Search NASASearch

SEARCH · Search NASA

Results for “Operational effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,318 records · Page 19

Effect of Turbulence Models on Criticality Conditions in Swirling Flows

The critical state of vortex cores downstream of vortex breakdown has been studied. Base vortical flows were computed using the Reynolds-averaged, axisymmetric Navier-Stokes equations. Standard K - epsilon , RNG and second-order Reynolds stress models were employed. Results indicate that the return to supercriticality is highly dependent on the turbulence model. The K - epsilon model predicted a rapid return of the vortex to supercritical conditions, the location of which showed little sensitivity to changes in the swirl ratio. The Reynolds stress model predicted that the vortex remains subcritical to the end of the domain for each of the swirl ratios employed, and provided results in qualitative agreement with experimental work. The RNG model produced intermediate results, with a downstream movement in the critical location with increasing swirl. Calculations for which area reductions were introduced at the exit in a subcritical flow were also performed using the Reynolds stress model. The structure of the resulting recirculation zone was altered significantly. However, when area reductions were employed within supercritical flows as predicted using the two-equation models, no significant influence on the recirculation zone was noted.

Robert E Spall

Effect of directed energy deposition process parameter on build quality of tantalum

Tantalum is a refractory metal used in a variety of harsh environment applications. Additive manufacturing of tantalum is limited based on its high melting point and affinity for oxygen. Directed Energy Deposition is an additive manufacturing technique with rapid deposition time and compositional flexibility within builds. Additively manufactured tantalum is susceptible to a variety of material and process-based defects. Various lack-of-fusion defects were identified resulting from excessive powder feed rates or insufficient laser power. Oxygen impurities in some samples caused cracking and increased material hardness. Precipitates were identified in the highly oxidized samples which were printed immediately after the build chamber was opened. High-density, low-defect parts were successfully produced. The effects of scan speed, laser power, and powder feed rate on density and defects were analyzed. A processing window was identified for producing high-quality parts which requires adequately high laser power and lower powder feed rate.

DED

U.S. Pacific Coast Workshop Report on Preconstruction Research Recommendations (U.S. Offshore Wind Synthesis of Environmental Effects Research (SEER) Project)

In May 2022, the U.S. Offshore Wind Synthesis of Environmental Effects Research (SEER) project team hosted a stakeholder workshop focused on preconstruction (baseline) research needs for potential floating offshore wind (OSW) energy development on the U.S. Pacific Coast, including California, Oregon, and Washington. Prior to the workshop, the SEER team developed a set of initial synthesized research recommendations that were identified based on a review of relevant, publicly available resources and with advisory group input. The workshop covered three marine life breakout groups on subsequent days to discuss research recommendations related to 1) marine mammals and sea turtles, 2) fish and invertebrates, and 3) birds and bats. As part of the workshop, over a hundred participants from the public and private sectors provided feedback on various aspects of the initial research recommendations, including associated data and knowledge gaps, benefits/limitations of available methods and technologies, and technological advancements or infrastructure needed to address the recommendation. Approximately 1,000 total comments were received on the workshop MURAL boards and were synthesized in this report. Based on workshop feedback, SEER developed a final database of over 500 specific research recommendations based on more than 40 resources. In Fall 2022, the full database and a tool with updated synthesized research recommendations were disseminated on Tethys (https://tethys.pnnl.gov) to assist with informing future funding opportunities and research programming. There is a continued need to improve awareness of the potential environmental effects, monitoring technologies, and management strategies for floating OSW energy development on the U.S. Pacific Coast. Coordination of these activities will require the sustained involvement of multiple stakeholders from across sectors. Beyond the baseline considerations discussed in this workshop, future state-of-the-science activities should be planned to consider research needs across wind energy life cycle phases for all relevant wildlife taxa and associated habitat and ecosystem processes.

17 WIND ENERGY

Comparative neutron-irradiation effects on thermal conductivity degradation and dimensional stability of TiC, TiB 2 , and ZrB 2 at 200–1000 °C

