Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Laser transport and backscatter in low-density SiO 2 and Ta2O 5 foams

Experiments using a single 527 nm wavelength beam interacting with sub- and supercritical density SiO 2 and Ta 2 O 5 foams examined laser propagation and backscatter from laser–plasma instabilities such as Stimulated Brillouin Scattering (SBS). Two densities of each material were examined, and multiple diagnostics were used to characterize the propagation and backscatter. For 5 mg/cc SiO 2 (n e /n c = 0.375), the laser propagation distance was well approximated by treating the foam as a gas. However, for the 2 mg/cc SiO 2 foam (n e /n c = 0.15), the same model over-predicts the propagation distance by ~40%. Furthermore, existing analytical theories on propagation through subcritical foams were able to account for this difference. The laser heat wave propagated ~1/2 as far in Ta 2 O 5 than SiO 2 foams with similar electron density. We showed that this difference is due to the increased radiation losses in the higher Z foam. The fraction of backscattered light scales linearly with incident laser intensity for the range of intensities examined. Ta 2 O 5 foams had significantly lower levels of backscatter (1–3%) than the SiO 2 (4–8%), which is consistent with estimates of large Landau damping due to the presence of the oxygen atoms. The measured fraction of SBS backscattered laser energy for a 2 mg/cc SiO 2 foam shot was ~4 times lower than predicted by simulations assuming a gas-like foam. We found that we needed to assume increased ion heating such that T i /T e ~1.2–1.5 in the plasma to agree with the measured SBS reflectivity. Analytical models of laser-heated foams predict preferential heating of the ions as has been observed in previous experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optically Excited Lasing in a Cavity‐Based, High‐Current‐Density Quantum Dot Electroluminescent Device

Abstract Laser diodes based on solution‐processable materials can benefit numerous technologies including integrated electronics and photonics, telecommunications, and medical diagnostics. An attractive system for implementing these devices is colloidal semiconductor quantum dots (QDs). The progress towards a QD laser diode has been hampered by rapid nonradiative Auger decay of optical‐gain‐active multicarrier states, fast device degradation at high current densities required for laser action, and unfavorable competition between optical gain and optical losses in a multicomponent device stack. Here we resolve some of these challenges and demonstrate optically excited lasing from fully functional high‐current density electroluminescent (EL) devices with an integrated optical resonator. This advance has become possible due to excellent optical gain properties of continuously graded QDs and a refined device architecture, which allows for highly efficient light amplification in a thin, EL‐active QD layer.

36 MATERIALS SCIENCE↗

Implementation of a 1550-nm laser system for beam characterization at the Argonne Wakefield Accelerator

Accurately recording an electron bunch’s longitudinal profile is an important diagnostic for wakefield accelerators employing shaped bunches to increase transformer ratios. Electro-optic sampling of terahertz radiation from the bunch is an attractive approach due to its non-destructive nature. In preparation for future characterization experiments, the Argonne Wakefield Accelerator test facility has recently installed a 1550 nm laser system, including the necessary support systems to synchronize with the photoinjector laser system at 81.25 MHz. We report here on the initial installation and synchronization demonstrations.

Ody, Alexander [Argonne, PHY]↗

Characterization and automated optimization of laser-driven proton beams from converging liquid sheet jet targets

Compact, stable, and versatile laser-driven ion sources hold great promise for applications ranging from medicine to materials science and fundamental physics. While single-shot sources have demonstrated favorable beam properties, including the peak fluxes necessary for several applications, high-repetition-rate operation will be necessary to generate and sustain the high average flux needed for many of the most exciting applications of laser-driven ion sources. Further, to navigate through the high-dimensional space of laser and target parameters toward experimental optima, it is essential to develop ion acceleration platforms compatible with machine learning techniques and capable of autonomous real-time optimization. Here, we present a multi-Hz ion acceleration platform employing a liquid sheet jet target. We characterize the laser-plasma interaction and the laser-driven proton beam across a variety of key parameters governing the interaction using an extensive suite of online diagnostics. We also demonstrate real-time, closed-loop optimization of the ion beam maximum energy by tuning the laser wave front using a Bayesian optimization scheme. This approach increased the maximum proton energy by 11% compared to a manually optimized wave front by enhancing the energy concentration within the laser focal spot, demonstrating the potential for closed-loop optimization schemes to tune future ion accelerators for robust high-repetition-rate operation.

