Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault mechanics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

3D seismic imaging of a fracture damage zone controlling reservoir compartmentalization at the Raft River EGS using multi-azimuth walkaway VSP

Accurate imaging of steeply dipping fracture zones in crystalline enhanced geothermal systems (EGS) is critical for constraining permeability architecture and guiding stimulation design. However, such structures remain poorly resolved by conventional surface seismic methods. We present a fully three-dimensional (3D) elastic-waveform inversion-migration workflow applied to multi-azimuth walkaway vertical seismic profiling (VSP) data acquired in a deviated borehole at the Raft River EGS. The workflow integrates first-arrival traveltime tomography, multi-scale elastic waveform inversion (EWI), and elastic least-squares reverse-time migration (ELSRTM) to recover high-resolution compressional-and shear-wave velocity models and to image structural discontinuities in the crystalline basement. The results reveal a laterally continuous low-velocity anomaly, with shear-wave velocity reductions of 25-30%, consistent with fractureinduced mechanical weakening. Two steeply dipping discontinuities bound a 50-80 m wide fracture damage zone. Independent constraints from microseismic clustering and geochemical compartmentalization corroborate the geometry and structural significance of this feature. Synthetic modeling further confirms that structures of this scale are resolvable (~30 m). These findings indicate that the Narrows structure is a distributed fracture damage zone rather than a discrete fault plane. By resolving fracture-zone geometry at the tens-of-meters scale using a single borehole, this workflow provides a practical and transferable approach for improving structural characterization, reducing uncertainty in permeability architecture, and supporting reservoir modeling and stimulation design in fractured crystalline EGS reservoirs.

58 GEOSCIENCES↗

Preliminary Analysis of Source Physics Experiment Explosion-Triggered Microseismicity Using the Back-Projection Method

A series of four chemical explosions were detonated in a deep borehole within the Yucca Flat Dry Alluvium Geology (DAG) at the Nevada National Security Site between 2018 and 2019. The two larger chemical explosions of 50 tons (DAG-2) and 10 tons (DAG-4) TNT equivalent yield triggered energetic aftershock sequences numbering 1392 and 347 microearthquakes, respectively, within the first 10 days. No significant aftershock activity was observed for the two smaller 1-ton explosions (DAG-1 and DAG-3). Here, we used a back-projection method based on travel-time migration and stacking of signal-to-noise ratio traces to detect, associate and locate aftershocks from a subset of 22-geophones within a larger 2 urn:x-wiley:21699313:media:jgrb54910:jgrb54910-math-0001 2 km seismic array surrounding the borehole. The aftershocks located within 300 m of the borehole and the depths were above the working points of 300 and 50 m depths of DAG-2 and DAG-4, respectively, ruling out triggering slip on geologic faults or disturbances beneath neighboring collapse craters. DAG-2 and DAG-4 aftershocks decayed at similar rates, with power-law exponents of p = 1.48 and p = 1.49, respectively. These decay rates are comparable to aftershocks sequences triggered by earthquakes and historical nuclear explosions at Yucca Flat. A smooth power-law aftershock decay within the first 10 days suggests a triggering mechanism from explosion generated stress relaxation due to the diffusion of high gas pressures in the cavity and radial fractures. A more random and episodic aftershock rate would be expected due to cavity collapse or falling rubble in chimney formation.

58 GEOSCIENCES↗

LandRAY Final Report

The overarching Project objective is to demonstrate the feasibility of using an innovative Power Take-Off (PTO) Module, to be used in the Columbia Power Technologies, Inc. (C·Power) utility-scale wave energy converter (WEC). The PTO Module uniquely combines a large-diameter, direct-drive, rotary permanent magnet generator; a patent-pending rail-bearing system; and a corrosion-resistant fiber-reinforced-plastic structure. The rail bearing system allows for: • A flexible non-rigid and low-cost generator frame as compared to conventional machines. • A reduction of air gap and consequently lower cost electromagnetic design • Ability to reduce costs by increasing diameter to much larger dimensions, while maintaining the small air gap. • A direct drive electro-mechanical solution that is the fastest and most precise approach for responding to the dynamic variability of forces from wave energy. The land-based test of the PTO Module (DDP1) will provide an important risk reduction phase, to demonstrate the reliability and feasibility of a large-diameter, small air-gap generator that is capable of delivering high efficiency, fault-tolerance and relatively simple "at-sea" maintenance capabilities – qualities that are essential for cost-effective wave energy devices. This is the first known test of such a system.

