Search NASA⌕ Search

SEARCH · Search NASA

Results for “interval analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Fractal mechanisms and heart rate dynamics. Long-range correlations and their breakdown with disease

Under healthy conditions, the normal cardiac (sinus) interbeat interval fluctuates in a complex manner. Quantitative analysis using techniques adapted from statistical physics reveals the presence of long-range power-law correlations extending over thousands of heartbeats. This scale-invariant (fractal) behavior suggests that the regulatory system generating these fluctuations is operating far from equilibrium. In contrast, it is found that for subjects at high risk of sudden death (e.g., congestive heart failure patients), these long-range correlations break down. Application of fractal scaling analysis and related techniques provides new approaches to assessing cardiac risk and forecasting sudden cardiac death, as well as motivating development of novel physiologic models of systems that appear to be heterodynamic rather than homeostatic.

NASA Discipline Cardiopulmonary↗

Chirp Scaling Algorithms for SAR Processing

The chirp scaling SAR processing algorithm is both accurate and efficient. Successful implementation requires proper selection of the interval of output samples, which is a function of the chirp interval, signal sampling rate, and signal bandwidth. Analysis indicates that for both airborne and spaceborne SAR applications in the slant range domain a linear chirp scaling is sufficient. To perform nonlinear interpolation process such as to output ground range SAR images, one can use a nonlinear chirp scaling interpolator presented in this paper.

nonlinear chirp scaling.↗

Estimated Probability of a Cervical Spine Injury During an ISS Mission

Introduction: The Integrated Medical Model (IMM) utilizes historical data, cohort data, and external simulations as input factors to provide estimates of crew health, resource utilization and mission outcomes. The Cervical Spine Injury Module (CSIM) is an external simulation designed to provide the IMM with parameter estimates for 1) a probability distribution function (PDF) of the incidence rate, 2) the mean incidence rate, and 3) the standard deviation associated with the mean resulting from injury/trauma of the neck. Methods: An injury mechanism based on an idealized low-velocity blunt impact to the superior posterior thorax of an ISS crewmember was used as the simulated mission environment. As a result of this impact, the cervical spine is inertially loaded from the mass of the head producing an extension-flexion motion deforming the soft tissues of the neck. A multibody biomechanical model was developed to estimate the kinematic and dynamic response of the head-neck system from a prescribed acceleration profile. Logistic regression was performed on a dataset containing AIS1 soft tissue neck injuries from rear-end automobile collisions with published Neck Injury Criterion values producing an injury transfer function (ITF). An injury event scenario (IES) was constructed such that crew 1 is moving through a primary or standard translation path transferring large volume equipment impacting stationary crew 2. The incidence rate for this IES was estimated from in-flight data and used to calculate the probability of occurrence. The uncertainty in the model input factors were estimated from representative datasets and expressed in terms of probability distributions. A Monte Carlo Method utilizing simple random sampling was employed to propagate both aleatory and epistemic uncertain factors. Scatterplots and partial correlation coefficients (PCC) were generated to determine input factor sensitivity. CSIM was developed in the SimMechanics/Simulink environment with a Monte Carlo wrapper (MATLAB) used to integrate the components of the module. Results: The probability of generating an AIS1 soft tissue neck injury from the extension/flexion motion induced by a low-velocity blunt impact to the superior posterior thorax was fitted with a lognormal PDF with mean 0.26409, standard deviation 0.11353, standard error of mean 0.00114, and 95% confidence interval [0.26186, 0.26631]. Combining the probability of an AIS1 injury with the probability of IES occurrence was fitted with a Johnson SI PDF with mean 0.02772, standard deviation 0.02012, standard error of mean 0.00020, and 95% confidence interval [0.02733, 0.02812]. The input factor sensitivity analysis in descending order was IES incidence rate, ITF regression coefficient 1, impactor initial velocity, ITF regression coefficient 2, and all others (equipment mass, crew 1 body mass, crew 2 body mass) insignificant. Verification and Validation (V&V): The IMM V&V, based upon NASA STD 7009, was implemented which included an assessment of the data sets used to build CSIM. The documentation maintained includes source code comments and a technical report. The software code and documentation is under Subversion configuration management. Kinematic validation was performed by comparing the biomechanical model output to established corridors.