Glenn, G. D. [SLAC National Accelerator Laboratory↗

First observation of increased DT yield over prediction due to addition of hydrogen

Here, in a number of reported instances, implosions utilizing fuel mixtures have resulted in anomalously low fusion yields below those predicted by radiation-hydrodynamics simulations. Inter-species ion diffusion has been suggested as a possible cause of the observed yield degradation in fuel mixture implosions. An experimental platform utilizing hydro-equivalent deuterium–tritium (DT), deuterium–tritium–hydrogen (DTH), and deuterium-tritium-helium3 (DT 3 He) capsule implosions was developed to determine whether the inter-species ion diffusion theory may describe the resulting fuel mixture implosion behavior. The implosion experiments were performed at the Omega laser facility. X-ray images and shell areal density diagnostics results show that the hydro-equivalent three capsules (DT, DTH, and DT 3 He) have similar compression behavior. However, nuclear yield deviation was observed from the scaling determined using a fusion yield formula. In the DT 3 He mixture, a reduced yield of a factor of 0.65 ± 0.13 was observed, which is similar to a yield reduction observed in D 3 He mixture by Rygg et al. (i.e., Rygg effect). In contrast, in the DTH mixture, a factor of 1.17 ±0.15 yield increase was observed, which we named the inverse Rygg effect. The yield increase observed in the DTH mixture is consistent with the inter-species ion diffusion theory where lighter H diffuses away from the core and concentrated DT in the core produces higher yield. An inter-species ion diffusion model, the Zimmerman–Paquette–Kagan–Zhdanov model, implemented in a Lagrangian radiation-hydrodynamics fluid code, was also used to analyze the present data, without the need to assume hydrodynamic equivalence of the capsules, but it does not completely explain the DTH or DT 3 He capsules although its effects are in the correct direction. Simulation-based Bayesian inference was used in the latter analysis to quantify the uncertainty in the numerical simulations. The simulation-based analysis resulted in an inferred Rygg-effect yield decrease factor of 0.91 ± 0.02 for the DT 3 He mixture, and an inferred inverse-Rygg yield increase factor of 1.21 ± 0.04 for the DTH mixture, based on simulations ignoring ion diffusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emission phases of implosion sources for x-ray absorption fine structure spectroscopy

At the Laboratory for Laser Energetics' Omega Laser Facility, thin plastic shells were directly driven with ∼20 kJ resulting in a time-integrated x-ray yield of ∼1012 ph/eV/sr at 7 keV. Using temporally, spatially, and spectrally discriminating diagnostics, three x-ray emission phases were identified: corona emission produced by the laser ablation of the shell, core stagnation, and afterglow emission due to the expanding hot material after stagnation. The newly measured corona and afterglow emission phases account for ∼25% of the total x-ray signal and produce x-ray emission at a different time or larger radius than previously considered. The resulting implications of this additional emission for x-ray absorption fine structure spectroscopy are discussed. Finally, improvements to the laser drive intensity and uniformity produced a factor-of-2 increase in total x-ray emission while decreasing the size of the stagnated core.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

