Search NASA⌕ Search

SEARCH · Search NASA

Results for “preparation methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Preparative cell electrophoresis at 1 and 0 gravity

It is attempted to show that the use of heavy water (D2O) as starting cushion for the cells combines the advantages of the required density difference, with no lasting biochemical or physiochemical influence on the cells. Phosphate buffers of low ionic strength were prepared in distilled water or heavy water. A vertical starch gel electrophoresis was used to support a cylindrical polystyrene electrophoresis tube used for lymphocyte separations, 25 cm in length and 0.75 cm I.D., prepared from a 10 ml disposable pipet. Erythrocyte separations were carried out in a jacketed rectangular plexiglas chamber. It is pointed out that the described preparative D2O gradient electrophoresis method cannot be readily used for the measurement of electrophoretic mobilities for analytical purposes. However, for the preparative separation of cells with only slightly different electrokinetic properties the method appears promising, simple, and entirely inocuous to the cells.

Van Oss, C. J.↗

The preparation of BP single crystals by high pressure flux method

Single crystals of BP, a III-V compound semiconductor, were obtained by the high pressure flux method. Cu3P and Ni12P5 powders were used as the flux, and mixed with BP powder. Two kinds of mixtures were prepared: (1) 1.8g (BP) + 35 G (Cu3P) and (2) 1.7 g (BP) + 25 g (Ni12P5). They were compressed into pellets, heated at 1300 C for 24 h in an induction furnace under a pressure of 1 MPa using Ar-P2 gas, and slowly cooled to room temperature. In case (1), BP single crystals grew along the (III) plane, and in case (2) they grew as an aggregate of crystallites. The cathodoluminescence spectra of the synthetic BP crystals showed peaks near 680 nm (1.82 eV) for case (1), and 500 nm (2.47 eV) for case (2). By using the high pressure flux method conventional sized crystals were obtained in a relatively short time.

Kumashiro, Y.↗

Hydrocarbon polymeric binder for advanced solid propellant

A series of DEAB initiated isoprene polymerizations were run in the 5-gallon stirred autoclave reactor. Polymerization run parameters such as initiator concentration and feed rate were correlated with the molecular weight to provide a basis for molecular weight control in future runs. Synthetic methods were developed for the preparation of n-1,3-alkadienes. By these methods, 1,3-nonadiene was polymerized using DEAB initiator to give an ester-telechelic polynonadiene. This was subsequently hydrogenated with copper chromite catalyst to give a hydroxyl terminated saturated liquid hydrocarbon prepolymer having greatly improved viscosity characteristics and a Tg 18 degrees lower than that of the hydrogenated polyisoprenes. The hydroxyl-telechelic saturated polymers prepared by the hydrogenolysis of ester-telechelic polyisoprene were reached with diisocyanates under conditions favoring linear chain extension gel permeation chromatography was used to monitor this condensation polymerization. Fractions having molecular weights above one million were produced.

Potts, J. E.↗

Quantitating Iron in Serum Ferritin by Use of ICP-MS

A laboratory method has been devised to enable measurement of the concentration of iron bound in ferritin from small samples of blood (serum). Derived partly from a prior method that depends on large samples of blood, this method involves the use of an inductively-coupled-plasma mass spectrometer (ICP-MS). Ferritin is a complex of iron with the protein apoferritin. Heretofore, measurements of the concentration of serum ferritin (as distinguished from direct measurements of the concentration of iron in serum ferritin) have been used to assess iron stores in humans. Low levels of serum ferritin could indicate the first stage of iron depletion. High levels of serum ferritin could indicate high levels of iron (for example, in connection with hereditary hemochromatosis an iron-overload illness that is characterized by progressive organ damage and can be fatal). However, the picture is complicated: A high level of serum ferritin could also indicate stress and/or inflammation instead of (or in addition to) iron overload, and low serum iron concentration could indicate inflammation rather than iron deficiency. Only when concentrations of both serum iron and serum ferritin increase and decrease together can the patient s iron status be assessed accurately. Hence, in enabling accurate measurement of the iron content of serum ferritin, the present method can improve the diagnosis of the patient s iron status. The prior method of measuring the concentration of iron involves the use of an atomic-absorption spectrophotometer with a graphite furnace. The present method incorporates a modified version of the sample- preparation process of the prior method. First, ferritin is isolated; more specifically, it is immobilized by immunoprecipitation with rabbit antihuman polyclonal antibody bound to agarose beads. The ferritin is then separated from other iron-containing proteins and free iron by a series of centrifugation and wash steps. Next, the ferritin is digested with nitric acid to extract its iron content. Finally, a micronebulizer is used to inject the sample of the product of the digestion into the ICPMS for analysis of its iron content. The sensitivity of the ICP-MS is high enough to enable it to characterize samples smaller than those required in the prior method (samples can be 0.15 to 0.60 mL).