Ultra-high-temperature ceramics (UHTCs), including TiC, Ti 11 B₂, and Zr 11 B₂, show great potential for plasma-facing components due to their excellent high-temperature properties prior to irradiation. However, their response to neutron irradiation remains insufficiently understood, limiting robust assessment of their viability for fusion energy applications. Here, this study examines the thermal conductivity, dimensional stability and microstructure of TiC, TiB₂, and ZrB₂ following neutron irradiation at temperatures of 200–1000 °C and fast neutron fluences of 2.0 × 10 25 to 1.1 × 10 26 n/m 2 (E > 0.1 MeV). Lattice swelling measured by synchrotron X-ray diffraction in all three UHTCs was maximized at 200 °C and decreased with increasing irradiation temperature, with no evidence of amorphization observed at 200 °C. Above 600 °C, significant macroscopic volume swelling was observed in irradiated Ti 11 B₂ and Zr 11 B₂, but not in TiC, likely due to cavity formation in the diborides. The post-irradiation thermal conductivity, measured at the irradiation temperature, ranged from 28 to 45 W/m·K, representing a 34–45% reduction relative to the unirradiated material. Notably, neutron-irradiated UHTCs exhibit recoverable thermal conductivity at elevated temperatures, comparable to ferritic–martensitic steels and potentially superior to W when transmutation effects are considered, highlighting promise for shielding or armor plasma-facing components. At 600 °C, both thermal conductivity degradation and lattice swelling saturated at doses exceeding 2–4 dpa.

fusion materials

EMU Battery/module Service Tool Characterization Study

The power tool which will be used to replace the attitude control system in the SMM spacecraft is being modified to operate from a self contained battery. The extravehicular mobility unit (EMU) battery, a silver zinc battery, was tested for the power tool application. The results obtained during show the EMU battery is capable of operating the power tool within the pulse current range of 2.0 to 15.0 amperes and battery temperature range of -10 to 40 degrees Celsius.

Palandati, C. F.

Effects of Multisensory Virtual Reality Nature on Affect, Presence, and Restorativeness

Virtual reality (VR) can provide access to restorative environments and sensory stimulation for individuals in isolated, confined, and extreme environments. We developed a nature-based VR intervention featuring three scenes (Garden, Forest, Beach) and examined the effects of multisensory augmentation with location-based olfactory, wind, and thermal stimuli (VR+OWT). Over a two-week period, fifty-one participants were assigned to a no-intervention control, standard audiovisual VR, or augmented VR (VR+OWT) condition. Data collection included weekly assessments of affect, stress, and cognitive performance; post-VR measures of affect, presence, and perceived restorativeness; and open-ended feedback. Both VR and VR+OWT groups produced immediate and sustained reductions in negative affect with no sustained systematic benefits on cognitive performance. The addition of olfactory, wind, and thermal stimuli enhanced presence for some scenes; however, feedback indicated that sensory mismatches and stimulus intensity occasionally detracted from the experience and may have contributed to lower coherence ratings in the VR+OWT group. In contrast, the perceived restorativeness of the VR environment was driven primarily by scene content (Garden vs Forest vs Beach) rather than the level of sensory stimulation. These findings support the potential of virtual nature to promote well-being and underscore the importance of coherence across sensory modalities for multisensory augmentation.

Virtual Reality Intervention

Effect of Thermomechanical Processing on the Microstructure, Properties, and Work Behavior of a Ti50.5 Ni29.5 Pt20 High-Temperature Shape Memory Alloy

TiNiPt shape memory alloys are particularly promising for use as solid state actuators in environments up to 300 °C, due to a reasonable balance of proper ties, including acceptable work output. However, one of the challenges to commercializing a viable high-temperature shape memory alloy (HTSMA) is to establish the appropriate primary and secondary processing techniques for fabrication of the material in a required product form such as rod and wire. Consequently, a Ti 50.5 Ni 29.5 Pt 20 alloy was processed using several techniques including single- pass high-temperature extrusion, multiple-pass high-temperature extrusion, and cold drawing to produce bar stock, thin rod, and fine wire, respectively. The effects of heat treatment on the hardness, grain size, room temperature tensile properties, and transformation temperatures of hot- and cold-worked material were examined. Basic tensile properties as a function of temperature and the strain-temperature response of the alloy under constant load, for the determination of work output, were also investigated for various forms of the Ti 50.5 Ni 29.5 Pt 20 alloy, including fine wire.

Grain Size

Hubble space telescope onboard battery performance

The performance of six 88 Ah Nickel-Hydrogen (Ni-H2) batteries that are used onboard in the Hubble Space Telescope (Flight Spare Module (FSM) and Flight Module 2 (FM2)) is discussed. These batteries have 22 series cells per battery and a common bus that would enable them to operate at a common voltage. It is launched on April 24, 1990. This paper reviews: the cell design, battery specification, system constraints, operating parameters, onboard battery management, and battery performance.

Rao, Gopalakrishna M.

