Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Process Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

TU-FG-201-09: Predicting Accelerator Dysfunction

Purpose: To develop an integrated statistical process control (SPC) framework using digital performance and component data accumulated within the accelerator system that can detect dysfunction prior to unscheduled downtime. Methods: Seven digital accelerators were monitored for twelve to 18 months. The accelerators were operated in a ‘run to failure mode’ with the individual institutions determining when service would be initiated. Institutions were required to submit detailed service reports. Trajectory and text log files resulting from a robust daily VMAT QA delivery were decoded and evaluated using Individual and Moving Range (I/MR) control charts. The SPC evaluation was presented in a customized dashboard interface that allows the user to review 525 monitored parameters (480 MLC parameters). Chart limits were calculated using a hybrid technique that includes the standard SPC 3σ limits and an empirical factor based on the parameter/system specification. The individual (I) grand mean values and control limit ranges of the I/MR charts of all accelerators were compared using statistical (ranked analysis of variance (ANOVA)) and graphical analyses to determine consistency of operating parameters. Results: When an alarm or warning was directly connected to field service, process control charts predicted dysfunction consistently on beam generation related parameters (BGP)– RF Driver Voltage, Gun Grid Voltage, and Forward Power (W); beam uniformity parameters – angle and position steering coil currents; and Gantry position accuracy parameter: cross correlation max-value. Control charts for individual MLC – cross correlation max-value/position detected 50% to 60% of MLCs serviced prior to dysfunction or failure. In general, non-random changes were detected 5 to 80 days prior to a service intervention. The ANOVA comparison of BGP determined that each accelerator parameter operated at a distinct value. Conclusion: The SPC framework shows promise. Long term monitoring coordinated with service will be required to definitively determine the effectiveness of the model. Varian Medical System, Inc. provided funding in support of the research presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Outline for Feasibility Study on a Nuclear Material Accounting and Control System for Measurement of High-Activity Waste at Tokai Reprocessing Plant during Decommissioning

The objective of this collaboration between the DOE/NNSA International Nuclear Security Program (INS) and JAEA is to conduct a feasibility study on nuclear material accounting and control needs and requirements for NDA measurement of high-activity waste at TRP during the decommissioning process. Under this study, both sides will exchange information, perform an assessment of needs and requirements, and develop joint recommendations for development of the A-HMMS.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A HUMAN FACTORS META MODEL FOR U.S. NUCLEAR POWER PLANT CONTROL ROOM MODERNIZATION

Over the last several years, the United States (U.S.) Department of Energy (DOE) has sponsored human factors research and development (R&D) and human factors engineering (HFE) activities through its Light Water Reactor Sustainability (LWRS) program to modernize the main control rooms (MCR) of commercial nuclear power plants (NPP). Idaho National Laboratory (INL), in partnership with numerous commercial nuclear utilities, has conducted some of this R&D to enable the life extension of NPPs (i.e., provide the technical basis for the long-term reliability, productivity, safety, and security of U.S. NPPs). From these activities performed to date, a human factors meta model for U.S. NPP control room modernization can now be formulated. This paper discusses this emergent HFE meta model for NPP control room modernization, with the goal of providing an integrated high level roadmap and guidance on how to perform human factors R&D and HFE for those in the U.S. nuclear industry that are engaging in the process of upgrading their MCRs.

99 GENERAL AND MISCELLANEOUS↗

The Fermilab CMTF cryogenic distribution remote control system

The Cryomodule Test Facility (CMTF) is able to provide the necessary test bed for measuring the performance of Superconducting Radio Frequency (SRF) cavities in a cryomodule (CM). The CMTF have seven 300 KW screw compressors, two liquid helium refrigerators, and two Cryomodule Test Stands (CMTS). CMTS1 is designed for 1.3 GHz cryomodule operating in a pulsed mode (PM) and CMTS2 is for cryomodule operating in Half-Wave (HW) and Continuous Wave (CW) mode. Based on the design requirement, each subsystem has to be far away from each other and be placed in distant locations. Therefore choosing Siemens Process Control System 7-400, DL205 PLC, Synoptic and Fermilab ACNET are the ideal choices for CMTF cryogenic distribution real-time remote control system. This paper presents a method which has been successfully used by many Fermilab distribution cryogenic real-time remote control systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Connecting LWRS Human Factor Engineering R&D to NUREG-0711 Elements and Modification Activities in Nuclear Power Plants

