Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Containerless low gravity processing of glass forming and immiscible alloys

Under normal one-g conditions immiscible alloys segregate extensively during solidification due to sedimentation of the more dense of the immiscible liquid phases. Immiscible (hypermonotectic) gold-rhodium alloys were processed in the 100 meter drop tube under low gravity, containerless conditions to determine the feasibility of producing dispersed structures. Three alloy compositions were utilized. Alloys containing 10 percent by volume of the gold-rich hypermonotectic phase exhibited a tendency for the gold-rich liquid to wet the outer surface of the samples. This wetting tendency led to extensive segregation in several cases. Alloys containing 80 and 90 percent by volume of the gold-rich phase possessed completely different microstructures from the 10 percent samples when processed under low-g, containerless conditions. Several samples exhibited microstructures consisting of well dispersed 2 to 3 microns diameter rhodium-rich spheres in a gold-rich matrix.

Andrews, J. Barry↗

Study of sample drilling techniques for Mars sample return missions

To demonstrate the feasibility of acquiring various surface samples for a Mars sample return mission the following tasks were performed: (1) design of a Mars rover-mounted drill system capable of acquiring crystalline rock cores; prediction of performance, mass, and power requirements for various size systems, and the generation of engineering drawings; (2) performance of simulated permafrost coring tests using a residual Apollo lunar surface drill, (3) design of a rock breaker system which can be used to produce small samples of rock chips from rocks which are too large to return to Earth, but too small to be cored with the Rover-mounted drill; (4)design of sample containers for the selected regolith cores, rock cores, and small particulate or rock samples; and (5) design of sample handling and transfer techniques which will be required through all phase of sample acquisition, processing, and stowage on-board the Earth return vehicle. A preliminary design of a light-weight Rover-mounted sampling scoop was also developed.

Mitchell, D. C.↗

Apollo Next Generation Sample Analysis (ANGSA): A Segue to the Next Era of Lunar Exploration and Sample Return Activities

In the fifty years since the first lunar samples were collected on Apollo 11, significant advancements have taken place in laboratory analysis, planetary science, and astromaterials curation. These advances are now being leveraged for the Apollo Next Generation Sample Analysis (ANGSA) Program, which aims to study specially curated Apollo samples that have never been studied before. Since Apollo 17 in 1972, a great deal has been learned about the Moon, including the unique environments of the poles. Building upon Apollo and remote sensing studies since then, the Artemis Program aims to explore the cold environments near the lunar south pole while achieving the concurrent goals of landing the first woman and the next man on the Moon by 2024. Recent developments for ANGSA have significantly accelerated our readiness for Artemis sample return, particularly in the area of cold sample studies. Four science teams were selected to study cold and/or volatile-bearing samples collected during the Apollo program. These samples have special storage and handling requirements that necessitate their processing in a -20°C environment that meets the Apollo materials and cleanliness requirements. NASA has recently undertaken the development and implementation of a cold sample processing facility to support ANGSA. A similar facility will be needed to process the cold, volatile-bearing samples planned to be returned by Artemis missions; therefore, ANGSA provides excellent preparation for Artemis’ future cold sample processing efforts. We will outline the goals of the ANGSA and Artemis programs, illustrating the complementary nature of the work for both. We will describe the efforts to date in designing, testing, and implementing a cold curation facility that meets the requirements of ANGSA and Apollo curation. We will then outline future work for that facility to reach operational readiness. Finally, we will present the sample collection and curation strategies for Artemis, showing how they overlap and build on ANGSA efforts. The development of cold curation at NASA represents a significant leap in the knowledge, experience, and technologies used in astromaterials curation, opening the door for new investigations of lunar volatiles, impacts, formation processes, prebiotic chemistry, and resource utilization, among many others.

Julie Mitchell↗

Pioneer Venus Orbiter Electron Temperature Probe

The Orbiter Electron Temperature Probe (OETP) instrumentation and measurement technique has been designed to perform in-situ measurements of electron temperature and electron and ion density in the ionosphere of Venus. Adaptive sweep voltage circuitry continuously tracks the changing electron temperature and spacecraft potential while auto-ranging electrometers adjust their gain in response to the changing plasma density. Control signals used in the instrument to achieve this automatic tracking provide a continuous monitor of the ionospheric parameters without telemetering each volt-ampere curve. Internal data storage permits high data rate sampling of selected raw characteristic curves for low rate transmission to earth. These curves are used to verify or correct the inflight processed data. Sample in orbit measurements are presented to demonstrate instrument performance.