Smith, Scott M.↗

Preparation of alkali metal dispersions

A method is described for producing alkali metal dispersions of high purity. The dispersions are prepared by varying the equilibrium solubility of the alkali metal in a suitable organic solvent in the presence of aromatic hydrocarbons. The equilibrium variation is produced by temperature change. The size of the particles is controlled by controlling the rate of temperature change.

Rembaum, A.↗

Minor surgery in microgravity

The purpose is to investigate and demonstrate equipment and techniques proposed for minor surgery on Space Station Freedom (SSF). The objectives are: (1) to test and evaluate methods of surgical instrument packaging and deployment; (2) to test and evaluate methods of surgical site preparation and draping; (3) to evaluate techniques of sterile procedure and maintaining sterile field; (4) to evaluate methods of trash management during medical/surgical procedures; and (4) to gain experience in techniques for performing surgery in microgravity. A KC-135 parabolic flight test was performed on March 30, 1990 with the goal of investigating and demonstrating surgical equipment and techniques under consideration for use on SSF. The flight followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola.

Billica, Roger↗

Calibration of EcoBadge Test-Strips for Ozone Measurement for GLOBE

The majority of our work, therefore, centered on experiments at an extended exposure period at low ozone concentrations, creating and programming the necessary calibration curve into a Zikua reader. and verifying that the Zikua would use the curve reliably. Zikua is a device supplied by Vistanomics to 'read' the exposed EcoBadge cards and provide a read-out of measured ozone concentration in ppb. This device replaces the visual comparison to a calibrated color chart. For our initial studies, test papers were prepared by the usual method in small batches. Although testing would also eventually include Vistanomics' EcoBadge papers, we began with papers prepared in our lab so that we could be assured of the freshness of each batch. We felt this would allow us better comparison among our runs as we varied exposure time. At the outset, our target acceptable error was about +/- 10%. For example, if the actual ozone concentration was 20 ppb, then we hoped to be in the range 18-22 ppb. If the actual ozone concentration was 100 ppb. then we hoped to fall within 90-110 ppb in our measurements. Clearly a systematic error in the range of 3-4 ppb or more would significantly affect the lower exposure data.

Bush, Linda C.↗

Kevlar reinforced neoprene composites

Kevlar/neoprene composites were prepared by two techniques. One method involved the fabrication of a composite from a rubber prepreg prepared by coating Kevlar with viscous neoprene solution and then allowing the solvent to evaporate (solution impregnation technique). The second method involved heating a stack of Kevlar/neoprene sheets at a temperature sufficient to cause polymer flow (melt flow technique). There was no significant difference in the breaking strength and percent elongation for samples obtained by the two methods; however the shear strength obtained for samples fabricated by the solution impregnation technique (275 psi) was significantly higher than that found for the melt flow fabricated samples (110 psi).

Penn, B. G.↗

Cell separation in immunoaffinity partition in aqueous polymer two-phase systems

Two methods for immunoaffinity partitioning are described. One technique involves the covalent coupling of poly (ethylene glycol) (PEG) to immunoglobulin G antibody preparations. In the second method PEG-modified Protein A is used to complex with cells and unmodified antibody. The effects of PEG molecular weight, the degree of modification, and varying phase system composition on antibody activity and its affinity for the upper phase are studied. It is observed that both methods resulted in effective cell separation.