16 TIDAL AND WAVE POWER↗

Linking electronic structure calculations to generalized stacking fault energies in multicomponent alloys

Abstract The generalized stacking fault energy is a key ingredient to mesoscale models of dislocations. Here we develop an approach to quantify the dependence of generalized stacking fault energies on the degree of chemical disorder in multicomponent alloys. We introduce the notion of a “configurationally-resolved planar fault” (CRPF) energy and extend the cluster expansion method from alloy theory to express the CRPF as a function of chemical occupation variables of sites surrounding the fault. We apply the approach to explore the composition and temperature dependence of the unstable stacking fault energy (USF) in binary Mo–Nb alloys. First-principles calculations are used to parameterize a formation energy and CRPF cluster expansion. Monte Carlo simulations show that the distribution of USF energies is significantly affected by chemical composition and temperature. The formalism is broadly applicable to arbitrary crystal structures and alloy chemistries and will enable the development of rigorous models for deformation mechanisms in high-entropy alloys.

Natarajan, Anirudh Raju (ORCID:0000000202529480)↗

In-Situ Transmission Electron Microscopy Study of the Evolution of Extended Defects in Oxide Nuclear Fuels

In-situ transmission electron microscopy (TEM) with simulated extreme environments is an effective tool for understanding and tracking microstructural changes down to the atomic scale. The objective of this research is to study the effect of temperature on the evolution of extended defects in ThO2 and UO2. Here, we present in-situ TEM isochronal thermal annealing experiments using a micro-electro-mechanical-system (MEMS)-based heating holder. ThO2 and UO2 single crystal specimens were grown inside an inert silver ampoule using hydrothermal synthesis. Both samples were irradiated using 2 MeV protons at 600oC up to 0.1 dpa at Texas A&M University’s Accelerator Laboratory. Fig. 1a shows a weak-beam dark field TEM image of ThO2 after irradiation, indicating the presence of faulted 1/3 <111> type dislocation loops. This presentation will discuss the effect of annealing temperature (600oC, 800oC, 1000oC, 1100oC, etc.) on dislocation loop density, size and distribution, loop nature (interstitial/vacancies) and Burgers vector, as well as the formation of voids in both ThO2 and UO2. This work will also discuss the interaction between defects during annealing. The in-situ TEM annealing cycle is shown in Fig 1b. This research significantly improves the understanding of defect behavior in oxide nuclear fuels with temperature and will aid computational modeling efforts. This work was supported as part of the Center for Thermal Energy Transport under Irradiation (TETI) Energy Frontier Research Center, funded by the U.S. Department of Energy Office of Science.

36 MATERIALS SCIENCE↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

Deformation behavior of crystalline/amorphous Al-Si nanocomposites with nanolaminate or nanofibrous microstructures

Deformation mechanisms in sputter-deposited crystalline Al/amorphous Si nanocomposites with nanolaminate or nanofibrous morphology are characterized by nanoindentation, micropillar compression testing and transmission electron microscopy (TEM). The nanofibrous composite having crystalline Al nanofibers with ~40–50 nm in length and 15–20 nm in diameter embedded in amorphous Si exhibits strain hardening to a maximum flow stress of 2.9 GPa and no shear band (SB) formation in compression up to plastic strain exceeding 24%. On the other hand, nanolaminate composite that is composed of 80 nm crystalline Al layers and 20 nm amorphous Si layers exhibits catastrophic SBs starting at plastic strains in the range of 5–10%. Cross-sectional TEM of the deformed samples reveals a high density of stacking faults and twin boundaries in Al nanofibers and no microshear bands in the nanofibrous composite, suggesting plastic deformation in amorphous Si phase and crystalline Al nanofibers. Further, molecular dynamics simulations revealed that the plastic deformation in amorphous Si phase in the cosputtered films could be favored by the decrease in flow strength of amorphous Si with increasing Al solute concentration trapped in Si.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Test Bed for Evaluating Frequency Estimation Algorithms in Synthetic Inertia Control: User Manual

