Sterilizable battery
Development program for separator and modified polyethylene separator material for silver-zinc battery, and program for development of sealed heat sterilizable batteries
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Development program for separator and modified polyethylene separator material for silver-zinc battery, and program for development of sealed heat sterilizable batteries
Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.
Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.
The topics covered are presented in viewgraph form and include a flight program history and in-house activities. Some of the in-house activities addressed include secondary battery/cell testing and Hubble Space Telescope Test data updates involving the NiCd type 40 test - battery 1 and 2, the NiCd type 41 test battery, the general electric battery, the NiCd six-battery system, the six four-cell packs, fourteen-cell pack, three four-cell packs, the NiH2 six-battery system, and the flight spare battery. A general test data update is also presented for the twelve-cell pack, the four four-cell packs, the reconditioning test, and planned Ni-MH testing.
Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.
As spaceflight moves toward commercial solutions for Crew Vehicles and Space Stations, opportunity exists to lower costs with novel designs. Probe and cone docking systems provide a lightweight, low cost, and high-performance docking solution. This work revisits the Apollo probe and cone design and modifies it for the requirements of today’s computer-controlled spacecraft. This new system is called the Advanced Apollo Orbital Assembly (APOA) system, and is intended to support satellite, cargo, and space station assembly missions. A simulation of the APOA was programmed, components were sized, and a design was created by scaling the probe to the size of an EELV Secondary Payload Adapter (ESPA) tunnel. Prototype test hardware was 3D printed using Fused Deposition Modeling (FDM) methods with Polylactic Acid (PLA) material. Testing of the APOA-ESPA was conducted at Marshall Space Flight Center’s (MSFC) Flat Floor, and a test-correlated simulation is used to evaluate a Monte-Carlo of Initial Contact Conditions (ICC’s) to establish baseline performance. The successful development, test, and correlation of the APOA-ESPA proves the design validity and increases Technology Readiness Level (TRL) from 2 to 4. This work opens the door to construction of an APOA-ESPA from flight like materials, and to develop a larger scale prototype APOA. When the full scale APOA is incorporated with the Common Berthing Mechanism (CBM), becomes the Hybrid Berthing System (HBS), which allows for berthing without a robotic arm.
An ExB probe is an electric propulsion plume diagnostic that has at its core a Wien filter. Ions entering the instrument experience perpendicular electric and magnetic fields and are filtered based on their velocity. While the ExB probe can be used to estimate the ion velocity distribution function, in the electric propulsion community, it is commonly used to measure species fractions. There are numerous probe designs, implementation and operation procedures, and data analysis approaches described and in use across the community. This paper provides recommendations and descriptions of best practices for design, implementation, and data analysis for the ExB probe, with a particular emphasis on Hall and ion thrusters. This work contributes to the broader community goal to standardize the use of diagnostics in electric propulsion testing.
The Europa mission and spacecraft design presented unique challenges for selection of valve seat materials that met the fluid compatibility requirements, and combined fluid compatibility and high radiation exposure level requirements. The Europa spacecraft pressurization system valves will be exposed to fully saturated propellant vapor for the duration of the mission. The effects of Nitrogen Tetroxide (NTO) and Monomethylhydrazine (MMH) propellant vapors on heritage valve seat materials, such as Vespel SP-1 and Polychlorotrifluoroethylene (PCTFE), were evaluated to determine if an alternate material is required. In liquid system applications, Teflon is the only available compatible valve seat material. Radiation exposure data for Teflon in an air or vacuum environment has been previously documented. Radiation exposure data for Teflon in an oxidizer environment such as NTO, was not available, and it was unknown whether the effects would be similar to those on air-exposed samples. Material testing was conducted by Marshall Space Flight Center (MSFC) and White Sands Test Facility (WSTF) to determine the effects of propellant vapor on heritage seat materials for pressurization valve applications, and the effects of combined radiation and NTO propellant exposure on Teflon. The results indicated that changes in heritage pressurization valve seat materials' properties rendered them unsuitable for the Europa application. The combined radiation and NTO exposure testing of Teflon produced results equivalent to combined radiation and air exposure results.
