Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Radiation-Hardness Data For Semiconductor Devices

Document presents data on and analysis of radiation hardness of various semiconductor devices. Data specifies total-dose radiation tolerance of devices. Volume 1 of report covers diodes, bipolar transistors, field effect transistors, silicon controlled rectifiers and optical devices. Volume 2 covers integrated circuits. Volume 3 provides detailed analysis of data in volumes 1 and 2.

Price, W. E.↗

Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗

Radiation Effects on DC-DC Converters

In this work, several DC-DC converters were designed and built. The converters are Buck Buck-Boost, Cuk, Flyback, and full-bridge zero-voltage switched. The total ionizing dose radiation and single event effects on the converters were investigated. The experimental results for the TID effects tests show that the voltages of the Buck Buck-Boost, Cuk, and Flyback converters increase as total dose increased when using power MOSFET IRF250 as a switching transistor. The change in output voltage with total dose is highest for the Buck converter and the lowest for Flyback converter. The trend of increase in output voltages with total dose in the present work agrees with those of the literature. The trends of the experimental results also agree with those obtained from PSPICE simulation. For the full-bridge zero-voltage switch converter, it was observed that the dc-dc converter with IRF250 power MOSFET did not show a significant change of output voltage with total dose. In addition, for the dc-dc converter with FSF254R4 radiation-hardened power MOSFET, the output voltage did not change significantly with total dose. The experimental results were confirmed by PSPICE simulation that showed that FB-ZVS converter with IRF250 power MOSFET's was not affected with the increase in total ionizing dose. Single Event Effects (SEE) radiation tests were performed on FB-ZVS converters. It was observed that the FB-ZVS converter with the IRF250 power MOSFET, when the device was irradiated with Krypton ion with ion-energy of 150 MeV and LET of 41.3 MeV-square cm/mg, the output voltage increased with the increase in fluence. However, for Krypton with ion-energy of 600 MeV and LET of 33.65 MeV-square cm/mg, and two out of four transistors of the converter were permanently damaged. The dc-dc converter with FSF254R4 radiation hardened power MOSFET's did not show significant change at the output voltage with fluence while being irradiated by Krypton with ion energy of 1.20 GeV and LET of 25.97 MeV-square cm/mg. This might be due to fact that the device is radiation hardened.

Zhang, De-Xin↗

A portable absorbed dose measuring instrument with gamma discrimination

The characteristics of an electronic instrument for measuring the radiation dose absorbed by tissues are presented. The detector is a sphere of tissue-equivalent plastic with a single wire located on a diameter of the sphere. The electronic circuits and method of operation of the detector are described. Advantages are the small size and easy portability plus ability to selectively measure neutron and gamma plus neutron events.

Quam, W. M.↗

Deposition and dose from the 18 May 1980 eruption of Mount St. Helens

The downwind deposition and radiation doses was calculated for the tropospheric part of the ash cloud from the May 18, 1980 eruption of Mount St. Helens, by using a large cloud diffusion model. The naturally occurring radionnuclides of radium and thorium, whose radon daughters normally seep very slowly from the rocks and soil, were violently released to the atmosphere. The largest dose to an individual from these nuclides is small, but the population dose to those affected by the radioactivity in the ash is about 100 person rem. This population dose from Mount St. Helens is much greater than the annual person rem routinely released by a typical large nuclear power plant. It is estimated that subsequent eruptions of Mount St. Helens have doubled or tripled the person rem calculated from the initial large eruption. The long range global ash deposition of the May 18 eruption is estimated through 1984, by use of a global deposition model. The maximum deposition is nearly 1000 kg square km and occurs in the spring of 1981 over middle latitudes of the Northern Hemisphere.

Peterson, K. R.↗

p-MOSFET total dose dosimeter

A p-MOSFET total dose dosimeter where the gate voltage is proportional to the incident radiation dose. It is configured in an n-WELL of a p-BODY substrate. It is operated in the saturation region which is ensured by connecting the gate to the drain. The n-well is connected to zero bias. Current flow from source to drain, rather than from peripheral leakage, is ensured by configuring the device as an edgeless MOSFET where the source completely surrounds the drain. The drain junction is the only junction not connected to zero bias. The MOSFET is connected as part of the feedback loop of an operational amplifier. The operational amplifier holds the drain current fixed at a level which minimizes temperature dependence and also fixes the drain voltage. The sensitivity to radiation is made maximum by operating the MOSFET in the OFF state during radiation soak.