Brooker, John E.↗

Statistical Study of the Properties of Magnetosheath Lion Roars

Lion roars are narrowband whistler wave emissions that have been observed in several environments, such as planetary magnetosheaths, the Earth's magnetosphere, the solar wind, downstream of interplanetary shocks, and the cusp region. We present measurements of more than 30,000 such emissions observed by the Magnetospheric Multiscale spacecraft with high‐cadence (8,192 samples/s) search coil magnetometer data. A semiautomatic algorithm was used to identify the emissions, and an adaptive interval algorithm in conjunction with minimum variance analysis was used to determine their wave vector. The properties of the waves are determined in both the spacecraft and plasma rest frame. The mean wave normal angle, with respect to the background magnetic field (B(sub 0)), plasma bulk flow velocity (V(sub b)), and the coplanarity plane (V(sub b) × B(sub 0)) are 23°, 56°, and 0°, respectively. The average peak frequencies were ∼31% of the electron gyrofrequency (ω(sub ce)) observed in the spacecraft frame and ∼18% of ω(sub ce) in the plasma rest frame. In the spacecraft frame, ∼99% of the emissions had a frequency <ω(sub ce), while 98% had a peak frequency <0.72 ω(sub ce) in the plasma rest frame. None of the waves had frequencies lower than the lower hybrid frequency, ω. From the probability density function of the electron plasma β(sub e), the ratio between the electron thermal and magnetic pressure, ∼99.6% of the waves were observed with β(sub e)<4 with a large narrow peak at 0.07 and two smaller, but wider, peaks at 1.26 and 2.28, while the average value was ∼1.25.

Magnetosheath emissions↗

Dynamic Testing of a High-Specific-Torque Concentric Magnetic Gear

This paper presents initial measurements of the efficiency of NASA's 2nd magnetic gear prototype. A detailed discussion of the test rig's design and capabilities was presented, along with a thorough uncertainty analysis. The reported uncertainties are 95% confidence intervals that include the effects of temperature and parasitic loads. The prototype's response was measured at output speeds between 124 rpm and 744 rpm for a controlled output torque of 10 Nm (8% of the prototype's maximum torque). After correcting for tare losses, the prototype's efficiency was found to decrease from 90.0% to 83.0% as speed increased. If the efficiency is extrapolated to a typical operating condition (85% of maximum torque) using the good assumption that energy loss is approximately independent of the transmitted torque, the expected efficiency would be 99.0% to 98.4%, which exceeds the state of the art for these speeds.

magnetic gears↗

Dynamic Testing of a High-Specific-Torque Concentric Magnetic Gear

This presentation presents measurements of the efficiency of NASA's 2nd magnetic gear prototype. A detailed discussion of the test rig used to make these measurements was presented, including a thorough uncertainty analysis. The reported uncertainties are 95% confidence intervals that include the effects of temperature and parasitic loads. The prototype's response was measured at output speeds between 124 rpm and 744 rpm for a controlled output torque of 10 Nm (8% of the prototype's maximum torque). After correcting for tare losses, the prototype's efficiency was found to decrease from 90.0% to 83.0% as speed increased. If the efficiency is extrapolated to a typical operating condition (85% of maximum torque) using the good assumption that energy loss is approximately independent of the transmitted torque,the expected efficiency would be 99.0% to 98.4%, which exceeds the state of the art for these speeds.