Krehbiel, J. P.↗

Hydrogen Peroxide as a Method for Bioburden Reduction in Facilities with Strict Materials Requirements.

The cleanrooms used to curate NASA’s Astromaterials samples are carefully monitored for particulate and inorganic contamination. The clean labs also have a very limited set of acceptable materials and cleaning agents to further minimize the potential for contamination. Labs are cleaned primarily with isopropyl alcohol. Astromaterials samples are handled with tools made of stainless steel (304 or 316), Teflon, or aluminum alloy (6061). Although our current collections are not particularly susceptible to biological alteration or organic contamination, this will not be the case for new collections from the OSIRIS-REx mission, Hayabusa2, and from Mars Sample Return. Therefore, it is necessary to develop and test methods to reduce the bioburden in astromaterials cleanrooms without introducing unwanted contaminants. We will report on the results of three case studies where 7.5 wt% hydrogen peroxide was prepared from a stock solution of ultrapure 30 wt% hydrogen peroxide (JT Baker) using curation-grade ultrapure water. We followed CDC (Center for Disease Control) guidelines for using hydrogen peroxide as a high level disinfectant. This solution was used to clean a glovebox prior to processing Apollo samples, as well as surfaces in the Antarctic meteorite processing lab and Stardust lab after facilities monitoring indicated an unwanted increase in bioburden. In all three instances, the culturable bioburden was significantly reduced after a 30 min. exposure to the 7.5% hydrogen peroxide solution without a corresponding increase in inorganic or organic contamination. We observed 77 to 100% reductions in the bioburden recovery rate. In one case study, we also performed amplicon DNA sequencing on samples collected from the surfaces before and after cleaning. We observed a significant change in microbial community composition after peroxide cleaning. These results suggest that routine cleaning with hydrogen peroxide could be an effective way to control bioburden in astromaterials cleanrooms and other facilities with strict contamination control requirements.

A B Regberg↗

Hydrogen Peroxide as a Method for Bioburden Reduction in Facilities with Strict Materials Requirements

The cleanrooms used to curate NASA’s Astromaterials samples are carefully monitored for particulate and inorganic contamination. The clean labs also have a very limited set of acceptable materials and cleaning agents to further minimize the potential for contamination. Labs are cleaned primarily with isopropyl alcohol. Astromaterials samples are handled with tools made of stainless steel (304 or 316), Teflon, or aluminum alloy (6061). Although our current collections are not particularly susceptible to biological alteration or organic contamination, this will not be the case for new collections from the OSIRIS-REx mission, Hayabusa2, and from Mars Sample Return. Therefore, it is necessary to develop and test methods to reduce the bioburden in astromaterials cleanrooms without introducing unwanted contaminants. We will report on the results of three case studies where 7.5 wt% hydrogen peroxide was prepared from a stock solution of ultrapure 30 wt% hydrogen peroxide (JT Baker) using curation-grade ultrapure water. We followed CDC (Center for Disease Control) guidelines for using hydrogen peroxide as a high level disinfectant. This solution was used to clean a glovebox prior to processing Apollo samples, as well as surfaces in the Antarctic meteorite processing lab and Stardust lab after facilities monitoring indicated an unwanted increase in bioburden. In all three instances, the culturable bioburden was significantly reduced after a 30 min. exposure to the 7.5% hydrogen peroxide solution without a corresponding increase in inorganic or organic contamination. We observed 77 to 100% reductions in the bioburden recovery rate. In one case study, we also performed amplicon DNA sequencing on samples collected from the surfaces before and after cleaning. We observed a significant change in microbial community composition after peroxide cleaning. These results suggest that routine cleaning with hydrogen peroxide could be an effective way to control bioburden in astromaterials cleanrooms and other facilities with strict contamination control requirements.

A B Regberg↗

Design and Fabrication Highlights Enabling a 2 mm, 128 Element Bolometer Array for GISMO