Buehler, Martin G.↗

Retrospectives: Intersection of Spaceflight Stressors and Microbial Risk to Crew and Craft

OVERVIEW The spaceflight environment has several unique stressors that affect the health of both the crew and the spacecraft. An area of continued, albeit incomplete, study is the interaction of these stressors on microbial populations inherent to both astronauts and spacecraft surfaces and systems. A primary concern is the potential for the spaceflight environment to perturb the phenotype of these populations towards negative outcomes for crew and craft. In order to effectively mitigate these potential risks, they must first be characterized. We performed a retrospective literature analysis to assess the current state of knowledge regarding the affects of ionizing radiation and elevated CO2 on relevant microbial populations. The results of these retrospectives will guide next steps in the decisions of what (if any) further studies should be pursued and to guide decisions of the need for countermeasures. STRESSORS Ionizing radiation. The health risk involved with increased exposure to cosmic radiation has been studied in crew for 35+ years, with human health and cancer risk being the main focus. However, space radiation could also affect both the resident microorganisms aboard the ISS and the normal, healthy astronaut microbiomes that are of direct concern for crew health. A retrospective review of over 250 publications was accomplished looking at the impact of cumulative ionizing radiation doses lower than 3 Gy (chronic or acute) on microbial populations. Elevated CO2. The health risk involved with elevated atmospheric CO2 in spacecraft, primarily focusing on human toxicological risks, is understudied. The current Spaceflight Maximum Allowance Concentration for 24-hour average CO2 is 0.4% (3 mm Hg), which is significantly higher than terrestrial levels (0.04%). Whether these elevated ambient CO2 levels aboard spacecraft influence the diversity and phenotypic responses of the resident microbial communities from both the spacecraft environment (air, surface, water) and crew members (gut, nasal,skin microbiomes) is not known. A retrospective review was accomplished looking at the impact of chronic CO2 exposure up to 0.7% (5 mm Hg) for up to 6 months and acute exposure up to 2.6% (20 mm Hg) for up to 24 hours. CONCLUSIONS: MICROBIOME OF THE BUILT ENVIRONMENT The microbiome of the built spacecraft environment has been sampled consistently over the course of human spaceflight and significant advancements have been made in identifying microbial populations on the ISS. The dominant source of microbes on spacecraft surfaces are human-derived. Once in the spacecraft built environment,the extreme environment selects for features that enhance survival. While efforts to understand potential antibiotic resistance and pathogenicity of ISS isolates is robust, there is little to no understanding of which spaceflight environmental stressors, to include ionizing radiation or elevated CO2, drive the evolutionary trajectory of spacecraft-associated microbial populations. CONCLUSIONS: MICROBE-HOST INTERACTIONS The host-microbiome field has emerged as an important factor in human health on Earth as well in spaceflight. The field is struggling with the complexity of the system under investigation as there is substantial taxonomic and functional heterogeneity in these communities, making it difficult to establish clear stimulus-response dynamics.Taxonomic characterization is the norm; however, the functional role of each community member is key to linking environmental perturbations to potential dysbiosis. For both ionizing radiation and elevated CO2, the likely target of the perturbation is the host tissue, not the microbes themselves.. Any resulting changes to the microbial community composition and/or function is likely a result of adapting to those changes in the host physiology. RECOMMENDATIONS Emphasize functional characterization as opposed to taxonomic characterization of microbial communities.Increase the number of investigations using chronic, spaceflight-relevant doses of ionizing radiation. MoBE studies should move away from observational studies towards predictive modeling of community dynamics. Continue to develop scale-down models, such as tissues-on-a-chip & defined microbial communities. Focus on the crew response to elevated CO2 over MoBE considerations. Assess how direct contact with the hypercapnic environment affects skin microbiome dynamics.

