Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAMS, RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Comparison of Measured and Calculated Dose Rates for Ring Injection Dump Exchange at Spallation Neutron Source

According to the accelerator operation plan, the beam-stop and the proton beam window (PBW) assemblies of the existing Ring Injection Dump RID are replaced with fresh assemblies, when they have reached their end-of-life. End of-life is determinate by the stainless-steel beam-stop window having accumulated 10 dpa radiation damage. The exchange process took place during facility maintenance period that started in March 2023. Each of the spent assembles were put into specially designed storage containers temporarily residing near the RID building.The spent beam-stop is predicted to be the part of highest activation that has been removed in Spallation Neutron Source (SNS). The exchange processes require good work planning to minimize radiation exposure to personal. For each exchange step the residual dose rate distribution is calculated and the peak values are identified. This paper gives some examples of calculated vs measured doses during beam-stop assembly exchange.

Popova, Irina I.↗

Evidence of electron microbunching in laser-driven modulated downramp injection and prospects for beam-driven implementation

Plasma accelerators can generate high-energy, high-brightness electron beams over centimeter-scale distances, offering novel pathways to compact x-ray free-electron lasers. Generating beams pre-bunched at the desired radiation wavelength would significantly enhance longitudinal coherence and reduce saturation length. Plasma density-modulated downramp injection offers an in-situ way to generate such beams with nanometer-scale bunching. Here we report the first experimental evidence of this mechanism in a laser-driven wakefield accelerator, showing that modulated density downramps generate modulated electron energy spectra absent in unmodulated cases. Particle-in-cell simulations reproduce these observations and reveal bunching factors of 0.05 at 0.4 μm, with a compression factor of approximately 7. Building on this demonstration, we propose a beam-driven implementation for FACET-II to generate multi-GeV beams pre-bunched at hundreds of nanometers wavelength, with sub-micrometer emittance, kiloampere peak current, and sub-percent slice energy spread. Two-stage magnetic compression enables tunable bunching from optical to extreme ultraviolet wavelengths while achieving peak currents exceeding 100 kA. Coherent transition radiation calculations confirm diagnostic feasibility. This approach offers a promising path towards compact, high-energy pre-bunched electron sources for advanced photon science applications.

electron microbunching↗

Generation of Terawatt Attosecond Pulses from Relativistic Transition Radiation

When a femtosecond duration and hundreds of kiloampere peak current electron beam traverses the vacuum and high-density plasma interface, a new process, that we call here relativistic transition radiation (RTR), generates an intense ~ 100 as pulse containing ~ 1 terawatt power of coherent vacuum ultraviolet (VUV) radiation accompanied by several smaller femtosecond duration satellite pulses. This pulse inherits the radial polarization of the incident beam field and has a ring intensity distribution. This RTR is emitted when the beam density is comparable to the plasma density and the spot size much larger than the plasma skin depth. Physically, it arises from the return current or backward relativistic motion of electrons starting just inside the plasma that Doppler up shifts the emitted photons. The number of RTR pulses is determined by the number of groups of plasma electrons that originate at different depths within the first plasma wake period and emit coherently before phase mixing.

43 PARTICLE ACCELERATORS↗

High Power Solid Target for Positron Source at CEBAF

The progress in the development of a polarized positron injector for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is presented. The polarized positron beam is generated by a high current polarized electron beam (>1 mA @ 120 MeV) via bremsstrahlung radiation and e+e- pair production in the tungsten target. The simulations show that using an optimized target and positron beamline, the positron injector can provide a cw positron beam with a current larger than 50 nA and a polarization as large as 60%. Injected into the North Linac of CEBAF at an energy of 123 MeV, the positron beam can reach a maximum energy of 12 GeV to perform a rich experimental program. The results of the thermal and structural FEA analysis of the heat load in the target are presented, as well as the simulation results of radiation damage in the target. The performed and planned target material fatigue and radiation damage tests are discussed. This work is supported by the U.S. DOE, Office of Science, Office of Nuclear Physics, Contract No. DE-AC05-06OR23177 and the European Union?s Horizon 2020 research and innovation program under grant agreement No. 824093.

