Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data reduction methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Changes in active-site geometry on X-ray photoreduction of a lytic polysaccharide monooxygenase active-site copper and saccharide binding

The recently discovered lytic polysaccharide monooxygenases (LPMOs) are Cu-containing enzymes capable of degrading polysaccharide substrates oxidatively. The generally accepted first step in the LPMO reaction is the reduction of the active-site metal ion from Cu 2+ to Cu + . Here we have used a systematic diffraction data collection method to monitor structural changes in two AA9 LPMOs, one from Lentinus similis (LsAA9_A) and one from Thermoascus auranti­acus (TaAA9_A), as the active-site Cu is photoreduced in the X-ray beam. For LsAA9_A, the protein produced in two different recombinant systems was crystallized to probe the effect of post-translational modifications and different crystallization conditions on the active site and metal photoreduction. We can recommend that crystallographic studies of AA9 LPMOs wishing to address the Cu 2+ form use a total X-ray dose below 3 × 10 4 Gy, while the Cu + form can be attained using 1 × 10 6 Gy. In all cases, we observe the transition from a hexa­coordinated Cu site with two solvent-facing ligands to a T-shaped geometry with no exogenous ligands, and a clear increase of the θ 2 parameter and a decrease of the θ 3 parameter by averages of 9.2° and 8.4°, respectively, but also a slight increase in θ T . Thus, the θ 2 and θ 3 parameters are helpful diagnostics for the oxidation state of the metal in a His-brace protein. On binding of cello-oligosaccharides to LsAA9_A, regardless of the production source, the θ T parameter increases, making the Cu site less planar, while the active-site Tyr—Cu distance decreases reproducibly for the Cu 2+ form. Thus, the θ T increase found on copper reduction may bring LsAA9_A closer to an oligosaccharide-bound state and contribute to the observed higher affinity of reduced LsAA9_A for cellulosic substrates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cone-beam breast computed tomography with a displaced flat panel detector array

Purpose: In cone-beam computed tomography (CBCT), and in particular in cone-beam breast computed tomography (CBBCT), an important issue is the reduction of the image artifacts produced by photon scatter and the reduction of patient dose. In this work, the authors propose to apply the detector displacement technique (also known as asymmetric detector or ''extended view'' geometry) to approach this goal. Potentially, this type of geometry, and the accompanying use of a beam collimator to mask the unirradiated half-object in each projection, permits some reduction of radiation dose with respect to conventional CBBCT and a sizeable reduction of the overall amount of scatter in the object, for a fixed contrast-to-noise ratio (CNR). Methods: The authors consider a scan configuration in which the projection data are acquired from an asymmetrically positioned detector that covers only one half of the scan field of view. Monte Carlo simulations and measurements, with their CBBCT laboratory scanner, were performed using PMMA phantoms of cylindrical (70-mm diameter) and hemiellipsoidal (140-mm diameter) shape simulating the average pendant breast, at 80 kVp. Image quality was evaluated in terms of contrast, noise, CNR, contrast-to-noise ratio per unit of dose (CNRD), and spatial resolution as width of line spread function for high contrast details. Results: Reconstructed images with the asymmetric detector technique deviate less than 1% from reconstruction with a conventional symmetric detector (detector view) and indicate a reduction of the cupping artifact in CT slices. The maximum scatter-to-primary ratio at the center of the phantom decreases by about 50% for both small and large diameter phantoms (e.g., from 0.75 in detector view to 0.40 in extended view geometry at the central axis of the 140-mm diameter PMMA phantom). Less cupping produces an increase of the CT number accuracy and an improved image detail contrast, but the associated increase of noise observed may produce a decrease of detail CNR. By simulating the energy deposited inside the phantoms, the authors evaluated a maximum 50% reduction of the absorbed dose at the expense of a decrease of CNR, for the half beam irradiation of the object performed with the displaced detector technique with respect to full beam irradiation. The decrease in CNR, and in absorbed dose as well, translates into a detail CNRD showing values comparable to or higher than the ones obtained for a conventional symmetric detector technique, attributed to the effect of decreased scatter in particular at the axis of the irradiated object. An estimate is provided (about 12%) for the average dose reduction possible in CBBCT at constant CNR for the average uncompressed breast (14 cm diameter, 50% glandularity), in case of minimum image overlapping in extended view. Conclusions: Simulations and experiments show that CBCT reconstructions with the displaced detector technique and with a half beam collimator are less affected by scatter artifacts, which could lead to some decrease of the radiation dose to the irradiated object with respect to a conventional reconstruction. This dose reduction is associated with increase of noise, decrease of CNR, but equal or improved CNRD values. The use of a small area detector would allow also to reduce the apparatus cost and to improve the data transfer speed with a corresponding increment of frame rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs

Purpose: Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However, conventional iterative reconstruction methods easily introduce new artifacts around metal implants because of incomplete data reconstruction and inconsistencies in practical data acquisition. Hence, this work aims at developing a method to suppress newly introduced artifacts and improve the image quality around metal implants for the iterative MAR scheme. Methods: The proposed method consists of two steps based on the general iterative MAR framework. An uncorrected image is initially reconstructed, and the corresponding metal trace is obtained. The iterative reconstruction method is then used to reconstruct images from the unaffected sinogram. In the reconstruction step of this work, an iterative strategy utilizing unmatched projector/backprojector pairs is used. A ramp filter is introduced into the back-projection procedure to restrain the inconsistency components in low frequencies and generate more reliable images of the regions around metals. Furthermore, a constrained total variation (TV) minimization model is also incorporated to enhance efficiency. The proposed strategy is implemented based on an iterative FBP and an alternating direction minimization (ADM) scheme, respectively. The developed algorithms are referred to as “iFBP-TV” and “TV-FADM,” respectively. Two projection-completion-based MAR methods and three iterative MAR methods are performed simultaneously for comparison. Results: The proposed method performs reasonably on both simulation and real CT-scanned datasets. This approach could reduce streak metal artifacts effectively and avoid the mentioned effects in the vicinity of the metals. The improvements are evaluated by inspecting regions of interest and by comparing the root-mean-square errors, normalized mean absolute distance, and universal quality index metrics of the images. Both iFBP-TV and TV-FADM methods outperform other counterparts in all cases. Unlike the conventional iterative methods, the proposed strategy utilizing unmatched projector/backprojector pairs shows excellent performance in detail preservation and prevention of the introduction of new artifacts. Conclusions: Qualitative and quantitative evaluations of experimental results indicate that the developed method outperforms classical MAR algorithms in suppressing streak artifacts and preserving the edge structural information of the object. In particular, structures lying close to metals can be gradually recovered because of the reduction of artifacts caused by inconsistency effects.

60 APPLIED LIFE SCIENCES↗

SnowPac : a multiscale cubic B-spline wavelet compressor for astronomical images

ABSTRACT As more advanced and complex survey telescopes are developed, the size and scale of data being captured grows at increasing rates. Across various domains, data compression through wavelets has enabled the reduction of data size and increase in computation efficiency. In this paper, we provide qualitative and quantitative tests of a new wavelet-based image compression method compared against the current standard for astronomical images. The analysis is improved by making use of state-of-the-art object detection systems to accurately measure the impact of the compression. We find that a combination of lossy wavelet-based methods, efficient quantization, and lossless dictionary compressors can preserve up to 98 per cent of astronomical objects at a 10:1 compression ratio. This significant reduction in file size also preserves astronomical object properties better than existing methods. These methods help further reduce future workloads for image-heavy processing pipelines.

Pulido, Jesus↗

Decoding the Pair Distribution Function of Uranium in Molten Fluoride Salts from X-Ray Absorption Spectroscopy Data by Machine Learning

Thermal properties of actinides in molten salts are linked to the strongly disordered local environment of actinide ions. Here, we illustrate both the limitations of the commonly used fitting method for analysis of extended X-ray absorption fine structure (EXAFS) spectra in molten UF 4 and a possible solution using an "objective neural network - EXAFS" (ONNE) method. ONNE provides both extraction of the pair distribution function, as validated by its application to the EXAFS spectra calculated on molecular dynamics trajectory, and the EXAFS data reconstruction. The ONNE analysis of the molten UF4 has revealed reduction of the first nearest neighbor U-F coordination number, expansion of the U-F bond length and smaller contribution to the second shell compared to its crystalline counterpart. This method is therefore an attractive alternative to conventional EXAFS analysis and molecular dynamics simulations for studies of disordered environment of actinides in molten salts.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Quantifying market volume sensitivity to material property modifications in polyhydroxybutyrate: A parametric analysis approach