Countermeasures↗

Retrospectives: Current State of Knowledge on the Intersection of Spaceflight Stressors and Microbial Risks to Crew and Craft

OVERVIEW The spaceflight environment has several unique stressors that affect the health of both the crew and the spacecraft. An area of continued, albeit incomplete, study is the interaction of these stressors on microbial populations inherent to both astronauts and spacecraft surfaces and systems. A primary concern is the potential for the spaceflight environment to perturb the phenotype of these populations towards negative outcomes for crew and craft. In order to effectively mitigate these potential risks, they must first be characterized. We performed a retrospective literature analysis to assess the current state of knowledge regarding the affects of ionizing radiation and elevated CO2 on relevant microbial populations. The results of these retrospectives will guide next steps in the decisions of what (if any) further studies should be pursued and to guide decisions of the need for countermeasures. STRESSORS Ionizing radiation. The health risk involved with increased exposure to cosmic radiation has been studied in crew for 35+ years, with human health and cancer risk being the main focus. However, space radiation could also affect both the resident microorganisms aboard the ISS and the normal, healthy astronaut microbiomes that are of direct concern for crew health. A retrospective review of over 250 publications was accomplished looking at the impact of cumulative ionizing radiation doses lower than 3 Gy (chronic or acute) on microbial populations. Elevated CO2. The health risk involved with elevated atmospheric CO2 in spacecraft, primarily focusing on human toxicological risks, is understudied. The current Spaceflight Maximum Allowance Concentration for 24-hour average CO2 is 0.4% (3 mm Hg), which is significantly higher than terrestrial levels (0.04%). Whether these elevated ambient CO2 levels aboard spacecraft influence the diversity and phenotypic responses of the resident microbial communities from both the spacecraft environment (air, surface, water) and crew members (gut, nasal, skin microbiomes) is not known. A retrospective review was accomplished looking at the impact of chronic CO2 exposure up to 0.7% (5 mm Hg) for up to 6 months and acute exposure up to 2.6% (20 mm Hg) for up to 24 hours. CONCLUSIONS: MICROBIOME OF THE BUILT ENVIRONMENT The microbiome of the built spacecraft environment has been sampled consistently over the course of human spaceflight and significant advancements have been made in identifying microbial populations on the ISS. The dominant source of microbes on spacecraft surfaces are human-derived. Once in the spacecraft built environment, the extreme environment selects for features that enhance survival. While efforts to understand potential antibiotic resistance and pathogenicity of ISS isolates is robust, there is little to no understanding of which spaceflight environmental stressors, to include ionizing radiation or elevated CO2, drive the evolutionary trajectory of spacecraft-associated microbial populations. CONCLUSIONS: MICROBE-HOST INTERACTIONS The host-microbiome field has emerged as an important factor in human health on Earth as well in spaceflight. The field is struggling with the complexity of the system under investigation as there is substantial taxonomic and functional heterogeneity in these communities, making it difficult to establish clear stimulus-response dynamics. Taxonomic characterization is the norm; however, the functional role of each community member is key to linking environmental perturbations to potential dysbiosis. For both ionizing radiation and elevated CO2, the likely target of the perturbation is the host tissue, not the microbes themselves.. Any resulting changes to the microbial community composition and/or function is likely a result of adapting to those changes in the host physiology. RECOMMENDATIONS Emphasize functional characterization as opposed to taxonomic characterization of microbial communities. Increase the number of investigations using chronic, spaceflight-relevant doses of ionizing radiation. MoBE studies should move away from observational studies towards predictive modeling of community dynamics. Continue to develop scale-down models, such as tissues-on-a-chip & defined microbial communities. Focus on the crew response to elevated CO2 over MoBE considerations. Assess how direct contact with the hypercapnic environment affects skin microbiome dynamics.

retrospective↗

Ligand assisted growth of perovskite single crystals with low defect density

A low defect density in metal halide perovskite single crystals is critical to achieve high performance optoelectronic devices. Here we show the reduction of defect density in perovskite single crystals grown by a ligand-assisted solution process with 3-(decyldimethylammonio)-propane-sulfonate inner salt (DPSI) as an additive. DPSI ligands anchoring with lead ions on perovskite crystal surfaces not only suppress nucleation in solution, but also regulate the addition of proper ions to the growing surface, which greatly enhances the crystal quality. The grown CH 3 NH 3 PbI 3 crystals show better crystallinity and a 23-fold smaller trap density of 7 × 10 10 cm -3 than the optimized control crystals. The enhanced material properties result in significantly suppressed ion migration and superior X-ray detection sensitivity of CH 3 NH 3 PbI 3 detectors of (2.6 ± 0.4) × 10 6 µC Gy -1 air cm -2 for 60 kVp X-ray and the lowest detectable dose rate reaches (5.0 ± 0.7) nGy s -1 , which enables reduced radiation dose to patients in medical X-ray diagnostics.

