Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomedical support”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Hypergravity-induced immunomodulation in a rodent model: lymphocytes and lymphoid organs

The major goal of this study was to quantify changes in lymphoid organs and cells over time due to centrifugation-induced hypergravity. C57BL/6 mice were exposed to 1, 2 and 3 G and the following assays were performed on days 1, 4, 7, 10, and 21: spleen, thymus, lung, and liver masses; total leukocyte, lymphocyte, monocyte/macrophage, and granulocyte counts; level of splenocyte apoptosis; enumeration of CD3+ T, CD3+/CD4+ T helper, CD3+/CD8+ T cytotoxic, B220+ B, and NK1.1+ natural killer cells; and quantification of cells expressing CD25, CD69, and CD71 activation markers. The data show that increased gravity resulted in decreased body, spleen, thymus, and liver, but not lung, mass. Significant reductions were noted in all three major leukocyte populations (lymphocytes, granulocytes, monocyte/macrophages) [correction of macrphages] with increased gravity; persistent depletion was noted in blood but not spleen. Among the various lymphocyte populations, the CD3+/CD8+ T cells and B220+ B cells were the most affected and NK1.1+ NK cells the least affected. Overall, the changes were most evident during the first week, with a greater influence noted for cells in the spleen. A linear relationship was found between some of the measurements and the level of gravity, especially on day 4. These findings indicate that hypergravity profoundly alters leukocyte number and distribution in a mammalian model and that some aberrations persisted throughout the three weeks of the study. In certain cases, the detected changes were similar to those observed after whole-body irradiation. In future investigations we hope to combine hypergravity with low-dose rate irradiation and immune challenge.

Non-NASA Center↗

Flexor bias of joint position in humans during spaceflight

The ability to estimate ankle and elbow joint position was tested before, during, and after a 17-day spaceflight. Subjects estimated targeted joint angles during isovelocity (IsoV) joint movements with agonist muscle groups either active or relaxed. These movements included elbow extension (EE) and elbow flexion (EF), and plantarflexion (PF) and dorsiflexion (DF) of the ankle. Subjects also estimated these joint positions while moving the dynamometer at their chosen (variable) velocity (VarV) during EE and PF. For IsoV tests, no differences were observed between active and passive movements for either the ankle or elbow. Compared with those of pre-flight test days, estimates of targeted elbow joint angles were approximately 5 degrees to 15 degrees more flexed in-flight, and returned toward the pre-flight values during recovery. The spaceflight effects for the ankle were inconsistent and less prevalent than those for the elbow. The VarV PF test condition for the 120 degrees target angle at the ankle exhibited approximately 5 degrees to 7 degrees more DF target angle estimates in-flight compared with those pre- or post-flight. In contrast, during IsoV PF there was a tendency for ankle estimates to be approximately 2 degrees to 3 degrees more PF after 2-3 days exposure to spaceflight. These data indicate that during spaceflight the perception of elbow extension is greater than actuality, and are consistent with the interpretation that microgravity induced a flexor bias in the estimation of the actual elbow joint position. Moreover, these effects in joint proprioception during spaceflight were observed in individual isolated single-joint movements during tasks in which vestibular function in maintaining posture were minimal.

STS-78 Shuttle Project↗

Time course of epiphyseal growth plate fusion in rat tibiae

Although the rat is the most common animal model used in studying osteoporosis, it is often used inappropriately. Osteoporosis is a disease that most commonly occurs in humans long after growth plate fusion with the associated cessation of longitudinal bone growth, but there has been a question as to when or to what extent the rat growth plate fuses. To investigate this question, we used microcomputed X-ray tomography, at voxel resolutions ranging from (5.7 micro m)(3) to (11 micro m)(3), to image the proximal epiphyseal growth plates of both male (n = 19) and female (n = 15) rat tibiae, ranging in age from 2 to 25 months. The three-dimensional images were used to evaluate fusion of the epiphyseal growth plate by quantitating the amount of cancellous bone that has bridged across the growth plate. The results suggest that the time course of fusion of the epiphyseal growth plate follows a sigmoidal pattern, with 10% of the maximum number of bridges having formed by 3.9 months in the male tibiae and 5.8 months in the female tibiae, 50% of the maximum number of bridges having formed by 5.6 months in the male tibiae and 5.9 months in the female tibiae, and 90% of the total maximum of bridges have formed by 7.4 months for the males and 6.5 months for the females. The total volume of bridges per tibia at the age at which the maximum number of bridges per tibia has first formed is 0.99 mm(3)/tibia for the males and 0.40 mm(3)/tibia for the females. After the maximum number of bridges (-290 for females, -360 for males) have formed the total volume of bridges per tibia continues to increase for an additional 7.0 months in the males and 17.0 months for the females until they reach maximum values (-1.5 mm(3)/tibia for the males and -2.2 mm(3)/tibia for the females).

