Multiple-sample holder for IC testing
Carrousel tray speeds up testing process by feeding mass spectrometer up to 12 sealed integrated circuit packages in rapid succession for analysis of contaminants and total gas composition.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Carrousel tray speeds up testing process by feeding mass spectrometer up to 12 sealed integrated circuit packages in rapid succession for analysis of contaminants and total gas composition.
The Mars Geochemical Instrument, MarGI, was developed to provide a comprehensive analysis of the rocks and surface material on Mars. The instrument combines Differential Thermal Analysis (DTA) with miniature Gas Chromatography-Ion Mobility Spectrometry (GC-IMS) to identify minerals, the presence and state of water, and organic compounds. Miniature pyrolysis ovens are used to both, conduct DTA analysis of soil or crushed rocks samples, and pyrolyze the samples at temperatures up to 1000 degrees C for GC-IMS analysis of the released gases. This combination of analytical processes and techniques, which can characterize the mineralogy of the rocks and soil, and identify and quantify volatiles released during pyrolysis, has applications across a wide range of target sites including comets, planets, asteroids, and moons such as Titan and Europa. The MarGI analytical approach evolved from the Cometary Ice and Dust Experiment (CIDEX) selected to fly on the Comet Rendezvous Asteroid Flyby Mission (CRAF).
Sterile delivery devices can be created by integrating a medicine delivery instrument with surfaces that are coated with germicidal and anti-fouling material. This requires that a large-surface-area template be developed within a constrained volume to ensure good contact between the delivered medicine and the germicidal material. Both of these can be integrated using JPL-developed silicon nanotip or cryo-etch black silicon technologies with atomic layer deposition (ALD) coating of specific germicidal layers. The application of semiconductor processing techniques and technologies to the problems of fluid manipulation and delivery has enabled the integration of chemical, electrical, and mechanical manipulation of samples all within a single microfluidic device. This approach has been successfully applied at JPL to the automated processing, detection, and analysis of minute quantities (parts per trillion level) of biomaterials to develop instruments for in situ exploration or extraterrestrial bodies. The same nanofabrication techniques that are used to produce a microfluidics device are also capable of synthesizing extremely high-surface-area templates in precise locations, and coating those surfaces with conformal films to manipulate their surface properties. This methodology has been successfully applied at JPL to produce patterned and coated silicon nanotips (also known as black silicon) to manipulate the hydrophilicity of surfaces to direct the spreading of fluids in microdevices. JPL's ALD technique is an ideal method to produce the highly conformal coatings required for this type of application. Certain materials, such as TiO2, have germicidal and anti-fouling properties when they are illuminated with UV light. The proposed delivery device contacts medicine with this high-surface-area black silicon surface coated with a thin-film germicidal deposited conformally with ALD. The coating can also be illuminated with ultraviolet light for the purpose of sterilization or identification of the medicine itself. This constrained volume that is located immediately prior to delivery into a patient, ensures that the medicine delivery device is inherently sterile. An additional benefit to integrating a high-surface-area template within the fluid channel of a medicine delivery device is that one can envision a number of different functional coatings that could facilitate the capture and analysis of either microbial contaminants or the medicine itself. For example, one could attach antibodies or some other binding agent with a specific affinity to the silicon nanotip template. Once a target molecule or microbe is bound to the high-surface- area template, one could use an optical analytical technique such as fluorescence or adsorption to determine the identity and potentially the concentration of the species of interest. By illuminating the bound species from the back, it may also be possible to probe only the molecules with an evanescent wave, making detection of the species from the front side of the device much simpler.
Repeated measurements of the composition of the Mars atmosphere from Curiosity Rover yield a (40)Ar/N2 ratio 1.7 times greater and the (40)Ar/(36)Ar ratio 1.6 times smaller than the Viking Lander values in 1976. The unexpected change in (40)Ar/N2 ratio probably results from different instrument characteristics although we cannot yet rule out some unknown atmospheric process. The new (40)Ar/(36)Ar ratio is more aligned with Martian meteoritic values. Besides Ar and N2 the Sample Analysis at Mars instrument suite on the Curiosity Rover has measured the other principal components of the atmosphere and the isotopes. The resulting volume mixing ratios are: CO2 0.960(+/- 0.007); (40)Ar 0.0193(+/- 0.0001); N2 0.0189(+/- 0.0003); O2 1.45(+/- 0.09) x 10(exp -3); and CO 5.45(+/- 3.62) x 10(exp 4); and the isotopes (40)Ar/(36)Ar 1.9(+/- 0.3) x 10(exp 3), and delta (13)C and delta (18)O from CO2 that are both several tens of per mil more positive than the terrestrial averages. Heavy isotope enrichments support the hypothesis of large atmospheric loss. Moreover, the data are consistent with values measured in Martian meteorites, providing additional strong support for a Martian origin for these rocks.