$Z$-Pinch Interferometry Analysis With the Fourier-Based TNT Code

Here, we present the analysis of interferometry diagnostics with the user-friendly Talbot Numerical Tool (TNT), a Fourier-based postprocessing code that enables real-time assessment of plasma systems. TNT performance was explored with visible and infrared interferometry in pulsed-power-driven Z -pinch configurations to expand its capabilities beyond Talbot X-ray interferometry in the high-intensity laser environment. TNT enabled accurate electron density characterization of magnetically driven plasma flows and shocks through phase-retrieval methods that did not require data modification or masking. TNT demonstrated enhanced resolution, detecting below 4 % fringe shift, which corresponds to 8.7 × 10 15 cm –2 within 28 μ m, approaching the laser probing system limit. TNT was tested against a well-known interferometry analysis software, delivering an average resolving power nearly ten times better (~28 μ m versus ~ 210 μ m) when resolving plasma ablation features. TNT demonstrated higher sensitivity when probing sharp electron density gradients in supersonic shocks. A maximum electron areal density of 4.1 × 10 17 cm –2 was measured in the shocked plasma region, and a minimum electron density detection of ~ 1.0 × 10 15 cm –2 was achieved. When probing colliding plasma flows, the calculations of the effective adiabatic index and the associated errors were improved from γ* = 2.6 ± 1.6 – 1.4 ± 0.2 with TNT postprocessing, contributing valuable data for the interpretation of radiative transport. Additional applications of TNT in the characterization of pulsed-power plasmas and beyond are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser intensity scaling of the magnetic field from a laser-driven coil target

In this paper, we report on the first direct voltage and current measurements from a laser-generated magnetic field coil target. The magnetic field was observed to scale with the laser intensity as $B ∝ \mathcal{I}^{0.66±0.13}_\text{laser}$. This scaling relation can be derived from the measured voltage approximated by the laser-heated plasma electron temperature $T_e$. The experiments used a 1053 nm laser with pulse lengths ranging from 0.5 to 20 ns and intensities ranging from 10 9 to 10 14 W/cm 2 to generate an electric potential that drives current through the coil. We show that the behavior of the coil can be described with a lumped-element circuit model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fiber-coupled dispersion interferometer for density measurements of pulsed power transmission line electron sheaths on Sandia’s Z machine

A fiber-coupled Dispersion Interferometer (DI) is being developed to measure the electron density of plasmas formed in power flow regions, such as magnetically insulated transmission lines, on Sandia National Laboratories (SNL’s) Z machine [D. B. Sinars et al., Phys. Plasmas 27, 070501 (2020)]. The diagnostic operates using a fiber-coupled 1550 nm CW laser with frequency-doubling to 775 nm. The DI is expected to be capable of line-average density measurements between ∼1013 and 1019 cm−2. Initial testing has been performed on a well-characterized RF lab plasma [A. G. Lynn et al., Rev. Sci. Instrum. 80, 103501 (2009)] at the University of New Mexico to quantify the density resolution lower limits of the DI. Initial testing of the DI has demonstrated line-average electron density measurements within 9% of results acquired via a 94 GHz mm wave interferometer for line densities of ∼1 × 1014 cm−2, despite significant differences in probe beam geometries. The instrument will next be utilized for measurements on a ∼1 MA-scale pulsed power driver {MYKONOS [N. Bennett et al., Phys. Rev. Accel. Beams 22, 120401 (2019)] at SNL} before finally being deployed on SNL’s Z machine. The close electrode spacing (mm scale) on Z requires probe beam sizes of ∼1 mm, which can only be obtained with visible or near infrared optical systems, as opposed to longer wavelength mm wave systems that would normally be chosen for this range of density.