NASA Discipline Cell Biology↗

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Evaluation Studies↗

Ten-fold augmentation of endothelial uptake of vascular endothelial growth factor with ultrasound after systemic administration

OBJECTIVES: In this study, the feasibility of delivering and enhancing the uptake of vascular endothelial growth factor (VEGF) into the intact endothelium by using ultrasound (US) facilitation was determined. BACKGROUND: A limitation of tissue-targeted drug delivery is the need for direct arterial cannulation. We postulate a mechanism by which agents injected intravenously may be targeted to a tissue using US and ultrasonic contrast agents. METHODS: We used a rat model to test the ability of US and an ultrasonic contrast agent perflurocarbon exposed sonicated dextrose albumin (PESDA) to increase uptake of VEGF in the myocardium. Continuous wave Doppler US (0.6 W/cm2 at 1 MHz for 15 min) was applied to the chest wall overlying the myocardium during intravenous injection with either VEGF (100 microg/kg) alone or a combination of VEGF and PESDA (0.1%). Control rats had VEGF infused without US or PESDA. The VEGF uptake was measured quantitatively in the heart, lung, liver and kidneys by enzyme-linked immunosorbent assay (ng/g of tissue) and morphologically by fluorescence microscopy. RESULTS: There was an eight-fold increase in VEGF uptake in the heart by US alone (16.86 +/- 1.56 vs. 2.11 +/- 0.953 ng/g of tissue, p < 0.0001) and a 13-fold increase with US + PESDA (26.78 +/- 2.88 vs. 2.11 +/- 0.953 ng/g of tissue, p < 0.0001) compared with control rats. Fluorescence microscopy revealed deposition of VEGF in the endothelium of small intramyocardial arterioles. CONCLUSIONS: These results show a marked increase in endothelial VEGF uptake with US and US + PESDA. Thus, US may be used to augment endothelial VEGF uptake 10-fold to 13-fold.

Non-NASA Center↗

TAK1 is activated in the myocardium after pressure overload and is sufficient to provoke heart failure in transgenic mice

The transforming-growth-factor-beta-activated kinase TAK1 is a member of the mitogen-activated protein kinase kinase kinase family, which couples extracellular stimuli to gene transcription. The in vivo function of TAK1 is not understood. Here, we investigated the potential involvement of TAK1 in cardiac hypertrophy. In adult mouse myocardium, TAK1 kinase activity was upregulated 7 days after aortic banding, a mechanical load that induces hypertrophy and expression of transforming growth factor beta. An activating mutation of TAK1 expressed in myocardium of transgenic mice was sufficient to produce p38 mitogen-activated protein kinase phosphorylation in vivo, cardiac hypertrophy, interstitial fibrosis, severe myocardial dysfunction, 'fetal' gene induction, apoptosis and early lethality. Thus, TAK1 activity is induced as a delayed response to mechanical stress, and can suffice to elicit myocardial hypertrophy and fulminant heart failure.

NASA Discipline Cardiopulmonary↗

Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction

This paper presents a new reconstruction algorithm for both single- and dual-energy computed tomography (CT) imaging. By incorporating the polychromatic characteristics of the X-ray beam into the reconstruction process, the algorithm is capable of eliminating beam hardening artifacts. The single energy version of the algorithm assumes that each voxel in the scan field can be expressed as a mixture of two known substances, for example, a mixture of trabecular bone and marrow, or a mixture of fat and flesh. These assumptions are easily satisfied in a quantitative computed tomography (QCT) setting. We have compared our algorithm to three commonly used single-energy correction techniques. Experimental results show that our algorithm is much more robust and accurate. We have also shown that QCT measurements obtained using our algorithm are five times more accurate than that from current QCT systems (using calibration). The dual-energy mode does not require any prior knowledge of the object in the scan field, and can be used to estimate the attenuation coefficient function of unknown materials. We have tested the dual-energy setup to obtain an accurate estimate for the attenuation coefficient function of K2 HPO4 solution.