Polyhydroxybutyrate (PHB), a biodegradable biopolymer, represents a promising alternative to petroleum-based thermoplastics. However, despite consistent market growth, PHB faces persistent commercialization challenges that limit widespread adoption. Existing research has focused predominantly on optimizing PHB production processes, leaving a critical gap in understanding which material property modifications would most effectively enhance market competitiveness. This study addresses this gap by systematically analyzing the relationship between polymer material properties and market performance using U.S. market data from 2008 to 2021 for 21 thermoplastic polymers across 19 material properties. We employed principal component regression to identify property modifications that could maximize market volume while reducing CO 2 emissions. Our parametric analysis revealed that two specific material properties – Hardness Shore A and Sheet Extrusion Temperature – significantly influence PHB marketability across different price points. Market simulations demonstrated that a 10% increase in Hardness Shore A could increase PHB market volume by 431.5 million kg while reducing emissions by 188.7 kg CO 2 . A similar 10% increase to Sheet Extrusion Temperature could yield a 297.5 million kg volume increase and a 99.2 kg CO 2 reduction in emissions. Critically, this approach is agnostic to the specific methods required to achieve these property changes, instead providing material scientists with quantitative, data-driven targets for R&D prioritization. Here, this framework offers a novel methodology for evaluating biopolymer competitiveness and supporting strategic decisions to accelerate PHB market adoption and contribute to decarbonization of the plastics industry.

09 BIOMASS FUELS↗

Incorporating residential AC load control into ancillary service markets: Measurement and settlement

Many pre-existing air conditioner load control programs can provide valuable operational flexibility but have not been incorporated into electricity ancillary service markets or grid operations. Multiple demonstrations have shown that residential air conditioner (AC) response can deliver resources quickly and can provide contingency reserves. A key policy hurdle to be overcome before AC load control can be fully incorporated into markets is how to balance the accuracy, cost, and complexity of methods available for the settlement of load curtailment. Overcoming this hurdle requires a means for assessing the accuracy of shorter-term AC load control demand reduction estimation approaches in an unbiased manner. This paper applies such a method to compare the accuracy of approaches varying in cost and complexity ? including regression analysis, load matching and control group approaches ? using feeder data, household data and AC end-use data. We recommend a practical approach for settlement, relying on an annually updated set of tables, with pre-calculated reduction estimates. These tables allow users to look up the demand reduction per device based on daily maximum temperature, geographic region and hour of day, simplifying settlement and providing a solution to the policy problem presented in this paper.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effect of Carbon Deposition on the Oxidation Rate of Copper/Bentonite in the Chemical Looping Process

The presented work is part of the Industrial Carbon Management Initiative (ICMI) on the development of metal oxide oxygen carriers for use in the chemical looping combustion process. An oxygen carrier, CuO/bentonite (60:40%), was reacted with methane gas and then oxidized in air. The change in weight and reaction gas concentrations were measured using a thermogravimetric analyzer (TGA) equipped with a real-time gas analyzer. The reduction–oxidation cycle was conducted within the temperature range of 750–900 °C for 10 cycles, using 20, 50, and100% CH{sub 4} concentrations in N{sub 2} for the reduction segment and dry air for the oxidation segment. Several analysis methods were evaluated to fit the oxidation of reduced CuO (i.e., Cu) data over the complete conversion range with suitable rate expressions derived from existing models for oxidation, including the shrinking core model (diffusion and reaction control), first- and second-order reaction rates, parallel and series reaction mechanisms, and Johnson–Mehl–Avrami (JMA) rate. The best agreement between the experimental data and the models of the Cu oxidation was accomplished using the JMA model. The reactivity of the oxygen carrier during the oxidation reactions was affected by the CH{sub 4} concentration as well as the temperature. The rate of fractional uptake of oxygen onto the carrier decreased as the temperature increased, contrary to expectations and indicative that the mechanism is changing during the test. Analysis of the exit gas provided evidence of carbon deposition on the reduced sorbent particle and resulted in the CO{sub 2} product upon oxidation. The oxidation of this carbon releases significant heat that is capable of changing the particle morphology (Zhu, Y.; Mimura, K.; Isshiki, M. Oxid. Met. 2004, 62, 207-222). On the basis of experimental results, the overall reaction process in the fuel reactor may be considered to consist of the decomposition of CH{sub 4} into C and H{sub 2} and reduction of CuO/bentonite by the resulting H{sub 2} and the parallel reaction of CH{sub 4} with CuO/bentonite. The extent of carbon deposition in the carrier particle increased with an increasing temperature and CH{sub 4} concentration. This deposited carbon not only leads to CO{sub 2} release from the oxidation reactor but, more importantly, causes degredation of the carrier capacity and its reactivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functional Data Analysis Applied to Modeling of Severe Acute Mucositis and Dysphagia Resulting From Head and Neck Radiation Therapy

