical fiber delivers broadband light to the sensing cavity and returns the spectrally modulated light which the cavity reflects. The sensor's output spectrum is analyzed using a tunable Fabry-Perot cavity (the reference cavity) to determine the mismatch in the mirror separations of the two cavities. An electronic servo control uses this result to cause the mirror separation of the reference cavity to equal that of the sensing cavity. The displacement of the pressure-sensing diaphragm is then obtained by measuring the capacitance of the reference cavity's metal-coated mirrors. Relative to other fiber-optic sensors, an important advantage of this instrument is its high immunity to the effects of variations in both the transmissivity of the fiber link and the wavelength of the optical source.

Beheim, G.↗

Radio-interferometric imaging of the subsurface emissions from the planet Mercury

The distribution of total and polarized intensities from Mercury's subsurface layers have been mapped using VLA observations. The first detection of a hot pole along the Hermean equator is reported and modeled as black-body reradiation from preferential diurnal heating. These observations appear to rule out any internal sources of heat within Mercury. Polarized emission from the limb of the planet is also found, and is understood in terms of the dielectric properties of the Hermean surface.

Burns, J. O.↗

Optical Interferometric Micrometrology

Resolutions in angstrom and subangstrom range sought for atomic-scale surface probes. Experimental optical micrometrological system built to demonstrate calibration of piezoelectric transducer to displacement sensitivity of few angstroms. Objective to develop relatively simple system producing and measuring translation, across surface of specimen, of stylus in atomic-force or scanning tunneling microscope. Laser interferometer used to calibrate piezoelectric transducer used in atomic-force microscope. Electronic portion of calibration system made of commercially available components.

Abel, Phillip B.↗

Facility for interferometric testing of 1.25-m mirrors at liquid helium temperatures

A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.

Salerno, Louis J.↗

Laser holographic interferometric measurements of the flow in a scramjet inlet at Mach 4

The need for quantitative data is addressed by laser holographic interferometry (LHI) by efficiently recording and reducing high resolution density data. This paper investigates the potential to get quantitative data from an interferogram created from two separate holographic plates. THe LHI measurements were made on a scramjet inlet at Mach 4. LHI successfully generated results for both internal and external flows, and demonstrated its ability to map entire flow fields. Of the three data reduction techniques used, the four-bucket method gave better results than the three-bucket or three-by-three methods. This technique requires high quality holograms as well as a good resolution in the digital images to produce good data.

Mcarthur, J. Craig↗

Development and applications of optical interferometric micrometrology in the Angstrom and subangstrom range

The characteristics of the scanning tunneling microscope and atomic force microscope (AFM) are briefly reviewed, and optical methods, mainly interferometry, of sufficient resolution to measure AFM deflections are discussed. The methods include optical resonators, laser interferometry, multiple-beam interferometry, and evanescent wave detection. Experimental results using AFM are reviewed.

Lauer, James L.↗

Interferometric Fiber-Optic Gyroscope

Integrated three-waveguide directional coupler functions as polarizer and splitter. Designed with transverse electric (TE) polarization in bar state (two coupling lengths) and transverse magnetic (TM) polarization in cross state (one coupling length). Intended for eventual fabrication as in mass-producible integrated optical circuit that provides advantages including low drive voltage, large-bandwidth phase modulation, preservation of polarization in transmission between devices on same substrate, and low cost.

Depaula, Ramon P.↗

An interferometric strain-displacement measurement system

A system for measuring the relative in-plane displacement over a gage length as short as 100 micrometers is described. Two closely spaced indentations are placed in a reflective specimen surface with a Vickers microhardness tester. Interference fringes are generated when they are illuminated with a He-Ne laser. As the distance between the indentations expands or contracts with applied load, the fringes move. This motion is monitored with a minicomputer-controlled system using linear diode arrays as sensors. Characteristics of the system are: (1) gage length ranging from 50 to 500 micrometers, but 100 micrometers is typical; (2) least-count resolution of approximately 0.0025 micrometer; and (3) sampling rate of 13 points per second. In addition, the measurement technique is non-contacting and non-reinforcing. It is useful for strain measurements over small gage lengths and for crack opening displacement measurements near crack tips. This report is a detailed description of a new system recently installed in the Mechanisms of Materials Branch at the NASA Langley Research Center. The intent is to enable a prospective user to evaluate the applicability of the system to a particular problem and assemble one if needed.