Scheidler, Justin↗

High Speed Testing of a High Efficiency Concentric Magnetic Gear

This presentation presents measurements of the efficiency of NASA's 2nd magnetic gear prototype. A detailed discussion of the test rig used to make these measurements was presented, including a thorough uncertainty analysis. The reported uncertainties are 95% confidence intervals that include the effects of temperature and parasitic loads. The prototype's response was measured at output speeds between 124 rpm and 744 rpm for a controlled output torque of 10 Nm (8% of the prototype's maximum torque). After correcting for tare losses, the prototype's efficiency was found to decrease from 90.0% to 83.0% as speed increased. If the efficiency is extrapolated to a typical operating condition (85% of maximum torque) using the good assumption that energy loss is approximately independent of the transmitted torque,the expected efficiency would be 99.0% to 98.4%, which exceeds the state of the art for these speeds.

Scheidler, Justin↗

New Evidence on the Origin of Solar Wind Microstreams/Switchbacks

Microstreams are fluctuations in the solar wind speed and density associated with polarity-reversing folds in the magnetic field (also denoted switchbacks). Despite their long heritage, the origin of these microstreams/switchbacks remains poorly understood. For the first time, we investigated periodicities in microstreams during Parker Solar Probe (PSP) Encounter 10 to understand their origin. Our analysis was focused on the inbound corotation interval on 2021 November 19–21, while the spacecraft dove toward a small area within a coronal hole (CH). Solar Dynamics Observatory remote-sensing observations provide rich context for understanding the PSP in situ data. Extreme ultraviolet images from the Atmospheric Imaging Assembly reveal numerous recurrent jets occurring within the region that was magnetically connected to PSP during intervals that contained microstreams. The periods derived from the fluctuating radial velocities in the microstreams (approximately 3, 5, 10, and 20 minutes) are consistent with the periods measured in the emission intensity of the jetlets at the base of the CH plumes, as well as in larger coronal jets and in the plume fine structures. Helioseismic and Magnetic Imager magnetograms reveal the presence of myriad embedded bipoles, which are known sources of reconnection-driven jets on all scales. Simultaneous enhancements in the PSP proton flux and ionic ( 3 He, 4 He, Fe, O) composition during the microstreams further support the connection with jetlets and jets. In keeping with prior observational and numerical studies of impulsive coronal activity, we conclude that quasiperiodic jets generated by interchange/ breakout reconnection at CH bright points and plume bases are the most likely sources of the microstreams/ switchbacks observed in the solar wind.

Pankaj Kumar↗

Nevada Higher Education Benefits from US Department of Energy (DOE) Environmental Management (EM) Nevada Program's Transfer of Geologic Samples - 20442

