Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control of electric power systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Optical control of integer and fractional Chern insulators

Optical control of topology, particularly in the presence of electron correlations, is an interesting topic with broad scientific and technological impact. Twisted MoTe 2 bilayer (tMoTe 2 ) is a zero-field fractional Chern insulator (FCI), exhibiting the fractionally quantized anomalous Hall effect. As the chirality of the edge states and sign of the Chern number are determined by the underlying ferromagnetic polarization, manipulation of ferromagnetism would realize control of the Chern insulator (CI)/FCI states. Here, in this work, we demonstrate control of ferromagnetic polarization, and thus the CI and FCI states, by circularly polarized optical pumping in tMoTe 2 . At low excitation power, we achieve on-demand preparation of ferromagnetic polarization by optical training, that is, electrically tuning the system from non-ferromagnetic to desirable ferromagnetic states under helicity-selective optical pumping. With increased excitation power, we further realize direct optical switching of ferromagnetic polarization at a temperature far below the Curie temperature. Both optical training and direct switching are most effective near CI and FCI states, which we attribute to a gap-enhanced valley polarization of optically pumped holes. The magnetization can be dynamically switched by modulating the helicity of optical excitation. Spatially resolved measurements further demonstrate optical writing of ferromagnetic, and thus CI (or FCI) domains. Our work realizes precise optical control of a topological quantum many-body system with potential applications in topological spintronics, quantum memories and creation of exotic edge states by programmable patterning of integer and fractionally quantized anomalous Hall domains.

ferromagnetism↗

DECOVALEX-2023: Task D Final Report

Task D of DECOVALEX-2023 is focused on the simulation of the coupled thermal hydraulic-mechanical (THM) behaviour in the full-scale engineered barrier system (EBS). The Horonobe EBS experiment is the demonstration of the full-scale EBS in the underground research laboratory (URL) (performed by JAEA in the Horonobe URL in Japan). Task D consisted of the three steps, a preliminary step (Step 0), simulation of the laboratory tests (Step 1) and simulation of the in-situ full-scale EBS experiment (Step 2). Since the Horonobe EBS experiment demonstrates the vertical emplacement option of the EBS, the experiment gallery is also backfilled with the backfill material. Therefore, interaction between the EBS and the backfill material can also be demonstrated, such as deformation (change of density) of the buffer material. The underground water in the Horonobe URL is saline. This fact adds chemical processes to THM behaviour. For example, mechanical properties (such as swelling pressure of the buffer material and backfill material) and hydraulic properties (such as permeability of the buffer material and backfill material) change depending on the water chemistry. Task D was therefore a challenging Task focused on not only the relatively simple THM behaviour but also complex THM behaviour including chemical processes. Six research teams (BGR, CAS, JAEA, KAERI, SNL and Taipower) participated the Task D. BGR, CAS, JAEA, KAERI and Taipower research teams selected a THM approach, while the SNL research team selected a TH approach. Step 1 involved the simulation of laboratory test results and was important to check the numerical codes developed by the research teams. Step 1 was divided into four sub steps. The simulation results through the Step 1 identified the parameters for simulation of the Step 2. Basic parameters of the materials (buffer material, backfill material, rock mass, concrete, sand) were provided by JAEA. Special parameters which research team needed were identified by back analysis of Step 1. Most notably the mechanical behaviour of swelling and displacement depended on the applied model (elastic model or elastoplastic model). Parameters such as Young’s modulus were found to need smaller values than characterised in the fundamental laboratory test results (Step 1-1, 1-2) for the elastic model. Although laboratory experiments are usually simple, test results contained some error. For example, if the saturation level is 100 % or higher, it should be considered an error. This situation was presented in the Step 1-3. A possible reason is that the buffer material is a mixture of bentonite and silica sand. When a specimen is cut to measure volume or weight, sand grains will affect the measurement data. In Step 2, boundary conditions such as temperature on the surface of the simulated overpack, heater power of the electrical heaters installed in the simulated overpack, injection pressure and inflow rate of the test water, were applied. The outer boundary conditions can be selected using measured data (injection pressure and inflow rate of the test water that is controlled by the injection systems installed in the sand layer around the buffer material and in the boundary between backfill material and concrete support). Since such measured data has some noise, research teams developed their own simplified boundary conditions. Inner boundary conditions can be selected using measured data as heater power and temperature on the surface of the simulated overpack. These data also contain some noise, so research teams developed their own simplified developed boundary conditions. Task D validated various approaches thorough the simulation of the in-situ full scale EBS system including backfill of the gallery: variations in the coupling processes (THM or THC), analysis codes, and boundary conditions. Temperature distribution in the buffer material was simulated well by all research teams. This means thermal behaviour is not sensitive to the simulation approaches. Although the water content distribution on the outside of the buffer material was well simulated by all research teams, the simulation results differ from the measured values inside the buffer material (at the centre and inside, near the simulated overpack). The buffer material is made from tap water, but in the in-situ experiment, saline groundwater infiltrates the buffer material. Therefore, the selection of the hydraulic parameters of the buffer material greatly affects the simulation results of the re saturation behaviour of the buffer material. In the Horonobe EBS experiment, measured values suitable for validating the simulation results were not obtained near the simulated overpack. When simulating the pressure and deformation of the buffer material, the measurement data is easily affected by the installation conditions of the measurement sensors, so verifying the measurement data itself remains an issue. Mechanical simulation results differ depending on whether they are considered as elastic or elastoplastic phenomena. The accuracy of measured in-situ data can be assessed by detailed analysis comparing sampling specimen analysis and measured data. The Horonobe EBS experiment is scheduled to be dismantled in the future (FY2026 and 2027). This detailed dismantling investigation will finally confirm the measured data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EVs@Scale: NextGen Profiles EVSE Characterization 2025