As penetration of converter interfaced generators (CIGs) increases, the need for CIG frequency control participation increases. Traditionally, research in this area has been performed using positive sequence simulation software, which provides voltage magnitude and phase measurements, but not point-on-wave (POW) measurements. This means that the effect of frequency estimation algorithms cannot be accurately modeled, especially when the voltage waveform is distorted by faults or load connection events. This report serves as a user manual for an electromagnetic transient simulation testbed, which allows for accurate modeling of frequency estimation and control techniques.

42 ENGINEERING↗

Distorted dislocation cores and asymmetric glide resistances in titanium

The determination of Critical Resolved Shear Stress (CRSS) in titanium for basal, prismatic, and pyramidal slip-planes without empirical constants is presented by combining Density Functional Theory (DFT) and anisotropic elasticity. A new mechanism leading to tension-compression (T-C) asymmetry in the CRSS levels has been revealed for the first time. The conditions for this asymmetry are established, involving a complex interplay between the dislocation core-structure and core-advance behavior. The three conditions for T-C asymmetry that need to be simultaneously satisfied can be summarized as: (1) a medium stacking fault width, d, (3 < d/b F < 10, where b F is the magnitude of the Burgers vector of the full dislocation), (2) an asymmetric core-structure of the extended dislocation (ξ 1 ≠ ξ 2 , where ξ 1 and ξ 2 are the core-widths of the first and second partials, respectively), and (3) intermittent motion of the partials (Δd/b F ≠ 0, where Δd is the magnitude of fluctuation in stacking fault width during intermittent motion). Pyramidal-slip in titanium satisfies all three conditions, resulting in significant T-C asymmetry. The CRSS theory considers a Wigner-Seitz (W-S) cell based domain area assigned to each lattice site for the calculations of core-energies accurately capturing the slip-plane lattice. The W-S based approach is essential due to the lower symmetry of the HCP crystal circumventing potential errors associated with the one-dimensional atomic-row approximation. Dislocation core structures are obtained for all the slip-systems in titanium showing significant distortion of the disregistry profile governing the core-advance behavior. The CRSS values predicted from the theory show agreement with the experimental CRSS levels reported in the literature.

Dislocation core↗

Property Variations in Modern REBCO Coated Conductors from Multiple Manufacturers

The complex, multilayer structure of REBCO Coated Conductor (CC) poses significant challenges in the fabrication of high magnetic field devices where large stresses may initiate various forms of damage. Our goal is to peer below the cartoon representations of CC so that, amongst other things, we might better understand whether a CC from one manufacturer is interchangeable with that from another. This involves knowledge of a broad range of electromagnetic, geometric, microstructural, and J c (θ,B,T) properties, and their variations that collectively pose challenges for the fault tolerance of REBCO CC devices. Accordingly, comparative measurements of J c , visualization of flux penetration with Magneto-Optical Imaging (MOI), tape geometry from Scanning Electron Microscopy (SEM) of polished cross-sections, and extensive optical microscopy was performed on recently purchased samples from multiple manufacturers. Our analyses reveal many deviations from or characteristics absent from manufacturers’ specifications, while a comparison of different manufacturers’ mechanically and laser slit tapes shows a diverse array of slitting characteristics amongst the manufacturers and variation in properties those made to the same specification. Laser slit tapes from several manufacturers reveal ablated edges with damaged regions extending up to 50 μm, comparable to the damaged region found in the mechanically slit CC of this study. Overall, the aim of this study is to flesh out appropriate ways to understand the real conductor below the manufacturers’ cartoons to avoid surprises in our REBCO CC coil development program. The goal of this work was to perform a broad array of characterizations of the type needed for validation of purpose for making high field magnets: to our surprise we found a wide range of properties which greatly impact the mechanical strength and electromagnetic performance of solenoids composed of these conductors and reinforced the need for a broad characterization program for each conductor prior to its implementation.