The Nevada National Security Site (NNSS), formerly the Nevada Test Site, was the location of 100 historic atmospheric and 828 historic underground nuclear tests from 1951 to 1992. Related to this historic nuclear testing, geologic and hydrologic studies of the site were conducted utilizing the skills and the expertise of the U.S. Geological Survey (USGS) and national laboratories (Los Alamos National Laboratory, Lawrence Livermore National Laboratory), who were principal in leading the development of weapons and were responsible for specific underground testing programs. The subsurface samples and technical/scientific data associated with NNSS geologic studies (past and present) are preserved and stored at the USGS Mercury Core Library and Data Center located at the NNSS. Currently, the facility stores over 2,000,000 linear feet of cores and cuttings from more than 2,600 drill holes that can be accessed for study. Most of the samples and historic geologic work was focused directly on subsurface geologic settings that relate directly to historic underground nuclear testing. Since 1992, the United States has observed a unilateral moratorium on full-scale nuclear testing, and the U.S. Department of Energy (DOE) Environmental Management (EM) Nevada Program is now responsible for hydrogeologic characterization of the potential impacts to the natural groundwater systems that may have resulted from historic underground nuclear tests. As part of this effort, the EM Nevada Program Underground Test Area (UGTA) Activity has drilled and completed over 58 deep (2,000 - 7,000 ft.) characterization wells, totaling in excess of 170,000 linear feet of cuttings and core samples. Cutting samples were collected as triplicate samples for each respective depth interval, to account for potential later nondestructive/destructive analysis and to preserve samples for regulatory purposes. Recently, it was recognized by the EM Nevada Program that opportunities may exist to reduce the cost and floor space required for the storage of geologic samples at the Mercury Core Library without impacting the integrity and representative nature of the samples necessary for project execution. An initiative was sponsored by EM Nevada Program to evaluate several options: 1) disposal of a portion of cuttings and cores in a land fill setting; 2) reduction in sample volume through skeletonizing core and cuttings from wells to a representative but much smaller number of samples; and 3) solicit potential interest in the academic community where other geoscientists could freely access the samples for studies. The Nevada state university system through the Nevada Bureau of Mines and Geology responded positively to the opportunity to receive these NNSS samples from the EM Nevada Program. In June 2019, approximately 17,000 geologic samples, representing greater than 170,000 linear feet of drilling and weighing over 20,000 pounds, were shipped from the NNSS to the Great Basin Science Sample and Records Library located in Reno, Nevada. The benefits resulting from this transfer were realized by the EM Nevada Program in terms of cost and space savings for geologic sample storage at the NNSS. The transfer did not impact the EM Nevada Program mission as access to representative geologic samples for regulatory and scientific purposes was preserved. Moreover, the Nevada Bureau of Mines and Geology acquired a significant resource of subsurface geologic samples and supporting technical data to support academic and scientific studies in a complex volcanic setting in southwest Nevada. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High resolution time interval counter

In recent years, we have developed two types of high resolution, multi-channel time interval counters. In the NIST two-way time transfer MODEM application, the counter is designed for operating primarily in the interrupt-driven mode, with 3 start channels and 3 stop channels. The intended start and stop signals are 1 PPS, although other frequencies can also be applied to start and stop the count. The time interval counters used in the NIST Frequency Measurement and Analysis System are implemented with 7 start channels and 7 stop channels. Four of the 7 start channels are devoted to the frequencies of 1 MHz, 5 MHz or 10 MHz, while triggering signals to all other start and stop channels can range from 1 PPS to 100 kHz. Time interval interpolation plays a key role in achieving the high resolution time interval measurements for both counters. With a 10 MHz time base, both counters demonstrate a single-shot resolution of better than 40 ps, and a stability of better than 5 x 10(exp -12) (sigma(sub chi)(tau)) after self test of 1000 seconds). The maximum rate of time interval measurements (with no dead time) is 1.0 kHz for the counter used in the MODEM application and is 2.0 kHz for the counter used in the Frequency Measurement and Analysis System. The counters are implemented as plug-in units for an AT-compatible personal computer. This configuration provides an efficient way of using a computer not only to control and operate the counters, but also to store and process measured data.

Zhang, Victor S.↗

Capturing Maize Stand Heterogeneity Across Yield-Stability Zones Using Unmanned Aerial Vehicles (UAV)

Despite the new equipment capabilities, uneven crop stands are still common occurrences in crop fields, mainly due to spatial heterogeneity in soil conditions, seedling mortality due to herbivore predation and disease, or human error. Non-uniform plant stands may reduce grain yield in crops like maize. Thus, detecting signs of variability in crop stand density early in the season provides critical information for management decisions and crop yield forecasts. Processing techniques applied on images captured by unmanned aerial vehicles (UAVs) has been used successfully to identify crop rows and estimate stand density and, most recently, to estimate plant-to-plant interval distance. Here, we further test and apply an image processing algorithm on UAV images collected from yield-stability zones in a commercial crop field. Our objective was to implement the algorithm to compare variation of plant-spacing intervals to test whether yield differences within these zones are related to differences in crop stand characteristics. Our analysis indicates that the algorithm can be reliably used to estimate plant counts (precision >95% and recall >97%) and plant distance interval (R2 ~0.9 and relative error <10%). Analysis of the collected data indicated that plant spacing variability differences were small among plots with large yield differences, suggesting that it was not a major cause of yield variability across zones with distinct yield history. This analysis provides an example of how plant-detection algorithms can be applied to improve the understanding of patterns of spatial and temporal yield variability.