As part of the U.S. DOE EVs@Scale consortium, the Next-Generation Profiles (NextGen Profiles [NGP]) project presents analysis and results from the characterization of high-power conductive and wireless charging infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. Electric Vehicle Service Equipment (EVSE) characterization involves testing over a wide range of DC charging currents and voltages during nominal and off-nominal conditions. This testing allows for a better understanding of the impact that high-power charging will have on the electric grid. A common set of standard test plans, procedures, and data requirements were applied to the characterization in this document with minor updates and improvements. This report covers all conductive characterization activities performed between October 2024 and September 2025 on the Delta Electronics 350KW Electric Vehicle Charging System, consisting of power cabinet model EIDN-U350KTA01 and dispenser model EIDD-U350SSUUAEG-350.Key Findings include: Output regulation, Efficiency and power factor, Load management, Grid Resilience, Smart Charge Management (SCM) performance, Thermal control system performance, Multi-port simultaneous charging performance, and Selected performance comparisons with other EVSEs characterized in the NextGen Profiles project. Hot and cold temperature testing was not conducted on the Delta 350KW due to laboratory limitations. Future research could include continued testing the Delta hardware under off-nominal temperature conditions including multi-port/multi-session simultaneous charge testing, in addition to collecting data on other high-power conductive chargers to augment.

25 ENERGY STORAGE↗

Using Qualified On-Site Nuclear Power Plant Simulators in Human Factors Validations of Control Room Upgrades

Existing commercial nuclear power plants (NPPs) are valuable assets in the infrastructure portfolio of the United States (U.S.) because they safely and reliably generate about 1/5th of all the electricity used. The instrumentation and control (I&C) systems in commercial NPPs are the ‘eyes and ears' of the operator, allowing operators to maintain situation awareness, thereby allowing the plant to operate safely and efficiently for all phases of operation. Because the I&C systems in NPPs are still mostly based on analog technologies, which are reliable but not especially cost-effective, upgrading the existing I&C in com-mercial NPPs to new digital I&C is very important. Furthermore, simulators and simulation are critical human factors engineering tools for this I&C modernization work. NPP control room simulators are essential test beds to simulate normal, abnormal, and emergency operations that allow human factors researchers to safely and realistically evaluate early design phase prototypes of the upgraded digital I&C, and validate final as-built digital I&C systems that have been modernized deployed in NPPs. This paper describes research performed using qualified on-site NPP simulators to perform human factors validations of digital I&C control room upgrades.

