Search NASASearch

SEARCH · Search NASA

Results for “Modulus Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

577 records · Page 19

Design, Build and Qualification of 28 Volt Lithium-Ion battery

Contents include the following: 1. GSFC performance specifications requirements. 2. AEA philosophy: battery configuration. 3. AEA battery design: SONY cell, cell screening, 20Ah and 60Ah. 4. Testing: 20Ah battery qualification (environmental); 60Ah battery LEO life cycle. 5. Conclusion.: summary and lessons learned.

Curzon, D.

Swamp Works Regolith Compaction Technologies

While the level of compaction below the lunar surface increases quickly after only a few cm of depth, in many cases during a construction mission there will be a need to excavate and transport regolith to a new location for cut-and-fill or horizontal construction of structures such as berms. In these cases to achieve high levels of bulk density, compaction must be per-formed. Additionally, in some cases surface technolo-gies such as systems that sinter/melt the surface may desire the maximum possible compaction at the sur-face to improve melting/heating performance and the final material strength properties. Kennedy Space Center’s (KSC) Swamp Works has developed two means of compaction, lunar and mar-tian compaction. Planetary Autonomous Compaction Technology (PACT) which is part of the Multifunction End Effector for Regolith Compaction Acquisition and Transfer (MEERCAT [1]) robotic arm end effector system’s capabilities and the Site Preparation Tooling for Operations on Mobility Platforms (STOMP [2]) vibratory roller compactor. PACT on MEERCAT has been demonstrated to a TRL 5 and STOMP to a TRL 4 in ambient testing. The results of PACT on MEERCAT and STOMP testing will be shared with results for various simulants including BP-1, ICN-LHT-1G (aka CSM-LHT-1G), RDW-LHT-1GH (a simulant developed for the Mason Tipping Point to match characteristics of ICN-LHT-1G), and Exolith LHS-1E. This will also include discus-sions on methods used to verify relative density before and after compaction and means to verify density effects below depth. To calculate relative density, maximum and minimum densities for simulants were taken from literature [3] [4] [5] and additional lab test-ing (publication in work).

vibration

The 1975 GSFC Battery Workshop

The proceedings of the 1975 Goddard Space Flight Center Battery Workshop are presented. The major topics of discussion were nickel cadmium batteries and, to a lesser extent, nickel hydrogen batteries. Battery design, manufacturing techniques, testing programs, and electrochemical characteristics were considered. The utilization of these batteries for spacecraft power supplies was given particular attention.

Source record

Hubble Space Telescope 2004 Battery Update

Battery cell wear out mechanisms and signatures are examined and compared to orbital data from the six on-orbit Hubble Space Telescope (HST) batteries, and the Flight Spare Battery (FSB) Test Bed at Marshall Space Fiight Center (MSFC), which is instrumented with individual cell voltage monitoring.

Hollandsworth, Roger

Development of a silver-zinc battery system

Summary report is described of historical documentation and detailed design data for development of silver-zinc battery for use on Surveyor spacecraft. Electrical and physical characteristics of battery models are included, along with data on qualification, acceptance, solar-thermal-vacuum, mission simulation testing, and actual flight performance.

Moses, A. J.

Evaluation of Low-Energy Hydrogen Separation Method Using Metal-Organic Frameworks (MOFs) for Closed-Loop ECLSS Air Revitalization (CLEAR)

The State-of-the-Art (SOA) air revitalization architecture onboard the International Space Station (ISS) recovered approximately 50% of the oxygen (O 2 ) from metabolic carbon dioxide (CO 2 ) via the Sabatier process from 2011 to 2017. O 2 recovery is currently constrained by the limited availability of reactant hydrogen (H 2 ) preventing complete conversion of CO 2 to H 2 O. Increasing O 2 recovery within Closed-Loop ECLSS is essential to reducing resupply mass for long-duration manned missions; specifically focusing on water (H 2 O) which supplies H 2 for Sabatier via water electrolysis. Past ground test endeavors at Marshall Space Flight Center (MSFC) have attempted to recover H 2 from Sabatier-produced CH 4 using technologies such as carbon vapor deposition (CVD) and plasma pyrolysis. The byproducts of these technologies can act as a catalyst poison or reactor deadload to the Sabatier reactor. Hydrogen separation techniques must be utilized to maintain the Sabatier catalyst during gas recycling and must be scalable, non-energy intensive, and safe to operate in a habitation setting. Research indicated that metal-organic frameworks (MOFs) could meet these criteria and were tested for their capability to capture the various carbon-based gaseous products of CVD and plasma pyrolysis such as acetylene (C 2 H 2 ), ethylene (C 2 H 4 ), ethane (C 2 H 6 ), and carbon monoxide (CO) which would purify the hydrogen gas stream passing through the MOF. A sub-scale adsorption column was developed by Marshall Space Flight Center to test three MOF candidates against a synthetic gas mixture comprised of process-relevant carbonous gases and hydrogen to evaluate the separation capability of the MOFs. The results of the hydrogen separation capability, isothermal desorption capability, and demonstrated cyclic reuse of the MOF are presented in this paper.

