Search NASA⌕ Search

SEARCH · Search NASA

Results for “object orientation algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

CDM analysis

The C Data Manager (CDM) is an advanced tool for creating an object-oriented database and for processing queries related to objects stored in that database. The CDM source code was purchased and will be modified over the course of the Arachnid project. In this report, the modified CDM is referred to as MCDM. Using MCDM, a detailed series of experiments was designed and conducted on a Sun Sparcstation. The primary results and analysis of the CDM experiment are provided in this report. The experiments involved creating the Long-form Faint Source Catalog (LFSC) database and then analyzing it with respect to following: (1) the relationships between the volume of data and the time required to create a database; (2) the storage requirements of the database files; and (3) the properties of query algorithms. The effort focused on defining, implementing, and analyzing seven experimental scenarios: (1) find all sources by right ascension--RA; (2) find all sources by declination--DEC; (3) find all sources in the right ascension interval--RA1, RA2; (4) find all sources in the declination interval--DEC1, DEC2; (5) find all sources in the rectangle defined by--RA1, RA2, DEC1, DEC2; (6) find all sources that meet certain compound conditions; and (7) analyze a variety of query algorithms. Throughout this document, the numerical results obtained from these scenarios are reported; conclusions are presented at the end of the document.

Larson, Robert E.↗

TH-AB-BRB-00: Research Opportunities with Digital Linear Accelerators

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-01: Trajectory Modulated Arc Therapy: Application to Partial Breast Irradiation

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-02: ET-Reloaded

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-03: 4n Radiotherapy

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-04: Quality Assurance for Advanced Digital Linac Implementations

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-05: Using a Research Real-Time Control Interface to Go Beyond Dynamic MLC Tracking

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

New Ways of Facilitating Improved Data Discovery and Access for NASA's Suborbital Earth Science Observations

NASA conducts field research in various Earth Science disciplines utilizing airborne and other non-satellite platforms to acquire in situ and remotely sensed observations indicative of physical processes across a range of scales. Field efforts are key in the development and validation of instruments and satellite algorithm refinements. The heterogeneous data, with a range of file formats, scales, and acquisition methods, support research in several science areas. NASA’s archive process assigns data products to discipline-oriented Distributed Active Archive Centers (DAACs) for stewardship. Over time, individual DAACs have developed tools for data browsing and serving disparate user bases. As science becomes more interdisciplinary, researchers need to incorporate observations from multiple campaigns, and multiple DAACs, into their work. Motivated in part by this shifting paradigm of needs, the Catalog of Archived Suborbital Earth Science Investigations (CASEI) was created. CASEI provides a single starting point to browse, search, and discover airborne and field data. Contextual metadata are organized and inter-linked allowing intuitive, integrated exploration across all NASA DAACs. Campaign science objectives, platform and instrument configurations, geographical details, geophysical concepts, and more are tracked in CASEI’s database, facilitating multi-parameter search, browse, and discovery of relevant data products. Researchers are able to directly access associated data products, via DOI links, regardless of the DAAC where they reside. Significant events, key time periods of high science interest within the longer-duration campaign effort, are also indicated and allow for a more efficient identification of critical data subsets. This presentation describes CASEI’s development, intensive metadata curation process, and demonstrates the web interface experience. Initial content metrics and plans for continued maintenance will also be discussed.

metadata↗

A walk through the planned CS building

Using the architectural plan views of our future computer science building as test objects, we have completed the first stage of a Building walkthrough system. The inputs to our system are AutoCAD files. An AutoCAD converter translates the geometrical information in these files into a format suitable for 3D rendering. Major model errors, such as incorrect polygon intersections and random face orientations, are detected and fixed automatically. Interactive viewing and editing tools are provided to view the results, to modify and clean the model and to change surface attributes. Our display system provides a simple-to-use user interface for interactive exploration of buildings. Using only the mouse buttons, the user can move inside and outside the building and change floors. Several viewing and rendering options are provided, such as restricting the viewing frustum, avoiding wall collisions, and selecting different rendering algorithms. A plan view of the current floor, with the position of the eye point and viewing direction on it, is displayed at all times. The scene illumination can be manipulated, by interactively controlling intensity values for 5 light sources.