The Europan Molecular Indicators of Life Investigation (EMILI) is an instrument concept being developed for the Europa Lander mission currently under study. EMILI will meet and exceed the scientific and technical/resource requirements of the organic composition analyzer identified as a core instrument on the Lander. EMILI tightly couples two complementary analytical techniques, based on 1) liquid extraction and processing with capillary electrophoresis and 2) thermal and chemical extraction with gas chromatography, to robustly detect, structurally characterize, and quantify the broadest range of organics and other Europan chemicals over widely-varying concentrations. Dual processing and analysis paths enable EMILI to perform a thorough characterization of potential molecular biosignatures and contextual compounds in collected surface samples. Here we present a summary of the requirements, design, and development status of EMILI with projected scientific opportunities on the Europa Lander as well as on other potential life detection missions seeking potential molecular biosignatures in situ.
Potential opportunities to return to Enceladus in Discovery and Flagship class missions inspire development of next-generation instruments and creative approaches to sample collection, sample analysis, and data analysis and transmission strategies. Mass spectrometers (MS) are ideally suited to future Enceladus missions due to their analytical power in identifying a range of molecular and ionic compositions – including complex organics – and potentially astrobiologically-important features such as isotope ratios, chirality, and enantiomeric excess. However, long communication delays from Enceladus and limited bandwidth limits the data transmission from these higher-data-volume instruments, likely delaying mission-related response to new data. We explore the utility of data science and machine learning (ML) on isotope ratio (IR)MS data collected from laboratory analogs of Enceladus to: 1) process data quickly for rapid ground-based analyses, 2) understand if compositional and biosignature information could be extracted from IRMS data, and 3) evaluate whether onboard ML techniques could improve sample analysis, cadence, and transmission prioritization. Laboratory analogs analyzed isotopes of volatile CO2 that interacted with seawaters of varying composition, and include both abiotic and biotic (microbially-influenced) experiments. Enceladus’s alkaline oceans promote speciation of carbon into multiple forms (e.g., H2CO3 / CO2, HCO3-, and CO32-), each of which could be isotopically fractionated by abiotic or biotic reactions. Large (>2‰) changes in carbon isotopes (δ13C) are observed from some biotic experiments inoculated with complex microbial ecosystems relative to the abiotic seawaters. ML training and classification suggests that microbial samples can be distinguished from abiotic samples, yet that a broad range of microbial experiments are necessary to train ML models to cover a range of complexities including disequilibria, and isotopic and compositional fractionation.
A few weeks after their return to Earth, several Apollo 17 regolith sample splits and one Apollo 17 basalt were frozen at -20˚C (under dry gaseous N2 like all other pristine Apollo samples), and have remained essentially unstudied within the Apollo sample collection at NASA’s Johnson Space Center (JSC). As part of the Apollo Next Generation Sample Analysis (ANGSA) project, these frozen samples were selected for consortium study in 2019. Although the samples themselves were kept at -20˚C for nearly 50 years, the JSC Curation office has lacked a facility for processing frozen samples under pristine Apollo processing conditions. A temporary lab for this work was designed, built, and tested. Procedures were then developed for working in this unique environment, and the facility was sucessfully used to process the frozen Apollo samples for scientific allocation.
It is pointed out that the exploration and characterization of comets can play a fundamental role in solar system science. Comets are probably primitive products of processes which occurred in the preplanetary solar nebula. The impending return of Halley's comet in 1986 provides an opportunity for a study of comets, and five spacecraft will be launched to intercept Halley. These spacecraft include two sent by the USSR, two by Japan, and one by the European Space Agency (ESA). NASA has recommended two programs for the exploration and characterization of comets. The first mission considered would be a rendezvous with a short-period comet, while the second mission would provide for the return to earth of a sample of the volatile and nonvolatile constituents of the coma of a comet. Developments related to these plans are discussed.
