Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

An Evaluation of the Effect of Network Cost Optimization for Leadership Class Supercomputers

Dragonfly-based networks are an extensively deployed network topology in large-scale high-performance computing due to their cost-effectiveness and efficiency. The US will soon have three Exascale supercomputers for leadership class workloads deployed using dragonfly networks. Compared to indirect networks of similar scale, the dragonfly network has considerably reduced cable lengths, cable counts, and switch counts, resulting in significant network cost savings for a given system size, however, these cost reductions result in reduced global minimal paths and more challenging routing. Additionally, large scale dragonfly networks often require a taper at the global link level, resulting in less bisection bandwidth than is achievable in other traditional non-blocking topologies of equivalent scale. While dragonfly networks have been extensively studied, they have yet to be fully evaluated in an extreme scale (i.e., exascale) system that targets capability workloads. In this paper, we present the results of the first large scale evaluation of a dragonfly network on an exascale system (Frontier) and compare its behavior to a similar scale fat-tree network on a previous generation TOP500 system (Summit). This evaluation aims to determine the effect of network cost optimizations by measuring a tapered topology’s impact on capability workloads. Our evaluation is based on a collection of synthetic microbenchmarks, mini-apps, and full scale applications. It compares the scaling efficiencies of each benchmark between the dragonfly-based Frontier and the fat-tree-based Summit systems. Our results show that a dragonfly network is $\sim \mathbf{3 0 \%}$ more cost efficient than a fat-tree topology, which amortizes to $\sim 3 \%$ of an exascale system cost. Furthermore, while tapered dragonfly networks impose significant tradeoffs, the impacts are not as broad as initially thought and are mostly seen in applications with global communication patterns, particularly all-to-all (e.g., FFT-based algorithms), but also local communication patterns (e.g., nearest-neighbor algorithms) that are sensitive to network performance variability.

Khan, Awais↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Commissioning of the Power Supplies and Coils of the SMART Tokamak

The small aspect ratio tokamak (SMART) is a spherical tokamak (ST) that offers unique capabilities for studying the potential of negative triangularity. It has been designed, constructed, and is currently being operated by the Plasma Science Fusion Technology (PSFT) Laboratory at the University of Seville. SMART has a total of 21 coils, organized into seven independent circuits and driven by five modular power supplies (PS). The PS operation relies on switching converter technology based on IGBT and supercapacitors (SCs). The PS delivers predefined current waveforms to the copper coil system consisting of the central solenoid (CS), 12 toroidal field (TF) coils, three series pairs of poloidal field (PF) coils, and two independent PF coils. This study details the commissioning and validation of the PS toroidal and solenoid coils, as well as the assembly of coils in SMART. The maximum rated current and slope were measured, along with the series impedance of the coils, the output current ripple, and the noise levels. The internal parameters of the SCs were measured, and optimized current profiles were proposed to enhance overall performance. A comparison has been made between the theoretical values and the experimental results, providing insight into the performance of the PS and areas for improvement.

Power electronics↗

Resilience Analysis of DC Microgrids under Denial of Service Threats

This paper develops a resilience analysis framework to study the fault ride-through capability of direct current (DC) microgrids in unknown denial of service (DoS) cyber incidents. DoS can be a frequent threat to DC microgrids with advanced controllers that hinge on active information exchanges: it can paralyze data communications and cause control ineptness or even system instability. Furthermore, we show that temporal DoS incidents render the DC microgrid cyber-physical topology and parameters time-varying and cause them to jump between faulty conditions. As existing DC microgrid stability analysis results are primarily developed from time-invariant systems, they might not be valid for the DoS interrupted systems. In this paper, we seek to study whether a DC microgrid is resilient against time-varying unknown DoS incidents. The problem is formulated as a stability analysis problem for a system with randomly switching dynamics. Scalable conditions are developed to provide provable resilience guarantees. In addition, we exploit the special structure of the conditions to yield quantified resilience measure by convex optimization techniques. As a result, the measure can be used for the evaluation of the resilience of different DC microgrid design against DoS incidents. We demonstrate the effectiveness of the proposed work using simulation case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the wall perturbation correction for a parallel-plate NACP-02 chamber in clinical electron beams

