Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

An interlaboratory comparison of piston-cylinder pressure calibration using the albite-breakdown reaction.

An attempt is made to compare pressure calibration methods among several laboratories in an unbiased way to produce some indication of the bandwidth of observations on the pressure of an equilibrium reaction where sources of discrepancy not resulting from pressure calibration are likely to have been eliminated. The reaction chosen is the breakdown of albite to jadeite and quartz under pressure.

Johannes, W.↗

A calibration adjustment technique combining ERB parameters from different remote sensing platforms into a long-term data set

Earth-radiation-budget (ERB) experiments on board the Nimbus-6 (ERB 6) and Nimbus-7 (ERB 7) spacecraft have measured wide-field-of-view total (0.2 to 50 micron), shortwave (0.2 to 3.8 micron), and near-infrared (0.7 to 2.8 micron) terrestrial irradiances for a joint lifetime of over 8 years. Though the spectral characteristics of both experiments are nearly identical, instrument degradation and altitude differences introduce discrepancies between the two data sets. ERB parameters from these two observing platforms may be combined into a scientifically meaningful data set only after these discrepancies are eliminated. To facilitate the creation of a long-term ERB data set, comparisons of the ERB 6 experiment irradiances with, and calibration adjustments with respect to, the corresponding ERB 7 irradiances have been performed. Two calibration methods were developed and applied to the irradiance data from 28 pairs of collocated orbits. The differential effects of altitude, illumination, albedo, and scene inhomogeneities were applied. The result is a set of calibration adjustments that adjust the ERB 6 data to match the ERB 7 data.

Ardanuy, P. E.↗

Electrochemical and Hydrodynamic Interferences on the Performances of an Oxygen Microsensor with Built-in Electrochemical Microactuator

A concept of novel electrochemical in situ self-calibration technique for an oxygen microsensor has been proposed to devise a convenient calibration method without an externally coupled apparatus. Systemic investigations on the influences of various electrochemical (pH) and hydrodynamic (solution stirring) conditions on the proposed microsensor performances are presented. The results suggest that: 1) The calibrating microenvironments can be manipulated with carefully engineered sensor designs and optimized generating signals; 2) The external oxygen permeable membrane is needed to minimize the electrochemical and hydrodynamic interferences.

Kim, Chang-Soo↗

Raman Lidar Water Vapor Mixing Ratio and Temperature Value-Added Products

This report describes the methods used to estimate profiles of water vapor mixing ratio (WVMR) and temperature from the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility Raman lidars (RL). This includes a description of the equations and the calibration methods that are used, as well as the output datastreams and variable names. We begin with an overview of the ARM RL systems, with a focus on the detection channels used for the WVMR and temperature measurements.

54 ENVIRONMENTAL SCIENCES↗

Coherence imaging spectroscopy at Wendelstein 7-X for impurity flow measurements

In the last decade, Coherence Imaging Spectroscopy (CIS) has shown distinctive results in measuring ion flow velocities in the edge of magnetically confined plasma devices. Its 2D spatially resolved measurement capabilities and its high optical throughput are ideal for investigating the impurity behavior in the complex 3D magnetic island topology edge of Wendelstein 7-X (W7-X). However, a highly precise and stable calibration method is required for a reliable diagnostic operation. A new level of precision and stability has been achieved for the two CIS systems installed at W7-X with the use of a new calibration source, a continuous tunable laser commercially available only since 2015. A specific prototype model was successfully adapted to the challenging requirements of W7-X, granting high accuracy (±0.01 pm) and flexibility (spectral range: 450–650 nm) in the wavelength calibration required for measuring low-Z impurity ion flow velocities. These features opened up new investigation possibilities on temperature stability and wavelength response of the CIS components, allowing to fully characterize and validate the W7-X systems. The CIS diagnostic was operational throughout the last W7-X experimental campaign. Measured velocities on the order of ~20–30 km/s were observed, corroborated by comparisons with measurements with Mach probes.

