Search NASA⌕ Search

SEARCH · Search NASA

Results for “Engineering - Other instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

NucD-23 Nuclear Diagnostics Development: The future of neutron imaging and gamma reaction history

The Neutron Imaging team has deployed novel, active detection systems along two lines of sight at NIF. Studies aimed to characterize NIS sensitivity to implosion shape will be carried out to further extend reconstruction capabilities. Additionally, an improved camera timing system that will reduce uncertainties stemming from bang time jitter will also be fielded. The NIF GRH data recording system is more then 10 years old needs to be updated. Bandwidth and noise are a key limiting factor for improving data quality. New high bandwidth and low noise components will be tested at OMEGA in advance before fielding the components at NIF.

42 ENGINEERING↗

Fourth Generation MPDV and MBR at DARHT

A new experimental setup for diagnosing hydrotest performance was designed, built, and implemented at DARHT. The setup consists of 128 points of fourth generation (Gen4) multiplexed photonic Doppler velocimetry (MPDV) and 128 separate points of modulation based ranging (MBR) to serve as a direct complement to the MPDV. The diagnostics were designed to overcome limitations in the third generation of the MPDV diagnostic that limited laser launch power to ~10 mW per point. As the main failure mechanism identified in the third generation MPDV system arose from stimulated Brillouin scattering, a nonlinear optical phenomenon inherent in standard single mode fiber, the fourth generation MPDV system reduced the number of time-multiplexed channels by a factor of two. This has allowed laser launch power to be increased to as much as 200 mW per channel which is a 20 times increase in the signal to noise ratio (SNR) as compared with the third generation system. This document will first discuss the previous limitations and describe the design of the system. This will be followed by the results of a simple flyer plate experiment used to demonstrate the improved SNR as well as calibrate the phase errors in the system that MBR is sensitive to.

42 ENGINEERING↗

Chlorine Worth Study in Support of PF-4 Operations [Slides]

The primary concern of this study is if experiments can be designed/conducted to provide technical justification to NCS in order to increase mass limits. This goal is in direct support of 30 pits per year mission, one of the top priorities for NNSA. The accelerated timeline is as follows: Initial tasking, June 2020; preliminary design completion (CED-1 equivalent), November 2020; final design completion (CED-2 equivalent), March 2021; part receipt and inspection completion (CED-3a equivalent), October 2021; experiment execution (CED-3b equivalent), December 2021; experiment documentation write-up completion (start CED-4a equivalent), January 2022; and ICSBEP target (CED-4a equivalent), Fall 2022.

2019 ARCHIMEDES LDRD project↗

A Search for Sterile Neutrino Dark Matter (Final Report)

Decades of dark matter searches with increasingly higher sensitivity have so far not been able to detect the most-favored hypothetical dark matter particles. This has increased interest in sterile neutrinos with masses in the kilo-electronvolt (keV) range as possible dark matter candidates. We have established a and new and world-leading approach to search for keV-scale sterile neutrinos with superconducting radiation detectors. For this, we have implanted radioactive beryllium-7 (Be-7) nuclei into our superconducting tunnel junction (STJ) detectors and measured the recoil energy of the lithium-7 (Li-7) daughter nucleus with high accuracy. If the associated electron neutrino wave function contains some admixture of a keV sterile flavor, the Li-7 recoil energy will be shifted and produce an additional peak in the spectrum whose energy depends on the sterile neutrino mass. While we have not observed any evidence for sterile neutrinos in these precision decay experiments, the experiment has increased the sensitivity of sterile neutrino searches by a factor of ~10 over competing approaches in the mass range from ~10 to ~800 keV. The next generation of STJ detectors that we have developed as part of this project will be able further increase the sensitivity of the sterile neutrino search by at least another two orders of magnitude.

42 ENGINEERING↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Dose Rate Irradiations of Enduray Vision System for Nuclear Inspections

Higher radiation-hardened video cameras are needed in the operation and remote handling of equipment in nuclear reactor inspection and refueling applications. Vega Wave Systems, Inc. has developed a radiation-hardened vision system for nuclear energy applications. This vision system has been developed under several small business innovative research programs (SBIRs) from the U.S. Department of Energy, and the previous GAIN voucher program at Argonne National Laboratory (ANL) was successful in demonstrating that a prototype of the camera is radiation-hard up to at least 525 kGy (5.25 × 106 rad, Si equivalent) at dose rates of 10 kGy/hr with no measurable degradation in image quality and no measurable radiation-induced noise (RIN). Vega Wave Systems has developed a new version of the camera with more than 3X the resolution using a new design and new components, and this new design requires radiation-hardness qualification for marketplace acceptance. The program described in this report provided high radiation-hardness testing of this redesigned high-resolution vision system using the Argonne Low-Energy Accelerator Facility (LEAF). This report presents the results of irradiation tests performed on Vega Wave System’s redesigned high resolution vision system at a dose rate of 9.3 kGy/hr and up to total doses of 1823 kGy. This was an accumulation of 197 hours of irradiation. The results were excellent, providing proof of the redesigned high-resolution vision system’s immunity to high levels of radiation.