Purpose: In recent years, several Monte Carlo studies have been published concerning the perturbation corrections of a parallel-plate chamber in clinical electron beams. In these studies, a strong depth dependence of the relevant correction factors (p{sub wall} and p{sub cav}) for depth beyond the reference depth is recognized and it has been shown that the variation with depth is sensitive to the choice of the chamber's effective point of measurement. Recommendations concerning the positioning of parallel-plate ionization chambers in clinical electron beams are not the same for all current dosimetry protocols. The IAEA TRS-398 as well as the IPEM protocol and the German protocol DIN 6800-2 interpret the depth of measurement within the phantom as the water equivalent depth, i.e., the nonwater equivalence of the entrance window has to be accounted for by shifting the chamber by an amount {Delta}z. This positioning should ensure that the primary electrons traveling from the surface of the water phantom through the entrance window to the chamber's reference point sustain the same energy loss as the primary electrons in the undisturbed phantom. The objective of the present study is the determination of the shift {Delta}z for a NACP-02 chamber and the calculation of the resulting wall perturbation correction as a function of depth. Moreover, the contributions of the different chamber walls to the wall perturbation correction are identified. Methods: The dose and fluence within the NACP-02 chamber and a wall-less air cavity is calculated using the Monte Carlo code EGSnrc in a water phantom at different depths for different clinical electron beams. In order to determine the necessary shift to account for the nonwater equivalence of the entrance window, the chamber is shifted in steps {Delta}z around the depth of measurement. The optimal shift {Delta}z is determined from a comparison of the spectral fluence within the chamber and the bare cavity. The wall perturbation correction is calculated as the ratio between doses for the complete chamber and a wall-less air cavity. Results: The high energy part of the fluence spectra within the chamber strongly varies even with small chamber shifts, allowing the determination of {Delta}z within micrometers. For the NACP-02 chamber a shift {Delta}z=-0.058 cm results. This value is independent of the energy of the primary electrons as well as of the depth within the phantom and it is in good agreement with the value recommended in the German dosimetry protocol. Applying this shift, the calculated wall perturbation correction as a function of depth is varying less than 1% from zero up to the half value depth R{sub 50} for electron energies in the range of 6-21 MeV. The remaining depth dependence can mainly be attributed to the scatter properties of the entrance window. When neglecting the nonwater equivalence of the entrance window, the variation of p{sub wall} with depth is up to 10% and more, especially for low electron energies. Conclusions: The variation of the wall perturbation correction for the NACP-02 chamber in clinical electron beams strongly depends on the positioning of the chamber. Applying a shift {Delta}z=-0.058 cm toward the focus ensures that the primary electron spectrum within the chamber bears the largest resemblance to the fluence of a wall-less cavity. Hence, the influence of the chamber walls on the perturbation correction can be separated out and the residual variation of p{sub wall} with depth is minimized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-176: Examination of Surface Dose Enhancement Using Radiochromic EBT3-Films in a Cylindrical Setup

Purpose: This study was undertaken to optimize the measurement techniques with radiochromic EBT3 films to offer accurate surface dose measurements and at the same time high resolution depth dose curves of the backscattering from high Z materials. Methods: Radiochromic EBT3 films (Ashland ISP, Wayne, USA) were wrapped around a PET hollow cylinder with a diameter of 41.5 mm and fixed upon the surface of a lead block. The setup was immersed in water and exposed to a dose of 2 Gy at 6MV acceleration voltage using a Siemens Primus linear accelerator. Water reference measurements were undertaken under equal conditions. An Epson Expression 10000 XL flatbed scanner (Epson, Suwa, Japan) with a preset resolution of 72 dpi was used for digitization. Results: The dose enhancement could be measured with a high resolution of measurement points along the axis normal to the lead surface. A dose enhancement of 70 % was measured at a distance of 134 μm from the lead surface. The data has been compared with results presented by Das et al (Med. Phys. 16(3) (1989)) and is consistent within the uncertainty of the measurements. The results are in consistence with the results from time-tested EBT3 setups, i.e. normal-to-beam EBT3 film stacks and parallel to beam EBT3-films. Conclusion: The cylindrical film setup offers a powerful tool for surface measurements. The advantages of a stacked film setup and a parallel to beam setup could be combined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Resolved Molecular Frame Dynamics of Fixed-in-Space CS2 Molecules