Ushakov, Andriy↗

Numerical simulation of terahertz radiation by laser-driven plasma dipole oscillation

Laser-plasma interactions have many theoretical and technological applications. One is the use of coherently accelerated electrons to provide novel sources of THz radiation. Our research focuses on simulating the cross/self-interactions between two high intensity, ultra-short, counter propagating and detuned laser pulses and an initial neutral target for controlled ionization. Unlike our previous studies of laser-matter interaction over preformed plasma, we explore the injection and collision of laser pulses to induce background plasma driven by the self-guided laser wakefield mechanism, which is then used to perturb the plasma resulting in induced dipole oscillations leading to transverse radiation. Inducing a cylindrical spatial plasma column within the laser beam radius regime provides a stable, spatially localized plasma channel. The emitted radiation from the plasma dipole oscillation (PDO) will not be affected by surrounding plasma absorption, resulting in effective radiation distribution. Finally, results include 3D EM-PIC simulations and a comparison of the self- ionizing plasma against the preformed plasma to assess the efficiency of the mechanisms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of the beam-induced depolarization of the HJET target at the EIC

The Polarized Atomic Hydrogen Gas Jet Target (HJET) has played a central role in the absolute calibration of proton beam polarization at RHIC and is foreseen as a key component of the hadron polarimetry program at the future Electron–Ion Collider (EIC). The substantially higher beam current, reduced bunch spacing, and shorter bunch length planned for EIC operation motivate a careful reassessment of possible beam-induced depolarization of the jet target. In this paper, the depolarization of ground-state hydrogen atoms caused by the time-dependent magnetic field of the circulating polarized proton beam is quantitatively evaluated. The hydrogen atom is treated as a four-level hyperfine system in a holding magnetic field, and transitions driven by harmonic components of the bunch-induced magnetic field are analyzed using time-dependent quantum-mechanical evolution along atomic trajectories. Numerical tracking of hydrogen atoms through the beam region is performed using nominal EIC beam parameters. It is shown that, for a holding field of 120 mT (as used at RHIC), the resulting depolarization of the jet target at the EIC is negligibly small, ≲ 0.01 %, and well below the level relevant for EIC polarization accuracy requirements. The stability of this result with respect to plausible variations of the EIC proton beam parameters is also evaluated. In addition, possible effects under alternative experimental conditions are also examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on the normal conducting magnets for the Electron-Ion Collider

The electron-ion collider (EIC) at Brookhaven National Laboratory (BNL) is designed to deliver a peak luminosity of 1e+34 1/cm2 1/sec. The EIC will take advantage of the existing Relativistic Heavy Ion Collider (RHIC) facility. Two additional rings will be installed: an electron storage ring (ESR) and a rapid cycling electron synchrotron ring (RCS).This paper presents an update on the normal conducting magnet designs required for both the ESR and RCS rings. The ESR will store polarized electron beams up to 18 GeV and utilizes a triplet of dipole magnets to increase the emittance at 5 GeV and generate excess bending to create additional radiation damping to allow a larger beam-beam tune shift. The RCS will accelerate single bunches of spin-polarized electrons at various energies from 5 GeV to 18 GeV, with a ramp rate of 100 ms and 1 Hz repetition rate. Both rings require dipole, quadrupole and sextupole magnets with different specifications.

43 PARTICLE ACCELERATORS↗

Experimental demonstration of enhanced self-amplified spontaneous emission by photocathode temporal shaping and self-compression in a magnetic wiggler

In this paper we demonstrate experimentally the generation of attosecond soft X-ray free-electron laser (XFEL) pulses based on a novel approach to enhanced self-amplfied spontaneous emission. Instead of utilizing an external laser, we shape the electron beam at the cathode by laser pulse stacking. We enhance the high-current spike in the beam profile through a self-compression process which uses short-range coherent synchrotron radiation in a wiggler and a downstream magnetic chicane. The undulator taper is then matched with the energy chirp along the beam for attosecond XFEL generation. Start-to-end simulations are performed to demonstrate the proposed method. The measured spectra suggest that a ~250 as pulse duration is achieved at ~940 eV in the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron beam characterization via quantum coherent optical magnetometry