Purpose: Current normal tissue complication probability modeling using logistic regression suffers from bias and high uncertainty in the presence of highly correlated radiation therapy (RT) dose data. This hinders robust estimates of dose-response associations and, hence, optimal normal tissue–sparing strategies from being elucidated. Using functional data analysis (FDA) to reduce the dimensionality of the dose data could overcome this limitation. Methods and Materials: FDA was applied to modeling of severe acute mucositis and dysphagia resulting from head and neck RT. Functional partial least squares regression (FPLS) and functional principal component analysis were used for dimensionality reduction of the dose-volume histogram data. The reduced dose data were input into functional logistic regression models (functional partial least squares–logistic regression [FPLS-LR] and functional principal component–logistic regression [FPC-LR]) along with clinical data. This approach was compared with penalized logistic regression (PLR) in terms of predictive performance and the significance of treatment covariate–response associations, assessed using bootstrapping. Results: The area under the receiver operating characteristic curve for the PLR, FPC-LR, and FPLS-LR models was 0.65, 0.69, and 0.67, respectively, for mucositis (internal validation) and 0.81, 0.83, and 0.83, respectively, for dysphagia (external validation). The calibration slopes/intercepts for the PLR, FPC-LR, and FPLS-LR models were 1.6/−0.67, 0.45/0.47, and 0.40/0.49, respectively, for mucositis (internal validation) and 2.5/−0.96, 0.79/−0.04, and 0.79/0.00, respectively, for dysphagia (external validation). The bootstrapped odds ratios indicated significant associations between RT dose and severe toxicity in the mucositis and dysphagia FDA models. Cisplatin was significantly associated with severe dysphagia in the FDA models. None of the covariates was significantly associated with severe toxicity in the PLR models. Dose levels greater than approximately 1.0 Gy/fraction were most strongly associated with severe acute mucositis and dysphagia in the FDA models. Conclusions: FPLS and functional principal component analysis marginally improved predictive performance compared with PLR and provided robust dose-response associations. FDA is recommended for use in normal tissue complication probability modeling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combining Deep Learning and scatterControl for High-Throughput X-ray CT Based Non-Destructive Characterization of Large-Scale Casted Metallic Components

X-ray computed tomography (XCT) is essential for nondestructive evaluation and quality control of large-scale metal components. XCT imaging, however, faces significant challenges from metal artifacts, particularly those caused by Compton scattering, which degrade image quality and obscure critical details. Hardware-based solutions (e.g. scatterControl) offer advancements by intercepting scattered photons and reducing artifacts, but they can be time-consuming and require additional processing. Here, we propose modifying and leveraging a novel deep learning (DL) framework, Simurgh, to enhance and accelerate scatter correction in XCT. By combining scatterControl with DL-based artifact removal, we demonstrate significant reduction in scan time while producing high-quality reconstructions. Through extensive evaluation on industrial XCT data, we show that our methods reduce scan time by up to more than 10 x while preserving flaw detectability. Quantitative analysis across multiple segmentation techniques confirms that Simurgh-based reconstructions consistently outperform traditional Feldkamp-Davis-Kress, model-based iterative reconstruction, and commercial DL models in both pixel-level and task-specific evaluations, enabling scalable, high-throughput XCT workflows for characterization of large scale components in applications such as casting and metal additive manufacturing.