99 GENERAL AND MISCELLANEOUS↗

Signature Analysis Utilizing a Dynamic Molten Salt Reactor Model for MC&A

Moving from traditional fixed fuel nuclear reactor systems to a mobile, dynamic fuel system that has dissolved special nuclear material in a molten salt is a paradigm shift in several respects. One major consideration is how to develop effective nuclear material controls and accounting for these novel reactor systems. The Molten Salt Reactor Experiment is one example of a critical molten salt system and provided a significant reference library based on the documented effort. But it was low thermal power that was not intended to reflect a commercial scale electricity production design. Therefore, to facilitate and assist vendors with domestic licensing considerations, research is underway to identify methods that could be used for domestic safeguards approaches for these novel reactor systems. This research presents the results of a signature analysis of data generated from three simulated scenarios using the molten salt demonstration reactor model defined in the Transient Simulation Framework of Reconfigurable Modules. Each scenario provides 1 hour isotope inventories over a 180 day period. The scenarios investigated provide test cases to examine if direct gamma-ray spectroscopy of the fuel can be used to identify changes comparing a base case (no reactivity control and fixed fission contribution) to an insertion of reactivity (10 pcm no change in fission composition) and a change in fission composition. The analysis demonstrates that monitoring the total count rate in a highly collimated high-resolution photon energy spectrum is sensitive to perturbations imposed into the reactor model. The total photon count rate changes ≈2% for the fission composition change and ≈4.5% for the reactivity insertion compared to the base case. However, both scenarios show an increase in the total photon count rate. The total photon count rate can be used to identify changes due to power (number of fissions) but not due to a change in the material undergoing fission. To distinguish between the two cases of increased power, the photon spectrum would require an intensive analysis technique. A photon peak count rate ratio analysis could be used to identify changes in the fissile material fission generation in the core through identification of a static peak that shows little variation to the source of fission and a highly varying peak. The photon peak strength will ultimately be determined by the isotope’s fission yield. A preliminary analysis investigating the coupling of the isotope’s fission yield and its concentration in the fuel salt derived from the modeling has been performed. A ratio analysis of the photon peak count rates of 140 La to 99 Mo demonstrated that the reactivity insertion creates a distinct difference in the ratio compared to the fission composition change scenario.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Survey of baffle plate samples, specimen machining, and hydrogen measurements

This report outlines preliminary results on the survey and characterization of irradiated baffle plate, baffle former, and flux thimble tube specimens as part of the ongoing investigation into irradiation-induced embrittlement in austenitic stainless steels at ambient (room temperature) conditions. The specimens originated from commercial pressurized water reactor (PWR) components, covering displacement damage doses ranging from approximately 0.065 to 75 dpa. Initial scanning electron microscopy (SEM) surveys revealed that specimen surfaces exhibited fine machining marks and in-service-formed oxide layers on the side surfaces of the analyzed specimens. The oxide layers revealed specific features resembling localized "pitting-like" corrosion. An additional set of specimens representing in-service oxidation is being preserved for future microstructure analysis work. As believed, this will provide additional insights into long-term material degradation in PRWs. Specimen machining challenges emerged due to a complex failure of the electric discharge machining (EDM) system located in hot area. Despite partial restoration, issues persist with the EDM’s secondary power supply, necessitating the exploration of alternative EDM or computer numerical control (CNC) machining approaches to facilitate tensile specimen preparation. Currently, low speed saw cutting is in progress to prepare specimens for hydrogen measurements and general microstructure analysis. The near-term goals include completing tensile specimen machining for advanced mechanical testing and characterizing fracture mechanisms, and stress-corrosion cracking testing, ultimately aiming to identify and mitigate the ambient-condition intergranular cracking through targeted post-irradiation annealing strategies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Grid ancillary services using electrolyzer-Based power-to-Gas systems with increasing renewable penetration

Increasing penetrations of renewable-based generation have led to a decrease in the bulk power system inertia and an increase in intermittency and uncertainty in generation. Energy storage is considered to be an important factor to help manage renewable energy generation at greater penetrations. Hydrogen is a viable long-term storage alternative. This paper analyzes and presents use cases for leveraging electrolyzer-based power-to-gas systems for electric grid support. The paper also discusses some grid services that may favor the use of hydrogen-based storage over other forms such as battery energy storage. Real-time controls are developed, implemented and demonstrated using a power-hardware-in-the-loop(PHIL) setup with a 225-kW proton-exchange-membrane electrolyzer stack. These controls demonstrate frequency and voltage support for the grid for different levels of renewable penetration (0%, 25%, and 50%). A comparison of the results shows the changes in respective frequencies and voltages as seen as different buses as a result of support from the electrolyzers and notes the impact on hydrogen production as a result of grid support. Finally, the paper discusses the practical nuances of implementing the tests with physical hardware, such as inverter/electrolyzer efficiency, as well as the related constraints and opportunities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System

Frequency control from photovoltaic (PV) power plants has great potential to address the frequency response challenge of the power system with high penetrations of renewable generation. Using model-based approaches to determine the optimal PV headroom reserve, however, requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic 1-day operation profile of the WECC system and demonstrates a savings of more than 40% PV headroom compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

frequency control↗

Framework for Large-scale Implementation of Wholesale-Retail Transactive Control Mechanism