47 OTHER INSTRUMENTATION↗

Stereotactic Body Radiation Therapy for Spinal Metastases in the Postoperative Setting: A Secondary Analysis of Mature Phase 1-2 Trials

Purpose: To evaluate the outcomes in patients treated on prospective phase 1-2 protocols with postoperative stereotactic body radiation therapy (SBRT) and identify the associated prognostic variables. Methods and Materials: Sixty-six patients with 69 tumors were treated with SBRT on prospective phase 1-2 studies for spinal metastases between 2002 and 2010. All patients underwent SBRT after spine surgery, which included laminectomy, vertebrectomy, or a combination of these techniques. Renal cell carcinoma was the most common histology represented (n=35, 53%) followed by sarcomas (n=13, 20%). Thirty-one patients (47%) were treated with prior conventional radiation to the spine (median dose 30 Gy). Patients were followed up with spinal magnetic resonance imaging (MRI) studies to determine the treated tumor control (TC). Pain and other symptom data were collected prospectively to determine treatment response and toxicity. Results: The median follow-up time was 30 months (range, 1-145 months) for all patients and 75 months for living patients (range, 6-145 months). The actuarial 1-year rate of TC was 85%, adjacent vertebral body control was 85%, and overall survival (OS) was 74% (median 29 months). On multivariate competing-risks analysis, sarcoma histology (subhazard ratio [SHR] = 2.38, 95% confidence interval [CI] 1.05-5.6, P=.04) and larger preoperative tumor volumes (SHR=1.01, 95% CI 1.0-1.01, P=.006) were significantly associated with worse TC. Karnofsky performance status was the only significant predictor for OS on multivariate analysis. There were no differences in TC between patients treated with different surgical techniques or different preoperative or postoperative Bilsky grades. There were no grade 3 or higher neurologic toxicities. Conclusion: This study represents a large series of prospective data available on patients treated with SBRT in the postoperative setting. The combination of surgery with SBRT can offer patients with metastatic disease to the spine the chance of durable tumor control with minimal toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fourier analysis of continuous fractional diffusion synthetic acceleration schemes in slab geometry

We propose two fractional extensions of continuous diffusion synthetic acceleration (DSA) with fractional derivative order α varying over the interval 2 ≥ α ≥ 1 . We investigate the spectral properties of the corresponding continuous families of fractional preconditioners by performing Fourier analysis for a model infinite homogeneous medium problem in slab geometry. The first family results in a fractional acceleration scheme, FrDSAo, that reduces to traditional DSA for .α = 2 and scattering ratio c limiting to a unit value (c → 1) but is otherwise optimized via the Fourier analysis, to obtain the smallest possible spectral radius, for c < 1 and 2 ≥ α ≥ 1. The second family corresponds to a fractional acceleration scheme, FrDSAs, that reduces to traditional DSA for α = 2 for all values of c. The latter scheme is not optimized but has the advantage of lending itself to a more straightforward implementation. For high values of c, the results of the Fourier analysis point to the existence of an interval 2 > α > ∼1.8 where both FrDSAo and FrDSAs can achieve a lower spectral radius than DSA. For example, DSA has a spectral radius of ∼0.2246 for c = 0.9999 while FrDSAo produces a value of ∼0.1616 at α = 1.92 and FrDSAs results in ∼0.2116 at α =1.93. (author)

97 MATHEMATICS AND COMPUTING↗

Reducing Formation-Keeping Maneuver Costs for Formation Flying Satellites in Low-Earth Orbit

Several techniques are used to synthesize the formation-keeping control law for a three-satellite formation in low-earth orbit. The objective is to minimize maneuver cost and position tracking error. Initial reductions are found for a one-satellite case by tuning the state-weighting matrix within the linear-quadratic-Gaussian framework. Further savings come from adjusting the maneuver interval. Scenarios examined include cases with and without process noise. These results are then applied to a three-satellite formation. For both the one-satellite and three-satellite cases, increasing the maneuver interval yields a decrease in maneuver cost and an increase in position tracking error. A maneuver interval of 8-10 minutes provides a good trade-off between maneuver cost and position tracking error. An analysis of the closed-loop poles with respect to varying maneuver intervals explains the effectiveness of the chosen maneuver interval.