NASA Center ARC↗

Orthostatic intolerance and tachycardia associated with norepinephrine-transporter deficiency

BACKGROUND: Orthostatic intolerance is a syndrome characterized by lightheadedness, fatigue, altered mentation, and syncope and associated with postural tachycardia and plasma norepinephrine concentrations that are disproportionately high in relation to sympathetic outflow. We tested the hypothesis that impaired functioning of the norepinephrine transporter contributes to the pathophysiologic mechanism of orthostatic intolerance. METHODS: In a patient with orthostatic intolerance and her relatives, we measured postural blood pressure, heart rate, plasma catecholamines, and systemic norepinephrine spillover and clearance, and we sequenced the norepinephrine-transporter gene and evaluated its function. RESULTS: The patient had a high mean plasma norepinephrine concentration while standing, as compared with the mean (+/-SD) concentration in normal subjects (923 vs. 439+/-129 pg per milliliter [5.46 vs. 2.59+/-0.76 nmol per liter]), reduced systemic norepinephrine clearance (1.56 vs. 2.42+/-0.71 liters per minute), impairment in the increase in the plasma norepinephrine concentration after the administration of tyramine (12 vs. 56+/-63 pg per milliliter [0.07 vs. 0.33+/-0.37 pmol per liter]), and a disproportionate increase in the concentration of plasma norepinephrine relative to that of dihydroxyphenylglycol. Analysis of the norepinephrine-transporter gene revealed that the proband was heterozygous for a mutation in exon 9 (encoding a change from guanine to cytosine at position 237) that resulted in more than a 98 percent loss of function as compared with that of the wild-type gene. Impairment of synaptic norepinephrine clearance may result in a syndrome characterized by excessive sympathetic activation in response to physiologic stimuli. The mutant allele in the proband's family segregated with the postural heart rate and abnormal plasma catecholamine homeostasis. CONCLUSIONS: Genetic or acquired deficits in norepinephrine inactivation may underlie hyperadrenergic states that lead to orthostatic intolerance.

Non-NASA Center↗

Subendocardial motion in hypertrophic cardiomyopathy: assessment from long- and short-axis views by pulsed tissue Doppler imaging

BACKGROUND: Tissue Doppler imaging (TDI) is a recently developed technique that allows the instantaneous measurement of intrinsic regional myocardial motion velocity. Pulsed TDI is capable of separately assessing left ventricular (LV) regional motion velocity caused by circumferential and longitudinal fiber contraction. This particular feature of function is still controversial in patients with hypertrophic cardiomyopathy (HC). METHODS: To better characterize intrinsic circumferential and longitudinal LV systolic myocardial function in HC, we used pulsed TDI to measure short- and long-axis LV motion velocities, respectively. The subendocardial motion velocity patterns at the middle of the LV posterior wall (PW) and ventricular septum (IVS) in LV parasternal and apical long-axis views were recorded by pulsed TDI in 19 patients with nonobstructive HC and in 21 normal controls (NC). RESULTS: Peak short- and long-axis systolic subendocardial velocities in both the LV PW and IVS were significantly smaller in the HC group than in the NC group, and the time to peak velocity was significantly delayed. Furthermore, peak PW systolic velocity was significantly greater along the long axis than along the short axis in the NC group (8.8 +/- 1.5 cm/s vs 8.2 +/- 1.4 cm/s, P <.05), whereas the opposite was observed in the HC group (6.1 +/- 1.2 cm/s vs 7.5 +/- 1.0 cm/s, P <.0001). No significant differences were found in either group between the long- and short-axis IVS velocities (HC: 5.9 +/- 1.4 cm/s vs 5.5 +/- 1.3 cm/s; NC: 7.8 +/- 1.3 cm/s vs 7.9 +/- 1.6 cm/s). CONCLUSIONS: By using the capability of pulsed TDI for the evaluation of intrinsic myocardial velocity instantaneously in a specific region and direction, we found impairment of LV myocardial systolic function in patients with HC not only in the hypertrophied IVS but also in the nonhypertrophied LV PW. We also found a greater decrease in LV PW velocities along the long axis than the short axis, suggesting greater impairment of long-axis contraction in patients with HC. Because our HC patients did not appear to have excessive intracavitary pressure, these results suggest that the relatively normal-appearing PW is directly affected by the HC pathologic process.