Khorramabadi, Delnaz↗

Extension of an Object-Oriented Optimization Tool: User's Reference Manual

The National Aeronautics and Space Administration Armstrong Flight Research Center has developed a cost-effective and flexible object-oriented optimization (O (sup 3)) tool that leverages existing tools and practices and allows easy integration and adoption of new state-of-the-art software. This object-oriented framework can integrate the analysis codes for multiple disciplines, as opposed to relying on one code to perform analysis for all disciplines. Optimization can thus take place within each discipline module, or in a loop between the O (sup 3) tool and the discipline modules, or both. Six different sample mathematical problems are presented to demonstrate the performance of the O (sup 3) tool. Instructions for preparing input data for the O (sup 3) tool are detailed in this user's manual.

Multidisciplinary design optimization↗

Experiment in Onboard Synthetic Aperture Radar Data Processing

Single event upsets (SEUs) are a threat to any computing system running on hardware that has not been physically radiation hardened. In addition to mandating the use of performance-limited, hardened heritage equipment, prior techniques for dealing with the SEU problem often involved hardware-based error detection and correction (EDAC). With limited computing resources, software- based EDAC, or any more elaborate recovery methods, were often not feasible. Synthetic aperture radars (SARs), when operated in the space environment, are interesting due to their relevance to NASAs objectives, but problematic in the sense of producing prodigious amounts of raw data. Prior implementations of the SAR data processing algorithm have been too slow, too computationally intensive, and require too much application memory for onboard execution to be a realistic option when using the type of heritage processing technology described above. This standard C-language implementation of SAR data processing is distributed over many cores of a Tilera Multicore Processor, and employs novel Radiation Hardening by Software (RHBS) techniques designed to protect the component processes (one per core) and their shared application memory from the sort of SEUs expected in the space environment. The source code includes calls to Tilera APIs, and a specialized Tilera compiler is required to produce a Tilera executable. The compiled application reads input data describing the position and orientation of a radar platform, as well as its radar-burst data, over time and writes out processed data in a form that is useful for analysis of the radar observations.

Holland, Matthew↗

Advances in Spectral-Spatial Classification of Hyperspectral Images

Recent advances in spectral-spatial classification of hyperspectral images are presented in this paper. Several techniques are investigated for combining both spatial and spectral information. Spatial information is extracted at the object (set of pixels) level rather than at the conventional pixel level. Mathematical morphology is first used to derive the morphological profile of the image, which includes characteristics about the size, orientation and contrast of the spatial structures present in the image. Then the morphological neighborhood is defined and used to derive additional features for classification. Classification is performed with support vector machines using the available spectral information and the extracted spatial information. Spatial post-processing is next investigated to build more homogeneous and spatially consistent thematic maps. To that end, three presegmentation techniques are applied to define regions that are used to regularize the preliminary pixel-wise thematic map. Finally, a multiple classifier system is defined to produce relevant markers that are exploited to segment the hyperspectral image with the minimum spanning forest algorithm. Experimental results conducted on three real hyperspectral images with different spatial and spectral resolutions and corresponding to various contexts are presented. They highlight the importance of spectral-spatial strategies for the accurate classification of hyperspectral images and validate the proposed methods.

Fauvel, Mathieu↗

Advances in Spectral-Spatial Classification of Hyperspectral Images

Recent advances in spectral-spatial classification of hyperspectral images are presented in this paper. Several techniques are investigated for combining both spatial and spectral information. Spatial information is extracted at the object (set of pixels) level rather than at the conventional pixel level. Mathematical morphology is first used to derive the morphological profile of the image, which includes characteristics about the size, orientation, and contrast of the spatial structures present in the image. Then, the morphological neighborhood is defined and used to derive additional features for classification. Classification is performed with support vector machines (SVMs) using the available spectral information and the extracted spatial information. Spatial postprocessing is next investigated to build more homogeneous and spatially consistent thematic maps. To that end, three presegmentation techniques are applied to define regions that are used to regularize the preliminary pixel-wise thematic map. Finally, a multiple-classifier (MC) system is defined to produce relevant markers that are exploited to segment the hyperspectral image with the minimum spanning forest algorithm. Experimental results conducted on three real hyperspectral images with different spatial and spectral resolutions and corresponding to various contexts are presented. They highlight the importance of spectral–spatial strategies for the accurate classification of hyperspectral images and validate the proposed methods.