Sharpe, William N., Jr.↗

Facility for interferometric testing of 1.25-m mirrors at liquid helium temperatures

A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two-stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.

Salerno, Louis J.↗

Motion detection, novelty filtering, and target tracking using an interferometric technique with a GaAs phase conjugate mirror

A method and apparatus is disclosed for detecting and tracking moving objects in a noise environment cluttered with fast-and slow-moving objects and other time-varying background. A pair of phase conjugate light beams carrying the same spatial information commonly cancel each other out through an image subtraction process in a phase conjugate interferometer, wherein gratings are formed in a fast photo-refractive phase conjugate mirror material. In the steady state, there is no output. When the optical path of one of the two phase conjugate beams is suddenly changed, the return beam loses its phase conjugate nature and the inter-ferometer is out of balance, resulting in an observable output. The observable output lasts until the phase conjugate nature of the beam has recovered. The observable time of the output signal is roughly equal to the formation time of the grating. If the optical path changing time is slower than the formation time, the change of optical path becomes unobservable, because the index grating can follow the change. Thus, objects traveling at speeds which result in a path changing time which is slower than the formation time are not observable and do not clutter the output image view.

Cheng, Li-Jen↗

Interferometric molecular line observations of W51

Observations are presented of the H II region complex in W51 made with a mm interferometer. W51 is a region of massive star formation approx. 7 kpc distant from the sun. This region has been well studied in both the IR and submillimeter, the radio, as well as the maser transitions. These previous observations have revealed three regions of interest: (1) W51MAIN, a know of bright maser emission near two compact H II regions W51e1 and W51e2 (W51MAIN is also the peak of the 400 micron emission indicating that the bulk of the mass is centered there; (2) W51IRS1 is a long curving structure seen at 20 micron and at 2 and 6 cm but not at 400 micron; (3) W51IRS2 (also known as W51NORTH) is another compact H II region slightly offset from an 8 and a 20 micron peak and a collection of masers. Some conclusions are as follows: (1) SO and H(13)CN emission are similar and coincide with outflow activity; (2) HCO+ spectra show evidence for overall collapse of the W51 cloud toward W51MAIN; (3) A previously undetected continuum peak, W51DUST, coincides with the molecular peak H(13)CN-4; and (4) Dust emission at 3.4 mm reveals that about half of the 400 micron emission comes from the ultracompact H II region e2, and the rest from W51e1 and W51DUST.

Rudolph, Alexander↗

Three-dimensional computed tomography from interferometric measurements within a narrow cone of views

A theory to determine the properties of a fluid from measurements of its projections was developed and tested. Viewing cones as small as 10 degrees were evaluated, with the only assumption being that the property was space limited. The results of applying the theory to numerical and actual interferograms of a spherical discontinuity of refractive index are presented. The theory was developed to test the practicality and limits of using three-dimensional computer tomography in internal fluid dynamics.

Decker, Arthur J.↗

Spectra, composition and interactions of nuclei above 10 TeV using magnet-interferometric chambers (SCIN/MAGIC)

Initial definition studies were performed for the SCIN/MAGIC experiment selected as an Astromag investigation on Space Station Freedom. The study focused on Science Objectives and Science Requirement, Accommodation on both the STS and the Astromag facility, Data extraction techniques and Background Studies. The detectors are emulsion chambers which will be exposed for approximately 90 days and then recovered from orbit for subsequent processing and analysis in the laboratory. Such a technique is the only means to obtain information on the ultrahigh energy cosmic rays and their nuclear interactions. The SCIN/MAGIC investigation can supply unique data in relatively unexplored energy region and address many of the fundamental questions in particle astrophysics.

Wefel, John P.↗

Laser interferometric measurement of ion electrode shape and charge exchange erosion

A projected fringe profilometry system was applied to surface contour measurements of an accelerator electrode from an ion thrustor. The system permitted noncontact, nondestructive evaluation of the fine and gross structure of the electrode. A 3-D surface map of a dished electrode was generated without altering the electrode surface. The same system was used to examine charge exchange erosion pits near the periphery of the electrode to determine the depth, location, and volume of material lost. This electro-optical measurement system allowed rapid, nondestructive, digital data acquisition coupled with automated computer data processing. In addition, variable sensitivity allowed both coarse and fine measurements of objects having various surface finishes.

Macrae, Gregory S.↗