47 OTHER INSTRUMENTATION↗

A measurement of the proton’s spin structure function g2 at low Q2

JLab E08-027, a measurement of g2p and the longitudinal-transverse (LT) spin polarizability, successfully collected data from March to May, 2012. Nucleon spin structure study has been an active research area, which has attracted a very large effort from both experimentalists and theorists. The spin structure study for the last 2 decades has provided us with many exciting and often surprising results. Recently, new precision results in the low-to-intermediate momentum transfer Q2 region from JLab have provided extensive information on the nucleon structure in the confinement region and the transition region between asymptotic free to confinement. In particular, the extensive comparisons of experimental results with Chiral Perturbation Theory (the effective theory of QCD at low energy) calculations show general good agreements, but strong disagreement in the case of the neutron LT spin polarizability. This experiment completed the measurements of gp2 and the LT spin polarizability on the proton in the low-to-intermediate Q2 region. The experiment used a polarized proton (NH3) target for the first time in Hall A. Scattered electrons were detected by a pair of Hall A high resolution spectrometer (HRS) with a pair of septum magnets. To avoid too much depolarization of the target, beam current was limited to 50-100 nA during the experiment. Since the existing beam current monitors (BCMs), beam position monitors (BPMs) and calibration methods did not work at such a low current range, new BPM and BCM receivers were designed and used for current condition. A pair of super-harps and a tungsten calorimeter were installed to calibrate the BPMs and BCMs. To compensate for the effect of the 2.5/5T transverse magnet field, two chicane dipole magnets were installed. A pair of slow rasters were installed for the first time in Hall A, combining with a pair of fast raster. The standard Hall A DAQ system and the improved high resolution DAQ system were used to record the detector information and the helicity dependent beam information, respectively. In order to achieve the required accuracy of the beam position and angle and reconstruct them event by event at the target location, the data of the BPMs and harps were carefully analyzed. The final uncertainty of BCM after the calibration using the tungsten calorimeter is below 1%, which is important for the asymmetry extraction. Before the acceptance and the dilution factor are available, the models from fitting to the world data were used instead to extract the unpolarized cross section and the dilution factor. The longitudinal and transverse physics asymmetries were extracted and compared with the model, with the study of the radiative correction. The preliminary g1 and g2 results were then extracted using the measured asymmetry and the model.

Zhu, Pengjia↗

Advancements in Constitutive Model Calibration: Leveraging the Power of Full‐Field DIC Measurements and In Situ Load Path Selection for Reliable Parameter Inference

Accurate material characterization and model calibration are essential for computationally supported high-consequence engineering decisions. Historically, characterization and calibration methods (1) use simplified test specimen geometries and global data, (2) cannot guarantee that sufficient characterization data are collected for a specific model of interest, (3) use deterministic methods that provide best-fit parameter values with no uncertainty quantification, and (4) are sequential, inflexible, and time-consuming. This work brings together several recent advancements into an improved workflow called interlaced characterization and calibration (ICC) that advances the state-of-the-art in constitutive model calibration. The ICC paradigm (1) employs tools to efficiently use full-field data to calibrate high-fidelity material models, (2) aligns the data needed with the data collected by adopting an optimal experimental design protocol, (3) quantifies parameter uncertainty through Bayesian inference and (4) incorporates these advancements into a quasi real-time feedback loop. The ICC framework is demonstrated here on the calibration of a material model using simulated full-field data for an aluminium cruciform specimen being deformed biaxially. The cruciform is actively driven through the myopically preferred load path using Bayesian optimal experimental design, which selects load steps that yield the maximum expected information gain (EIG). Principal component analysis (PCA) is performed on the model predictions of full-field displacements, and fast surrogate models are built to approximate the input-output relationships of the expensive finite element model. Furthermore, the tools developed and demonstrated here show that high-fidelity constitutive models can be efficiently and reliably calibrated with quantified uncertainty, thus supporting credible decision-making and potentially increasing the agility of solid mechanics modelling by enabling utilization of computational simulations at earlier stages of the design cycle.

Bayesian optimal experimental design↗

Hawkeye Radiometric Calibration Methodology

Hawkeye is an ocean color instrument designed, manufactured and characterized at Cloud land Instruments, CA. It is a push broom instrument that has 8spectral bands similar to SeaWiFS and a spatial resolution of 120 m. Each spectral band has 1800 detectors (pixels) and all 14,000 detectors (pixels) need to be calibrated independently. This paper describes the preliminary design of on-orbit calibration method to correct for the instrument response's temperature sensitivity,scan angle dependency in radiometric sensitivity, relative spectral response (RSR),non linearity, and polarization sensitivity. We will provide a brief description on how each of the calibration parameters are used to address the instrument characteristics and how the calibration parameters are derived from instrument test data and use to retrieve ocean color products.