The 1988 Goddard Space Flight Center Battery Workshop

This document contains the proceedings of the 21st annual Battery Workshop held at Goddard Space Flight Center, Greenbelt, Maryland on November 1-3, 1988. The Workshop attendees included manufacturers, users, and government representatives interested in the latest developments in battery technology as they relate to high reliability operations and aerospace use. The subjects covered included battery testing methodologies and criteria, life testing of nickel-cadmium cells, testing and operation of nickel-hydrogen batteries in low earth orbit, and nickel-hydrogen technology issues and concerns.

Yi, Thomas Y.

LES-Based Analysis of Film Cooling in a High-Pressure Turbine Rotor Including Effects of Purge and Tip Flow

Accurate modeling of coolant airflows, which form protective films over turbine blades, is essential for designing fuel-efficient and environmentally sustainable gas turbine engines. Excessive coolant reduces thermal efficiency, while insufficient coolant leads to blade overheating and causes damage. Therefore, precise prediction of flow field interactions with cooling air is critical for optimizing turbine performance. This study numerically investigates the cooling effectiveness of purge and film cooling flows within a high-pressure turbine (HPT) rotor using Large Eddy Simulation (LES). The study utilizes NASA Glenn Research Center’s Glenn-HT solver. The simulation models ethe conditions of the Penn State University START rotating rig. A high-fidelity structured mesh comprising up to 800 million cells is employed to resolve high-Reynolds number flow (Re ≈ 350,000) and to capture intricate secondary flow structures, including tip leakage and purge-induced vortices. Film cooling effectiveness computations are highly sensitive to boundary conditions at the cooling holes and to grid resolution. Even with well-resolved grids and included plena, strong mixing challenges traditional eddy viscosity models. To address this, a simplified configuration is simulated: a truncated row of shaped holes on the suction side near the leading edge and a row on the pressure side, both fed from internal plena while the purge slot and tip clearance are also modeled. Two isothermal LES cases are conducted at two distinct wall temperatures, which yield the adiabatic wall temperature and the heat transfer coefficient. The definition and means of computation of the effectiveness is discussed in this paper. The simulations reveal detailed three-dimensional unsteady flow features, including coherent vortical structures and secondary flows originating from the purge cavity. Film cooling effectiveness and Nusselt number distributions are presented for both the blade surface and tip, highlighting regions of elevated heat transfer and complex thermal behavior. These findings underscore the importance of high-resolution LES and realistic boundary conditions in capturing the dynamics of purge and film cooling, offering valuable insights for improving turbine blade design and thermal management strategies.

Secondary Flows

Transient histone deacetylase inhibition reveals cell type invariant and specific effects of chromatin decondensation on irradiation response

Radiation therapy plays a prominent role in breast cancer treatment, but the high doses of radiation damage both healthy and cancerous cells. Therefore, additional research is needed into combination therapies that could preferentially radiosensitize cancer cells compared to surrounding healthy tissue without causing deleterious side effects. Histone deacetylase inhibitor drugs (HDACis) have been tested as radiosensitizers in both basic research and clinical trials, but the long exposure time typically used in these treatments and the lack of matched healthy cell controls often leave aspects of their mechanism of action unclear. Here, we show that transient (2 h) trichostatin A (TSA) treatment of cancerous and non-tumorigenic breast epithelial cell lines increases immediate DNA damage and decreases long term cell viability in both cell types at high radiation doses. Transient TSA treatment also causes an increase in DNA damage signals after 5 Gy X-rays in other cancer and healthy cell types: A375 melanoma cells and BJ5-ta fibroblasts. This suggests that chromatin decompaction acts to increase cellular vulnerability to initial DNA damage from high doses of radiation in a cell type independent manner that does not rely on changes to DNA repair pathways caused by longer TSA treatment. However, responses to lower doses of radiation and long term survival are more cell type specific: only MCF7 cells experience an effect of TSA on DNA damage after 1 Gy X-ray radiation while MCF10a cells experience somewhat more evident cell viability effects of combined TSA and radiation treatment long term.

Li, Heng [Biochemistry & Cellular and Molecular Bi

Improved constraints on hematite refractive index for estimating climatic effects of dust aerosols

Abstract Uncertainty in desert dust composition poses a big challenge to understanding Earth’s climate across different epochs. Of particular concern is hematite, an iron-oxide mineral dominating the solar absorption by dust particles, for which current estimates of absorption capacity vary by over two orders of magnitude. Here, we show that laboratory measurements of dust composition, absorption, and scattering provide valuable constraints on the absorption potential of hematite, substantially narrowing its range of plausible values. The success of this constraint is supported by results from an atmospheric transport model compared with station-based measurements. Additionally, we identify substantial bias in simulating hematite abundance in dust aerosols with current soil mineralogy descriptions, underscoring the necessity for improved data sources. Encouragingly, the next-generation imaging spectroscopy remote sensing data hold promise for capturing the spatial variability of hematite. These insights have implications for enhancing dust modeling, thus contributing to efforts in climate change mitigation and adaptation.