NASA Program Biomedical Research and Countermeasur↗

Cardiopulmonary baroreceptor control of muscle sympathetic nerve activity in heat-stressed humans

Whole body heating decreases central venous pressure (CVP) while increasing muscle sympathetic nerve activity (MSNA). In normothermia, similar decreases in CVP elevate MSNA, presumably via cardiopulmonary baroreceptor unloading. The purpose of this project was to identify whether increases in MSNA during whole body heating could be attributed to cardiopulmonary baroreceptor unloading coincident with the thermal challenge. Seven subjects were exposed to whole body heating while sublingual temperature, skin blood flow, heart rate, arterial blood pressure, and MSNA were monitored. During the heat stress, 15 ml/kg warmed saline was infused intravenously over 7-10 min to increase CVP and load the cardiopulmonary baroreceptors. We reported previously that this amount of saline was sufficient to return CVP to pre-heat stress levels. Whole body heating increased MSNA from 25 +/- 3 to 39 +/- 3 bursts/min (P < 0. 05). Central blood volume expansion via rapid saline infusion did not significantly decrease MSNA (44 +/- 4 bursts/min, P > 0.05 relative to heat stress period) and did not alter mean arterial blood pressure (MAP) or pulse pressure. To identify whether arterial baroreceptor loading decreases MSNA during heat stress, in a separate protocol MAP was elevated via steady-state infusion of phenylephrine during whole body heating. Increasing MAP from 82 +/- 3 to 93 +/- 4 mmHg (P < 0.05) caused MSNA to decrease from 36 +/- 3 to 15 +/- 4 bursts/min (P < 0.05). These data suggest that cardiopulmonary baroreceptor unloading during passive heating is not the primary mechanism resulting in elevations in MSNA. Moreover, arterial baroreceptors remain capable of modulating MSNA during heat stress.

NASA Discipline Cardiopulmonary↗

Directional abnormalities of vestibular and optokinetic responses in cerebellar disease

Directional abnormalities of vestibular and optokinetic responses in patients with cerebellar degeneration are reported. Three-axis magnetic search-coil recordings of the eye and head were performed in eight cerebellar patients. Among these patients, examples of directional cross-coupling were found during (1) high-frequency, high-acceleration head thrusts; (2) constant-velocity chair rotations with the head fixed; (3) constant-velocity optokinetic stimulation; and (4) following repetitive head shaking. Cross-coupling during horizontal head thrusts consisted of an inappropriate upward eye-velocity component. In some patients, sustained constant-velocity yaw-axis chair rotations produced a mixed horizontal-torsional nystagmus and/or an increase in the baseline vertical slow-phase velocity. Following horizontal head shaking, some patients showed an increase in the slow-phase velocity of their downbeat nystagmus. These various forms of cross-coupling did not necessarily occur to the same degree in a given patient; this suggests that different mechanisms may be responsible. It is suggested that cross-coupling during head thrusts may reflect a loss of calibration of brainstem connections involved in the direct vestibular pathways, perhaps due to dysfunction of the flocculus. Cross-coupling during constant-velocity rotations and following head shaking may result from a misorientation of the angular eye-velocity vector in the velocity-storage system. Finally, responses to horizontal optokinetic stimulation included an inappropriate torsional component in some patients. This suggests that the underlying organization of horizontal optokinetic tracking is in labyrinthine coordinates. The findings are also consistent with prior animal-lesion studies that have shown a role for the vestibulocerebellum in the control of the direction of the VOR.

NASA Discipline Neuroscience↗

A geometric deformable model for echocardiographic image segmentation

Gradient vector flow (GVF), an elegant external force for parametric deformable models, can capture object boundaries from both sides. A new geometric deformable model is proposed that combines GVF and the geodesic active contour model. The level set method is used as the numerical method of this model. The model is applied for echocardiographic image segmentation.