We present a quantum optics-based detection method for determining the position and current of an electron beam. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturbs the atomic spin's quantum state and causes polarization rotation of a laser resonant with an optical transition of the atoms. By measuring the polarization rotation angle across the laser beam, we recreate a 2D projection of the magnetic field and use it to determine the e-beam position, size, and total current. We tested this method for an e-beam with currents ranging from 30 to 110 μA. Our approach is insensitive to electron kinetic energy, and we confirmed that experimentally between 10 and 20 keV. In conclusion, this technique offers a unique platform for noninvasive characterization of charged particle beams used in accelerators for particle and nuclear physics research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design progress for the 22 GeV CEBAF energy upgrade

In this work we examine the progress made in the design of the proposed FFA upgrade to the Continuous Electron Beam Accelerator Facility (CEBAF). This proposed upgrade will double the number of passes through the two linacs by replacing the two highest energy arcs with new Fixed Field Alternating Gradient (FFA) arcs, roughly doubling the energy. These FFA arcs will use permanent magnets in a Halbach configuration to shape their fields. The design involves new optics for the linacs and remaining electromagnetic arcs, as well as new electromagnetic separators. These feed into the permanent magnet FFA arcs. We also report on ongoing studies of the dynamics of the beams, and an experiment to measure the effects of radiation on the permanent magnets.

Accelerator Physics↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Finding Beam Loss Locations at PIP2IT Accelerator With Oscillating Dipole Correctors

The PIP2IT accelerator was assembled in multiple stages in 2014 - 2021 to test concepts and components of the future PIP-II linac that is being constructed at Fermilab. In its final configuration, PIP2IT accelerated a 0.55 ms x 20 Hz x 2 mA H- beam to 16 MeV. To determine location of the beam loss in the accelerators low-energy part, where radiation monitors are ineffective, a method using oscillating trajectories was implemented. If the beam is scraped at an aperture limitation, moving its centroid with two dipole correctors located upstream and oscillating in sync, produces a line at the corresponding frequency in spectra of BPM sum signals downstream of the loss point. Comparison of these responses along the beam line allows to find the loss location. The paper describes the method and results of its implementation at PIP2IT.

43 PARTICLE ACCELERATORS↗

In-flight production of an isomeric beam of 16 N

In this work, an in-flight beam of 16 N was produced via the single-neutron adding ($\textit{d,p}$) reaction in inverse kinematics at the recently upgraded Argonne Tandem Linear Accelerator System (ATLAS) in-flight system. The amount of the 16 N beam which resided in its excited 0.120 MeV $J^\pi$ = 0 – isomeric state (T 1/2 ≈ 5 μs) was determined to be 40(5)% at a reaction energy of 7.9(3) MeV/$\textit{u}$, and 24(2)% at a reaction energy of 13.2(2) MeV/$\textit{u}$. The isomer measurements took place at an experimental station ≈ 30 m downstream of the production target and utilized an Al beam-stopping foil and a HPGe Clover detector. Composite 16 N beam rate determinations were made at the experimental station and the focal plane of the Argonne in-flight radioactive ion-beam separator (RAISOR) with Si ΔE-E telescopes. A Distorted Wave Born Approximation (DWBA) approach was coupled with the known spectroscopic information on 16 N in order to estimate the relative 16 N isomer yields and composite 16 N beam rates. In addition to the observed reaction-energy dependence of the isomer fraction, a large sensitivity to the angular acceptance of the recoils was also observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryo-electron tomography related radiation-damage parameters for individual-molecule 3D structure determination

To understand the dynamic structure–function relationship of soft- and biomolecules, the determination of the three-dimensional (3D) structure of each individual molecule (nonaveraged structure) in its native state is sought-after. Cryo-electron tomography (cryo-ET) is a unique tool for imaging an individual object from a series of tilted views. However, due to radiation damage from the incident electron beam, the tolerable electron dose limits image contrast and the signal-to-noise ratio (SNR) of the data, preventing the 3D structure determination of individual molecules, especially at high-resolution. Although recently developed technologies and techniques, such as the direct electron detector, phase plate, and computational algorithms, can partially improve image contrast/SNR at the same electron dose, the high-resolution structure, such as tertiary structure of individual molecules, has not yet been resolved. Here, we review the cryo-electron microscopy (cryo-EM) and cryo-ET experimental parameters to discuss how these parameters affect the extent of radiation damage. This discussion can guide us in optimizing the experimental strategy to increase the imaging dose or improve image SNR without increasing the radiation damage. With a higher dose, a higher image contrast/SNR can be achieved, which is crucial for individual-molecule 3D structure. With 3D structures determined from an ensemble of individual molecules in different conformations, the molecular mechanism through their biochemical reactions, such as self-folding or synthesis, can be elucidated in a straightforward manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Critical problems of energy frontier Muon Colliders: optics, magnets and radiation