36 MATERIALS SCIENCE↗

Heavy-ion induced genetic changes and evolution processes

On Moon and Mars, there will be more galactic cosmic rays and higher radiation doses than on Earth. Our experimental studies showed that heavy ion radiation can effectively cause mutation and chromosome aberrations and that high Linear Energy Transfer (LET) heavy-ion induced mutants can be irreversible. Chromosome translocations and deletions are common in cells irradiated by heavy particles, and ionizing radiations are effective in causing hyperploidy. The importance of the genetic changes in the evolution of life is an interesting question. Through evolution, there is an increase of DNA content in cells from lower forms of life to higher organisms. The DNA content, however, reached a plateau in vertebrates. By increasing DNA content, there can be an increase of information in the cell. For a given DNA content, the quality of information can be changed by rearranging the DNA. Because radiation can cause hyperploidy, an increase of DNA content in cells, and can induce DNA rearrangement, it is likely that the evolution of life on Mars will be effected by its radiation environment. A simple analysis shows that the radiation level on Mars may cause a mutation frequency comparable to that of the spontaneous mutation rate on Earth. To the extent that mutation plays a role in adaptation, radiation alone on Mars may thus provide sufficient mutation for the evolution of life.

Yang, C. H.↗

Proton Lateral Broadening Distribution Comparisons Between GRNTRN, MCNPX, and Laboratory Beam Measurements

Recent developments in NASA s deterministic High charge (Z) and Energy TRaNsport (HZETRN) code have included lateral broadening of primary ion beams due to small-angle multiple Coulomb scattering, and coupling of the ion-nuclear scattering interactions with energy loss and straggling. This new version of HZETRN is based on Green function methods, called GRNTRN, and is suitable for modeling transport with both space environment and laboratory boundary conditions. Multiple scattering processes are a necessary extension to GRNTRN in order to accurately model ion beam experiments, to simulate the physical and biological-effective radiation dose, and to develop new methods and strategies for light ion radiation therapy. In this paper we compare GRNTRN simulations of proton lateral broadening distributions with beam measurements taken at Loma Linda University Proton Therapy Facility. The simulated and measured lateral broadening distributions are compared for a 250 MeV proton beam on aluminum, polyethylene, polystyrene, bone substitute, iron, and lead target materials. The GRNTRN results are also compared to simulations from the Monte Carlo MCNPX code for the same projectile-target combinations described above.

Mertens, Christopher J.↗

Impact of the May 2024 Gannon Storm on Low Earth Orbit Dosimetric Quantities: Comparisons of the NAIRAS Model -Real Time and Re-analysis- with ISS Data

The solar storm of May 2024, the Gannon storm, led to a display of aurora over the globe. One of the less known effects of that storm is on the radiation doses in low-Earth orbit: it first led to a Forbush decrease in dose rates and then to a Solar Energetic Particle (SEP) event that increased the total dose suffered near the international space station. The Nowcast of Aerospace Ionizing RAdiation System (NAIRAS) model predicts dosimetric and radiative flux quantities for assessing human radiation exposure levels and radiation effects on flight electronic systems from the surface of the Earth to deep space. It runs in near-real-time at the CCMC, but also has a run-on-request that allows for a more precise computation thanks to carefully processed data. NAIRAS was able to compute the effects of the Gannon storm at the ISS in real-time and provide ideas of the doses encountered by the astronauts and the experiments in and outside of the station. In this work, we show the simulations of the doses encountered during the storm and compare them with several measurements at the ISS. This work shows the capabilities of NAIRAS to address the problem of the SEP events at low Earth orbit and its real-time capabilities.

Guillaume Gronoff↗

Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

Enhanced Low Dose Rate Sensitivity (ELDRS)↗

A 100-Mrad (Si) JFET-based Sensing and Communications System for Extreme Nuclear Instrumentation Environments