This report describes a series of tests performed at Sandia’s burn site to better understand the behavior of aerosol commodities and their hazards in the transportation environment. This comes on the tail of a prior study on the use cases and historical hazards associated with aerosol commodities in the shipping environment (Cambridge Systematics Incorporated, CSI, 2020). It is also mindful of the National Fire Protection Agency NFPA30B standard for safe warehousing of aerosol commodities. Warehousing is different from transit because warehousing typically involves active suppression and mitigation measures not practical or relevant to the shipping environment. Transit also typically involves tighter packing and smaller enclosure spaces. The transportation hazard space has not been heavily studied in prior testing specifically aimed towards the ground, rail, and nautical shipping environments.
This work focuses on the development and testing of a low-cost wireless communication system for heliostat fields, enabling significant capital costs reductions for concentrating solar thermal systems. Outputs of this work include a working demonstration of a multi-node communication system, clear reporting of system performance, and technical documentation of system development and architecture for reproducibility. Through this process, an open-source repository was created for manufacturing hardware at ~$30/heliostat. The system includes software for cybersecurity, achieving sub-second communication latencies and derisking of hardware for eventual scale-up to tens of thousands of heliostats. While the system is not currently off-the-shelf ready, there is now a clearly defined pathway for scaling up and completing the commercial development process.
Electrified aircraft are being developed to increase the efficiency and reduce the cost of operating subsonic transport aircraft. Achieving a substantial impact necessitates focusing on single- and twin-aisle aircraft which use propulsion systems with >20 MW ratings. For these aircraft, multi-MW superconducting electric machines are being developed due to their high specific power and high efficiency. Most of these electric machines employ superconductors on their rotor, thereby requiring cryogenic cooling of the rotating system. An attractive solution is to conductively cool the rotor using a cryocooler that rotates with the rotor. NASA has been developing a 50 K pulse tube cryocooler for its High Efficiency Megawatt Motor (HEMM) that can operate while rotating at 6,800 rpm. The design of this cryocooler and testing of its linear motor have been discussed in prior work. This presentation presents the first measurements of the complete HEMM cryocooler. The design and results of a stationary (non-rotating) test of the cryocooler are described.
PFE Auxiliary Systems conducted drop testing on SAVY-4000 containers to evaluate structural response under 12-foot drop conditions. In support of that effort, a finite-element modeling capability was developed to simulate drop response across multiple container sizes and impact orientations. The purpose of this work was to provide a consistent analysis framework that could support interpretation of testing, compare response trends across multiple configurations, and generate quantities of interest for later comparison with experimental data. More broadly, the analysis and testing were intended to assess whether the containers continued to perform their primary function after a 12-foot drop, namely maintaining structural integrity and containment of the contents. The modeling approach combined an implicit preload analysis with an explicit drop simulation so that each drop event began from a mechanically realistic assembled condition, including compression of the silicone O-ring. Separate models were developed for 2-quart, 5-quart, 12-quart, and 10-gallon containers. The results were evaluated in terms of strain-gauge response, collar-lid gap behavior, and accumulated plastic strain. In addition, parametric studies were performed on the 2-quart container to assess sensitivity to O-ring stiffness, friction, canister thickness, geometry tolerance, and mesh density. The simulations showed that predicted drop responses depended strongly on both container size and drop orientation. Gap metrics identified cases in which the predicted collar-lid opening exceeded the nominal O-ring cross-section threshold, while plastic strain metrics identified localized regions of elevated permanent deformation. Parametric studies showed that the predicted response was especially sensitive to the assumed O-ring stiffness and contact friction, while the geometry tolerance study produced smaller changes in the cases examined. The main value of this work was that it established a repeatable modeling and simulation workflow to support drop-test implementation, evaluate effects of future configuration changes, and understand modeling assumptions that most influenced predicted response. At the current stage, the results were viewed as preliminary model predictions rather than validated predictions. The next step would be to compare drop-test data to the model so that predictive values of the workflow could be refined and used with greater confidence to assess whether the containers maintained structural integrity and containment of the contents after a 12-foot drop.
