Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Ultrasonic scanning system for imaging flaw growth in composites

A system for measuring and visually representing damage in composite specimens while they are being loaded was demonstrated. It uses a hobbiest grade microcomputer system to control data taking and image processing. The system scans operator selected regions of the specimen while it is under load in a tensile test machine and measures internal damage by the attenuation of a 2.5 MHz ultrasonic beam passed through the specimen. The microcomputer dynamically controls the position of ultrasonic transducers mounted on a two axis motor driven carriage. As many as 65,536 samples can be taken and filed on a floppy disk system in less than four minutes.

Kiraly, L. J.↗

Deep trap, laser activated image converting system

Receiving an optical image on the surface of a photoconducting semiconductor is presented, storing the image in deep traps of the semiconductor, and later scanning the semiconductor with a laser beam to empty the deep traps, thereby producing a video signal. The semiconductor is illuminated with photons of energy greater than the band gap producing electron-hole pairs in the semiconductor which subsequently fill traps in energy from the band edges. When the laser beam of low energy photons excites the trapped electrons and holes out of the traps into the conduction and valence bands, a photoconductivity can be observed.

Maserjian, J.↗

Small Interactive Image Processing System (SMIPS) users manual

The Small Interactive Image Processing System (SMIP) is designed to facilitate the acquisition, digital processing and recording of image data as well as pattern recognition in an interactive mode. Objectives of the system are ease of communication with the computer by personnel who are not expert programmers, fast response to requests for information on pictures, complete error recovery as well as simplification of future programming efforts for extension of the system. The SMIP system is intended for operation under OS/MVT on an IBM 360/75 or 91 computer equipped with the IBM-2250 Model 1 display unit. This terminal is used as an interface between user and main computer. It has an alphanumeric keyboard, a programmed function keyboard and a light pen which are used for specification of input to the system. Output from the system is displayed on the screen as messages and pictures.

Moik, J. G.↗

Computer processing of echocardiographic images

Systems for direct computer acquisition of the echo signal and subsequent computerized echocardiogram image processing were constructed. Such systems were used to generate images unobtainable by other techniques and to automatically perform quantitative measurements of cardiac structures (5,6,7). The techniques used in analyzing echocardiograms are discussed, and the complexity of the problems involved is illustrated. A description of how these problems may be solved is included.

Sanders, W. J.↗

Quickbird Satellite in-orbit Modulation Transfer Function (MTF) Measurement Using Edge, Pulse and Impulse Methods for Summer 2003

The spatial characteristics of an imaging system cannot be expressed by a single number or simple statement. However, the Modulation Transfer Function (MTF) is one approach to measure the spatial quality of an imaging system. Basically, MTF is the normalized spatial frequency response of an imaging system. The frequency response of the system can be evaluated by applying an impulse input. The resulting impulse response is termed the Point Spread function (PSF). This function is a measure of the amount of blurring present in the imaging system and is itself a useful measure of spatial quality. An underlying assumption is that the imaging system is linear and shift-independent. The Fourier transform of the PSF is called the Optical Transfer Function (OTF) and the normalized magnitude of the OTF is the MTF. In addition to using an impulse input, a knife-edge in technique has also been used in this project. The sharp edge exercises an imaging system at all spatial frequencies. The profile of an edge response from an imaging system is called an Edge Spread Function (ESF). Differentiation of the ESF results in a one-dimensional version of the Point Spread Function (PSF). Finally, MTF can be calculated through use of Fourier transform of the PSF as stated previously. Every image includes noise in some degree which makes MTF of PSF estimation more difficult. To avoid the noise effects, many MTF estimation approaches use smooth numerical models. Historically, Gaussian models and Fermi functions were applied to reduce the random noise in the output profiles. The pulse-input method was used to measure the MTF of the Landsat Thematic Mapper (TM) using 8th order even functions over the San Mateo Bridge in San Francisco, California. Because the bridge width was smaller than the 30-meter ground sample distance (GSD) of the TM, the Nyquist frequency was located before the first zero-crossing point of the sinc function from the Fourier transformation of the bridge pulse. To avoid the zero-crossing points in the frequency domain from a pulse, the pulse width should be less than the width of two pixels (or 2 GSD's), but the short extent of the pulse results in a poor signal-to-noise ratio. Similarly, for a high-resolution satellite imaging system such as Quickbird, the input pulse width was critical because of the zero crossing points and noise present in the background area. It is important, therefore, that the width of the input pulse be appropriately sized. Finally, the MTF was calculated by taking ratio between Fourier transform of output and Fourier transform of input. Regardless of whether the edge, pulse and impulse target method is used, the orientation of the targets is critical in order to obtain uniformly spaced sub-pixel data points. When the orientation is incorrect, sample data points tend to be located in clusters that result in poor reconstruction of the edge or pulse profiles. Thus, a compromise orientation must be selected so that all spectral bands can be accommodated. This report continues by outlining the objectives in Section 2, procedures followed in Section 3, descriptions of the field campaigns in Section 4, results in Section 5, and a brief summary in Section 6.