Hamilton, Nicholas↗

Assessment of Electrical, Electronic, and Electromechanical (EEE) Parts Copper Wire Bonds for Space Programs

The NASA Electronic Parts and Packaging Program co-manager, requested the NASA Engineering and Safety Center (NESC) to compile a body of publicly available knowledge on copper (Cu) wire bonds and perform reliability testing and analysis on these bonds, including environment tests, sample destructive physical analysis, and bond pull/shear tests during environment test intervals. The goal was to understand the risks of using Cu wire bonds for space applications and develop guidelines on Cu bond pull/shear limits for NASA applications. This document contains the results of the NESC assessment.

Electrical, Electronic, and Electromechanical↗

SPECIAL ANALYSIS AIR PATHWAY MODELING OF E-AREA LOW-LEVEL WASTE FACILITY

This Special Analysis (SA) was initiated to address a concern expressed by the Department of Energy's Low Level Waste Disposal Facility Federal Review Group (LFRG) Review Team during their review of the 2008 E-Area Performance Assessment (PA) (WSRC, 2008). Their concern was the potential for overlapping of atmospheric plumes, emanating from the soil surface above SRS LLW disposal facilities within the E-Area, to contribute to the dose received by a member of the public during the Institutional Control (IC) period. The implication of this concern was that the dose to the maximally-exposed individual (MEI) located at the SRS boundary might be underestimated during this time interval. To address this concern a re-analysis of the atmospheric pathway releases from E-Area was required. In the process of developing a new atmospheric release model (ARM) capable of addressing the LFRG plume overlap concern, it became obvious that new and better atmospheric pathway disposal limits should be developed for each of the E-Area disposal facilities using the new ARM. The scope of the SA was therefore expanded to include the generation of these new limits. The initial work conducted in this SA was to develop a new ARM using the GoldSim{reg_sign} program (GTG, 2009). The model simulates the subsurface vapor diffusion of volatile radionuclides as they release from E-Area disposal facility waste zones and migrate to the land surface. In the process of this work, many new features, including several new physical and chemical transport mechanisms, were incorporated into the model. One of the most important improvements was to incorporate a mechanism to partition volatile contaminants across the water-air interface within the partially saturated pore space of the engineered and natural materials through which vapor phase transport occurs. A second mechanism that was equally important was to incorporate a maximum concentration of 1.9E-07 Ci/m{sup 3} of {sup 14}CO{sub 2} in the air-filled pores of cementitious materials. The ARM also combines the individual transport models constructed for each E-Area disposal facility into a single model, and was ultimately used to analyze the LFRG concern regarding the potential for atmospheric plume overlap at the SRS boundary during the IC period. To evaluate the plume overlap issue, a conservative approach was adopted whereby the MEI at the SRS boundary was exposed to the releases from all E-Area disposal facilities simultaneously. This is equivalent to a 100% overlap of all atmospheric plumes emanating from E-Area. Should the dose received from this level of atmospheric plume overlap still fall below the permissible exposure level of 10 mrem/yr, then the LFRG concern would be alleviated. The structuring of the ARM enables this evaluation to be easily performed. During the IC period, the peak of the 'total plume overlap dose' was computed to be 1.9E-05 mrem/yr, which is five orders of magnitude lower than the 10 mrem/yr PA performance objective for the atmospheric release pathway. The main conclusion of this study is that for atmospheric releases from the E-Area disposal facilities, plume overlap does not cause the total dose to the MEI at the SRS boundary during the IC to exceed the Performance Assessment (PA) performance objective. Additionally, the potential for plume overlap was assessed in the post-Institutional Control period. Atmospheric plume overlap is less likely to occur during this period but conceivably could occur if the prevailing wind direction shifted so as to pass directly over all EArea disposal facilities and transport airborne radionuclides to the MEI at the 100 m point of compliance (POC). This concern was also demonstrated of little concern, as the maximum plume overlap dose was found to be 1.45E+00 mrem/yr (or {approx}15% of the performance measure) during this period and under these unlikely conditions.