This White Paper brings together our previous studies on a Muon Collider (MC) and presents a design concept of the 6 TeV MC optics, the superconducting (SC) magnets, and a preliminary analysis of the protection system to reduce magnet radiation loads as well as particle backgrounds in the detector. The SC magnets and detector protection considerations impose strict limitations on the lattice choice, hence the design of the collider optics, magnets and Machine Detector Interface (MDI) are closely intertwined. As a first approximation we use the Interaction Region (IR) design with beta-star=3 mm, whereas for the arcs we re-scale the arc cell design of the 3 TeV MC. Traditional cos-theta coil geometry and Nb3Sn superconductor were used to provide field maps for the analysis and optimization of the arc lattice and IR design, as well as for studies of beam dynamics and magnet protection against radiation. The stress management in the coil will be needed to avoid large degradation or even damage of the brittle SC coils. In the assumed IR designs, the dipoles close to the Interaction Point (IP) and tungsten masks in each IR (to protect magnets) help reducing background particle fluxes in the detector by a substantial factor. The tungsten nozzles in the 6 to 600 cm region from the IP, assisted by the detector solenoid field, trap most of the decay electrons created close to the IP as well as most of the incoherent electron-positron pairs generated in the IP. With sophisticated tungsten, iron, concrete and borated polyethylene shielding in the MDI region, the total reduction of background loads by more than three orders of magnitude can be achieved.

43 PARTICLE ACCELERATORS↗

Development of an x-ray radiography platform to study laser-direct-drive energy coupling at the National Ignition Facility

A platform has been developed to study laser-direct-drive energy coupling at the National Ignition Facility (NIF) using a plastic sphere target irradiated in a polar-direct-drive geometry to launch a spherically converging shock wave. To diagnose this system evolution, eight NIF laser beams are directed onto a curved Cu foil to generate Heα line emission at a photon energy of 8.4 keV. These x rays are collected by a 100-ps gated x-ray imager in the opposing port to produce temporally gated radiographs. The platform is capable of acquiring images during and after the laser drive launches the shock wave. A backlighter profile is fit to the radiographs, and the resulting transmission images are Abel inverted to infer radial density profiles of the shock front and to track its temporal evolution. Here, the measurements provide experimental shock trajectories and radial density profiles that are compared to 2D radiation-hydrodynamic simulations using cross-beam energy transfer and nonlocal heat-transport models.

47 OTHER INSTRUMENTATION↗

Measurement of the 25 Al(𝑑,𝑛)⁢ 26 Si reaction and impact on the 25 Al⁢(𝑝,𝛾)⁢ 26 Si reaction rate

The 25 Al(p,γ) 26 Si reaction plays a key role in nucleosynthesis pathways that influence the galactic abundance of 26 Al. A more precise determination of the proton strength of the lowest ℓ = 0 proton resonance in 26 Si is needed to improve reaction-rate calculations. This work measures the 25 Al(d,n) 26 Si proton-transfer reaction in inverse kinematics using a radioactive ion beam at RESOLUT, determining excitation energies and cross sections for the lowest ℓ = 0 resonance associated with the 3 + 3 state at 5.92(2) MeV. Coupled-reaction-channels calculations (FRESCO) are used to extract the ℓ = 0 spectroscopic factor and the corresponding proton width, yielding Γₚ = 2.19(45) eV and a (p,γ) resonance strength of 26(10) meV. This resonance is found to dominate the 25 Al(p,γ) 26 Si reaction rate above 0.2 GK.

20 ≤ A ≤ 38↗