Dry cask storage is one of two storage methods approved by the U.S. Nuclear Regulatory Commission for spent fuel after removal from reactor cores. Dry casks consist of a stainless steel canister enclosed in a concrete overpack to contain the hazardous radioactive spent fuel rods and provide radiation shielding. Monitoring spent fuel storage casks is desired to ensure the safe containment of the enclosed spent fuel, but is very difficult due to the related harsh temperature and radiation environment. The sensors and associated electronics to monitor temperature, pressure, and/or radiation need to survive high temperatures and radiation doses for extended time periods. For this reason, there is a severe need for radiation-hardened electrical systems that survive well beyond the existing capabilities of commercially available radiation-rated electronic components, which have primarily been developed for space applications. Junction-gate field-effect transistor (JFET) devices are inherently radiation hardened [exceeding 100 Mrad (Si)]. Additionally, when JFETs are used as building blocks for sensing and communication electronics (i.e., oscillators, amplifiers, filters, and mixers), inherently radiation-hardened circuits can be achieved. To this end, JFET-based radiation-hardened electronics interfacing with cask-embedded sensors capable of driving modulated sensor signals through a stainless steel barrier were designed and tested at a dose rate of approximately 500 krad/h (Si) to beyond a 200-Mrad (Si) total ionizing dose. After 200 Mrad (Si), the sensor and communication circuit signals were correctly decoded at the receiver despite oscillator drift. The results from this experiment demonstrate the potential for creating more complex radiation-hardened JFET-based electrical systems for nuclear environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TPSAS-NF1676L-32652-DND

Space weather is an important driver of the exposure of aircrew and passengers to cosmic rays at flight altitudes. The assessment of the corresponding radiation doses can be realized by measurements or model calculations that cover the whole range of the radiation field in terms of geomagnetic shielding, atmospheric shielding, and the effects of space weather. Since the radiation field at aviation altitudes is very complex in terms of particle composition and energy distribution, the accurate experimental determination of doses at aviation altitudes is still a challenging task. Accordingly, the amount of data with comparatively small uncertainties is scarce. The Community Coordinated Modeling Center invited the Federal Aviation Administration, the German Aerospace Center, and the National Aeronautics and Space Administration to make their radiation models for aviation CARI-7A, PANDOCA, and NAIRAS available for interested users via the Community Coordinated Modeling Center web site. A concomitant comparison of model calculations with measuring data provided information on the predicting capabilities and the uncertainties of the current versions of these models under quiet space weather conditions.

Matthias M Meier↗

Effects of Radiation on Rat Retina after 18 days of Space Flight

Although cumulative effects an retina from low-dose radiation during prolonged spaceflight are not known, ary impairment of vision could set limits for spaceflight duration. Cosmic rays are now considered to be the cause of the "light flashes" seen during spaceflight by activating retina cells as they pass through the photoreceptors. Previous studies have also shown retinal cellular alterations and cell necrosis from high-energy, particle (HZE) radiation. Ten rats, 5 centrifuged during flight (FC) to simulate gravity and 5 in-flight stationary (FS) experiencing hypogravity, orbited Earth for 18.5 days on Cosmos 936. The animals were sacrificed 25 days post-recovery and the eyes flown to Ames Res. Ctr. The pattern of cell necrosis in the retinas from the FC group showed the same response to radiation as the FS. This would indicate that hypogravity was not a factor in the observed results. Also the cellular response in the retinas exposed in the Berkeley accelerator again matched both the FC and FS eyes. Thus all three conditions provide comparable changes and indicate HZE particles as the possible cause of the cellular alterations, channels, and breakdown.

Philpott, D.↗

An analysis of interplanetary space radiation exposure for various solar cycles

The radiation dose received by crew members in interplanetary space is influenced by the stage of the solar cycle. Using the recently developed models of the galactic cosmic radiation (GCR) environment and the energy-dependent radiation transport code, we have calculated the dose at 0 and 5 cm water depth; using a computerized anatomical man (CAM) model, we have calculated the skin, eye and blood-forming organ (BFO) doses as a function of aluminum shielding for various solar minima and maxima between 1954 and 1989. These results show that the equivalent dose is within about 15% of the mean for the various solar minima (maxima). The maximum variation between solar minimum and maximum equivalent dose is about a factor of three. We have extended these calculations for the 1976-1977 solar minimum to five practical shielding geometries: Apollo Command Module, the least and most heavily shielded locations in the U.S. space shuttle mid-deck, center of the proposed Space Station Freedom cluster and sleeping compartment of the Skylab. These calculations, using the quality factor of ICRP 60, show that the average CAM BFO equivalent dose is 0.46 Sv/year. Based on an approach that takes fragmentation into account, we estimate a calculation uncertainty of 15% if the uncertainty in the quality factor is neglected.

NASA Discipline Radiation Health↗