hyperspectral image↗

Julia Programming Language Benchmark Using a Flight Simulation

Julia’s goal to provide scripting language ease-of-coding with compiled language speed is explored. The runtime speed of the relatively new Julia programming language is assessed against other commonly used languages including Python, Java, and C++. An industry-standard missile and rocket simulation, coded in multiple languages, was used as a test bench for runtime speed. All language versions of the simulation, including Julia, were coded to a highly-developed object-oriented simulation architecture tailored specifically for time-domain flight simulation. A “speed-of-coding” second-dimension is plotted against runtime for each language to portray a space that characterizes Julia’s scripting language efficiencies in the context of the other languages. With caveats, Julia runtime speed was found to be in the class of compiled or semi-compiled languages. However, some factors that affect runtime speed at the cost of ease-of-coding are shown. Julia’s built-in functionality for multi-core processing is briefly examined as a means for obtaining even faster runtime speed. The major contribution of this research to the extensive language benchmarking body-of-work is comparing Julia to other mainstream languages using a complex flight simulation as opposed to benchmarking with single algorithms.

Sells, Ray↗

Multiobjective Particle Swarm Optimization for the optimal design of photovoltaic grid-connected systems

Particle Swarm Optimization (PSO) is a highly efficient evolutionary optimization algorithm. In this paper a multiobjective optimization algorithm based on PSO applied to the optimal design of photovoltaic grid-connected systems (PVGCSs) is presented. The proposed methodology intends to suggest the optimal number of system devices and the optimal PV module installation details, such that the economic and environmental benefits achieved during the system's operational lifetime period are both maximized. The objective function describing the economic benefit of the proposed optimization process is the lifetime system's total net profit which is calculated according to the method of the Net Present Value (NPV). The second objective function, which corresponds to the environmental benefit, equals to the pollutant gas emissions avoided due to the use of the PVGCS. The optimization's decision variables are the optimal number of the PV modules, the PV modules optimal tilt angle, the optimal placement of the PV modules within the available installation area and the optimal distribution of the PV modules among the DC/AC converters. (author)

14 SOLAR ENERGY↗

A new correction method serving to eliminate the parabola effect of flatbed scanners used in radiochromic film dosimetry

Purpose: The purpose of this study is the correction of the lateral scanner artifact, i.e., the effect that, on a large homogeneously exposed EBT3 film, a flatbed scanner measures different optical densities at different positions along thex axis, the axis parallel to the elongated light source. At constant dose, the measured optical densitiy profiles along this axis have a parabolic shape with significant dose dependent curvature. Therefore, the effect is shortly called the parabola effect. The objective of the algorithm developed in this study is to correct for the parabola effect. Any optical density measured at given position x is transformed into the equivalent optical density c at the apex of the parabola and then converted into the corresponding dose via the calibration of c versus dose. Methods: For the present study EBT3 films and an Epson 10000XL scanner including transparency unit were used for the analysis of the parabola effect. The films were irradiated with 6 MV photons from an Elekta Synergy accelerator in a RW3 slab phantom. In order to quantify the effect, ten film pieces with doses graded from 0 to 20.9 Gy were sequentially scanned at eight positions along thex axis and at six positions along the z axis (the movement direction of the light source) both for the portrait and landscape film orientations. In order to test the effectiveness of the new correction algorithm, the dose profiles of an open square field and an IMRT plan were measured by EBT3 films and compared with ionization chamber and ionization chamber array measurement. Results: The parabola effect has been numerically studied over the whole measuring field of the Epson 10000XL scanner for doses up to 20.9 Gy and for both film orientations. The presented algorithm transforms any optical density at positionx into the equivalent optical density that would be measured at the same dose at the apex of the parabola. This correction method has been validated up to doses of 5.2 Gy all over the scanner bed with 2D dose distributions of an open square photon field and an IMRT distribution. Conclusions: The algorithm presented in this study quantifies and corrects the parabola effect of EBT3 films scanned in commonly used commercial flatbed scanners at doses up to 5.2 Gy. It is easy to implement, and no additional work steps are necessary in daily routine film dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integrated Simulation of Weld Residual Stress Evolution and Crack Propagation Using XFEM