This Report documents the connection between DOE INL LWRS HFE R&D activities and the technical content of NUREG-0711 Results Summary Reports. Since the current and most recent LWRS HFE activities are associated with modernization and modification of nuclear power electric generating stations, this Report will limit its scope to these topics. NUREG-0711 Results Summary Reports content is shared with US nuclear generating stations by INL HFE staff through HFE Technical Reports to identify potential HEDs with planned upgrades. With such information, utilities have confidence that their upgraded HMIs, operating procedures, conduct of operations, and training with the upgraded systems will ensure their continued safe control of the nuclear plant. The utilities use the HFE Technical Reports as basis documents in their licensing processes used to modify the plant (LAR or 10CFR50.59). For plant modifications, LWRS HFE R&D activities commence as early as an agreement is reached between the utility and the LWRS Program staff. The multiple interfaces usually result in the two organizations meeting at INL, at the utility’s site, and at the vendor’s facility. Since there generally is a shortage of utility based HFE experience, INL HFE staff supports the HFE related utility modernization & modification (obsolescence) activities whenever requested.

10 CFR 50.59↗

Cyber security best practices for the nuclear industry

When deploying software based systems, such as, digital instrumentation and controls for the nuclear industry, it is vital to include cyber security assessment as part of architecture and development process. When integrating and delivering software-intensive systems for the nuclear industry, engineering teams should make use of a secure, requirements driven, software development life cycle, ensuring security compliance and optimum return on investment. Reliability protections, data loss prevention, and privacy enforcement provide a strong case for installing strict cyber security policies. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

VERIFICATION OF THE DEFENSE WASTE PROCESSING FACILITY'S (DWPF) PROCESS DIGESTION METHOD FOR THE SLUDGE BATCH 7A QUALIFICATION SAMPLE

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) performs confirmation of the applicability of the digestion method to be used by the DWPF lab for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) receipt samples and SRAT product process control samples. DWPF SRAT samples are typically dissolved using a room temperature HF-HNO{sub 3} acid dissolution (i.e., DWPF Cold Chem Method, see DWPF Procedure SW4-15.201) and then analyzed by inductively coupled plasma - atomic emission spectroscopy (ICP-AES). This report contains the results and comparison of data generated from performing the Aqua Regia (AR), Sodium peroxide/Hydroxide Fusion (PF) and DWPF Cold Chem (CC) method digestions of Sludge Batch 7a (SB7a) SRAT Receipt and SB7a SRAT Product samples. The SB7a SRAT Receipt and SB7a SRAT Product samples were prepared in the SRNL Shielded Cells, and the SRAT Receipt material is representative of the sludge that constituates the SB7a Batch or qualification composition. This is the sludge in Tank 51 that is to be transferred into Tank 40, which will contain the heel of Sludge Batch 6 (SB6), to form the Sb7a Blend composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Safety-Related Instrumentation and Control Pilot Upgrade: Conceptual - Detailed Design Phase Report and Lessons Learned

Historically, regulatory barriers have precluded nuclear plant safety-related (SR) Instrumentation and Control (I&C) system modernizations. These barriers have been largely addressed by industry and United States Nuclear Regulatory Commission (NRC) efforts, including development of the License Amendment Request (LAR) Alternate Review (AR) process for digital I&C upgrades. The U.S. Department of Energy (DOE) and the Idaho National Laboratory (INL) are supporting a SR I&C pilot upgrade at the Limerick Generating Station (LGS) to demonstrate this process and capturing associated lessons learned for the benefit of industry. In 2021, a paper summarizing lessons learned as captured in INL/EXT-20-59809, Safety Related Instrumentation & Control Pilot Upgrade Initial Scoping Phase Implementation Report and Lessons Learned was presented at the 12th NPIC & HMIT conference. It is recommended that readers of this paper review reference 1 or the associated Nuclear Journal paper for context. This paper summarizes activities performed and lessons learned for the conceptual design phase and portions of the detailed design phase as captured in INL/RPT-23-XXXX, “Safety-Related Instrumentation and Control Pilot Upgrade: Conceptual - Detailed Design Phase Report and Lessons Learned.” The portions of the effort covered by reference 2 include conceptual design phase activities from December 2020, through completion in November 2021, and detailed design activities through September 2022. These efforts and associated detailed documentation in reference 3 are intended to support similar industry upgrades as a foundation stone for a Digital Transformation that will improve plant safety, reliability, and operational performance while lowering plant total cost of ownership.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Utility and Industry Perceptions of Control Room Modernization Over the Last 10 Years