Transactive energy is a control technique that uses market mechanisms to achieve desired control objectives. Several simulation studies and field demonstrations were carried out in recent years, but all focused on small scale systems and purpose-built simplified models which are not always capable of pointing out all the advantages and shortcomings of transac- tive energy methods. This work describes a co-simulation framework built on a hierarchical control architecture that allows for conducting studies of the impacts of a very large-scale deployment of transactive energy. The hierarchical transactive control architecture adopted in this work helps with alleviating computation and communication burden to facilitate a more effective large scale real-time market operation among device level resources and the system level operators. The co-simulation framework is evaluated an integrated power sys- tem model of unprecedented scale composed of the Western Electricity Coordination Council (WECC) transmission system with tens of thousands of distribution systems deployed with flexible device-level distributed energy resources (DERs) using off-the-shelf simulators.

Transactive energy, market-based controls, DER int↗

Spacetime pq theory for AC and DC electric power systems

The 50/60 Hz alternating current (AC) electric power has been the standard and most flexible energy source powering our modern societies for one and a half centuries since the war of the currents: AC versus direct current (DC). A reactive power concept that was introduced at the beginning of the AC power was very useful for circuit/system analysis, design, control, optimization, and ultimately for more efficient and stable generation, transmission, distribution, and consumption. The initial reactive power theory was based on single-phase sinusoidal AC power to capture inductive and capacitive power that yields to net-zero average power over one fundamental cycle. Soon it was expanded to non-sinusoidal AC power and finally to instantaneous three-phase AC power. However, these reactive power theories remain separate and limited to special cases and have never been consolidated and made valid to all cases. Today, more widespread adoption of power electronics and renewable energy is bringing back DC power into the electric grids. The reactive power concept has never been applied to DC power systems. There is no reactive power in DC power systems according to the existing reactive power theories. Do DC power systems really have no reactive power? Capacitors and inductors are widely used in DC just like in AC power systems. Are they not reactive power components? Why are they different from their AC counterparts? Furthermore, are batteries active or reactive power components? What about active devices like power converters (or inverters) with AC (or DC) on one side and DC (or AC) on the other? Do they generate or consume reactive power? Finally, what about AC and DC hybrid power systems? How to define reactive power in such a complex power system that has a multitude of loads, buses, and sources? Is there reactive power between any two loads, any two buses, or any two sources in a power system and what is the total reactive power in such a complex power system as a whole? As the motivation and goal of this paper to answer the above basic questions, to unify the existing AC reactive power theories and to ultimately provide theoretical and insightful guidance for system analysis, design, control, efficiency, optimization, and operation of complex power systems, a concept of spacetime (both spatial and temporal) active and reactive power (pq) theory—the spatiotemporal aspect of active and reactive power—is developed for both AC and DC power systems. The theoretical definitions and physical meanings of the spacetime reactive power will be developed, and real applications and thought experiments/cases/exercises will be explored and discussed. The developed mathematics to define the active (or real) and reactive (or imaginary) power— p and q respectively by dot (scalar) and cross (vector) products of multi-dimension spacetime vectors and time-space mapping principle/law can have some fundamental implications as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SAS4A/SASSYS-1 Validation with EBR-II Tests Performed During the SHRT Testing Program

The EBR-II sodium-cooled fast reactor supported a wide range of fast reactor research activities. The final fifteen years of operations at EBR-II were used for experiments and tests to demonstrate the importance of passive safety in liquid metal reactors and the capability of such systems to provide strong passive responses during off-normal conditions. The Shutdown Heat Removal Test program at EBR-II provided test data supporting the validation of computer codes for design, licensing, and operation of LMRs, among other objectives. The program included nearly sixty tests, most of which were protected and unprotected loss of flow and loss of heat sink tests run at various initial powers and flow rates. This report documents the results of modeling and simulation of tests from the Shutdown Heat Removal Test program to support validation of Argonne’s SAS4A/SASSYS-1 fast reactor safety analysis code. SHRT-17 was a protected loss of flow test where a loss of electrical power to all sodium coolant pumps was simulated to demonstrate the effectiveness of natural circulation cooling characteristics. SHRT-45R was an unprotected loss of flow test where the control rod scram function of the plant protection system was disabled to demonstrate the effectiveness of EBR-II’s passive reactivity feedbacks. BOP-301 and BOP-302R were unprotected loss of heat sink tests that demonstrated how reactivity feedback effects driven by changes to the core inlet temperature can shut down the fission process. This validation activity leverages modeling and simulation efforts that originated under an International Atomic Energy Agency Coordinated Research Project for benchmark analysis of the EBR-II Shutdown Heat Removal Tests. The SAS4A/SASSYS-1 models originally developed for the CRP have been modernized to utilize new code features and modeling practices. Differences between the predicted and measured test data were explored and the causes of these differences were identified as being due to modeling approximations, uncertainty in transient component behavior, and instrumentation uncertainties. Overall, it was concluded that for SHRT-17, SHRT-45R, BOP-301, and BOP-302R there was good agreement between the flow, power, and temperature predictions and the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Microgrid Energy Management System Integration with Advanced Distribution Management System

The Integrated Distribution Management System (IDMS) project was initiated to demonstrate the interactive operation of microgrid systems and the distribution systems with which they interconnect. The key technologies for this are the microgrid management system and the utility distribution management system. The IDMS project successfully demonstrated that a utility’s advanced distribution management system/distributed energy resources management system (ADMS/DERMS) could effectively manage microgrids to provide visibility and control functionalities as well as use the microgrid as a dispatchable resource to support the utility grid. The DERMS accomplishes this by determining active and reactive power needs at the point of common coupling (PCC) using advanced applications like volt/VAR watt optimization (VVWO) and load relief (LR) with the underlying core applications state estimation (SE) and load flow (LF). The ADMS/DERMS can use the microgrid as a resource to resolve and prevent violations in the grid and to optimize the operational working state of the grid. The IDMS project demonstrated that a utility-operated ADMS with embedded DERMS functionality can flexibly manage a variety of microgrids and other aggregated distributed energy resources (DER) in concert with the wider distribution grid. Microgrids can provide grid services in any number of different ways to meet the operational needs of the distribution utility. The manner of aggregation — microgrid or virtual power plant — is not necessarily relevant to the utility as long as the grid services from the aggregated DER are available and can be managed by its ADMS/DERMS for the stability and reliability of the grid. The IDMS project demonstrated this integrated ADMS concept by combining hardware/software-in-the-loop testing with commercial products from different vendors and a utility’s network model. The project integrated the Schneider Electric EcoStruxure™ ADMS with DERMS with the Schweitzer Engineering Laboratories (SEL) POWERMAX ® Microgrid Control System, and the simulated resources with energy company PECO’s model of a utility-owned microgrid, establishing an operational relationship in which the utility manages the operational functionality of a microgrid at the PCC and that provides the utility with the capability to control the comprehensive power system, inclusive of the macrogrid and microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear Model Predictive Control Based on Real-Time Iteration Scheme for Wave Energy Converters Using WEC-Sim

One of several challenges that wave energy technologies face is their inability to generate electricity cost-competitively with other grid-scale energy generation sources. Several studies have identified two approaches to lower the levelised cost of electricity: reduce the cost over the device's lifetime or increase its overall electrical energy production. Several advanced control strategies have been developed to address the latter. However, only a few take into account the overall efficiency of the power take-off (PTO) system, and none of them solve the optimisation problem that arises at each sampling time on real-time. In this paper, a detailed Nonlinear model predictive control (NMPC) approach based on the real-time iteration (RTI) scheme is presented, and the controller performance is evaluated using a time-domain hydrodynamics model (WEC-Sim). The proposed control law incorporates the PTO system's efficiency in a control law to maximise the energy extracted. The study also revealed that RTI-NMPC clearly outperforms a simple resistive controller.

model predictive control↗

Wind and Solar Hybrid Power Plants for Energy Resilience

Wind-solar-storage hybrid power plants represent a significant and growing share of new proposed projects in the United States (U.S.). Their uptake is supported by increasing renewable energy market share, technical abilities for dispatch and control, and decreasing wind, solar, and battery storage costs. Simultaneously, generation and storage resources are increasingly used in distributed power systems. While concerns around the reliability of the aging, transforming U.S. electric grid are growing, diversifying energy resources through hybridization or spatial distribution provides an opportunity to enhance power system resilience compared to single-source generation. Understanding where to build hybrids for resilience value, rather than bulk power supply, has not been fully explored in previous studies. Therefore, in this study, we complete a national complementarity analysis to identify areas in the U.S. that are particularly suited for wind-solar hybrid power plant development. We show the importance of seasonal and diurnal patterns in assessing complementarity, and identify that regions in the Great Plains, Midwest, and Southeast are particularly suited for hybrid power plants. We demonstrate the resilience value of hybridization for a reference system based near Memphis, Tennessee, and show optimal sizing of wind, solar, and storage assets given 1.0 and 0.9 critical load factors. Results indicate that pairing wind and solar assets better meet constant load demand and reduce storage requirements compared to solar alone. These results enable future work integrating complementarity metrics in resilience frameworks and indicate a need for more finer resolution of local resource, demand, and hazard data.