This talk will cover the important steps involved in the data science and knowledge discovery process: • Initial fact gathering (interview domain experts, review reports, articles, state-of-the-art) • Identify the problem (prediction, classification, statistical analysis, etc.) • Survey supporting data sources • Understand the data (numerical, categorical, text, sampling rate, data quality issues, etc.) • Selecting relevant features and sources • Acquire the data (set up agreements with the data stewards, APIs to download, etc.) • Merge data sources (temporal, spatial, common key, other ontologies...) • Feature Engineering (non linear domain knowledge or physics-based relationships) • Build data processing pipeline (may need to tap into data stream, develop parallel processing algorithm, federated learning etc.) • Build model and test (tune hyper-parameters, cross validation.) • Analyze/Validate results (do the results make sense. Does it answer the original question). • Deploy/Publish (Monitor and assess benefits)
The Space Shuttle Thermal Protection System (TPS) tiles and blankets are waterproofed using DimethylEthoxySilane (DMEX) in the Orbiter Processing Facilities (OPF). DMES has a Threshold Limit Value (TLV) for exposure of personnel to vapor concentration in air of 0.5 ppm. The OPF high bay cannot be opened for normal work after a waterproofing operation until the DMES concentration is verified by measurement to be below the TLV. On several occasions the high bay has been kept closed for up to 8 hours following waterproofing operations due to high DMES measurements. In addition, the Miran 203 and Miran 1 BX infrared analyzers calibrated at different wavelengths gave different readings under the same conditions. There was reason to believe that some of the high DMES concentration readings were caused by interference form water and ethanol vapors. The Toxic Vapor Detection Laboratory (TVDL) was asked to test the existing DMES instruments and identify the best qualified instrument. In addition the TVDL was requested to develop instrumentation to ensure the OPF high bay could be opened safely as soon as possible after a waterproofing operation. A Fourier Transform Infrared (FTIR) spectrophotometer instrument developed for an earlier project was reprogrammed to measure DMES vapor along with ethanol, water, and several common solvent vapors. The FTIR was then used to perform a series of laboratory and field tests to evaluate the performance of the single wavelength IR instruments in use. The results demonstrated that the single wavelength IR instruments did respond to ethanol and water vapors, more or less depending on the analytical IR wavelength selected. The FTIR was able to separate the responses to DMES, water and ethanol, and give consistent readings for the DMES vapor concentration. The FTIR was then deployed to the OPF to monitor real waterproofing operations. The FTIR was also used to measure the time for DMES to evaporate from TPS tile under a range of humidity conditions in controlled laboratory tests. The combination of laboratory and field tests with the FTIR instrument demonstrated superior sensitivity, ability to reject interference from water and ethanol vapors, ruggedness to be transported from the lab to the OPF and set up without special procedures or degradation of performance. The multiple component vapor analysis algorithm was developed at KSC and incorporates automatic baseline correction and shape fitting of the spectra. The analysis for DMES, TetraMethylDiSiloxane (TMDS), ethanol, methanol, isopropanol, and baseline parameters uses 161 points per sample at 4 cm(exp -1) resolution, and processes an eight scan sample every ten seconds. The standard deviation of the measurements is 0.013 ppm and the upper linear limit is 125 ppm DMES. Based on successful demonstration of capabilities we produced three mobile instrument carts to be used in each OPF to support future waterproofing operations. The design and building of the 'DMES Carts' were accomplished in Fiscal year 1995.
The successful design and fabrication of metallic cryotanks for commercial aviation applications require lightweight, durable materials capable of withstanding high pressures and cryogenic temperatures through tens of thousands of thermomechanical refueling cycles. Flow forming is an advanced manufacturing technique that offers high-rate production and scalability for fabricating integrally stiffened cylinders suitable for cryotank applications. This work establishes the durability of flow-formed aluminum alloys by characterizing their fatigue life performance under conditions that mimic cryotank refueling cycles. Residual stresses in flow-formed aluminum-lithium (Al-Li) 2195-T6 cylinders were assessed using the contour method and found to be minimal. Fatigue life testing was conducted on flow-formed Al-Li 2195-T6 at room temperature and cryogenic temperatures (-321°F [-196°C]), with wrought Al-Li 2195-T6 serving as a baseline for comparison. Results showed that flow-formed materials exhibited fatigue performance comparable to or better than wrought materials, with no statistically significant differences observed between different specimen orientations relative to processing directions. Fractography revealed reduced delaminations in the flow-formed Al-Li 2195 samples as compared to wrought, indicating potential improvement to the microstructure that could result in improved service properties. Texture analysis using electron backscattered diffraction (EBSD) indicated recrystallization during heat treatment, potentially contributing to reduced delamination susceptibility. These findings demonstrating flow-formed material durability coupled with the high manufacturing efficiency of flow forming, makes flow forming an attractive process to produce aircraft cryotanks.