Within the current United States (U.S.) nuclear power fleet, main control room modernization (CRM) is an important step towards cost savings. In recent decades, plants have been engaged in upgrades to varying degrees. This process requires a nuanced, balanced, and timely approach that ensures continued safety and long-term sustainability. In 2012 a survey was issued to individuals from the nuclear industry to learn their perspectives on a range of CRM issues. The survey targeted the benefits and challenges for utilities undertaking this process, including the main drivers and barriers to technology upgrades, regulatory compliance, and the effects these factors have on concepts of operations, strategic approaches, and staffing. In 2022, the survey was issued again to understand whether CRM perceptions had changed in the last 10 years. Our findings identify changes in industry thinking from a decade ago. Here we reveal perspective shifts that represent increased optimism and, in some instances, increased doubt regarding the opportunities and challenges inherent in CRM and implementation. We also report nuanced differences in CRM perspectives between utility and surrounding nuclear industry respondents.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next generation information systems

The Information Systems Analysis and Development (ISAD) Team of the Safeguards Systems Group at Los Alamos National Laboratory (LANL) has been developing web based information and knowledge management systems for sixteen years. Our vision is to rapidly and cost effectively provide knowledge management solutions in the form of interactive information systems that help customers organize, archive, post and retrieve nonproliferation and safeguards knowledge and information vital to their success. The team has developed several comprehensive information systems that assist users in the betterment and growth of their organizations and programs. Through our information systems, users are able to streamline operations, increase productivity, and share and access information from diverse geographic locations. The ISAD team is also producing interactive visual models. Interactive visual models provide many benefits to customers beyond the scope of traditional full-scale modeling. We have the ability to simulate a vision that a customer may propose, without the time constraints of traditional engineering modeling tools. Our interactive visual models can be used to access specialized training areas, controlled areas, and highly radioactive areas, as well as review site-specific training for complex facilities, and asset management. Like the information systems that the ISAD team develops, these models can be shared and accessed from any location with access to the internet. The purpose of this paper is to elaborate on the capabilities of information systems and interactive visual models as well as consider the possibility of combining the two capabilities to provide the next generation of infonnation systems. The collection, processing, and integration of data in new ways can contribute to the security of the nation by providing indicators and information for timely action to decrease the traditional and new nuclear threats. Modeling and simulation tied to comprehensive databases are progressions of the tools that can be used in new ways and further developed to enhance the mission of nonproliferation and threat reduction.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Intelligent experiments through real-time AI: Fast Data Processing and Autonomous Detector Control for sPHENIX and future EIC detectors (Phase-I)

With an ever increasing demand for high precision data from modern detectors for discovery science and precision measurements, all major high energy nuclear and particle experiments, current and future, are facing the challenge on how to deal with the large volume of raw data generated from sophisticated state-of-the-art detectors in high rate collisions. These goals need to be balanced with available hardware and cost limits on DAQ (Data AcQuisition system) bandwidth and offline computing resources to capture, store and process the signal events. Two prototypical examples are the upcoming sPHENIX experiment, the DOE next generation heavy ion physics experiment at the Relativistic Heavy Ion Collider at BNL, and the future EIC experiments that are planned to be online circa 2030.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precipitation of Epsilon Particles in Metal Doped Ceria Irradiated with Energetic Ions