NASA Program Biomedical Research and Countermeasur↗

Cranial diameter pulsations measured by non-invasive ultrasound decrease with tilt

INTRODUCTION: Intracranial pressure (ICP) may play a significant role in physiological responses to microgravity by contributing to the nausea associated with microgravity exposure. However, effects of altered gravity on ICP in astronauts have not been investigated, primarily due to the invasiveness of currently available techniques. We have developed an ultrasonic device that monitors changes in cranial diameter pulsation non-invasively so that we can evaluate ICP dynamics in astronauts during spaceflight. This study was designed to demonstrate the feasibility of our ultrasound technique under the physiological condition in which ICP dynamics are changed due to altered gravitational force. METHODS: Six healthy volunteers were placed at 60 degrees head-up, 30 degrees headup, supine, and 15 degrees head-down positions for 3 min at each angle. We measured arterial blood pressure (ABP) with a finger pressure cuff, and cranial diameter pulsation with a pulsed phase lock loop device (PPLL). RESULTS: Analysis of covariance demonstrated that amplitudes of cranial diameter pulsations were significantly altered with the angle of tilt (p < 0.001). The 95% confidence interval for linear regression coefficients of the cranial diameter pulsation amplitudes with tilt angle was 0.862 to 0.968. However, ABP amplitudes did not show this relationship. DISCUSSION: Our noninvasive ultrasonic technique reveals that the amplitude of cranial diameter pulsation decreases as a function of tilt angle, suggesting that ICP pulsation follows the same relationship. It is demonstrated that the PPLL device has a sufficient sensitivity to detect changes non-invasively in ICP pulsation caused by altered gravity.

NASA Program Biomedical Research and Countermeasur↗

In vivo regulation of the beta-myosin heavy chain gene in soleus muscle of suspended and weight-bearing rats

In the weight-bearing hindlimb soleus muscle of the rat, approximately 90% of muscle fibers express the beta-myosin heavy chain (beta-MHC) isoform protein. Hindlimb suspension (HS) causes the MHC isoform population to shift from beta toward the fast MHC isoforms. Our aim was to establish a model to test the hypothesis that this shift in expression is transcriptionally regulated through specific cis elements of the beta-MHC promoter. With the use of a direct gene transfer approach, we determined the activity of different length beta-MHC promoter fragments, linked to a firefly luciferase reporter gene, in soleus muscle of control and HS rats. In weight-bearing rats, the relative luciferase activity of the longest beta-promoter fragment (-3500 bp) was threefold higher than the shorter promoter constructs, which suggests that an enhancer sequence is present in the upstream promoter region. After 1 wk of HS, the reporter activities of the -3500-, -914-, and -408-bp promoter constructs were significantly reduced ( approximately 40%), compared with the control muscles. However, using the -215-bp construct, no differences in promoter activity were observed between HS and control muscles, which indicates that the response to HS in the rodent appears to be regulated within the -408 and -215 bp of the promoter.

Non-NASA Center↗

Analysis of shape and motion of the mitral annulus in subjects with and without cardiomyopathy by echocardiographic 3-dimensional reconstruction

The shape and dynamics of the mitral annulus of 10 patients without heart disease (controls), 3 patients with dilated cardiomyopathy, and 5 patients with hypertrophic obstructive cardiomyopathy and normal systolic function were analyzed by transesophageal echocardiography and 3-dimensional reconstruction. Mitral annular orifice area, apico-basal motion of the annulus, and nonplanarity were calculated over time. Annular area was largest in end diastole and smallest in end systole. Mean areas were 11.8 +/- 2.5 cm(2) (controls), 15.2 +/- 4.2 cm(2) (dilated cardiomyopathy), and 10.2 +/- 2.4 cm(2) (hypertrophic cardiomyopathy) (P = not significant). After correction for body surface, annuli from patients with normal left ventricular function were smaller than annuli from patients with dilated cardiomyopathy (5.9 +/- 1.2 cm(2)/m(2) vs 7.7 +/- 1.0 cm(2)/m(2); P <.02). The change in area during the cardiac cycle showed significant differences: 23.8% +/- 5.1% (controls), 13.2% +/- 2.3% (dilated cardiomyopathy), and 32.4% +/- 7.6% (hypertrophic cardiomyopathy) (P <.001). Apico-basal motion was highest in controls, followed by those with hypertrophic obstructive and dilated cardiomyopathy (1.0 +/- 0.3 cm, 0.8 +/- 0.2 cm, 0.3 +/- 0.2 cm, respectively; P <.01). Visual inspection and Fourier analysis showed a consistent pattern of anteroseptal and posterolateral elevations of the annulus toward the left atrium. In conclusion, although area changes and apico-basal motion of the mitral annulus strongly depend on left ventricular systolic function, nonplanarity is a structural feature preserved throughout the cardiac cycle in all three groups.