Complex metal parts↗

Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose distributions were clinically identical. In all patient cases, radiation oncologists rated O-MAR corrected images as higher quality. Formerly obscured critical structures were able to be visualized. The overall image quality and the conspicuity in critical organs were significantly improved compared with the uncorrected images: overall quality score (1.35 vs 3.25, P= 0.0022); bladder (2.15 vs 3.7, P= 0.0023); prostate and seminal vesicles/vagina (1.3 vs 3.275, P= 0.0020); rectum (2.8 vs 3.9, P= 0.0021). The noise levels of the selected ROIs were reduced from 93.7 to 38.2 HU. On most cases (8/10), the average CT Hounsfield numbers of the prostate/vagina on the O-MAR corrected images were closer to the referenced value (41.2 HU, an average measured from patients without metal implants) than those on the uncorrected images. High {gamma} pass rates of the five IMRT dose distribution pairs indicated that the dose distributions were not significantly affected by the CT image improvements. Conclusions: Overall, this study indicated that the O-MAR function can remarkably reduce metal artifacts and improve both CT Hounsfield number accuracy and target and critical structure visualization. Although there was no significant impact of the O-MAR algorithm on the calculated dose distributions, we suggest that O-MAR corrected images are more suitable for the entire treatment planning process by offering better anatomical structure visualization, improving radiation oncologists' confidence in target delineation, and by avoiding subjective density overrides of artifact regions on uncorrected images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modeling, Analysis, and Control of Demand Response Resources

While the traditional goal of an electric power system has been to control supply to fulfill demand, the demand-side can plan an active role in power systems via Demand Response (DR), defined by the Department of Energy (DOE) as “a tariff or program established to motivate changes in electric use by end-use customers in response to changes in the price of electricity over time, or to give incentive payments designed to induce lower electricity use at times of high market prices or when grid reliability is jeopardized” [29]. DR can provide a variety of benefits including reducing peak electric loads when the power system is stressed and fast timescale energy balancing. Therefore, DR can improve grid reliability and reduce wholesale energy prices and their volatility. This dissertation focuses on analyzing both recent and emerging DR paradigms. Recent DR programs have focused on peak load reduction in commercial buildings and industrial facilities (C&I facilities). We present methods for using 15-minute-interval electric load data, commonly available from C&I facilities, to help building managers understand building energy consumption and ‘ask the right questions’ to discover opportunities for DR. Additionally, we present a regression-based model of whole building electric load, i.e., a baseline model, which allows us to quantify DR performance. We use this baseline model to understand the performance of 38 C&I facilities participating in an automated dynamic pricing DR program in California. In this program, facilities are expected to exhibit the same response each DR event. We find that baseline model error makes it difficult to precisely quantify changes in electricity consumption and understand if C&I facilities exhibit event-to-event variability in their response to DR signals. Therefore, we present a method to compute baseline model error and a metric to determine how much observed DR variability results from baseline model error rather than real variability in response. We find that, in general, baseline model error is large. Though some facilities exhibit real DR variability, most observed variability results from baseline model error. In some cases, however, aggregations of C&I facilities exhibit real DR variability, which could create challenges for power system operation. These results have implications for DR program design and deployment. Emerging DR paradigms focus on faster timescale DR. Here, we investigate methods to coordinate aggregations of residential thermostatically controlled loads (TCLs), including air conditioners and refrigerators, to manage frequency and energy imbalances in power systems. We focus on opportunities to centrally control loads with high accuracy but low requirements for sensing and communications infrastructure. Specifically, we compare cases when measured load state information (e.g., power consumption and temperature) is 1) available in real time; 2) available, but not in real time; and 3) not available. We develop Markov Chain models to describe the temperature state evolution of heterogeneous populations of TCLs, and use Kalman filtering for both state and joint parameter/state estimation. We present a look-ahead proportional controller to broadcast control signals to all TCLs, which always remain in their temperature dead-band. Simulations indicate that it is possible to achieve power tracking RMS errors in the range of 0.26–9.3% of steady state aggregated power consumption. Results depend upon the information available for system identification, state estimation, and control. We find that, depending upon the performance required, TCLs may not need to provide state information to the central controller in real time or at all. We also estimate the size of the TCL potential resource; potential revenue from participation in markets; and break-even costs associated with deploying DR-enabling technologies. We find that current TCL energy storage capacity in California is 8–11 GWh, with refrigerators contributing the most. Annual revenues from participation in regulation vary from $10 to $220 per TCL per year depending upon the type of TCL and climate zone, while load following and arbitrage revenues are more modest at $2 to $35 per TCL per year. These results lead to a number of policy recommendations that will make it easier to engage residential loads in fast timescale DR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of FSP Reactor Design with Sensitivity Studies of Beryllium-Reflected Critical Assemblies