42 ENGINEERING↗

Irradiation Behavior of Piezoelectric Materials for Nuclear Reactor Sensors

In-situ measurement of surface acoustic wave (SAW) resonators were used to characterize piezoelectric materials behavior in a nuclear reactor environment. Lithium niobate and aluminum nitride devices were tested up to 500°C temperature and 450 kW reactor power (1.9x10 12 n/cm 2 s). The resonant frequency responds to step changes in temperature and power. Materials’ response are inferred from the observed resonant frequency changes, in particular the kinetic behavior is used to determine mechanisms responsible for observed changes. The observed response is attributed to two mechanisms: temperature increase from gamma heating and accumulation of radiation-induced defects. Both of these mechanisms alter the physical properties of the piezoelectric materials, particularly the elastic constants. The demonstrated repeatability and reliability of SAW devices are attractive for sensor applications in extreme environments.

36 MATERIALS SCIENCE↗

Specification of EBR-II Laser Profilometry Data

All laser profilometry data stored in FIPD were originally measured using the element laser profilometer system in HFEF/N. The irradiated fuel elements or pins were scanned by a laser beam to measure the outer diameter with position mapping of the spacer wire. The normal operation and data collection were performed automatically with HFEF/N Data Acquisition and Process Control System (DAPCS). With the digital control system, measured laser profilometry data were recorded in digital form on magnetic tapes, different from the analog contact profilometry data recorded by strip-chart record sheets. Two documents contained most of the important details about laser profilometry measurements. The first one is the operational manual of the laser profilometer (title: Element laser profilometer (ELP) operation and maintenance manual, HFEF/N OMM 4329, DOC. NO. W0171-0149-ES-01). This manual provides: (1) description of laser profilometer including the functions of each component (transceiver, retroreflector, clamping guide, shielding enclosure, electronic controller, etc.); (2) step-by-step guidance for calibrations, operations and measurements; and (3) maintenance procedures and other details of the element laser profilometer. Since first issued on 12/1/1986, several revisions/changes of the manual were developed to update the measurement accuracies and other factors for the laser profilometer system. The second document is a publicly accessible conference article titled “the element laser profilometer system in HFEF/N.” This article summarizes important functions and parameters of the laser profilometer. The range of measurements and the uncertainties reported in the article were consistent with the values reported in the operational manual.

42 ENGINEERING↗

Demonstration of acoustic monitoring for structural health of microreactors: Through use of neural networks and resonant ultrasound spectroscopy

Nuclear microreactors prioritize modularity and portability and are intended to be a cost-effective technology for non-conventional nuclear markets. As such, the development of microreactors into a safe and feasible solution for energy security applications will necessitate the development of non-destructive technologies to monitor the integrity of inaccessible reactors components during operation. This demonstration applies linear and nonlinear acoustic techniques, in combination with machine learning, to detect and classify mechanical changes (stress and damage) in a test article which are broadly representative of potential operating challenges within a functioning microreactor. All necessary data has been collected for this demonstration, with minor experimental issues identified that can be addressed in follow-on work. Motivated by the expected conditions within a functioning microreactor, we have demonstrated our monitoring techniques on a core-block-like test article using an unstructured excitation source that approximates the noisy acoustic environment expected during reactor operation. At all stress states mechanically applied to the test article, a machine learning model using an artificial neural network was able to classify with 100% accuracy whether a 3D laser vibrometry point measurement was made on an intact or artificially defective test article. Further, model predictions about whether the defect interface was rough or smooth were 95% accurate, indicating the ability of acoustic techniques to recover defect characteristics. Resonant ultrasound spectroscopy (RUS) was also applied to the dataset to provide further quantitative insights about material properties. RUS analysis was ultimately hampered by several minor experimental and data issues, limiting results to certain cases for this demonstration. Last, analysis using nonlinear RUS exhibited sensitivity to changing levels of applied stresses for each intact and defective state. As presented in this demonstration, acoustic monitoring exhibits sensitivity to stress changes, which are of concern due to high thermal gradients expected during startup and operation. Further, our techniques distinguish between measurements made on intact and damaged test articles.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on ISR-1 High-Altitude Balloon Flight