The Backshort-Under-Grid (BUG) superconducting bolometer array architecture is intended to be highly versatile, operating in a large range of wavelengths and background conditions. We have undertaken a three-year program to develop key technologies and processes required to build kilopixel arrays. To validate the basic array design and to demonstrate its applicability for future kilopixel arrays, we have chosen to demonstrate a 128 element bolometer array optimized for 2 mm wavelength using a newly built Goddard instrument, GISMO (Goddard /RAM Superconducting 2-millimeter Observer). The arrays are fabricated using batch wafer processing developed and optimized for high pixel yield, low noise, and high uniformity. The molybdenum-gold superconducting transition edge sensors are fabricated using batch sputter deposition and are patterned using dry etch techniques developed at Goddard. With a detector pitch of 2 mm 8x16 array for GISMO occupies nearly one half of the processing area of a 100 mm silicon-on-insulator starting wafer. Two such arrays are produced from a single wafer along with witness samples for process characterization. To provide thermal isolation for the detector elements, at the end of the process over 90% of the silicon must be removed using deep reactive ion etching techniques. The electrical connections for each bolometer element are patterned on the top edge of the square grid supporting the array. The design considerations unique to GISMO, key fabrication challenges, and laboratory experimental results will be presented.

Allen, Christine↗

Oxygen and Magnesium Isotopic Compositions of Asteroidal Materials Returned from Itokawa by the Hayabusa Mission

The Hayabusa spacecraft made two touchdowns on the surface of Asteroid 25143 Itokawa on November 20th and 26th, 2005. The Asteroid 25143 Itokawa is classified as an S-type asteroid and inferred to consist of materials similar to ordinary chondrites or primitive achondrites [1]. Near-infrared spectroscopy by the Hayabusa spacecraft proposed that the surface of this body has an olivine-rich mineral assemblage potentially similar to that of LL5 or LL6 chondrites with different degrees of space weathering [2]. The spacecraft made the reentry into the Earth s atmosphere on June 12th, 2010 and the sample capsule was successfully recovered in Australia on June 13th, 2010. Although the sample collection processes on the Itokawa surface had not been made by the designed operations, more than 1,500 grains were identified as rocky particles in the sample curation facility of JAXA, and most of them were judged to be of extraterrestrial origin, and definitely from Asteroid Itokawa on November 17th, 2010 [3]. Although their sizes are mostly less than 10 microns, some larger grains of about 100 microns or larger were also included. The mineral assembly is olivine, pyroxene, plagioclase, iron sulfide and iron metal. The mean mineral compositions are consistent with the results of near-infrared spectroscopy from Hayabusa spacecraft [2], but the variations suggest that the petrologic type may be smaller than the spectroscopic results. Several tens of grains of relatively large sizes among the 1,500 grains will be selected by the Hayabusa sample curation team for preliminary examination [4]. Each grain will be subjected to one set of preliminary examinations, i.e., micro-tomography, XRD, XRF, TEM, SEM, EPMA and SIMS in this sequence. The preliminary examination will start from the last week of January 2011. Therefore, samples for isotope analyses in this study will start from the last week of February 2011. By the time of the LPSC meeting we will have measured the oxygen and magnesium isotopic composition of several grains. We will present the first results from the isotope analyses that will have been performed.

Yurimoto, H↗

Determining Surface Exposure Ages of Regolith Grains in Lunar Core Sample 73002 By Investigating Solar Particle Irradiation Damage

Space weathering causes the surface soils of airless bodies like the Moon to be micro-structurally and chemically altered by exposure to micrometeoroid bombardment and solar wind irradiation. These alterations accumulate in surface grains with continued residence in the uppermost millimeters of regolith. Low energy solar wind ions (largely H+ and He+) produce a layer of radiation damage as they become implanted in grain surfaces. Also present are solar energetic particle (SEP) tracks, which are nanoscale lineations within grain interiors formed by heavy, high-energy ions (mainly Fe group nuclei) penetrating up to millimeters below the surface. Recent work has determined that the width of solar wind-damaged rims on anorthite and olivine, and their respective SEP track densities are correlated with each other and with grain surface exposure age. Core sample 73002, recently released under the Apollo Next Generation Sample Analysis (ANGSA) Program, has provided an opportunity to study material collected from the light mantle formation in the Taurus-Littrow Valley during Apollo 17. The light mantle is thought to have been deposited vial and slide originating from the neighboring South Massif. Spectral analysis of bulk core soils found a plagioclase rich composition, confirming a highlands origin of the formation. Spectral profiles and ferromagnetic resonance (FMR) measurements of bulk soils sampled at cm-intervals from 73002 indicate that regolith up to~9.5 cm in depth have maturity indices consistent with longer durations of surface processing than samples deeper in the core. Thus, this upper ~9 cm layer likely represents the maximum extent of an in-situ reworking zone which may have persisted over 5 to 17million years. Here we present an analysis of grain exposure ages within the in-situ reworking zone of 73002derived from SEP track density measurements via transmission electron microscopy.