Polymer separator materials for heat sterilizable battery
The Gear Test Assembly (GTA) is an experimental test apparatus built and installed in the Mechanisms and Engineering Test Loop (METL) at Argonne National Laboratory (ANL). While designed to accommodate a variety of components intended for use in advanced compact in-vessel transfer machine, the focus of GTA been the testing of large radial spur gears. The performance of the components used in GTA motivates the choices made in the design, components, and material choices for the forthcoming METL test articles; the Gripper Test Assembly (GrTA), and the Bearing Test Assembly (BTA). To date, GTA has completed nine experimental testing campaigns and achieved over 21 million revolutions under prototypic sodium fast reactor loads and operating conditions. This report provides an overview and results for the two most recent experiments Campaign #8 and Campaign #9. `Campaign #8 was the first campaign to make use of a set of nickel alloy radial spur gears, made from Hastelloy C-22HS, and combined with heat-treated tapered roller bearings. The bearings and torque profile used allowed Campaign #8 to be directly compared with Campaign #1 where Inconel 718 gears were used instead. Campaign #8 attained 1,058,880 shaft revolutions within 23% of the 1,314,855 revolutions achieved in Campaign #1. These results demonstrate that the heat-treated tapered roller bearings show consistent increased lifetimes, approximately three times longer than for non heat-treated taper rollers, and that the particular material of the gear does not play a substantial role in performance. Similar to Campaign #7 where bearing failure resulted in fragmentation and transport of bearing material into the gear teeth led to tooth damage in the Inconel gears, a similar process led to the damage of the Hastelloy gears. Subsequent NDE analysis showed that the damage was only limited to the tooth surface and does not extend into the gear interiors. Based on the NDE reports, the Hastelloy gears can be reconditioned and put back into service for future campaigns as was done for the Inconel gears. Reconditioned Inconel 718 gears damaged in Campaign #7 were returned to service in Campaign #9 and paired with non heat-treated tapered roller bearings. In Campaign #9 a novel set of operating conditions were implemented whereby the gears and bearings were cycled between hot, submerged refueling conditions where fuel handling operations occurred and cold, dry, and inert conditions where the sodium was drained and the vessel was allowed to cool simulating long, ex-vessel storage of the fuel handling machine. A total of eight of these operating cycles were achieved before a bearing failure occurred after the accumulation of 475,692 shaft revolutions were achieved. During Campaign #9, one of the drive motors was damaged and over the course of a 240 day standby period, the entire GTA drive system was upgraded from a 480VAC system to a 240VAC system that provided the opportunity to consolidate wall-space in the METL facility and provide more space for additional test articles being installed in the coming year. The over 475,000 shaft revolutions achieved in Campaign #9 eclipses the previous record for lifetime of non heat-treated tapered roller bearings held by Campaign #3 of 392,000 shaft revolutions. Further analysis and future campaigns hope to shed light on the cause of this approximately 17% increase in lifetime.
This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH 2 ). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH 2 temperatures (20.3 – 24.2 K), pressures (100 – 350 kPa), and flow rates (0.010 – 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.
Inorganic separator for high temperature silver-zinc battery
Filler and matrix composite materials for use in silver-zinc battery separators
In a continuing effort to develop NiH2 bipolar technology to a point where it can be used efficiently in space flight, testing of a second 40 Ahr, 10-cell bipolar battery has begun. This battery has undergone extensive characterization testing to determine the effects of such operating parameters as charge and discharge rates, temperature, and pressure. The fundamental design of this actively cooled bipolar battery is the same as the first battery. Most of the individual components, however, are from different manufacturers. Different testing procedures as well as certain unique battery characteristics make it difficult to directly compare the two sets of results. In general, the performance of this battery throughout characterization produced expected results. The main differences seen between the first and second batteries occurred during the high-rate discharge portion of the test matrix. The first battery also had poor high-rate discharge results, although better than those of the second battery. Minor changes were made to the battery frame design used for the first battery in an attempt to allow better gas access to the reaction sites for the second build and hopefully improve performance. The changes, however, did not improve the performance of the second battery and could have possibly contributed to the poorer performance that was observed. There are other component differences that could have contributed to the poorer performance of the second battery. The H2 electrode in the second battery was constructed with a Goretex backing which could have limited the high-rate current flow. The gas screen in the second battery had a larger mesh which again could have limited the high-rate current flow. Small scale 2 x 2 batteries are being tested to evaluate the effects of the component variations.