Bradford, G.↗

Phase stability in the Hf-N and Zr-N systems

Hf and Zr nitrides are promising compounds for many technologically important areas, including high-temperature structural applications, quantum computing, and solar and optical applications. Here, this article reports on a comprehensive first-principles statistical mechanics study of phase stability in the Hf-N and Zr-N binary systems. A high solubility of nitrogen in the hcp forms of Hf and Zr is predicted. The rocksalt forms of HfN and ZrN can also tolerate a high degree of off-stoichiometry through the introduction of nitrogen and metal vacancies. The Hf-N binary favors a family of stacking faulted parent crystal structures at intermediate nitrogen concentrations that host a unique form of short-range order among nitrogen interstitials and vacancies. These phases can accommodate some degree of configurational entropy and remain ordered to temperatures as high as 1200 K.

Monte Carlo methods↗

Whole-lithosphere shear during oblique rifting

Processes controlling the formation of continental whole-lithosphere shear zones are debated, but their existence requires that the lithosphere is mechanically coupled from base to top. We document the formation of a dextral, whole-lithosphere shear zone in the Death Valley region (DVR), southwest United States. Dextral deflections of depth gradients in the lithosphere-asthenosphere boundary and Moho are stacked vertically, defining a 20–50-km-wide, lower lithospheric shear zone with ~60 km of shear. These deflections underlie an upper-crustal fault zone that accrued ~60 km of dextral slip since ca. 8–7 Ma, when we infer that whole-lithosphere shear began. This dextral offset is less than net dextral offset on the upper-crustal fault zone (~90 km, ca. 13–0 Ma) and total upper-crustal extension (~250 km, ca. 16–0 Ma). We show that, before ca. 8–7 Ma, weak middle crust decoupled upper-crustal deformation from deformation in the lower crust and mantle lithosphere. Between 16 and 7 Ma, detachment slip thinned, uplifted, cooled, and thus strengthened the middle crust, which is exposed in metamorphic core complexes collocated with the whole-lithosphere shear zone. Midcrustal strengthening coupled the layered lithosphere vertically and therefore enabled whole-lithosphere dextral shear. Where thick crust exists (as in pre–16 Ma DVR), midcrustal strengthening is probably a necessary condition for whole-lithosphere shear.

58 GEOSCIENCES↗

Disconnection-Mediated Transition in Segregation Structures at Twin Boundaries

Twin boundaries play an important role in the thermodynamics, stability, and mechanical properties of nanocrystalline metals. Understanding their structure and chemistry at the atomic scale is key to guide strategies for fabricating nanocrystalline materials with improved properties. In this work, we report an unusual segregation phenomenon at gold-doped platinum twin boundaries, which is arbitrated by the presence of disconnections, a type of interfacial line defect. By using atomistic simulations, we show that disconnections containing a stacking fault can induce an unexpected transition in the interfacial-segregation structure at the atomic scale, from a bilayer, alternating-segregation structure to a trilayer, segregation-only structure. This behavior is found for faulted disconnections of varying step heights and dislocation characters. Supported by a structural analysis and the classical Langmuir–McLean segregation model, we reveal that this phenomenon is driven by a structurally induced drop of the local pressure across the faulted disconnection accompanied by an increase in the segregation volume.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiscale Assessment of Caprock Integrity for Geologic Carbon Storage in the Pennsylvanian Farnsworth Unit, Texas, USA