Nuclear power plant components operate in environments that promote multiple degradation mecha- nisms, several of which involve crack initiation and growth. An ongoing effort in the U.S. Department of Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program is developing a general capability within the Multiphysics Object Oriented Simulation Environment (MOOSE) framework for simulating three-dimensional crack growth under a range of driving conditions, including fatigue, stress corrosion cracking (SCC), brittle fracture, and stress-relaxation cracking. This report demonstrates an end-to-end workflow that uses this capability to model weld-residual-stress-driven SCC in the J-groove weld of a pressurized-water reactor control rod drive mechanism penetration in the vessel head. The workflow consists of a thermomechanical welding simulation with temperature-dependent plasticity, followed by cooldown to ambient conditions, and a restart of the simulation using the MOOSE extended finite element method (XFEM) module to propagate a three-dimensional crack through the residual stress field. New welding capabilities were developed to properly initialize newly activated elements in the weld region, and robustness improvements were made to the mesh-based algorithm for defining cutting planes in the 3D XFEM algorithm, allowing it to handle complex crack fronts and stress fields. Together these advances allowed the simulated SCC crack to grow from an initial elliptical flaw in the weld, across the weld, through the tube wall, and almost to the triple point (where the weld, tube, and reactor pressure vessel head intersect) over roughly 36 years of simulated service. These results demonstrate a workflow that can be extended to fully three-dimensional welding simulations and more complex crack interaction problems.

42 - ENGINEERING↗

Electron Tomography: Seeing Atoms in Three Dimensions

Our eyes - a parallel lens system - have the phenomenal ability to observe and "reconstruct" the three-dimensional world, relaying a 3-D image to our brains. Imaging of the nanoworld is best done with electrons rather than photons because of their lower wavelengths and higher resolution. The advent of aberration-correction has led to transmission electron microscopes with sub-Angstrom resolution that can resolve single atoms. Yet, no matter what detector is used, the resulting images are only two-dimensional projections of three-dimensional objects. Electron tomography is a technique that allows reconstruction of the three-dimensional structure and morphology of nanomaterials from such projections. X-ray tomography has been used in many branches of science for nearly half a century, and in the biological sciences electron tomography has been a powerful tool for understanding ultrastructure. However, for many years crystalline materials posed a challenge to electron tomography because diffraction contrast (a change in intensity in the image at particular crystal orientations) creates artifacts in the 3-D reconstruction. In 2003, with advances in scanning transmission electron microscopy, Midgley and colleagues obtained the first electron tomograms of crystalline materials. Shortly thereafter, Arslan et al. showed that the spatial resolution could be improved to 1 nm in all three spatial dimensions and visualized the formation of faceted 3.5-nm quantum dots embedded in a Si matrix. However, with that work existing reconstruction algorithms appeared to have reached their limit. To attain a resolution of 1 nm, a total of 140 images over ±78 degrees of tilt were needed. Writing in Nature Materials, Goris et al. now report a novel algorithm for 3-D reconstruction of the atomic structure of free-standing Au nanorods, using only four projection images. I.A. acknowledges collaboration with J.D. Roehling, K.J. Batenburg, B.C. Gates and A. Katz for Figure 1, supported in part by the DOE BES DE-SC0005822, and in part by the LDRD program at PNNL. The Pacific Northwest National Laboratory is operated by Battelle under contract DE-AC05-76RL01830.

Arslan, Ilke↗