Lee, Shihyan↗

Air-kerma strength determination of a new directional {sup 103}Pd source

Purpose: A new directional {sup 103}Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing {sup 103}Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active {sup 103}Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S{sub K}) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S{sub K} to a well-type ionization chamber. Methods: S{sub K} measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S{sub K} from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S{sub K} with the presence of gold fluorescent energy lines. In addition to S{sub K} measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S{sub K} values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S{sub K} of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an S{sub K}-based calibration to a clinical user. S{sub K} per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the S{sub K} measurement approach. Conclusions: This characterization of a new {sup 103}Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield.

07 ISOTOPE AND RADIATION SOURCES↗

Specifications of Cladding Diameter Measurements Conducted at AGHCF

Fuel element diameter data was collected on-site at the Alpha-Gamma Hot Cell Facility (AGHCF) before and after out-of-pile furnace transient tests of fuel elements. Available data records have been collected and preserved in the Out-of-Pile Transient Database (OPTD). This data is used to determine the transient-induced changes in fuel element diameter, or cladding strain, for the Whole Pin Furnace (WPF) tests. Fuel element diameter was measured by contact profilometry along the length of the fuel pin at specified rotational orientations and/or by a manually operated micrometer at several discrete axial locations along the pin. The Alpha-Gamma Hot Cell Facility Operations Manual details the way the facility operated, organizational and oversight responsibilities, and procedures for examination of samples. The working version of the manual at the time of the whole pin furnace tests and the test pin examinations is Doc. No. IPS-2-00-00, dated June 1989. This specification was developed using the operations manual and recovered measurement records in consultation with subject matter experts (SMEs). The measurement methods, format of the available post-test examination (PTE) data, and recommended methods for use and interpretation of that data are summarized. Section 2 describes the available diameter measurement data for the WPF tests with guidance for interpretation and usage, and Section 3 describes the instrument measurement procedures and calibration methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Remotely Administered Psychoacoustic Test for sUAS Noise to Gauge Feasibility of Remote UAM Noise Study

The National Aeronautics and Space Administration (NASA) remotely administered a psychoacoustic test in fall of 2022 as the first of two phases of a cooperative Urban Air Mobility (UAM) vehicle noise human response study. The first phase, the Feasibility Test, described in this paper, determined the feasibility of the remote test method, in contrast to a previous in-person psychoacoustic test that found an annoyance response difference between small unmanned aerial system (sUAS) noise and ground vehicle noise. This paper discusses the Feasibility Test online layout, sound calibration method, remote test software development, stimuli selection, test subject recruitment, and test administration. Test performance is measured through comparison of annoyance response data with the previous in-person test results. The paper also investigates if providing a contextual cue to test subjects influenced their annoyance response. Response differences between test subjects in geographically distinct areas are analyzed. Administrative challenges that were encountered during the test are discussed. The second phase of this study, the implementation phase, will use a remote (web-based) test method and leverage the cooperation of multiple government agencies, academia, and industry to gain human response insights from a wide range of UAM vehicle sounds that would be challenging for a single organization to acquire. Improvements to administering a remote test for the implementation phase of the UAM vehicle noise human response study are recommended.

Remote Psychoacoustic Test↗

Remotely Administered Psychoacoustic Test for sUAS Noise to Gauge Feasibility of Remote UAM Noise Study

The National Aeronautics and Space Administration (NASA) remotely administered a psychoacoustic test in fall of 2022 as the first of two phases of a cooperative Urban Air Mobility (UAM) vehicle noise human response study. The first phase, the Feasibility Test, described in this paper, determined the feasibility of the remote test method, in contrast to a previous in-person psychoacoustic test that found an annoyance response difference between small unmanned aerial system (sUAS) noise and ground vehicle noise. This paper discusses the Feasibility Test online layout, sound calibration method, remote test software development, stimuli selection, test subject recruitment, and test administration. Test performance is measured through comparison of annoyance response data with the previous in-person test results. The paper also investigates if providing a contextual cue to test subjects influenced their annoyance response. Response differences between test subjects in geographically distinct areas are analyzed. Administrative challenges that were encountered during the test are discussed. The second phase of this study, the implementation phase, will use a remote (web-based) test method and leverage the cooperation of multiple government agencies, academia, and industry to gain human response insights from a wide range of UAM vehicle sounds that would be challenging for a single organization to acquire. Improvements to administering a remote test for the implementation phase of the UAM vehicle noise human response study are recommended.

Remote Psychoacoustic Test↗

MISR Calibration and implications for low-light-level aerosol retrieval over dark water.