Leakage pathways through caprock lithologies for underground storage of CO2 and/or enhanced oil recovery (EOR) include intrusion into nano-pore mudstones, flow within fractures and faults, and larger-scale sedimentary heterogeneity (e.g., stacked channel deposits). To assess multiscale sealing integrity of the caprock system that overlies the Morrow B sandstone reservoir, Farnsworth Unit (FWU), Texas, USA, we combine pore-to-core observations, laboratory testing, well logging results, and noble gas analysis. A cluster analysis combining gamma ray, compressional slowness, and other logs was combined with caliper responses and triaxial rock mechanics testing to define eleven lithologic classes across the upper Morrow shale and Thirteen Finger limestone caprock units, with estimations of dynamic elastic moduli and fracture breakdown pressures (minimum horizontal stress gradients) for each class. Mercury porosimetry determinations of CO2 column heights in sealing formations yield values exceeding reservoir height. Noble gas profiles provide a “geologic time-integrated” assessment of fluid flow across the reservoir-caprock system, with Morrow B reservoir measurements consistent with decades-long EOR water-flooding, and upper Morrow shale and lower Thirteen Finger limestone values being consistent with long-term geohydrologic isolation. Together, these data suggest an excellent sealing capacity for the FWU and provide limits for injection pressure increases accompanying carbon storage activities.

58 GEOSCIENCES↗

Improving Subsurface Stress Characterization for Carbon Dioxide Storage Projects

Researchers at New Mexico Tech, Los Alamos National Laboratory (LANL), Sandia National Laboratory (SNL), and other collaborators are developing a methodology to improve characterization of stress in the subsurface by means of a model-based inversion of reservoir engineering data, time lapse seismic measurements, and microseismicity. Historically, various geophysical techniques have been used in efforts to understand the state of stress in the subsurface through direct and indirect imaging of stress sensitive features (faults and fractures) and observations of transient stress related observations (time variant elastic moduli and microseismicity). Standard direct and indirect techniques for seismic fault and fracture imaging suffer from detectability limits due to reliance on high data quality and multiplicity. Variations in effective elastic properties from inversion of high quality seismic (Vertical Seismic Profile (VSP)) data may be used to infer stress near the wellbore through integration with independent experimental characterization of the stress-velocity relationship. Given a sufficiently robust observation network, microseismic emissions may be inverted to characterize focal mechanisms which, together with supporting assumptions and constraints, inform estimates of in-situ stress. While each of these techniques contributes in part to the characterization of stress within limited spatial and temporal domains, no one method provides an unambiguous stress measurement or a predictive capability over a site scale spatial extent. Challenges associated with solution non-uniqueness, measurement ambiguity, and irregular sampling may be greatly minimized through combination of one or more of independent measurements within a common framework in which realistic geological, hydrodynamic, geomechanical, and seismological constituent process models may act as constraints.

02 PETROLEUM↗

The novel Mechanical Ventilator Milano for the COVID-19 pandemic

This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Furthermore, following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world

60 APPLIED LIFE SCIENCES↗

Understanding the deformation behavior of the γ rich transformative Fe 38.5 Mn 20 Co 20 Cr 15 Si 5 Cu 1.5 complex concentrated alloy using in situ synchrotron diffraction

In situ tensile testing coupled with synchrotron x-ray diffraction was used to study the deformation behavior of metastability-engineered Fe 38.5 Mn 20 Co 20 Cr 15 Si 5 Cu 1.5 complex concentrated alloy. Monitoring the evolution of phase fraction and strain hardening response allowed the determination of true critical stress for the onset of the transformation-induced plasticity (TRIP) to be ∼375 MPa, preceded by slip starting at ∼255 MPa. In situ EBSD was used to validate the critical stress for transformation at the microstructure level and observe slip traces to confirm prior slip activity before the transformation. Further, a modeling framework based on stacking fault energy (SFE) was developed to predict the critical stress for transformation. Modeling suggested the SFE of the alloy to fall nearly 15 mJ/m 2 , which agrees well with SFE values calculated using synchrotron peak shifting (12 mJ/m 2 ) and thermodynamic calculation (11 mJ/m 2 ). As a result of γ-fcc to ε-hcp phase transformation, new {0002} ε planes emerged parallel to unaligned {111} γ planes with the tensile loading following S-N orientation relationship. Such selective emergence of new diffraction rings corresponding to ε phase is understood based on the reorientation of γ crystals with reference to tensile axis. In conclusion, this approach can be extended to effectively design alloys based on critical stress required for activating different deformation mechanisms to further push the limits of the strength-ductility envelope.

Complex concentrated alloy↗