Hines, N. R. (ORCID:0000000315316465)↗

Radiative cooling effects on reverse shocks formed by magnetized supersonic plasma flows

We study the structure of reverse shocks formed by the collision of supersonic, magnetized plasma flows driven by an inverse (or exploding) wire array with a planar conducting obstacle. We observe that the structure of these reverse shocks varies dramatically with wire material, despite the similar upstream flow velocities and mass densities. For aluminum wire arrays, the shock is sharp and well-defined, consistent with magneto-hydrodynamic theory. In contrast, we do not observe a well-defined shock using tungsten wires, and instead we see a broad region dominated by density fluctuations on a wide range of spatial scales. We diagnose these two very different interactions using interferometry, Thomson scattering, shadowgraphy, and a newly developed imaging refractometer that is sensitive to small deflections of the probing laser corresponding to small-scale density perturbations. We conclude that the differences in shock structure are most likely due to radiative cooling instabilities, which create small-scale density perturbations elongated along magnetic field lines in the tungsten plasma. These instabilities grow more slowly and are smoothed by thermal conduction in the aluminum plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma sources for advanced semiconductor applications

Semiconductors are the foundation of modern technology, used in our personal, industrial, and military-grade devices. Further, every aspect of U.S. society is closely tied to semiconductors, and our economy cannot progress at the current pace with existing chip manufacturing methods as chip features approach an atomistic scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Static characterization of a highly optimized streak tube design incorporating a steering slot anode and an aberration-corrected Einzel lens

The BHx streak tube, under development at the Laboratory for Laser Energetics, incorporates a series of novel electron-optics elements to enable high fidelity measurements for high-energy-density physics experiments. The system is engineered to support a 25-mm active photocathode region compatible with sub-picosecond temporal resolution and with 70% internal photoelectron throughput. It exhibits negligible geometric distortion on a flat output screen, making it well suited for variety of measurements, such as ultrafast x-ray spectroscopy. Here, this paper presents characterization data from a prototype unit tested with an ultraviolet laser in a static deflection (non-swept) mode and shows good agreement with the predictions from numerical modeling, including focusing performance and geometric distortion measurements. Key design elements have been demonstrated and de-risked, laying the foundation for dynamic deflection testing. The anticipated improvements in data fidelity are expected to impact the fields as diverse as inertial confinement fusion, laboratory astrophysics, and materials science.

High energy density physics↗

Time-resolved absorption spectroscopic characterization of ultrafast laser-produced plasmas under varying background pressures

Time-resolved tunable laser absorption spectroscopy is used to characterize the physical properties of ultrafast laser-produced plasmas. The plasmas were produced from an Inconel target, with = 0.4 wt. % Al, using ~ 35 fs, ~800 nm laser pulses at varying Ar background pressures from 1-100 Torr. The absorption spectrum of atomic Al is measured with high spectral and temporal resolution when the probe laser is stepped across the selected Al transition at 394.4 nm. Spectral fitting is used to infer linewidths, kinetic temperature, Al column density, and pressure broadening coefficient. The late time physical properties of plasmas are compared for various pressure levels. Our studies highlight that a significant lower state population exists even at early times of ultrafast laser-produced plasma evolution and lower state population persistence decreases with increasing ambient pressure. We also show that the fundamental optical properties, such as pressure-broadening, can be measured using ultrafast laser-produced plasmas combined with laser absorption spectroscopy.

laser absorption spectroscopy, laser produced plas↗

Laser pulse-length dependent ablation and shock generation in silicon at 5 × 10 14 W/ cm 2 intensities

The effect of laser pulse duration on energy coupling into a planar silicon target is investigated in experiments at the OMEGA-EP facility by varying the laser pulse length τ —spanning 3 orders of magnitude from 100 ps to 10 ns—while maintaining a constant peak laser intensity, I 0 = 5 × 10 14 W/ cm 2 . In theoretical models, the ablation pressure primarily scales for a given material with laser intensity and wavelength, which are all fixed variables here, allowing us to explore the specific role of laser pulse duration. Two-dimensional radiation-hydrodynamics simulations benchmarked with optical probing of the expanding plasma show that the pulse duration is critical for the ablation pressure to reach a steady state. Moreover, the pulse duration impacts shock decay and multiple wave effects, which strongly dictate the evolving shock profile that propagates within the laser-shocked target as ultimately measured by rear-surface diagnostics. The shock velocities inferred from the theoretical model, after considering shock decay, impedance matching, and shock Hugoniot, are found to be in good agreement with velocimetry measurements. However, discrepancies are observed with simulations for the shorter (0.1 ns) and longer (10 ns) pulse durations, which are respectively attributed to unaccounted contributions of kinetic absorption mechanisms and instabilities in simulations. Published by the American Physical Society 2024