To test small technologies at lower cost for space science applications, LANL has developed a small high altitude balloon payload that could, in the future, be regularly and inexpensively launched from LANL. A neutron detector, NEMO, was integrated to evaluate its performance in a space-like mixed-radiation environment and collect neutron data in the atmosphere. In collaboration with EES-14, a high-altitude balloon payload was launched from LANL Technical Area 51 on February 27, 2023 and April 17, 2023. For real-time geolocation, a SAM-M8Q M8 GNSS module was used to get position and time, and an Iridium RockBLOCK 9603 was used to communicate with the ground using the Iridium satellite fleet. These modules were all controlled using an Iteaduino Mega microcontroller board. Finally, a High Altitude Science Eagle Flight Computer with a temperature pressure sensor ran independently, writing data to an SD card. All of these modules were powered by a 5 mAh lithium polymer battery. The battery was attached to the bottom of the payload while the remaining electronics were embedded in the underside of the top of the payload. These modules were wired as seen in Figure 1-2. The Iteaduino Mega microcontroller board was programmed to use the RockBLOCK to send a message once every 10 minutes containing neutron and GPS data read off the NEMO and SAM M8Q, respectively. Once the message send attempt finished, the RockBLOCK would be slept for the rest of the 10 minute interval. The Eagle Flight Computer ran continuously throughout the flight, taking data every 6 seconds. The RockBLOCK message data was set up to be delivered from the Iridium satellite fleet to a website, where it was stored and parsed to create live maps and plots for analysis and balloon retrieval. The RockBLOCK message data was additionally configured to be sent to an email as a fail-safe. The payload was ground-tested successfully for over 50 hours, with multiple revisions occurring to best prepare for conditions at altitude and improve the software and firmware to fix any issues that cropped up with the data pipeline. Additional to the balloon payload, the flight had an attached iMet-4 radiosonde and Garmin T5 GPS Dog Collar. The radiosonde provided GPS and meteorological data. The T5 dog collar is used along with a Garmin Astro 430 to track the balloon at a range of up to 9 miles for retrieval. The balloon itself was initially a 1600 g meteorological balloon with an attached High Altitude Science parachute, both of which can be seen in Figure 1-3. After the first flight, the EES team swapped to a Rocketman parachute.

42 ENGINEERING↗

Flow Sensor Test Article (F-STAr) - Assembly and Water Testing Report

The Flow Sensor Test Article (F-STAr) is a new test article under development for the Mechanisms Engineering Test Loop (METL) facility at Argonne National Laboratory. F-STAr’s purpose is to provide sodium submersible, high flowrate testing capabilities for the development of sensors, components, fluid studies and more. This report will provide a status update on the assembly and initial qualification testing of F-STAr. All components have been manufactured and received. Some modifications to these components were made to support minor changes in the test article design. Additionally, the power distribution, and data acquisition and control enclosures were designed, completed, and tested along with the control system software. Furthermore, initial qualification testing was completed in water. Finally, the F-STAr submersible Electromagnetic Flowmeter (EMFM) was completed and calibrated in flowing sodium.

42 ENGINEERING↗

Photogrammetry: Develop methods for detecting deviations from expected geometry of components in a glovebox environment (Lawrence Livermore National Laboratory Aging and Lifetimes Program FY23, Milestone 8651, Grading Criterion #4)

Measurements in glovebox environments are challenging to conduct. Currently deployed techniques are time consuming and provide limited information. These limitations make current disposition and future assessments of products challenging. In FY23 we developed methods for detecting deviations of components in a glovebox environment that address these shortcomings by rapidly collecting information-dense measurements. Conducted tests demonstrate that camera pose (position and orientation) can be derived for images utilized in the photogrammetry process. This information, in conjunction with common image processing techniques, enables automated detection and size estimation of surface features. First, image processing is used to identify marks, or localized regions, that standout from the surrounding area. Then, the physical size of the region can be estimated because scale can be determined for photogrammetry images. Development of this methods shows that photogrammetry can identify measurable deviations from expected geometries. Although measurement error when using this technique through a glovebox window still needs to be reduced, this capability shows promise for eliminating or reducing the use of tedious manual measurements.

42 ENGINEERING↗

Development of a pixelated BaF 2 test bed for timing applications [Slides]

BaF 2 one of the fastest known scintillators, emitting at 195 & 220 nm with sub-nanosecond decay constant. Fast emission only comprises ~13% of total light. The goal is to develop a prototype BaF 2 detector system with a practical form factor and variable geometry, and characterize system performance for various timing applications.

42 ENGINEERING↗

Assessment of PHDS Fulcrum40h and Ortec Detective-X High Purity Germanium (HPGe) Detector System Performance

This report provides a summary of measurement results used to compare the performance of the PHDS Fulcrum40h and Ortec Detective-X High Purity Germanium (HPGe) detector systems. Specifically, the measurement data collected was used to assess each detector system for gamma efficiency and resolution, gamma angular response and efficiency for an in-situ surface distribution, neutron efficiency, gamma pulse-pileup response, and gamma to neutron crosstalk.

42 ENGINEERING↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Automated Mini-Tubular Ceramic Production (Final Design Review)

Researchers at Lawrence Livermore National Laboratory need a way to increase the rate of manufacturing of mini-tubular ceramics to be used in testing particulate air filters. This document outlines our process from researching and writing an initial scope of work all the way to fabricating and testing a final prototype. This journey takes us through the background research, ideation process and selection of a final design. We also detail the desired engineering specifications and our concept selection process. We dedicate a significant portion of this report to discussion of our final design. We delve into how it was manufactured as well as the tests we performed and its successes and failures. We also propose potential areas for further development and next steps for sponsors. Overall, this document provides the reader with a comprehensive understanding of our design process and results.

36 MATERIALS SCIENCE↗