Random orientation of molecules within a sample leads to blurred observationsof chemical reactions studied from the laboratory perspective. Methodsdeveloped for the dynamic imaging of molecular structures and processesstruggle with this, as measurements are optimally made in the molecular frame.Here we uselaser alignment to transiently fix CS2 molecules in space longenough to elucidate, in the molecular reference frame, details of ultrafast electronic vibrationaldynamics during a photochemical reaction. These three-dimensional photoelectron imaging results, combined with ongoing efforts in molecular alignment and orientation, presage a wide range of insights obtainable fromtime-resolved studies in the molecular frame.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fast Ignition Target Compression Campaign

We propose an experimental campaign on the NIF to validate key elements of the fast ignition target design. Experimental measurements will provide feedback for refinement of the target design. In lieu of the cryogenic DT target, which requires ongoing target fabrication R&D, the initial experiments will use a surrogate target design consisting of a cryogenic H/He gas-filled hohlraum with CH capsule. In the first year we will validate hohlraum energetics, symmetry tuning, and measure peak ρR with spherical capsule implosions, for each of our two candidate pulse shapes, with the aim of down selecting to a preferred drive pulse. In the second year we will progress to cone-in-shell implosions, using x-ray radiography and Streaked Optical Pyrometry (SOP) inside the cone to measure and optimize the ρR and shape of the compressed core and the timing between optimum fuel compression and shock breakout in the cone. Our goal is to establish an indirect drive fast ignition compression platform that will demonstrate the validity of the implosion scheme, and provide a basis for future core heating experiments using the 10 kJ, 10 ps Advanced Radiographic Capability (ARC) short-pulse NIF beam line.

42 ENGINEERING↗

Measure Guideline: Condensing Boilers-Optimizing Efficiency and Response Time During Setback Operation

Conventional wisdom surrounding space heating has consistently stated two things: size the mechanical systems to the heating loads, and setting the thermostat back at night will result in energy savings. The problem is these two recommendations oppose each other. A system that is properly sized to the heating load will not have the extra capacity necessary to recover from a thermostat setback, especially at design conditions. The implication of this is that, for setback to be successfully implemented, the heating system must be oversized. This issue is exacerbated further when an outdoor reset control is used with a condensing boiler, because not only is the system matched to the load at design, the outdoor reset control matches the output to the load under varying outdoor temperatures. Under these circumstances, the home may never recover from setback. Special controls to bypass the outdoor reset sensor are then needed. Properly designing a hydronic system for setback operation can be accomplished but depends on several factors. The first step is to determine the appropriateness of setback for a particular project. This is followed by proper sizing of the boiler and baseboard to ensure the needed capacity can be met. Finally, control settings must be chosen that result in the most efficient and responsive performance. This guide provides step-by-step instructions for heating contractors and hydronic designers for selecting the proper control settings to maximize system performance and improve response time when using a thermostat setback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Code for Photocathode Design

The Phase I activity demonstrated that PhotoQE could be upgraded and modified to allow input using a graphical user interface. Specific calls to platform-dependent (e.g. IMSL) function calls were removed, and Fortran77 components were rewritten for Fortran95 compliance. The subroutines, specifically the common block structures and shared data parameters, were reworked to allow the GUI to update material parameter data, and the system was targeted for desktop personal computer operation. The new structures overcomes the previous rigid and unmodifiable library structures by implementing new, materials library data sets and repositioning the library values to external files. Material data may originate from published literature or experimental measurements. Further optimization and restructuring would allow custom and specific emission models for beam codes that rely on parameterized photoemission algorithms. These would be based on simplified and parametric representations updated and extended from previous versions (e.g., Modified Fowler-Dubridge, Modified Three-Step, etc.).

