Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pressure transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Liquid level sensor

Potentiometer-type pressure transducer improves liquid level sensing by using the pressure-induced motion of a diaphragm to alter the resistance of the sensor

Matica, S. W.↗

Environmental control system transducer development study

A failure evaluation of the transducers used in the environmental control systems of the Apollo command service module, lunar module, and portable life support system is presented in matrix form for several generic categories of transducers to enable identification of chronic failure modes. Transducer vendors were contacted and asked to supply detailed information. The evaluation data generated for each category of transducer were compiled and published in failure design evaluation reports. The evaluation reports also present a review of the failure and design data for the transducers and suggest both design criteria to improve reliability of the transducers and, where necessary, design concepts for required redesign of the transducers. Remedial designs were implemented on a family of pressure transducers and on the oxygen flow transducer. The design concepts were subjected to analysis, breadboard fabrication, and verification testing.

Brudnicki, M. J.↗

A tethering system for direct measurement of cardiovascular function in the caged baboon

A device suitable for the continuous measurement of physiological activity in large, conscious monkeys has permitted the direct recording of systemic arterial blood pressure and heart rate in caged baboons. The device comprises a lightweight fiberglass backpack, retained in place on the baboon by a thoracic elastic band and shoulder straps, and a flexible stainless steel tether connecting the pack to an electrocannular slip-ring in the top center of the baboon's cage. A chronically indwelling arterial catheter inserted retrograde into the abdominal aorta via the internal iliac artery and connected to a small pressure transducer on the pack provides direct measurement of blood pressure and heart rate. Body fluids can be sampled or drugs administered via an indwelling catheter in the inferior vena cava. Electrical and fluid connections between the fiberglass pack and recording and infusion equipment located outside the cage pass through the flexible tether and remain protected from the subject. The reliability of the tethering system has been demonstrated in physiological, pharmacological, and behavioral experiments with baboons.

Byrd, L. D.↗

Unsteady aerodynamics of an oscillating cascade in a compressible flow field

Fundamental experiments were performed in the NASA Lewis Transonic Oscillating Cascade Facility to investigate and quantify the unsteady aerodynamics of a cascade of biconvex airfoils executing torsion-mode oscillations at realistic reduced frequencies. Flush-mounted, high-response miniature pressure transducers were used to measure the unsteady airfoil surface pressures. The pressures were measured for three interblade phase angles at two inlet Mach numbers, 0.65 and 0.80, and two incidence angles, 0 and 7 deg. The time-variant pressures were analyzed by means of discrete Fourier transform techniques, and these unique data were then compared with predictions from a linearized unsteady cascade model. The experimental results indicate that the interblade phase angle had a major effect on the chordwise distributions of the airfoil surface unsteady pressure, and that reduced frequency, incidence angle, and Mach number had a somewhat less significant effect.

Buffum, Daniel H.↗

The unsteady aerodynamics of an oscillating cascade in a compressible flow field

Fundamental experiments were performed in the NASA Lewis Transonic Oscillating Cascade Facility to investigate and quantify the unsteady aerodynamics of a cascade of biconvex airfoils executing torsion-mode oscillations at realistic reduced frequencies. Flush-mounted, high-response miniature pressure transducers were used to measure the unsteady airfoil surface pressures. The pressures were measured for three interblade phase angles at two inlet Mach numbers, 0.65 and 0.80, and two incidence angles, 0 and 7 deg. The time-variant pressures were analyzed by means of discrete Fourier transform techniques, and these unique data were then compared with predictions from a linearized unsteady cascade model. The experimental results indicate that the interblade phase angle had a major effect on the chordwise distributions of the airfoil surface unsteady pressure, and that reduced frequency, incidence angle, and Mach number had a somewhat less significant effect.

Buffum, Daniel H.↗

SAPT units turn-on in an interference-dominant environment

A stand alone pressure transducer (SAPT) is a credit-card-sized smart pressure sensor inserted between the tile and the aluminum skin of a space shuttle. Reliably initiating the SAPT units via RF signals in a prelaunch environment is a challenging problem. Multiple-source interference may exist if more than one GSE (ground support equipment) antenna is turned on at the same time to meet the simultaneity requirement of 10 ms. A polygon model for orbiter, external tank, solid rocket booster, and tail service masts is used to simulate the prelaunch environment. Geometric optics is then applied to identify the coverage areas and the areas which are vulnerable to multipath and/or multiple-source interference. Simulation results show that the underside areas of an orbiter have incidence angles exceeding 80 deg. For multipath interference, both sides of the cargo bay areas are found to be vulnerable to a worst-case multipath loss exceeding 20 dB. Multiple-source interference areas are also identified. Mitigation methods for the coverage and interference problem are described. It is shown that multiple-source interference can be eliminated (or controlled) using the time-division-multiplexing method or the time-stamp approach.