Non-NASA Center↗

Primate translational vestibuloocular reflexes. III. Effects of bilateral labyrinthine electrical stimulation

The effects of functional, reversible ablation and potential recruitment of the most irregular otolith afferents on the dynamics and sensitivity of the translational vestibuloocular reflexes (trVORs) were investigated in rhesus monkeys trained to fixate near and far targets. Translational motion stimuli consisted of either steady-state lateral and fore-aft sinusoidal oscillations or short-lasting transient lateral head displacements. Short-duration (usually <2 s) anodal (inhibitory) and cathodal (excitatory) currents (50-100 microA) were delivered bilaterally during motion. In the presence of anodal labyrinthine stimulation, trVOR sensitivity and its dependence on viewing distance were significantly decreased. In addition, anodal currents significantly increased phase lags. During transient motion, anodal stimulation resulted in significantly lower initial eye acceleration and more sluggish responses. Cathodal currents tended to have opposite effects. The main characteristics of these results were simulated by a simple model where both regularly and irregularly discharging afferents contribute to the trVORs. Anodal labyrinthine currents also were found to decrease eye velocity during long-duration, constant velocity rotations, although results were generally more variable compared with those during translational motion.

NASA Program Biomedical Research and Countermeasur↗

A role for cysteine 3635 of RYR1 in redox modulation and calmodulin binding

Oxidation of the skeletal muscle Ca(2+) release channel (RYR1) increases its activity, produces intersubunit disulfide bonds, and blocks its interaction with calmodulin. Conversely, bound calmodulin protects RYR1 from the effects of oxidants (Zhang, J.-Z., Wu, Y., Williams, B. Y., Rodney, G., Mandel, F., Strasburg, G. M., and Hamilton, S. L. (1999) Am. J. Physiol. 276, Cell Physiol. C46-C53). In addition, calmodulin protects RYR1 from trypsin cleavage at amino acids 3630 and 3637 (Moore, C. P., Rodney, G., Zhang, J.-Z., Santacruz-Toloza, L., Strasburg, G. M., and Hamilton, S. L. (1999) Biochemistry 38, 8532-8537). The sequence between these two tryptic sites is AVVACFR. Alkylation of RYR1 with N-ethylmaleimide (NEM) blocks both (35)S-apocalmodulin binding and oxidation-induced intersubunit cross-linking. In the current work, we demonstrate that both cysteines needed for the oxidation-induced intersubunit cross-link are protected from alkylation with N-ethylmaleimide by bound calmodulin. We also show, using N-terminal amino acid sequencing together with analysis of the distribution of [(3)H]NEM labeling with each sequencing cycle, that cysteine 3635 of RYR1 is rapidly labeled by NEM and that this labeling is blocked by bound calmodulin. We propose that cysteine 3635 is located at an intersubunit contact site that is close to or within a calmodulin binding site. These findings suggest that calmodulin and oxidation modulate RYR1 activity by regulating intersubunit interactions in a mutually exclusive manner and that these interactions involve cysteine 3635.

Non-NASA Center↗

Initial clinical experience of real-time three-dimensional echocardiography in patients with ischemic and idiopathic dilated cardiomyopathy

The geometry of the left ventricle in patients with cardiomyopathy is often sub-optimal for 2-dimensional ultrasound when assessing left ventricular (LV) function and localized abnormalities such as a ventricular aneurysm. The aim of this study was to report the initial experience of real-time 3-D echocardiography for evaluating patients with cardiomyopathy. A total of 34 patients were evaluated with the real-time 3D method in the operating room (n = 15) and in the echocardiographic laboratory (n = 19). Thirteen of 28 patients with cardiomyopathy and 6 other subjects with normal LV function were evaluated by both real-time 3-D echocardiography and magnetic resonance imaging (MRI) for obtaining LV volumes and ejection fractions for comparison. There were close relations and agreements for LV volumes (r = 0.98, p <0.0001, mean difference = -15 +/- 81 ml) and ejection fractions (r = 0.97, p <0.0001, mean difference = 0.001 +/- 0.04) between the real-time 3D method and MRI when 3 cardiomyopathy cases with marked LV dilatation (LV end-diastolic volume >450 ml by MRI) were excluded. In these 3 patients, 3D echocardiography significantly underestimated the LV volumes due to difficulties with imaging the entire LV in a 60 degrees x 60 degrees pyramidal volume. The new real-time 3D echocardiography is feasible in patients with cardiomyopathy and may provide a faster and lower cost alternative to MRI for evaluating cardiac function in patients.

NASA Discipline Cardiopulmonary↗