43 PARTICLE ACCELERATORS↗

Urban Flooding Analysis Using Radar Rainfall Data and 2-D Hydrodynamic Model: A Pilot Study of Back Cover Area, Portland, Maine

This project is a part of the Regional Resiliency Assessment Program, led by the Department of Homeland Security, to address flooding hazards of regional significance for Portland, Maine. The pilot study was performed by Argonne National Laboratory to identify differences in spatial rainfall distributions between the radar-derived and rain-gauge rainfall datasets and to evaluate their impacts on urban flooding. The flooding impact analysis utilized a high-resolution 2-dimensional (2-D) hydrodynamic model (15 ft by 15 ft) incorporating the buildings, streets, stream channels, hydraulic structures, an existing city storm drain system, and assuming a storm surge along the coast coincident with a heavy rainfall event. Two historical storm events from April 16, 2007, and September 29, 2015, were selected for evaluation. The radar-derived rainfall data at a 200-m resolution provide spatially-varied rainfall patterns with a wide range of intensities for each event. The resultant maximum flood depth using data from a single rain gauge within the study area could be off (either under- or over-estimated) by more than 10% in the 2007 storm and more than 60% in the 2015 storm compared to the radar-derived rainfall data. The model results also suggest that the inundation area with a flow depth at or greater than 0.5 ft could reach 11% (2007 storm) and 17% (2015 storm) of the total study area, respectively. The lowland areas within the neighborhoods of North Deering, East Deering, East and West Baysides and northeastern Parkside, appear to be more vulnerable to the flood hazard in both storm events. The high-resolution 2-D hydrodynamic model with high-resolution radar-derived rainfall data provides an excellent tool for detailed urban flood analysis and vulnerability assessment. The model developed in this study could be potentially used to evaluate any proposed mitigation measures and optimize their effects in the future for Portland, ME.

54 ENVIRONMENTAL SCIENCES↗

Integrating Health and Energy Efficiency in Healthcare Facilities

In this report, PNNL presents a review of literature and current best practices along the intersection of energy efficiency and occupant health at U.S. healthcare facilities, including federally owned buildings. This report includes a review of building standards and certification systems for healthcare indoor environmental quality (IEQ) and research on building measures that optimize occupant health and energy efficiency. The healthcare industry includes a wide variety of services and thus facility types. This case study focuses primarily on inpatient facilities, such as hospitals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating Health and Energy Efficiency in Healthcare Facilities

This report presents a review of literature and current best practices along the intersection of energy efficiency and occupant health at U.S. healthcare facilities, including federally owned buildings. It also includes a review of minimum code requirements for healthcare indoor environmental quality (IEQ) and research on building measures that optimize occupant health and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility Study of Spectrophotometry to Support a Promethium Production Program at ORNL

Optical spectroscopy can be used to optimize analytical measurements for lanthanide elements and provide real-time feedback to help guide production operations. This study evaluates spectrophotometry for the determination of samarium (Sm 3+ ) and neodymium (Nd 3+ ) in aqueous and organic solutions at concentrations relevant to a promethium (Pm) program separation scheme. Detection limits approached 0.5 mM for Nd 3+ and 2 mM for Sm 3+ using Ocean Insight spectrophotometers. Additionally, Sm 3+ detection limits using laser fluorescence spectra for Sm 3+ approached single ppm (mg∙L -1 ) levels. An absorption spectrum containing Nd and Pm is also reported and discussed. This work demonstrates proofof-principle concepts for applying spectrophotometry to online monitoring applications in support of a future Pm production program.