Metallic particles precipitated from fission products in oxide fuel matrix (e.g., UO{sub 2}) have a great impact on the thermal and mechanical properties of the fuel. A burn-up of 40 MWd/kg U results in the conversion of 4% of the uranium to approximately 3% fission products and 1% transuranium elements. Epsilon phase is the major metallic phase of the precipitates with a hexagonal-closed packed (HCP) crystal structure. It can exist in a variety of metallic forms in UO{sub 2}, but typically, it consists of five metals: Mo, Pd, Rh, Ru and Tc. Epsilon particles can form over a wide range of stoichiometries in the five metal system. Simulated compositions with Re as a surrogate for Tc have been investigated as a waste form for {sup 99}Tc, an isotope with a long half-life of 2.13 10{sup 5} years and a high solubility under oxidizing conditions in addition to Mo in the corrosion process. There is a pressing need to understand the factors influencing the formation and growth of the metallic phase in fuel. Efforts are currently underway to perform careful neutron irradiation of nuclear fuel under controlled conditions in a test reactor, recover metallic phases that may be present, and characterize the resulting structure and chemistry. Due to the long duration, high cost and radiological concerns associated with neutron irradiation and sample characterizations, ion irradiation studies of a surrogate material with a full control of the processing parameters can emulate different stages of the particle precipitation, which can add a tremendous value to reactor-based studies. This presentation reports our recent ion irradiation results on the metallic particle precipitation under various irradiation and thermal annealing conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Staphylococcus-Infected Tunneled Dialysis Catheters: Is Over-the-Wire Exchange an Appropriate Management Option?

Purpose: Over-the-wire exchange of tunneled dialysis catheters is the standard of care per K/DOQI guidelines for treating catheter-related bacteremia. However, Gram-positive bacteremia, specifically with staphylococcus species, may compromise over-the-wire exchange due to certain biological properties. This study addressed the effectiveness of over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters compared with non-staphylococcus-infected tunneled dialysis catheters. Methods: Patients who received over-the-wire exchange of their tunneled dialysis catheter due to documented or suspected bacteremia were identified from a QA database. Study patients (n = 61) had positive cultures for Staphylococcus aureus, Staphylococcus epidermidis, or coagulase-negative staphylococcus not otherwise specified. Control patients (n = 35) received over-the-wire exchange of their tunneled dialysis catheter due to infection with any organism besides staphylococcus. Overall catheter survival and catheter survival among staphylococcal species were assessed. Results: There was no difference in tunneled dialysis catheter survival between study and control groups (P = 0.46). Median survival time was 96 days for study catheters and 51 days for controls; survival curves were closely superimposed. There also was no difference among the three staphylococcal groups in terms of catheter survival (P = 0.31). The median time until catheter removal was 143 days for SE, 67 days for CNS, and 88 days for SA-infected catheters. Conclusions: There is no significant difference in tunneled dialysis catheter survival between over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters and those infected with other organisms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A review on the sizing and selection of control valves for thermal hydraulics for reactor system applications

This study presents an overview regarding how to model/size, choose, and maintain control valves (CVs) for a reactor system thermal hydraulics experimentation—specifically simulating pipe break(s) and a loss of coolant accident (LOCA) analysis. In a thermal hydraulics test loop, CVs modulate fluid flow according to the control signal generated by the controller to control the process parameter. The selection of a CV in industrial applications involves many factors, including process diversity, safety, and reliability. Further, the key issues and challenges for performing proper mathematical modeling, installation, servicing, and calibration are also discussed for the benefit of operators and end-users. Additionally, this research includes case studies illustrating major plant-level accidents associated with the malfunctioning of valves. Therefore, the study will serve as a knowledge base or reference guide for young professionals and operators who wish to better understand process control applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A physical zero-knowledge object-comparison system for nuclear warhead verification

Zero-knowledge proofs are mathematical cryptographic methods to demonstrate the validity of a claim while providing no further information beyond the claim itself. The possibility of using such proofs to process classified and other sensitive physical data has attracted attention, especially in the field of nuclear arms control. Here we demonstrate a non-electronic fast neutron differential radiography technique using superheated emulsion detectors that can confirm that two objects are identical without revealing their geometry or composition. Such a technique could form the basis of a verification system that could confirm the authenticity of nuclear weapons without sharing any secret design information. More broadly, by demonstrating a physical zero-knowledge proof that can compare physical properties of objects, this experiment opens the door to developing other such secure proof-systems for other applications.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Remote access and automation of SPring-8 MX beamlines