The baseline design for space nuclear power is a fission surface power (FSP) system: sodium-potassium (NaK) cooled, fast spectrum reactor with highly-enriched-uranium (HEU)-O 2 fuel, stainless steel (SS) cladding, and beryllium reflectors with B4C control drums. Previous studies were performed to evaluate modeling capabilities and quantify uncertainties and biases associated with analysis methods and nuclear data. Comparison of Zero Power Plutonium Reactor (ZPPR)-20 benchmark experiments with the FSP design indicated that further reduction of the total design model uncertainty requires the reduction in uncertainties pertaining to beryllium and uranium cross-section data. Further comparison with three beryllium-reflected HEU-metal benchmark experiments performed at the Oak Ridge Critical Experiments Facility (ORCEF) concluded the requirement that experimental validation data have similar cross section sensitivities to those found in the FSP design. A series of critical experiments was performed at ORCEF in the 1960s to support the Medium Power Reactor Experiment (MPRE) space reactor design. The small, compact critical assembly (SCCA) experiments were graphite- or beryllium-reflected assemblies of SS-clad, HEU-O 2 fuel on a vertical lift machine. All five configurations were evaluated as benchmarks. Two of the five configurations were beryllium reflected, and further evaluated using the sensitivity and uncertainty analysis capabilities of SCALE 6.1. Validation of the example FSP design model was successful in reducing the primary uncertainty constituent, the Be(n,n) reaction, from 0.28 %$\delta$k/k to 0.0004 %$\delta$k/k. Further assessment of additional reactor physics measurements performed on the SCCA experiments may serve to further validate FSP design and operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Big-Data Multi-Energy Iterative Volumetric Reconstruction Methods for As-Built Validation & Verification Applications

This document archives the results developed by the Lab Directed Research and Development (LDRD) project sponsored by Sandia National Laboratories (SNL). In this work, it is shown that SNL has developed the first known high-energy hyperspectral computed tomography system for industrial and security applications. The main results gained from this work include dramatic beam-hardening artifact reduction by using the hyperspectral reconstruction as a bandpass filter without the need for any other computation or pre-processing; additionally, this work demonstrated the ability to use supervised and unsupervised learning methods on the hyperspectral reconstruction data for the application of materials characterization and identification which is not possible using traditional computed tomography systems or approaches.

47 OTHER INSTRUMENTATION↗

SU-E-I-73: Clinical Evaluation of CT Image Reconstructed Using Interior Tomography

Purpose: Radiation dose reduction has been a long standing challenge in CT imaging of obese patients. Recent advances in interior tomography (reconstruction of an interior region of interest (ROI) from line integrals associated with only paths through the ROI) promise to achieve significant radiation dose reduction without compromising image quality. This study is to investigate the application of this technique in CT imaging through evaluating imaging quality reconstructed from patient data. Methods: Projection data were directly obtained from patients who had CT examinations in a Dual Source CT scanner (DSCT). Two detectors in a DSCT acquired projection data simultaneously. One detector provided projection data for full field of view (FOV, 50 cm) while another detectors provided truncated projection data for a FOV of 26 cm. Full FOV CT images were reconstructed using both filtered back projection and iterative algorithm; while interior tomography algorithm was implemented to reconstruct ROI images. For comparison reason, FBP was also used to reconstruct ROI images. Reconstructed CT images were evaluated by radiologists and compared with images from CT scanner. Results: The results show that the reconstructed ROI image was in excellent agreement with the truth inside the ROI, obtained from images from CT scanner, and the detailed features in the ROI were quantitatively accurate. Radiologists evaluation shows that CT images reconstructed with interior tomography met diagnosis requirements. Radiation dose may be reduced up to 50% using interior tomography, depending on patient size. Conclusion: This study shows that interior tomography can be readily employed in CT imaging for radiation dose reduction. It may be especially useful in imaging obese patients, whose subcutaneous tissue is less clinically relevant but may significantly increase radiation dose.