Environmental Sciences & Ecology

Advanced Space Power PEM Fuel Cell Systems

A model showing mass and heat transfer in proton exchange membrane (PEM) single cells is presented. For space applications, stack operation requiring combined water and thermal management is needed. Advanced hardware designs able to combine these two techniques are available. Test results are shown for membrane materials which can operate with sufficiently fast diffusive water transport to sustain current densities of 300 ma per square centimeter. Higher power density levels are predicted to require active water removal.

PEM

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

The Thermal and Kinematic Sunyaev–Zeldovich Effect in Galaxy Clusters and Filaments Using Multifrequency Temperature Maps of the Cosmic Microwave Background A399–A401 Cluster Pair Case Study

We present a multifrequency and multi-instrument methodology to study the physical properties of galaxy clusters and cosmic filaments using cosmic microwave background observations. Our approach enables simultaneous measurement of both the thermal (tSZ) and kinematic Sunyaev–Zeldovich (kSZ) effects, incorporates relativistic corrections, and models astrophysical foregrounds such as thermal dust emission. We do this by jointly fitting a single physical model across multiple maps from multiple instruments at different frequencies, rather than fitting a model to a single Compton-y map. We demonstrate the success of this method by fitting the A399–A401 galaxy cluster pair and filament system using archival data from the Planck satellite and new, targeted deep data from the Atacama Cosmology Telescope, covering 11 different frequencies over 14 maps from 30 GHz to 545 GHz. Our tSZ results are consistent with previous work using Compton-y maps. We measure the line-of-sight peculiar velocities of the cluster–filament system using the kSZ effect and find statistical uncertainties on individual cluster peculiar velocities of ≲600 km s −1 , which are competitive with current state-of-the-art measurements. Additionally, we measure the optical depth of the filament component with a signal-to-noise of 8.5σ and reveal hints of its morphology. This modular approach is well-suited for application to future instruments across a wide range of millimeter and submillimeter wavebands.

Ajay S Gill

Effect of Composition Variation on Isothermal Rapid Curing Resins for Aerospace Applications

To meet the projected demand for single-aisle composite aircraft in 2040, the production rate of these aircraft will need to increase by four to six times what is currently achievable. A composite manufacturing process with the potential to enable the targeted rates is isothermal resin infusion where infusion and cure occur at the same temperature. However, presently there is not an accepted aerospace-grade resin that can support this isothermal infusion process and maintain acceptable resin properties. Therefore, resin development initiatives have designed anionic catalyzed epoxy systems capable of isothermal infusion and rapid cure at a temperature below 100 ˚C in one hour. High-performance aerospace properties are achieved after undergoing a freestanding post-cure. The resins facilitate faster, energy efficient production cycles by reducing the time and temperature required for cure and eliminating temperature ramps typically required of materials used in the aerospace industry. This work discusses several of the developed resin systems and the impact of varying composition on rheological, thermal, and mechanical properties. Carbon fiber composites were fabricated for one composition by resin transfer molding to demonstrate the potential of these isothermal, rapid cure systems for meeting industry needs.

resin transfer molding

Crustal Deformation and Gravitational Effects From Dynamic Ocean Mass Redistribution Impact Projected Sea‐Level Change

As the climate warms, associated changes in ocean dynamics will redistribute sea‐water mass within the ocean, contributing to relative sea‐level change. This mass redistribution will cause additional sea‐level changes due to gravitational self‐attraction, deformation of the solid Earth, and shifts in the Earth's rotation axis (GRD), which are not incorporated in sea‐level projections. Using CMIP6 climate model output, we quantify relative sea‐level changes induced by GRD from ocean‐dynamic mass loading through 2100. These effects act to amplify projected ocean‐dynamic sea‐level patterns, causing sea‐level rise in coastal regions, particularly along wide continental shelves and at high latitudes. On average, the magnitude of such GRD‐induced sea‐level change is equivalent to ∼15% of the signal due to dynamic ocean mass redistribution. Although our results show substantial inter‐model spread, they reveal that GRD‐induced relative sea‐level changes from ocean mass redistribution represent a non‐negligible component of regional sea‐level change and should be considered in projections.

58 GEOSCIENCES