47 OTHER INSTRUMENTATION↗

Level-1 Trigger and DAQ system of the GlueX experiment

The goal of the GlueX detector at Jefferson Lab is to study fundamental questions of the quantum chromodynamics, i.e., the nature of confinement of gluons and quarks. The detector's design is optimized to measure the spectrum of exotic mesons that are expected to be produced in interactions of 8.4 - 9.0 GeV linearly polarized photons with a liquid hydrogen target. The GlueX trigger and DAQ electronics is based on pipelined TDC boards and FADC boards running at a 250 MHz clock. The trigger logic is implemented on special purpose programmable electronics boards with Field-Programmable Gate Array chips. Two types of boards are used: Crate Trigger Processors and Global Trigger Processors. All trigger electronics is hosted in VXS crates. The Level-1 trigger should reduce the 200 MHz electromagnetic rate and the 400 kHz hadronic rate to 200 kHz total rate. The trigger algorithm makes use of a measurement of the energy deposition in two electromagnetic calorimeters and hit counts in the start counter, the time-of-flight detector, and the tagger hodoscopes. We will present the trigger and DAQ design of the GlueX experiment and describe the Level-1 trigger algorithm in detail..

Somov, Alexander↗

The DREAM approach to demand-side emissions reductions in Indonesia, 2020–2060

Indonesia’s current energy system modeling is heavily focused on the supply side, but emissions reductions in the demand sector have a significant impact on advancing Indonesia’s ambitious emissions reductions goals. To address the gap, we develop a new modeling tool DREAM Indonesia based on a bottom-up, technology-rich demand side framework and formulate projections of demand-side emissions reductions in Indonesia in 2020–2060. We find that demand-side energy efficiency and electrification can halve the growth rate of final energy demand to 1.4% annually over 2020–2060 and reverse the growing trend of emissions. The feasibility of full electrification by 2060, coupled with rapid adoption of existing technologies, positions the building sector as a model for achievable decarbonization and a cornerstone of Indonesia’s emissions reductions ambitions. In the industrial sector, extensive emissions reductions of 87% by 2060 (compared to business-as-usual) are achievable through energy efficiency improvements, alongside enhanced material efficiency measures including optimized material usage, low-carbon substitutions, innovative technologies, and increased circularity. In the transportation sector, balancing final energy demand by incorporating energy efficiency improvements across all transport modes, along with electrification particularly in road transportation, could decrease the emissions by up to 82% in 2060 compared to business-as-usual. This study provides insights and modeling approaches for rapidly growing Asian economies as well as other developing countries facing combined development and decarbonization challenges.

DREAM Indonesia↗

THE SPECTRUM AND TERM ANALYSIS OF CO iii MEASURED USING FOURIER TRANSFORM AND GRATING SPECTROSCOPY

The spectrum of Co iii has been recorded in the region 1562–2564 Å (64,000 cm{sup −1}–39,000 cm{sup −1}) by Fourier transform (FT) spectroscopy, and in the region 1317–2500 Å (164,000 cm{sup −1}–40,000 cm{sup −1}) using a 10.7 m grating spectrograph with phosphor image plate detectors. The spectrum was excited in a cobalt–neon Penning discharge lamp. We classified 514 Co iii lines measured using FT spectroscopy, the strongest having wavenumber uncertainties approaching 0.004 cm{sup −1} (approximately 0.2 mÅ at 2000 Å, or 1 part in 10{sup 7}), and 240 lines measured with grating spectroscopy with uncertainties between 5 and 10 mÅ. The wavelength calibration of 790 lines of Raassen and Ortí Ortin and 87 lines from Shenstone has been revised and combined with our measurements to optimize the values of all but one of the 288 previously reported energy levels. Order of magnitude reductions in uncertainty for almost two-thirds of the 3d{sup 6}4s and almost half of the 3d{sup 6}4p revised energy levels are obtained. Ritz wavelengths have been calculated for an additional 100 forbidden lines. Eigenvector percentage compositions for the energy levels and predicted oscillator strengths have been calculated using the Cowan code.

74 ATOMIC AND MOLECULAR PHYSICS↗