Peng, W.-C.↗

Observed acoustic and aeroelastic spectral responses of a MOD-2 turbine blade to turbulence excitation

Early results from a recent experiment designed to directly evaluate the aeroacoustic/elastic spectral responses of a MOD-2 turbine blade to turbulence-induced unsteady blade loads are discussed. The experimental procedure consisted of flying a hot-film anemometer from a tethered balloon in the turbine inflow and simultaneously measuring the fluctuating airload and aeroelastic response at two blade span stations (65% and 87% spans) using surface-mounted, subminiature pressure transducers and standard strain gage instrumentation. The radiated acoustic pressure field was measured with a triad of very-low-frequency microphones placed at ground level, 1.5 rotor diameters upwind of the disk. Initial transfer function estimates for acoustic radiation, blade normal forces, flapwise acceleration/displacement, and chord/flapwise moments are presented.

Kelley, N. D.↗

Shuttle Upper Atmosphere Mass Spectrometer Experimental Flight Results

Calibrated pressure measurements for species with mass-to-charge ratios up to 50 amu/e(-) were obtained trom the shuttle upper atmosphere mass spectrometer experiment during re-entry on the STS-35 mission. The principal experimental objective is to obtain measurements of freestream density in the hypersonic rarefied flow flight regime. Data were collected from 180 to about 87 km. However, data above 115 km were contaminated from a source of gas emanating from pressure transdueers connected in parallel to the mass spectrometer. At lower altitudes, the pressure transducer data are compared to the mass spectrometer total pressure with excellent agreement. Near the orifice entrance, a significant amount of CO2 was generated from chemical reactions. The freestream density in the rarefied flow flight regime is calculated using an orifice pressure coefficient model based upon direct simulation Monte Carlo results. This density, when compared with the 1976 U.S. Standard Atmosphere model, exhibits the wavelike nature seen on previous flights using accelerometry. Selected spectra are presented at higher altitudes (320 km) showing the effects of the ingestion of gases from a forward fuselage fuel dump.

Blanchard, R. C.↗

Inlet Flow Distortion and Unsteady Blade Response in a Transonic Axial-Compressor Rotor

This paper describes the unsteady blade surface pressures on the first-stage rotor blades of a two-stage transonic axial flow compressor experiencing inlet flow distortion. This study was conducted to demonstrate the ability of a full annulus unsteady Reynolds-averaged Navier-Stokes numerical technique to predict unsteady pressures on the rotor blades operating in a distorted inflow. A total pressure distortion produced by a variable mesh screen mounted near the inlet was used to excite the unsteady blade loading on the rotor. On-blade pressure transducers were used to measure the unsteady blade surface pressure. These pressures and the resulting transient load on the rotor blades were compared to the numerical prediction. It is important to develop numerical techniques to predict these transient loads to better understand the response of compressor blades to forcing functions. With this enhanced understanding and ability to predict these transient forces, more robust compressors can be developed. In the study, a high definition of the inlet flow distortion was achieved by rotating the distortion screens. In this manner the inlet flow distortion and the distortion at the first stage stator leading edge were measured at approximately every 0.7 degrees. This full annulus high definition of the inlet flow distortion was used as the inlet boundary condition for the numerical technique. The experimental measurements and numerical analyses are highly complementary in this study. Detailed comparisons between the measurements and the numerical analyses indicate that the current numerical procedure calculates the unsteady aerodynamic pressure on the blade surfaces reasonably well. Further, the agreement of the measured and predicted rotor exit flow distortion at the first stage stator leading edge provides verification of the numerical technique.