Materials analyses of key forensic evidence helped unlock the mystery of the loss of space shuttle Columbia that disintegrated February 1, 2003 while returning from a 16-day research mission. Following an intensive four-month recovery effort by federal, state, and local emergency management and law officials, Columbia debris was collected, catalogued, and reassembled at the Kennedy Space Center. Engineers and scientists from the Materials and Processes (M&P) team formed by NASA supported Columbia reconstruction efforts, provided factual data through analysis, and conducted experiments to validate the root cause of the accident. Fracture surfaces and thermal effects of selected airframe debris were assessed, and process flows for both nondestructive and destructive sampling and evaluation of debris were developed. The team also assessed left hand (LH) airframe components that were believed to be associated with a structural breach of Columbia. Analytical data collected by the M&P team showed that a significant thermal event occurred at the left wing leading edge in the proximity of LH reinforced carbon carbon (RCC) panels 8 and 9. The analysis also showed exposure to temperatures in excess of 1,649 C, which would severely degrade the support structure, tiles, and RCC panel materials. The integrated failure analysis of wing leading edge debris and deposits strongly supported the hypothesis that a breach occurred at LH RCC panel 8.
Higher harmonic blade feathering for helicopter vibration reduction is considered. Recent wind tunnel tests confirmed the effectiveness of higher harmonic control in reducing articulated rotor vibratory hub loads. Several predictive analyses developed in support of the NASA program were shown to be capable of calculating single harmonic control inputs required to minimize a single 4P hub response. In addition, a multiple-input, multiple-output harmonic control predictive analysis was developed. All techniques developed thus far obtain a solution by extracting empirical transfer functions from sampled data. Algorithm data sampling and processing requirements are minimal to encourage adaptive control system application of such techniques in a flight environment.
This study is a continuation of the summer of 1994 NASA/ASEE Summer Faculty Fellowship Program. This effort is a portion of the ongoing work by the Biophysics Branch of the Marshall Space Flight Center. The work has focused recently on the separation of macromolecules using capillary electrophoresis (CE). Two primary goals were established for the effort this summer. First, we wanted to use capillary electrophoresis to study the electrohydrodynamics of a sample stream. Secondly, there was a need to develop a methodology for using CE for separation of DNA molecules of various sizes. In order to achieve these goals we needed to establish a procedure for detection of a sample plug under the influence of an electric field Detection of the sample with the microscope and image analysis system would be helpful in studying the electrohydrodynamics of this stream under load. Videotaping this process under the influence of an electric field in real time would also be useful. Imaging and photography of the sample/background electrolyte interface would be vital to this study. Finally, detection and imaging of electroosmotic flow and pressure driven flow must be accomplished.
The Oxygen and Volatile Extraction Node (OVEN) is a subsystem within the Regolith & Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) project. The purpose of the OVEN subsystem is to release volatiles from lunar regolith and extract oxygen by means of a hydrogen reduction reaction. The complete process includes receiving, weighing, sealing, heating, and disposing of core sample segments while transferring all gaseous contents to the Lunar Advanced Volatile Analysis (LAVA) subsystem. This document will discuss the design and performance of the OVEN Field Demonstration Unit (FDU), which participated in the 2012 RESOLVE field demonstration.