Helder, Dennis↗

The Seasat-A Synthetic Aperture Imaging Radar System

The Seasat-A Synthetic Aperture Imaging Radar System is the first radar system of its kind designed for orbital use. The requirement of this system is to generate continuous radar imagery with a 100-km swath with 25 m resolution from an orbital altitude of 800 km. These requirements impose unique system design problems and a description of the implementation will be given. The end to end data system will be described including interactions of the spacecraft, antenna, sensor, telemetry link, and data processor. The synthetic aperture radar system generates a large quantity of data (110 megabits per second) requiring the use of a dedicated data link. The data link selected for use with the synthetic aperture radar is an analog link with stable local oscillator encoding. The problems associated in telemetering the radar information with sufficient fidelity to synthesize an image on the ground will be described as well as the selected solutions to the problems. The interactions between the antenna attitude control system, rotation of the earth and the data processor will be described as well as proposed solutions, both optical and digital, to generate final imagery with the required 25 m resolution.

Jordan, R. L.↗

Model-based frequency response characterization of a digital-image analysis system for epifluorescence microscopy

Consideration is given to a model-based method for estimating the spatial frequency response of a digital-imaging system (e.g., a CCD camera) that is modeled as a linear, shift-invariant image acquisition subsystem that is cascaded with a linear, shift-variant sampling subsystem. The method characterizes the 2D frequency response of the image acquisition subsystem to beyond the Nyquist frequency by accounting explicitly for insufficient sampling and the sample-scene phase. Results for simulated systems and a real CCD-based epifluorescence microscopy system are presented to demonstrate the accuracy of the method.

Hazra, Rajeeb↗

A Seasat-A Synthetic Aperture Imaging Radar System

The Seasat-A Synthetic Aperture Imaging Radar System is the first radar system of its kind designed for the study of ocean wave patterns from orbit. The basic requirement of this system is to generate continuous radar imagery with a 100-km swath with 25 m resolution from an orbital altitude of 800 km. These requirements impose unique system design problems and their solutions will be stated. The end to end data system will be described including interactions of the spacecraft, antenna, sensor, telemetry link, and data processor. The synthetic aperture radar system generates a large quantity of data (110 megabits per second) requiring the use of a dedicated data link. The data link selected for use with the synthetic aperture radar is an analog link with stable local oscillator encoding. The problems associated in telemetering the radar information with sufficient fidelity to synthesize an image on the ground will be described as well as the selected solutions to the problems.

Jordan, R. L.↗

Modulation Transfer Function of Infrared Focal Plane Arrays

Modulation transfer function (MTF) is the ability of an imaging system to faithfully image a given object. The MTF of an imaging system quantifies the ability of the system to resolve or transfer spatial frequencies. In this presentation we will discuss the detail MTF measurements of 1024x1024 pixels mid -wavelength and long- wavelength quantum well infrared photodetector, and 320x256 pixels long- wavelength InAs/GaSb superlattice infrared focal plane arrays (FPAs). Long wavelength Complementary Barrier Infrared Detector (CBIRD) based on InAs/GaSb superlattice material is hybridized to recently designed and fabricated 320x256 pixel format ROIC. The n-type CBIRD was characterized in terms of performance and thermal stability. The experimentally measured NE delta T of the 8.8 micron cutoff n-CBIRD FPA was 18.6 mK with 300 K background and f/2 cold stop at 78K FPA operating temperature. The horizontal and vertical MTFs of this pixel fully delineated CBIRD FPA at Nyquist frequency are 49% and 52%, respectively.