Rabe, D. C.↗

Time Averaged Pressure Measurement in Fundamentally Unsteady Pressure Gain Combustion Systems

Experimental results and analysis are presented on a technique for obtaining time averaged pressure in the harsh and highly unsteady environment of a pressure gain combustor. The technique utilizes a long, narrow, stand-off tube leading from the measurement point to a pressure transducer. The tube damps the fluctuations (which may result from strong shocks and/or detonations) and thermally isolates the transducer. The damping must be sufficient to ensure that net gasdynamic work exchange does not occur on the fluid in the stand-off tube, and it must be linear to insure that the time-averaged pressure at the transducer end is the same as that at the combustor end. The paper presents experimental and analytical results from two rigs which indicate that, using certain stand-off tube dimensions, these criteria are met. Physical rational for the tube dimensions (i.e., guidelines) are also presented.

detonation↗

Transonic buffet behavior of Northrop F-5A aircraft

Flight tests were performed on an F-5A aircraft to investigate the dynamic buffet pressure distribution on the wing surfaces and the responses during a series of transonic maneuvers called wind-up turns. The conditions under which the tests were conducted are defined. The fluctuating buffet pressure data on the right wing of the aircraft were acquired by miniaturized semiconductor-type pressure transducers flush mounted on the wing. Processing of the fluctuating pressures and responses included the generation of the auto- and cross-power spectra, and of the spatial correlation functions. An analytical correlation procedure was introduced to compute the aircraft response spectra based on the measured buffet pressures.

Hwang, C.↗

Homogeneous nucleation of ethanol and n-propanol in a shock tube

The condensation by homogeneous nucleation of ethanol (200 proof) and of n-propanol (99.98%) carried at small mole fraction in dry air (99.995%) was studied in the unsteady, isentropic expansion of a shock tube. Samples of the vapor at different partial pressures in dry air at room temperature were expanded into the liquid coexistence regime of the condensing species. A Kristler pressure transducer and Rayleigh light scattering were used to measure the pressure in the expansion and the onset of condensation. Condensation was observed at different locations between 0.15 and 1 m upstream of the diaphragm location, which correspond to different cooling rates of of the vapor samples about 50 to 10 C/ms.

Peters, F.↗

Noise generated by flow through large butterfly valves

A large butterfly valve (1.37 m diam) was acoustically tested to measure the noise generated and propagating in both the upstream and downstream directions. The experimental investigation used wall mounted pressure transducers to measure the fluctuating component of the pipe static pressure upstream and downstream of the valve. Microphones upstream of the pipe inlet and located in a plenum were used to measure the noise radiated from the valve in the upstream direction. Comparison of the wall pressure downstream of the valve to a prediction were made. Reasonable agreement was obtained with the valve operating at a choked condition. The noise upstream of the valve is 30 dB less than that measured downstream.

Huff, Ronald G.↗

A Survey of Measurements and Measuring Techniques in Rapidly Distorted Compressible Turbulent Boundary Layers

A wide range of recent work on compressible turbulent boundary layers is described. Special attention was paid to flows with rapid changes in pressure including flows with shock waves, curved walls, and expansions. The application of rapid distortion theory to flows transversing expansion and shock waves is reviewed. This is followed by an account of experiments aimed at elucidating the large scale structures present in supersonic boundary layers. The current status of laser-Doppler and hot-wire anemometry in supersonic flow is discussed, and a new interferometric technique for the determination of wall-stress is described. The use of small pressure transducers to deduce information about the structure of zero pressure-gradient and severely perturbed boundary layers is investigated. Finally, there is an extension of the data presentation of AGARDographs 223, 253 and 263 to cover rapidly distorted boundary layers.

Fernholz, H. H.↗

Fluid Dynamics of a Pressure Reducing Inlet

Instruments for the monitoring of hazardous gases in and near the space shuttle collect sample gas at pressures on the order of one atmosphere and analyze their properties in an ultra-high vacuum by means of a quadrupole-mass-spectrometer partial pressure transducer. Sampling systems for such devices normally produce the required pressure reduction through combinations of vacuum pumps, fluid Tees and flow restrictors (e.g. orifices, sintered metal frits or capillaries). The present work presents an analytical model of the fluid dynamics of such a pressure reduction system which enables the calculation of the pressure in the receiver vessal in terms of system parameters known from the specifications for a given system (e.g. rated pumping speeds of the pumping hardware and the diameters of two orifices situated in two branches of a fluid Tee). The resulting formulas will expedite the fine tuning of instruments now under development and the design of later generations of such devices.