54 ENVIRONMENTAL SCIENCES↗

Dose Escalation for Metastatic Spinal Cord Compression in Patients With Relatively Radioresistant Tumors

Purpose: Radiotherapy alone is the most common treatment for metastatic spinal cord compression (MSCC) from relatively radioresistant tumors such as renal cell carcinoma, colorectal cancer, and malignant melanoma. However, the results of the 'standard' regimen 30 Gy/10 fractions need to be improved with respect to functional outcome. This study investigated whether a dose escalation beyond 30 Gy can improve treatment outcomes. Methods and Materials: A total of 91 patients receiving 30 Gy/10 fractions were retrospectively compared to 115 patients receiving higher doses (37.5 Gy/15 fractions, 40 Gy/20 fractions) for motor function and local control of MSCC. Ten further potential prognostic factors were evaluated: age, gender, tumor type, performance status, number of involved vertebrae, visceral or other bone metastases, interval from tumor diagnosis to radiotherapy, pretreatment ambulatory status, and time developing motor deficits before radiotherapy. Results: Motor function improved in 18% of patients after 30 Gy and in 22% after higher doses (p = 0.81). On multivariate analysis, functional outcome was associated with visceral metastases (p = 0.030), interval from tumor diagnosis to radiotherapy (p = 0.010), and time developing motor deficits (p < 0.001). The 1-year local control rates were 76% after 30 Gy and 80% after higher doses, respectively (p = 0.64). On multivariate analysis, local control was significantly associated with visceral metastases (p = 0.029) and number of involved vertebrae (p = 0.043). Conclusions: Given the limitations of a retrospective study, escalation of the radiation dose beyond 30 Gy/10 fractions did not significantly improve motor function and local control of MSCC in patients with relatively radioresistant tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Cost-Benefit Analysis of Automated Physiological Data Acquisition Systems Using Data-Driven Modeling

Precision medicine and the continuous analysis of “Big data” promises to improve patient outcomes dramatically in the near future. Very recently, healthcare facilities have started to explore automatic collection of patient-specific physiological data with the aim of reducing nursing workload and decreasing manual data entry errors. In addition to those purposes, continuous physiological data can be used for the early detection and prevention of common, and possibly fatal, diseases. For instance, poor patient outcomes from sepsis, a leading cause of mortality in healthcare facilities and a major driver of hospital costs in the USA, can be mitigated when detected early using screening tools that monitor the changing dynamics of physiological data. However, the potential cost of collecting continuous physiological data remains a barrier to the widespread adoption of automated high-frequency data collection systems. In this paper, we perform cost-benefit analysis (CBA) of machine learning applied to various types of acquisition systems (with different collection intervals) to determine if the benefits of such systems will outweigh their implementation costs. Although such systems can be used in the detection of various complications, in order to showcase the immediate benefits, we focus on the early detection of sepsis, one of the major challenges of hospital systems. We present a general approach to conduct such analysis for a wide range of hospitals and highlight its applicability using a case study for a small hospital with 150 beds and 3000 annual patients where the acquisition system would collect data at 1-min intervals. Finally, we discuss how the analysis may help guide incentives/policies with regard to adopting automated data acquisition systems.

99 GENERAL AND MISCELLANEOUS↗