long-wave infrared↗

The Penn State astronomical image processing system

The needs of modern astronomy for image processing set demanding standards in simultaneously requiring fast computation speed, high-quality graphic display, large data storage, and interactive response. An innovative image processing system was designed, integrated, and used; it is based on a supermicro architecture which is tailored specifically for astronomy, which provides a highly cost-effective alternative to the traditional minicomputer installation. The paper describes the design rationale, equipment selection, and software developed to allow other astronomers with similar needs to benefit from the present experience.

Truax, Ryland J.↗

A study program on large aperture electronic scanning phased array antennas for the shuttle imaging microwave system

Fundamental phased array theory and performance parameters are discussed in terms of their application to microwave radiometry, and four scanning phased arrays representing current examples of state-of-the-art phased array technology are evaluated for potential use as components of the multispectral antenna system for the space shuttle imaging microwave system (SIMS). A discussion of problem areas, both in performance and fabrication is included, with extrapolations of performance characteristics for phased array antennas of increased sizes up to 20 m by 20 m. The possibility of interlacing two or more phased arrays to achieve a multifrequency aperture is considered, and, finally, a specific antenna system is recommended for use with SIMS.

Source record↗

Flight performance of a Shuttle-based image motion compensation system for the Ultraviolet Imaging Telescope

The design of the Ultraviolet Imaging Telescope (UIT) Image Motion Compensation System developed for the Columbia's Astro-1 mission is described, and the performance improvements derived through the use of this system are discussed. Flight data are presented, demonstrating the superb image stability achieved by UIT resulting in outstanding scientific data returns.

Deily, John J.↗

On-board fault-tolerant SAR processor for spaceborne imaging radar systems

A real-time high-performance and fault-tolerant FPGA-based hardware architecture for the processing of synthetic aperture radar (SAR) images has been developed for advanced spaceborne radar imaging systems. In this paper, we present the integrated design approach, from top-level algorithm specifications, system architectures, design methodology, functional verification, performance validation, down to hardware design and implementation.

imaging Radar↗

Expert system for imaging spectrometer analysis results

Information on an expert system for imaging spectrometer analysis results is outlined. Implementation requirements, the Simple Tool for Automated Reasoning (STAR) program that provides a software environment for the development and operation of rule-based expert systems, STAR data structures, and rule-based identification of surface materials are among the topics outlined.

Borchardt, Gary C.↗

Real-time radiographic inspection facility

A real time radiographic inspection facility has been developed for nondestructive evaluation applications. It consists of an X-ray source, an X-ray sensitive television imaging system, an electronic analog image processing system, and a digital image processing system. The digital image processing system is composed of a computer with the necessary software to drive the overall facility. Descriptions are given of the design strategy, the facility's components, and its current capabilities.

Roberts, E., Jr.↗

Hyperspectral Systems Increase Imaging Capabilities

In 1983, NASA started developing hyperspectral systems to image in the ultraviolet and infrared wavelengths. In 2001, the first on-orbit hyperspectral imager, Hyperion, was launched aboard the Earth Observing-1 spacecraft. Based on the hyperspectral imaging sensors used in Earth observation satellites, Stennis Space Center engineers and Institute for Technology Development researchers collaborated on a new design that was smaller and used an improved scanner. Featured in Spinoff 2007, the technology is now exclusively licensed by Themis Vision Systems LLC, of Richmond, Virginia, and is widely used in medical and life sciences, defense and security, forensics, and microscopy.

Source record↗

Multi-spectral image dissector camera system

The image dissector sensor for the Earth Resources Program is evaluated using contrast and reflectance data. The ground resolution obtainable for low contrast at the targeted signal to noise ratio of 1.8 was defined. It is concluded that the system is capable of achieving the detection of small, low contrast ground targets from satellites.

Source record↗