J A McFadden↗

Large-cell Monte Carlo renormalization of irreversible growth processes

Monte Carlo sampling is applied to a recently formulated direct-cell renormalization method for irreversible, disorderly growth processes. Large-cell Monte Carlo renormalization is carried out for various nonequilibrium problems based on the formulation dealing with relative probabilities. Specifically, the method is demonstrated by application to the 'true' self-avoiding walk and the Eden model of growing animals for d = 2, 3, and 4 and to the invasion percolation problem for d = 2 and 3. The results are asymptotically in agreement with expectations; however, unexpected complications arise, suggesting the possibility of crossovers, and in any case, demonstrating the danger of using small cells alone, because of the very slow convergence as the cell size b is extrapolated to infinity. The difficulty of applying the present method to the diffusion-limited-aggregation model, is commented on.

Nakanishi, H.↗

Materials Processing in Space: Model Experiments aboard the International Space Station

Direct observation of fluid flow, bubble movement and solidification during controlled melting and solidification of succinonitrile were conducted in the glovebox facility of the International Space Station (ISS). The samples were processed in the Pore Formation and Mobility Investigation (PFMI) apparatus in the glovebox facility (GBX) on board the ISS. Experimental processing parameters of temperature gradient and translation speed, as well as camera settings, were remotely monitored and manipulated from the ground Telescience Center (TSC) at the Marshall Space Flight Center. Real time visualization of the controlled directional melt back and resolidification reveals a number of microgravity dependent phenomena otherwise masked by Earth s gravity. These and some initial analysis of the observed events is presented.

Grugel, Richard↗

The Fluid Processing Apparatus: from Flight Hardware to Electron Micrographs

Since the early years of space biology, a major drawback in spaceflight plant experiments has been the inability to fix specimens in microgravity, relying instead on fixation after return to Earth. As there, it is of a growing interest to look at the effect of microgravity on the structure and the developmental polarity of root graviperceptive cells, or columella cells, and so, it is important to use flight hardware which allows specimen fixation in space therefore avoiding the confounding effects of rapid readaptation to gravity after landing. As part of the Bioserve Space Technologies, a Center for the Commercial Development of Space (CCDS), we now have experiment flight opportunities through the Commercial Generic Bioprocessing Apparatus (CGBA) payload. In this study the Fluid Processing Apparatus (FPA) was used to grow seedlings for a limited period of time prior to fixation of the tissue in a microgravity environment. Upon return to Earth, the samples were processed for electron microscopy. This report describes the microscopic data obtained from the two space flights (STS-54 and STS-60). In both cases, the electron micrographs of the columella cells revealed well preserved cell structure, well defined microtubules, and the presence of calcium precipitates formed by a antimonate precipitation method.

Hilaire, Emmanuel↗

Facility Concepts for Mars Returned Sample Handling

Samples returned from Mars must be held in quarantine until their biological safety has been determined. A significant challenge, unique to NASA's needs, is how to contain the samples (to protect the blaspheme) while simultaneously protecting their pristine nature. This paper presents a comparative analysis of several quarantine facility concepts for handling and analyzing these samples. The considerations in this design analysis include: modes of manipulation; capability for destructive as well as non-destructive testing; avoidance of cross-contamination; linear versus recursive processing; and sample storage and retrieval within a closed system. The ability to rigorously contain biologically hazardous materials has been amply demonstrated by facilities that meet the specifications of the Center for Disease Control Biosafety Level 4. The newly defined Planetary Protection Level Alpha must provide comparable containment while assuring that the samples remain pristine; the latter requirement is based on the need to avoid compromising science analyses by instrumentation of the highest possible sensitivity (among other things this will assure that there is no false positive detection of organisms or organic molecules - a situation that would delay or prevent the release of the samples from quarantine). Protection of the samples against contamination by terrestrial organisms and organic molecules makes a considerable impact upon the sample handling facility. The use of glove boxes appears to be impractical because of their tendency to leak and to surges. As a result, a returned sample quarantine facility must consider the use of automation and remote manipulation to carry out the various functions of sample handling and transfer within the system. The problem of maintaining sensitive and bulky instrumentation under the constraints of simultaneous sample containment and contamination protection also places demands on the architectural configuration of the facility that houses it.