Biological experiments on the ISS are frequently frozen at ultra-low temperatures on orbit prior to return to Earth for analysis. Recording temperatures during the freezing process, and subsequent handling to the point of post-flight processing, can provide important information of sample integrity to the scientist. The MadgeTech Cryo-Temp Data Logger has been modified for space flight applications by the Payload Development Team at Kennedy Space Center. This ultra-low temperature data logger is rated for temperatures from -86 C to +35 C with 0.1 C resolution and +/-1 C accuracy, but has been successfully tested at Kennedy Space Centers Cryogenic Lab down to -100 C. The logger provides date and time stamped temperature recordings and can be set with logging intervals from 5 seconds up to 30 minutes using the MadgeTech Data Logger Software. Data can be recorded, depending on logging interval, for greater than 90 days. The Cryo-Temp Data logger will first be flown on Space X-12 in the BRIC-Petri Dish Fixation Unit (PDFU) canister hardware, recording temperature data for a Space Life and Physical Sciences (SLPS) flight experiment. The modified Cryo-Temp Data Logger is small in size (Figure 1) and is the ideal temperature monitoring solution for any application involving independent temperature data logging.
Understanding biological impacts from spaceflight hazards and the subsequent development of countermeasures are a high priority to enable humanity to venture back to the Moon, and then to Mars and beyond. Experiments have been conducted with model organisms flown to space and analogous investigations terrestrially, to identify biological mechanistic impacts from spaceflight hazards and to develop mitigation countermeasures, thus contributing towards basic and applied science goals. However, sending organisms into space is a costly endeavor. To maximize scientific return, all biospecimens not required by spaceflight-relevant Principal Investigators are harvested, preserved, and archived in the NASA Biological Institutional Scientific Collection (NBISC). Biospecimens are collected and preserved according to well-established standard operating procedures to maintain scientific quality and are available on-request by the international scientific community. NBISC currently stores over 32,000 biospecimens from Shuttle, International Space Station, and ground-based space analog investigations. Tissue sharing has resulted in at least 33 publications since 2011 and 51 requests since 2016. Many requests for NBISC biospecimens come from first-time investigators who subsequently submit grants as their point-of-entry into the field of spaceflight biology and health. The NBISC biorepository is part of the NASA ‘Open Science for Life in Space’ collaborative group of projects, which includes NASA Genelab, the Space Biology Program’s Biospecimen Sharing Program, Physical Sciences Informatics, and the Ames Life Sciences Data Archive. NBISC biospecimens have been awarded to NASA Genelab, who then generated various open access science ‘omics datasets through the GeneLab Sample Processing laboratory, with resulting data widely used for biological study. Other NBISC biospecimen awards have led to studies on fecal microbiome analysis, DNA damage analysis using single-cell DNA sequencing, enzymatic-pathway identification involved in spaceflight muscle atrophy, and characterization of ocular morphological changes. Of note, NBISC is expanded to include a new Space Microbial Culture Collection (SMCC) for the collection, identification, documentation, long-term preservation, and distribution of space-related microbial isolates.
At NASA, we are investigating nondestructive evaluation (NDE) and structural health monitoring (SHM) techniques to detect precursors of thermal runaway failure in lithium metal based lithium ion batteries (LIB). The approach is centered on computational simulation models to guide inspection and aid in interpretation of results. Since lithium metal LIBs have combinations of solid and fluid-filled porous materials, obtaining accurate material properties is both challenging and critical for successful simulation of battery inspection. To this end, we investigated a multi-verification approach for material characterization of thin battery components. First, a laser Doppler vibrometer (LDV) was used to measure guided wave fields in thin (microns-thick) battery components subject to broadband excitation. The time-space wavefield data was converted to frequency-wave number data to extract guided wave dispersion curves. A data visualization and post processing graphics user interface (GUI) was developed at NASA to aid the data exploration and analysis. Due to the thinness of the samples, low frequency-thickness-product plate wave approximations allowed for the calculation of closed-form solutions for material elastic property estimation. These approximations were then verified by calculating the Lamb wave solutions using the previously obtained material properties. Finally, the estimated elastic material properties were implemented in a COMSOL simulation model, and dispersion curves were extracted from simulation results. The dispersion curves and derived material properties were then compared to the analysis results from the experimental data. These comparisons informed on the accuracy of the measured material properties and helped demonstrate the accuracy of the finite element analysis (FEA) computational models. This assessment will prove vital when we start simulating more complex multi-layer components and poroelastic media. This paper gives a brief background of the problem space, outlines the workflow for data analysis and verification, shows results from the workflow, and gives an overview of future plans for simulation of lithium metal LIB inspection.