Russell, John M.↗

Development of an in-vitro circulatory system with known resistance and capacitance

An in-vitro (hydrodynamic) model of the circulatory system was developed. The model consisted of a pump, compliant tubing, and valves for resistance. The model is used to simulate aortic pressure and flow. These parameters were measured using a Konigsburg Pressure transducer and a Triton ART2 flow probe. In addition, venous pressure and flow were measured on the downstream side of the resistance. The system has a known compliance and resistance. Steady and pulsatile flow tests were conducted to determine the resistance of the model. A static compliance test was used to determine the compliance of the system. The aortic pressure and flow obtained from the hydrodynamic model will be used to test the accuracy of parameter estimation models such as the 2-element and 4-element Windkessel models and the 3-element Westkessel model. Verifying analytical models used in determining total peripheral resistance (TPR) and systemic arterial compliance (SAC) is important because it provides insight into hemodynamic parameters that indicate baroreceptor responsiveness to situations such as changes in gravitational acceleration.

NASA Discipline Cardiopulmonary↗

Overview of the Dragonfly Entry Aerosciences Measurements (DrEAM) Suite

NASA Ames and Langley arepartnering with DLR to propose acomprehensive instrumentation suite known as the Dragonfly Entry Aerosciences Meas-urements (DrEAM). DrEAM being the first competed mission to fly EDL instrumentation as part of NASA’s Engineering Science Investigation (ESI).DrEAM will provide key aerothermodynamicdata and performance analysisfor Dragonfly’s forebody and backshell therma lprotection system (TPS),and also includes a DLR-provided Data Acquisition System(DAS).Titan’s atmosphere predominantly consists of nitro-gen (~98% by mole) with small amounts of methane(~2% by mole)and other trace gases. CN is a strong ra-diator and is found in nonequilibriumconcentrationsfor Titan entry. The accurate modeling of nonequilibrium CN radiation has proven to be a difficult task. Prompted by the Huygensmission, many experimental campaigns and analyses were performed to better understand the aerothermal environments experience by the probe dur-ing Titan entry[1].However, the Huygens probe carried no heatshieldinstrumentation. Therefore,the DrEAM instrumentation suite will significantly advance the state-of-the-art not only by documenting theenviron-ment and performance of Dragonfly’sentry system but also by making keymeasurements in Titan’s atmos-phere for thefirst time, thus providing new benchmark dataapplicable to entry science more generally. Current Measurement Goals: Aerothermal envi-ronments and TPS responsewill be measured using sen-sors similarto the Mars Entry, Descent, and Landing In-strumentation2 (MEDLI2) Integrated Sensor Plug(MISP) and the COMbined Aerothermaland Radiome-ter Sensor (COMARS)suite[2], with the latter supplied by DLR.For MEDLI2, MISP usedembedded thermo-couples (TCs) todirectly measure in-depth temperature of theTPS at several locations,which can also be used to infer surface environmentsvia inverse analysis. For DrEAM, the MISPstyle plugswill be known as Drag-onfly Sensors for Aero-Thermal Reconstruction (Drag-STR)plugs. On Schiaparelli, the COMARSsuite in-cludedthree total surface-mounted heatflux sensors, three pressure sensors, and one radiometer. For DrEAM, the COMARS package will be known as COmbined Sensor System for Titan Atmosphere (COSSTA). Atmospheric density measurements and capsuleaerodynamic data will be obtained throughthe onboard Inertial Measurement Unit (IMU),supple-mented by pressure transducers similar tothose used by the MEDLI Mars Entry AtmosphericData System (MEADS).The DrEAM pressure sensors will be known as Dragonfly Atmospheric Flight Transducers(DrAFT) Both DragSTR and DrAFThave flight heritagefrom MISP and MEADS on the MSLand Mars 2020mis-sions, and the COMARS suite successfullyflew on the ESA Schiaparelli EDMlander. A preliminary layout of the sensors is shown in Fig. 1. Because Dragonflyuses the same aeroshell provider (i.e., LockheedMartin) and materials for the TPS,with what are expected to be sim-ilar thicknesses as MSL and Mars 2020on both the heat shield and backshell, theDrEAMinstrumentation will look to utilize the same techniques and processes as de-veloped byMEDLI and MEDLI2for vehicle integra-tion. This commonality alsoenables DrEAMto lever-age the extensiveground test qualifications performed forMEDLI and MEDLI2 and claim substantial heritagefor this system.

A Brandis↗