Bailly-Grandvaux, M. (ORCID:0000000175294013)↗

Time-of-flight methodologies with large-area diamond detectors for the effectively characterization of tens MeV protons

A novel detector based on a polycrystalline diamond sensor is here employed in an advanced time-of-flight scheme for the characterization of energetic ions accelerated during laser-matter interactions. The optimization of the detector and of the advanced TOF methodology allow to obtain signals characterized by high signal-to-noise ratio and high dynamic range even in the most challenging experimental environments, where the interaction of high-intensity laser pulses with matter leads to effective ion acceleration, but also to the generation of strong Electromagnetic Pulses (EMPs) with intensities up to the MV/m order. These are known to be a serious threat for the fielded diagnostic systems. Here we report on the measurement performed with the PW-class laser system Vega 3 at CLPU (~30 J energy, ~10 21 W/cm 2 intensity, ~30 fs pulses) irradiating solid targets, where both tens of MeV ions and intense EMP fields were generated. The data were analyzed to retrieve a calibrated proton spectrum and in particular we focus on the analysis of the most energetic portion (E > 5.8 MeV) of the spectrum showing a procedure to deal with the intrinsic lower sensitivity of the detector in the mentioned spectral-range.

47 OTHER INSTRUMENTATION↗

Axial proton probing of magnetic and electric fields inside laser-driven coils

In a laser-driven coil, a laser is used to eject electrons from a plate, which then draws a current through a loop. Diagnosing the field strength, geometry, and conditions within these loops has been one of the primary difficulties in fielding this type of target. In this paper, the diagnostic technique of axial proton probing with a mesh fiducial of a laser-driven coil is demonstrated. Multiple coil types were driven by a 1 ns, 1.25 kJ long pulse beam and probed several times. Here, this technique provides significantly more information than transverse probing on electric- and magnetic-field strength in the region of interest and shows in our experiment complex, non-uniform current path structures and charge distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced Laser-Induced Graphene Microfluidic Integrated Sensors (LIGMIS) for On-Site Biomedical and Environmental Monitoring

The convergence of microfluidic and electrochemical biosensor technologies offers significant potential for rapid, in-field diagnostics in biomedical and environmental applications. Traditional systems face challenges in cost, scalability, and operational complexity, especially in remote settings. Addressing these issues, laser-induced graphene microfluidic integrated sensors (LIGMIS) are presented as an innovative platform that integrates microfluidics and electrochemical sensors both comprised of laser-induced graphene. This study advances the LIGMIS concept by resolving issues of uneven fluid transport, increased hydrophobicity during storage, and sensor biofunctionalization challenges. Key innovations include Y-shaped reservoirs for consistent fluid flow, hydrophilic polyethyleneimine coatings to maintain wettability, and separable microfluidic and electrochemical components enabling isolated electrode nanoparticle metallization and biofunctionalization. Multiplexed electrochemical detection of the neonicotinoid imidacloprid and nitrate ions in environmental water samples yields detection limits of 707 nm and 10 -5.4 m with wide sensing ranges of 5–100 µm and 10 -5 –10 -1 m, respectively. Similarly, uric acid and calcium ions are detected in saliva, demonstrating detection limits of 217 nm and 10 -5.3 m with sensing ranges of 10–50 µm, and 10 -5 –10 -2.5 m, respectively. Overall, this biosensing demonstrates the capability of the LIGMIS platform for multiplexed detection in biologically complex solutions, with applications in environmental water quality monitoring and oral cancer screening.

environmental monitoring↗