14 SOLAR ENERGY↗

Nonlinear Model Predictive Control Based on Real-Time Iteration Scheme for Wave Energy Converters Using WEC-Sim: Preprint

One of several challenges that wave energy technologies face is their inability to generate electricity cost-competitively with other grid-scale energy generation sources. Several studies have identified two approaches to lower the levelised cost of electricity: reduce the cost over the device's lifetime or increase its overall electrical energy production. Several advanced control strategies have been developed to address the latter. However, only a few take into account the overall efficiency of the power take-off (PTO) system, and none of them solve the optimisation problem that arises at each sampling time on real-time. In this paper, a detailed Nonlinear model predictive control (NMPC) approach based on the real-time iteration (RTI) scheme is presented, and the controller performance is evaluated using a time-domain hydrodynamics model (WEC-Sim). The proposed control law incorporates the PTO system's efficiency in a control law to maximise the energy extracted. The study also revealed that RTI-NMPC clearly outperforms a simple resistive controller.

model predictive control↗

GATE Center of Excellence in Innovative Drivetrains in Electric Automotive Technology Education (IDEATE) (Final Report)

The IDEATE project recognized that this is a critical point in history where advanced engineering solutions are required to propel the U.S. automotive industry irrevocably to the next level: the electrified drivetrain. The existing workforce is not sufficient to this task. It is imperative that automotive engineers with traditional backgrounds focused on internal-combustion and mechanical-drivetrain technologies be retrained with the most current advanced solutions in battery controls and vehicle power electronics. For the long-term success of the U.S. automakers, it is even more important that a future workforce be developed that has both broad and deep comprehension of the issues involved and the most advanced solutions known to these problems. Two campuses of the University of Colorado system joined forces to establish the GATE Center of Excellence in Innovative Drivetrains in Electric Automotive Technology Education (IDEATE). The University of Colorado Boulder (CU-Boulder) is widely regarded as having one of the top graduate programs in power electronics in the country; the University of Colorado Colorado Springs (UCCS) has unrivaled expertise in algorithms for automotive battery control. By collaborating, IDEATE built on our team’s proven strengths to develop innovative curricula and to initiate courses and programs that have provided (and continue to provide) students with a unique opportunity for holistic and specialty education in electric drivetrain technology (part-way through the project, we invited Utah State University to join the project, adding to our strength in power electronics for battery application).

42 ENGINEERING↗

Residential Vehicle-to-Home Backup Power Capabilities: Key Findings from a ComEd Beneficial Electrification R&D Pilot

This report summarizes key findings from a collaborative technical study of residential, non-grid-tied vehicle-to-home (V2H) backup power systems in Commonwealth Edison’s (ComEd’s) service territory. The work integrates (1) a feeder-level technoeconomic analysis (TEA) using historical outage-event data and simulated electric-vehicle (EV) driving/charging profiles to estimate potential reliability and customer interruption-cost impacts under V2H and vehicle-to-grid (V2G) adoption scenarios; (2) controlled laboratory performance testing of a representative V2H backup ecosystem to characterize transfer-to-backup behavior, sustained power delivery, efficiency trends, and repeatable reliability limitations; and (3) a cybersecurity assessment aligned with NIST Cybersecurity Framework (CSF) 2.0 and ISO/SAE 21434 to evaluate interface-level risk drivers and identify program-relevant mitigations. Results indicate that V2H can provide measurable resilience value, but outcomes are strongly context dependent on outage patterns and the share of events that are “V2H-applicable.” Typical transfer-to-backup behavior clustered on the order of minutes, but rare long-delay edge cases were observed (including an event approaching 30 minutes) and should be treated as a reliability risk. High-power testing showed that peak-rated output is not necessarily continuously deliverable; stable operation may require operation below nameplate ratings and attention to thermal and installation constraints. The cybersecurity assessment highlights a broad attack surface spanning commissioning, home networks, embedded services, and cloud/OTA pathways, motivating minimum controls for secure onboarding, signed updates, patch cadence, and coordinated vulnerability response for any scaled deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