Cohen, Marc M.↗

Flow Cytometry Methods to Monitor Immune System Dysregulation in Astronauts

Persistent immune system dysregulation has been documented to occur in astronauts participating in orbital spaceflight onboard the International Space Station. The phenomenon consists of reductions in T and NK cell function, altered cytokine profiles, persistent inflammation, and the subclinical reactivation of latent herpesviruses. In select crewmembers the dysregulation does actually lead to clinical symptoms, primarily atypical allergy or atopic dermatitis/zoster. Flow cytometry has served a central role defining the ‘immune assessment’ panel of assays that allow monitoring of astronauts. The cytometry assays which have been utilized include: 1. Peripheral leukocyte subsets 2. T cell function 3. Monocyte function 4. NK cell function 5. Intracellular cytokine analysis 6. Virus-specific T cell number (tetramer assay) 7. Virus-specific T cell function (peptide stimulation) 8. Leukocyte-bacterial challenge cytometry 9. Cytometric bead/multiplex array (soluble proteins) The use of these assays has been validated through various ISS flight investigations to define, to varying degrees, both in-flight, and post-flight immune system alterations. The kinetics of the dysregulation through the various phases of spaceflight, as well as post-flight recovery, have also been documented. To allow the science to occur within the orbital constraints of a spaceflight investigation, particular sample collection and processing techniques were developed compatible with the delays associated with terrestrial processing of in-flight samples. A subset of the assays has been adapted to routine monitoring of astronauts via a NASA ‘ISS Standard Measures’ activity, with the data from a specific crew then provided to all science investigators for that particular mission. This battery of cytometry assays has also been applied, through ground investigations, to several terrestrial ‘spaceflight analog’ populations. The purpose was to validate the analog which most closely replicates the in-flight observed pattern of alterations, generally believed to be winterover at an Antarctica station. To assist in determination of clinical risk, the assay panel has also been applied to investigations of various terrestrial patient populations, particularly zoster patients. As NASA is initiating crewed lunar missions via the ‘Artemis’ program, deployment of a miniaturized, microgravity-compatible flow cytometer, would be extremely beneficial to allow real time monitoring of crewmembers. Real time medical data could influence use of several countermeasures options during deep space missions. Several such instruments have been developed and validated to varying degrees of success. Assay details and summary findings across the various flight and ground platforms will be presented, as will current status in developing such technology for in-flight use.

Brian Crucian↗

Genesis Solar Wind Sample Curation Facility

The controlled access facility designed and constructed for storing and examining Genesis solar wind samples consists of two adjacent laboratories, both ISO Class 4 cleanrooms (vertical laminar flow, ULPA filtered). One cleanroom is equipped with ultrapure water (UPW) for experimental cleaning of containers and tools used in handling the solar wind samples, flight hardware and witness plates. The ultrapure water is also used for cleaning the solar wind samples. The other cleanroom is for long-term nitrogen storage of samples and for examination and processing of Genesis samples.

Curation Facility↗

Improved Detection Technique for Solvent Rinse Cleanliness Verification

The NASA White Sands Test Facility (WSTF) has an ongoing effort to reduce or eliminate usage of cleaning solvents such as CFC-113 and its replacements. These solvents are used in the final clean and cleanliness verification processes for flight and ground support hardware, especially for oxygen systems where organic contaminants can pose an ignition hazard. For the final cleanliness verification in the standard process, the equivalent of one square foot of surface area of parts is rinsed with the solvent, and the final 100 mL of the rinse is captured. The amount of nonvolatile residue (NVR) in the solvent is determined by weight after the evaporation of the solvent. An improved process of sampling this rinse, developed at WSTF, requires evaporation of less than 2 mL of the solvent to make the cleanliness verification. Small amounts of the solvent are evaporated in a clean stainless steel cup, and the cleanliness of the stainless steel cup is measured using a commercially available surface quality monitor. The effectiveness of this new cleanliness verification technique was compared to the accepted NVR sampling procedures. Testing with known contaminants in solution, such as hydraulic fluid, fluorinated lubricants, and cutting and lubricating oils, was performed to establish a correlation between amount in solution and the process response. This report presents the approach and results and discusses the issues in establishing the surface quality monitor-based cleanliness verification.

Hornung, S. D.↗

Spectral Quantitation Of Hydroponic Nutrients

Instrument continuously monitors hydroponic solution by use of absorption and emission spectrometry to determine concentrations of principal nutrients, including nitrate, iron, potassium, calcium, magnesium, phosphorus, sodium, and others. Does not depend on extraction and processing of samples, use of such surrograte parameters as pH or electrical conductivity for control, or addition of analytical reagents to solution. Solution not chemically altered by analysis and can be returned to hydroponic process stream after analysis.

Schlager, Kenneth J.↗