NASA NTRS · 20190025467
Dynamic Testing of a High-Specific-Torque Concentric Magnetic Gear
Abstract
This paper presents initial measurements of the efficiency of NASA's 2nd magnetic gear prototype. A detailed discussion of the test rig's design and capabilities was presented, along with a thorough uncertainty analysis. The reported uncertainties are 95% confidence intervals that include the effects of temperature and parasitic loads. The prototype's response was measured at output speeds between 124 rpm and 744 rpm for a controlled output torque of 10 Nm (8% of the prototype's maximum torque). After correcting for tare losses, the prototype's efficiency was found to decrease from 90.0% to 83.0% as speed increased. If the efficiency is extrapolated to a typical operating condition (85% of maximum torque) using the good assumption that energy loss is approximately independent of the transmitted torque, the expected efficiency would be 99.0% to 98.4%, which exceeds the state of the art for these speeds.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Scheidler, Justin J., Cameron, Zachary A., Tallerico, Thomas F.. 2019-05-13. Dynamic Testing of a High-Specific-Torque Concentric Magnetic Gear. https://ntrs.nasa.gov/citations/20190025467
Cite the original work for its findings. Save a collection to share your selection of sources.