Karr, Laurel J.↗

Development of electrochemical super capacitors for EMA applications

In a NASA SBIR Phase I program (Contract No. NAS8-40119), Giner, Inc. evaluated the feasibility of fabricating an all-solid-ionomer multicell electrochemical capacitor having a unit cell capacitance greater than 2 F/sq cm and a repeating element thickness of 6 mils. This capacitor can possibly be used by NASA as a high-rate energy source for electromechanical actuator (EMA) activation for advanced space missions. The high unit cell capacitance and low repeating element thickness will allow for the fabrication of a low-volume, low-weight device, favorable characteristics for space applications. These same characteristics also make the capacitor attractive for terrestrial applications, such as load-leveling batteries or fuel cells in electric vehicle applications. Although the projected energy densities for electrochemical capacitors are about two orders of magnitude lower than that of batteries, the high-power-density characteristics of these devices render them as potentially viable candidates for meeting pulse or peak electrical power requirements for some anticipated aerospace mission scenarios, especially those with discharge times on the millisecond to second time scale. On a volumetric or gravimetric basis, the advantages of utilizing electrochemical capacitors rather than batteries for meeting the peak power demands associated with a specific mission scenario will largely depend upon the total and pulse durations of the power peaks. The effect of preparation conditions on RuO(x), the active component in an all-solid-ionomer electrochemical capacitor, was evaluated during this program. Methods were identified to prepare RuO(x) having a surface areagreater than 180 sq m/g, and a capacitance of greater than 2 F/sq cm. Further efforts to reproducibly obtain these high-surface-area materials in scaled-up batches will be evaluated in Phase 2. During this Phase 1 program we identified a superior Nafion 105 membrane, having a film thickness of 5 mils, that showed excellent performance in our all-solid-ionomer capacitors and resulted in electrochemical capacitors with a repeating element thickness of 8 mils. We are currently working with membrane manufacturers to obtain a high performance membrane in less than 3 mil thickness to obtain a repeating element thickness of 6 mils or less. A 10-cell all-solid ionomer capacitor stack, with each cell having a 222 sq cm active area, was fabricated and evaluated as part of the Phase 1 program. Further Scale-up of a high-energy-density stack is plannedin Phase 2.

Kosek, J. A.↗

A method for calculating heat transfer in the laminar flow region of bodies

This report has been prepared to provide a practical method for determining the chordwise distribution of the rate of heat transfer from the surface of a wing or body of revolution to air. The method is limited in use to the determination of heat transfer from the forward section of such bodies when the flow is laminar. A comparison of the calculated average heat-transfer coefficient for the nose section of the wing of a Lockheed 12-A airplane with that experimentally determined shows a satisfactory agreement. A sample calculation is appended.

Allen, H Julian↗

Theoretical evaluation of high speed aerodynamics for arrow wing configurations

A limited study in the use of theoretical methods to calculate the high speed aerodynamics of arrow wing supersonic cruise configurations was conducted. The study consisted of correlations with existing wind tunnel data at Mach numbers from 0.8 to 2.7, using theoretical methods to extrapolate the wind tunnel data to full scale flight conditions, and presentation of a typical supersonic data package for an advanced supersonic transport application prepared using the theoretical methods. A brief description of the methods and their application was given. In general, all three methods had excellent correlation with wind tunnel data at supersonic speeds for drag and lift characteristics and fair to poor agreement with pitching moment characteristics. The VORLAX program had excellent correlation with wind tunnel data at subsonic speeds for lift and pitching moment characteristics and fair agreement in drag characteristics.

Dollyhigh, S. M.↗

Single-Step, Solvent-Free, Catalyst-Free Preparation of Holey Carbon Allotropes

Methods for forming holey carbon allotropes and graphene nanomeshes are provided by the various embodiments. The various embodiments may be applicable to a variety of carbon allotropes, such as graphene, graphene oxide, reduced graphene oxide, thermal exfoliated graphene, graphene nanoribbons, graphite, exfoliated graphite, expanded graphite, carbon nanotubes (e.g., single-walled carbon nanotubes, double-walled carbon nanotubes, few-walled carbon nanotubes, multi-walled carbon nanotubes, etc.), carbon nanofibers, carbon fibers, carbon black, amorphous carbon, fullerenes, etc. The methods may produce holey carbon allotropes without the use of solvents, catalysts, flammable gas, additional chemical agents, or electrolysis to produce the pores (e.g., holes, etc.) in the carbon allotropes. In an embodiment, a carbon allotrope may be heated at a working window temperature for a working period of time to create holes in the carbon allotrope.

Lin, Yi↗

Characterisation of frequency doubling in Eu(2+) doped aluminosilicate fibres

The results of a series of experiments on efficient second-harmonic generation in a fiber with a Eu(2+)-doped aluminosilicate core are reported. The fiber was prepared by the seeding method with CW mode-locked radiation at 1.06 micron and produced ultrastable peak conversion efficiencies of 0.001 during mode-locked readout. Experiments were performed to determine the IR preparation intensity dependence, the stability of the output, and the type of erasure mechanisms which occur. The results are compared with those of germanosilicate fibers and some similarities and differences are discussed.

Driscoll, T. J.↗

An Advanced Approach to Simultaneous Monitoring of Multiple Bacteria in Space

This interim report describes progress on the development of spacecraft-compatible methods of nucleic acid preparation and cleanup. Grantee found that performance of a widely-known protocol could be greatly enhanced by the addition of a sizing step to eliminate acids. Testing of alternative adsorptive methods is underway. Grantee also confirmed and extended observation of precipitation of DNA by condensing agents such a spermine at low ionic strength.

Eggers, Mitch↗

Transmission Electron Microscopy (TEM) Sample Preparation of Si(1-x)Gex in c-Plane Sapphire Substrate

The National Aeronautics and Space Administration-invented X-ray diffraction (XRD) methods, including the total defect density measurement method and the spatial wafer mapping method, have confirmed super hetero epitaxy growth for rhombohedral single crystalline silicon germanium (Si1-xGex) on a c-plane sapphire substrate. However, the XRD method cannot observe the surface morphology or roughness because of the method s limited resolution. Therefore the authors used transmission electron microscopy (TEM) with samples prepared in two ways, the focused ion beam (FIB) method and the tripod method to study the structure between Si1-xGex and sapphire substrate and Si1?xGex itself. The sample preparation for TEM should be as fast as possible so that the sample should contain few or no artifacts induced by the preparation. The standard sample preparation method of mechanical polishing often requires a relatively long ion milling time (several hours), which increases the probability of inducing defects into the sample. The TEM sampling of the Si1-xGex on sapphire is also difficult because of the sapphire s high hardness and mechanical instability. The FIB method and the tripod method eliminate both problems when performing a cross-section TEM sampling of Si1-xGex on c-plane sapphire, which shows the surface morphology, the interface between film and substrate, and the crystal structure of the film. This paper explains the FIB sampling method and the tripod sampling method, and why sampling Si1-xGex, on a sapphire substrate with TEM, is necessary.

Kim, Hyun Jung↗

Progress Toward Efficient Laminar Flow Analysis and Design

A multi-fidelity system of computer codes for the analysis and design of vehicles having extensive areas of laminar flow is under development at the NASA Langley Research Center. The overall approach consists of the loose coupling of a flow solver, a transition prediction method and a design module using shell scripts, along with interface modules to prepare the input for each method. This approach allows the user to select the flow solver and transition prediction module, as well as run mode for each code, based on the fidelity most compatible with the problem and available resources. The design module can be any method that designs to a specified target pressure distribution. In addition to the interface modules, two new components have been developed: 1) an efficient, empirical transition prediction module (MATTC) that provides n-factor growth distributions without requiring boundary layer information; and 2) an automated target pressure generation code (ATPG) that develops a target pressure distribution that meets a variety of flow and geometry constraints. The ATPG code also includes empirical estimates of several drag components to allow the optimization of the target pressure distribution. The current system has been developed for the design of subsonic and transonic airfoils and wings, but may be extendable to other speed ranges and components. Several analysis and design examples are included to demonstrate the current capabilities of the system.

Campbell, Richard L.↗