Kagen Crawford

Autonomous Power Expert System Advanced Development

The autonomous power expert (APEX) system is being developed at Lewis Research Center to function as a fault diagnosis advisor for a space power distribution test bed. APEX is a rule-based system capable of detecting faults and isolating the probable causes. APEX also has a justification facility to provide natural language explanations about conclusions reached during fault isolation. To help maintain the health of the power distribution system, additional capabilities were added to APEX. These capabilities allow detection and isolation of incipient faults and enable the expert system to recommend actions/procedure to correct the suspected fault conditions. New capabilities for incipient fault detection consist of storage and analysis of historical data and new user interface displays. After the cause of a fault is determined, appropriate recommended actions are selected by rule-based inferencing which provides corrective/extended test procedures. Color graphics displays and improved mouse-selectable menus were also added to provide a friendlier user interface. A discussion of APEX in general and a more detailed description of the incipient detection, recommended actions, and user interface developments during the last year are presented.

Todd M Quinn

Thermal Imaging of Aerospace Battery Cells

The objective of the research covered by this viewgraph presentation is to understand the thermal characteristics of a cylindrical aerospace battery cell by studying the surface thermal properties. The batteries tested include a nickel hydrogen cell (NiH2), and a lithium-ion cell (Li-ion).

Shue, Jack

Powering the Lunar Surface: Managing Dust, Extreme Environments, and Power Needs

Power availability remains one of the primary constraints for lunar surface science. This talk reviews power requirements from previously flown instruments to help prepare future payloads for upcoming CLPS opportunities and highlights the testing and environmental simulation capabilities at NASA JSC that enable reliable lunar payload development. It also outlines the power needs, environmental challenges, and emerging technologies required to support sustained human and robotic operations on the lunar surface as part of NASA’s Moon to Mars strategy. Key challenges include variable solar illumination at polar and equatorial regions, extreme thermal environments, and dust driven degradation that limit current surface power systems. The science data needed for resource identification and landing site planning will allow for the successful preparation of crewed Artemis activities and long-term presence. Building on recent missions, current test infrastructure, and emerging power technology pathways, this presentation equips industry, academia, and government teams with the information needed to design robust lunar payloads, reduce development risk, and fully leverage the increasing cadence of CLPS missions. These developments will form a critical technical foundation for long duration lunar presence and future Mars exploration.

Anastasia Ford

Performance Optimization for Lunar Extravehicular Activity Readiness (POLAR) Study: Methods Paper

To better understand which aspects of physical fitness may be most related to performance during Lunar surface operations and thereby help to inform the current NASA fitness standards, much can be learned from fields encompassing the “tactical athlete.” Other physically demanding professions such as law enforcement, military, or rescue professionals often require candidates to meet occupationally-relevant fitness standards. The determination of such standards is a multistep process, including both objective and subjective measures, to determine tasks essential to occupational performance and identify the minimal fitness profile needed to meet physical demands of the job. Notably, fitness is only one component which may contribute to the demands of astronaut selection, flight assignment, and occupational performance. Utilizing a framework to systematically determine which domains of fitness most contribute to relevant job tasks can aid in the refinement of current NASA-STD-3001 fitness standards. Therefore, NASA’s Exercise Physiology & Countermeasures Laboratory conducted the Performance Optimization for Lunar Extravehicular Activity Readiness (POLAR) study to identify and examine a comprehensive list of fitness tests (including NASA-STD-3001 assessments: 1-Repetition Maximum [1-RM] bench press and deadlift) and determine preliminary relationships between identified fitness parameters and novel Artemis-relevant tasks to help inform future investigations for the continued development of aerobic and muscular fitness standards for surface EVAs. This was accomplished through 1) a review of the literature relating fitness assessments to simulated or real EVA performance to identify fitness tests that are most correlated with simulated EVA task performance; 2) a task analysis following a modified framework for physical employment standards development to down select mission critical tasks; and 3) development and pilot testing of a novel, portable Artemis-relevant EVA task circuit to relate to a battery of fitness assessments. The current report describes the methodology used to complete the task analysis, EVA task circuit development, and the pilot study.