60 APPLIED LIFE SCIENCES↗

Operator inference for non-intrusive model reduction of systems with non-polynomial nonlinear terms

Here in this work we present a non-intrusive model reduction method to learn low-dimensional models of dynamical systems with non-polynomial nonlinear terms that are spatially local and that are given in analytic form. In contrast to state-of-the-art model reduction methods that are intrusive and thus require full knowledge of the governing equations and the operators of a full model of the discretized dynamical system, the proposed approach requires only the non-polynomial terms in analytic form and learns the rest of the dynamics from snapshots computed with a potentially black-box full-model solver. The proposed method learns operators for the linear and polynomially nonlinear dynamics via a least-squares problem, where the given non-polynomial terms are incorporated on the right-hand side. The least-squares problem is linear and thus can be solved efficiently in practice. The proposed method is demonstrated on three problems governed by partial differential equations, namely the diffusion–reaction Chafee–Infante model, a tubular reactor model for reactive flows, and a batch-chromatography model that describes a chemical separation process. The numerical results provide evidence that the proposed approach learns reduced models that achieve comparable accuracy as models constructed with state-of-the-art intrusive model reduction methods that require full knowledge of the governing equations.

42 ENGINEERING↗

Machine learning for nonintrusive model order reduction of the parametric inviscid transonic flow past an airfoil

Fluid flow in the transonic regime finds relevance in aerospace engineering, particularly in the design of commercial air transportation vehicles. Computational fluid dynamics models of transonic flow for aerospace applications are computationally expensive to solve because of the high degrees of freedom as well as the coupled nature of the conservation laws. While these issues pose a bottleneck for the use of such models in aerospace design, computational costs can be significantly minimized by constructing special, structure-preserving surrogate models called reduced-order models. In this work, we propose a machine learning method to construct reduced-order models via deep neural networks and we demonstrate its ability to preserve accuracy with a significantly lower computational cost. In addition, our machine learning methodology is physics-informed and constrained through the utilization of an interpretable encoding by way of proper orthogonal decomposition. Application to the inviscid transonic flow past the RAE2822 airfoil under varying freestream Mach numbers and angles of attack, as well as airfoil shape parameters with a deforming mesh, shows that the proposed approach adapts to high-dimensional parameter variation well. Notably, the proposed framework precludes the knowledge of numerical operators utilized in the data generation phase, thereby demonstrating its potential utility in the fast exploration of design space for diverse engineering applications. Comparison against a projection-based nonintrusive model order reduction method demonstrates that the proposed approach produces comparable accuracy and yet is orders of magnitude computationally cheap to evaluate, despite being agnostic to the physics of the problem.

97 MATHEMATICS AND COMPUTING↗

Lossy Data Compression Effects on Wall-bounded Turbulence: Bounds on Data Reduction

Postprocessing and storage of large data sets represent one of the main computational bottlenecks in computational fluid dynamics. We assume that the accuracy necessary for computation is higher than needed for postprocessing. Therefore, in the current work we assess thresholds for data reduction as required by the most common data analysis tools used in the study of fluid flow phenomena, specifically wall-bounded turbulence. These thresholds are imposed a priori by the user in L 2 -norm, and we assess a set of parameters to identify the minimum accuracy requirements. The method considered in the present work is the discrete Legendre transform (DLT), which we evaluate in the computation of turbulence statistics, spectral analysis and resilience for cases highly-sensitive to the initial conditions. Maximum acceptable compression ratios of the original data have been found to be around 97%, depending on the application purpose. Furthermore, the new method outperforms downsampling, as well as the previously explored data truncation method based on discrete Chebyshev transform (DCT).

97 MATHEMATICS AND COMPUTING↗