At SPring-8 MX beamlines, a remote access system has been developed and started user operation in 2010. The system has been developed based on an automated data collection and data management architecture utilized for the confirmed scheme of SPring-8 mail-in data collection. Currently, further improvement to the remote access and automation which covers data processing and analysis are being developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic exposure control in pediatric and adult multidetector CT examinations: A phantom study on dose reduction and image quality

The aim of this study was to assess the potential of a modern x,y,z modulation-based automatic exposure control system (AEC) for dose reduction in pediatric and adult multidetector CT (MDCT) imaging and evaluate the quality of the images obtained. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-, 5-, 10-year old child, and adult were scanned with a MDCT scanner, equipped with a modern AEC system. Dose reduction (%DR) was calculated as the percentage difference of the mean modulated and the preset tube current-time product that is prescribed for standard head and body scan protocols. The effect of the tube potential and the orientation of the topogram acquisition on dose reduction were assessed. Image quality was evaluated on the basis of image noise and signal to noise ratio (SNR). The dose reduction values achieved in pediatric phantoms were remarkably lower than those achieved for the adult. The efficiency of the AEC is decreased at 80 kVp compared to higher tube potentials and for helical scans following an anterior posterior (AP-AEC) compared to a lateral (LAT-AEC) topogram acquisition. In AP-AEC scans, the dose reduction ranged between 4.7 and 34.7% for neonate, 15.4 and 30.9% for 1 year old, 3.1 and 26.7% for 5 years old, 1.2 and 58.7% for 10 years old, and 15.5 and 57.4% for adult. In LAT-AEC scans, the corresponding dose reduction ranged between 11.0 and 36.5%, 27.2 and 35.7%, 11.3 and 35.6%, 0.3 and 67.0%, and 15.0 and 61.7%, respectively. AP-AEC scans resulted in a 17.1% and 19.7% dose increase in the thorax of neonate and the pelvis of the 10-year old phantom, respectively. The variation in the measured noise among images obtained along the scanning z axis was lower in AEC activated compared to fixed milliamperes scans. However, image noise was significantly increased (P<.001) and SNR significantly decreased (P<.001) in most AEC activated compared to fixed milliamperes scans. In conclusion, AEC resulted in a (i) substantial dose reduction, which is less pronounced in children compared to adult, (ii) higher dose reduction in scans following a lateral compared to scans following an anterior-posterior topogram acquisition, (iii) increase of image noise and degradation of SNR in the obtained images compared to the fixed milliamperes technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time tumor tracking: Automatic compensation of target motion using the Siemens 160 MLC

Purpose: Advanced high quality radiation therapy techniques such as IMRT require an accurate delivery of precisely modulated radiation fields to the target volume. Interfractional and intrafractional motion of the patient's anatomy, however, may considerably deteriorate the accuracy of the delivered dose to the planned dose distributions. In order to compensate for these potential errors, a dynamic real-time capable MLC control system was designed. Methods: The newly developed adaptive MLC control system contains specialized algorithms which are capable of continuous optimization and correction of the aperture of the MLC according to the motion of the target volume during the dose delivery. The algorithms calculate the new leaf positions based on target information provided online to the system. The algorithms were implemented in a dynamic target tracking control system designed for a Siemens 160 MLC. To assess the quality of the new target tracking system in terms of dosimetric accuracy, experiments with various types of motion patterns using different phantom setups were performed. The phantoms were equipped with radiochromic films placed between solid water slabs. Dosimetric results of exemplary deliveries to moving targets with and without dynamic MLC tracking applied were compared in terms of the gamma criterion to the reference dose delivered to a static phantom. Results: Our measurements indicated that dose errors for clinically relevant two-dimensional target motion can be compensated by the new control system during the dose delivery of open fields. For a clinical IMRT dose distribution, the gamma success rate was increased from 19% to 77% using the new tracking system. Similar improvements were achieved for the delivery of a complete IMRT treatment fraction to a moving lung phantom. However, dosimetric accuracy was limited by the system's latency of 400 ms and the finite leaf width of 5 mm in the isocenter plane. Conclusions: Different experimental setups representing different target tracking scenarios proved that the tracking concept, the new algorithms and the dynamic control system make it possible to effectively compensate for dose errors due to target motion in real-time. These early results indicate that the method is suited to increasing the accuracy and the quality of the treatment delivery for the irradiation of moving tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