The authors push the limits of the vicarious calibration method’s accuracy, aiming to assess absolute, camera-to-camera, and band-toband radiometry. Patterns repeated over many well-constrained cases lend confidence to the results, at a few percent accuracy, as do additional vicarious calibration tests performed with multiplatform observations taken during the Chesapeake Lighthouse and Aircraft Measurements for Satellites (CLAMS) campaign. Conclusions are strongest in the red and green bands, but are too uncertain to accept for the near-infrared. MISR nadir-view and MODIS low-light-level absolute reflectances differ by about 4% in the blue and green bands, with MISR reporting higher values.

Clark, Dennis↗

SSME Automated Engine Calibration System (AECS)

An algorithm is derived for the real-time calibration of the engine fuel flowmeter and the engine mixture ratio during Space Shuttle Main Engine (SSME) ground testing. Because currently used calibration methods are post-test operations, there exists no fail-safe way of predicting at what mixture ratio a planned test will run. It is proposed that the algorithm developed here be used as part of an Automated Engine Calibration System (AECS) which could ensure that nearly all SSME tests are run at the proper mixture ratio. In this way, AECS has the potential of increasing the efficiency of the SSME ground test program. In addition to the derivation of the algorithm, an overview of this calibration system is presented along with the list of test stand facility instrumentation necessary for AECS implementation.

Greene, William D.↗

Advancement of Functional Expansion Tallies Capabilities in Serpent 2

The need for accident tolerant fuels (ATFs) became self-evident after the series of unfortunate nuclear events at Fukushima Daiichi in 2011. Restarting the Transient Reactor Test Facility (TREAT) at INL is one component in this concerted effort to establish the ATF development and testing program under the United States Department of Energy. Prior to the closure of TREAT in 1994, each experiment required multiple low-power calibration tests before and after each run. Since then, computing advancements have set computer-based modeling and simulation (M and S) as the preferred calibration method. The anticipated savings are both temporal and monetary. MAMMOTH, a collection of M and S tools built from the finite element-based MOOSE Framework, has been established to support the designed experiments intended for TREAT. This collection of tools includes: 1) Rattlesnake, a striking diffusion-based neutronics code, 2) BISON, an advanced materials and fuels performance code, and 3) RELAP-7, a powerful thermal-hydraulics solver. Each is capable of independently performing its function accurately and effectively; unified, they create a powerful multiphysics reactor core M and S application. One unfortunate weakness in this configuration lies in the unique geometry and design of TREAT's core. Although simple to model, this poses a challenge to the diffusion solver in Rattlesnake. One alternative is to replace Rattlesnake with Serpent, a fully-fledged Monte Carlo (MC) neutronics code. Coincidentally, Rattlesnake calculations are frequently validated against Serpent simulations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wettability of graphitic-carbon and silicon surfaces: MD modeling and theoretical analysis

The wettability of graphitic carbon and silicon surfaces was numerically and theoretically investigated. A multi-response method has been developed for the analysis of conventional molecular dynamics (MD) simulations of droplets wettability. The contact angle and indicators of the quality of the computations are tracked as a function of the data sets analyzed over time. This method of analysis allows accurate calculations of the contact angle obtained from the MD simulations. Analytical models were also developed for the calculation of the work of adhesion using the mean-field theory, accounting for the interfacial entropy changes. A calibration method is proposed to provide better predictions of the respective contact angles under different solid-liquid interaction potentials. Estimations of the binding energy between a water monomer and graphite match those previously reported. In addition, a breakdown in the relationship between the binding energy and the contact angle was observed. The macroscopic contact angles obtained from the MD simulations were found to match those predicted by the mean-field model for graphite under different wettability conditions, as well as the contact angles of Si(100) and Si(111) surfaces. Finally, an assessment of the effect of the Lennard-Jones cutoff radius was conducted to provide guidelines for future comparisons between numerical simulations and analytical models of wettability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data processing and calibration for tunable diode laser harmonic absorption spectrometers

Data processing and calibration methods are described for tunable diode laser absorption spectrometers which produce harmonic absorption spectra as raw data for measuring gas mixing ratios down to parts-per-trillion levels at a variety of pressures. The methods, which take advantage of modern computer speed, memory, and data storage capabilities, are applicable to the detection of weakly absorbing gases in quantitative industrial monitoring, in addition to aircraft and balloon atmospheric measurements for which they were designed. Algorithms for calibration and data analysis, including rejection of erroneous spectra, variation of effective integration time, spectral alignment prior to averaging, and plotting and archiving of results, have been tested on actual stratospheric laser spectra recorded by the Aircraft Laser Infrared Absorption Spectrometer (ALIAS) spectrometer in numerous flights of NASA's ER-2 aircraft.

May, Randy D.↗