Nicole C Strock

DS-2 Mars Microprobe Battery

In January of 1999 the NM DS-2 Mars microprobe will be launched to impact on Mars in December. The technical objectives of the missions are to demonstrate: key technologies, a passive atmospheric entry, highly integrated microelectronics which can withstand both low temperatures and high decelerations, and the capability to conduct in-situ, surface and subsurface science data acquisition. The scientific objectives are to determine if ice is present below the Martian surface, measure the local atmospheric pressure, characterize the thermal properties of the martian subsurface soil, and to estimate the vertical temperature gradient of the Martian soil. The battery requirements are 2-4 cell batteries, with voltage of 6-14 volts, capacity of 550 mAh at 80C, and 2Ah at 25C, shelf life of 2.5 years, an operating temperature of 60C and below, and the ability to withstand shock impact of 80,000 g's. The technical challenges and the approach is reviewed. The Li-SOCL2 system is reviewed, and graphs showing the current and voltage is displayed, along with the voltage over discharge time. The problems encountered during the testing were: (1) impact sensitivity, (2) cracking of the seals, and (3) delay in voltage. A new design resulted in no problems in the impact testing phase. The corrective actions for the seal problems involved: (1) pre weld fill tube, (2) an improved heat sink during case to cover weld and (3) change the seal dimensions to reduce stress. To correct the voltage delay problem the solutions involved: (1) drying the electrodes to reduce contamination by water, (2) assemblage of the cells within a week of electrode manufacture, (3) ensure electrolyte purity, and (4) provide second depassivation pulse after landing. The conclusions on further testing were that the battery can: (1) withstand anticipated shock of up to 80,000 g, (2) meet the discharge profile post shock at Mars temperatures, (3) meet the required self discharge rate and (4) meet environmental requirements.

Frank, H.

Outgassing Characterization of Common Trash Items for Disposal By Nanoracks Airlock on the International Space Station

The arrival of the Nanoracks Airlock to the International Space Station (ISS) has provided the ISS program the capability to dispose of common trash items. The concept of operations involved the crew bagging up those items into a trash bag and then utilizing the robotic arm and the airlock to jettison the trash bag. Because of the unknown thermal vacuum stability of some of the items, a molecular contamination concern was raised by the ISS program as the trash is exposed to vacuum upon the evacuation of air from the airlock and the robotic arm moving the airlock to its jettison location. In order to characterize the representative outgassing rates for ISS trash, thermal vacuum testing was performed at White Sands Test Facility. Trash was sorted into a “lower” outgassing bag and a “mixed” bag. The “mixed” trash bag contained more items that were suspected to be not vacuum stable. Load cells were chosen as the primary means for measuring mass loss. A sharp decay in the outgassing rate was observed in the first 30 minutes followed by a slower decay. As expected, the “mixed” bag lost more mass. While Quartz Crystal Microbalances (QCMs) are often utilized to measure long term outgassing rates and the sticking coefficients of contaminants at different operating temperatures for vacuum stable materials, these measurements proved difficult due to the amount and the inclusion of materials with suspect thermal vacuum stability. Because of high rates of material outgassing, the facility was unable to maintain the CQCM temperature setpoint of 80 K QCMs.. The QCMs operating at the warmer temperatures also saturated on occasion due to high levels of condensed matter. Though testing was able to confirm high risk of outgassing contamination for the program, true sticking coefficients could not be determined, available measurements are provided herein.

Alvin Y Huang

Powering the Lunar Surface: Managing Dust, Extreme Environments, and Power Needs

Power availability remains one of the primary constraints for lunar surface science. This talk reviews power requirements from previously flown instruments to help prepare future payloads for upcoming CLPS opportunities and highlights the testing and environmental simulation capabilities at NASA JSC that enable reliable lunar payload development. It also outlines the power needs, environmental challenges, and emerging technologies required to support sustained human and robotic operations on the lunar surface as part of NASA’s Moon to Mars strategy. Key challenges include variable solar illumination at polar and equatorial regions, extreme thermal environments, and dust driven degradation that limit current surface power systems. The science data needed for resource identification and landing site planning will allow for the successful preparation of crewed Artemis activities and long-term presence. Building on recent missions, current test infrastructure, and emerging power technology pathways, this presentation equips industry, academia, and government teams with the information needed to design robust lunar payloads, reduce development risk, and fully leverage the increasing cadence of CLPS missions. These developments will form a critical technical foundation for long duration lunar presence and future Mars exploration.

lunar power

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator