Search NASA⌕ Search

SEARCH · Search NASA

Results for “Relative Permeability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Toward a Realistic Representation of Sucrose Transport in the Phloem of Plants

The significance of phloem hydrodynamics to plant mortality and survival, which impacts ecosystem-scale carbon and water cycling, is not in dispute. The phloem provides the conduits for products of photosynthesis to be transported to different parts of the plant for consumption or storage. The M$\ddot{u}$nch pressure flow hypothesis (PFH) is the leading framework to mathematically represent this transport. It assumes that osmosis provides the necessary pressure differences to drive water and sucrose within the phloem. Mathematical models utilizing the PFH approximate the phloem by a relatively rigid slender semi-permeable tube. However, the phloem consists of living cells that contract and expand in response to pressure fluctuations. The effect of membrane elasticity on osmotically driven sucrose front speed has rarely been considered and frames the scope here. Laboratory experiments were conducted to elucidate the elastic-to-plastic pressure-deformation relation in membranes and their effect on sucrose front speeds. It is demonstrated that membrane elasticity acts to retard the sucrose front speed. The retardation emerges because of two effects: (a) part of the osmotic pressure is diverted to perform mechanical work to expand the membrane instead of pressurizing water, and (b) expansion of the membrane reduces the sucrose concentration driving osmotic potential due to volume increases and concomitant dilution effects. Finally, these results offer a novel perspective about the much discussed presence of sieve plates throughout the phloem acting as structural expansion dampers.

59 BASIC BIOLOGICAL SCIENCES↗

Advances in Computational Approaches for Estimating Passive Permeability in Drug Discovery

Passive permeation of cellular membranes is a key feature of many therapeutics. The relevance of passive permeability spans all biological systems as they all employ biomembranes for compartmentalization. A variety of computational techniques are currently utilized and under active development to facilitate the characterization of passive permeability. These methods include lipophilicity relations, molecular dynamics simulations, and machine learning, which vary in accuracy, complexity, and computational cost. This review briefly introduces the underlying theories, such as the prominent inhomogeneous solubility diffusion model, and covers a number of recent applications. Various machine-learning applications, which have demonstrated good potential for high-volume, data-driven permeability predictions, are also discussed. Due to the confluence of novel computational methods and next-generation exascale computers, we anticipate an exciting future for computationally driven permeability predictions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Porous media properties of reticulated shape memory polymer foams and mock embolic coils for aneurysm treatment

Background: Shape memory polymer (SMP) foams are being investigated as an alternative aneurysm treatment method to embolic coils. The goal of both techniques is the reduction of blood flow into the aneurysm and the subsequent formation of a stable thrombus, which prevents future aneurysm rupture. The purpose of this study is to experimentally determine the parameters, permeability and form factor, which are related to the flow resistance imposed by both media when subjected to a pressure gradient. Methods: The porous media properties—permeability and form factor—of SMP foams and mock embolic coils (MECs) were measured with a pressure gradient method by means of an in vitro closed flow loop. We implemented the Forchheimer-Hazen-Dupuit-Darcy equation to calculate these properties. Mechanically-reticulated SMP foams were fabricated with average cell sizes of 0.7E-3 and 1.1E-3 m, while the MECs were arranged with volumetric packing densities of 11-28%. Results: The permeability of the SMP foams was an order of magnitude lower than that of the MECs. The form factor differed by up to two orders of magnitude and was higher for the SMP foams in all cases. The maximum flow rate of all samples tested was within the inertial laminar flow regime, with Reynolds numbers ranging between 1 and 35. Conclusions: The SMP foams impose a greater resistance to fluid flow compared to MECs, which is a result of increased viscous and inertial losses. These results suggest that aneurysms treated with SMP foam will have flow conditions more favorable for blood stasis than those treated with embolic coils having packing densities ≤ 28%.

36 MATERIALS SCIENCE↗

Oil in Alaska North Slope Gas Hydrate Reservoir: Micro-CT and Flow Simulation Insights into Permeability

Gas hydrate-bearing sands on the Alaska North Slope (ANS) host minor volumes of crude oil whose impact on formation permeability has never been quantified relative to a gas hydrate reservoir system. Here, we combine in situ pressure-core microcomputed-tomography (μ-CT), thermogravimetric analysis (TGA), gas-chromatography–mass-spectrometry (GC–MS), scanning-electron microscopy coupled with energy-dispersive spectroscopy (SEM-EDS), and Stokes-flow simulation to (i) quantify oil saturation, (ii) infer its source, and (iii) evaluate its influence on permeability after gas-hydrate dissociation. μ-CT and SEM-EDS imaging identify the host sediment as silty, with some grain-coating clay present. Eight representative 3003-voxel subvolumes extracted from a preserved pressure core (Core 15P-3c, from the B1 sand (unit B), HYDRATE 02 Geo Data Well (GDW), 886.96–887.29 m measured depth, MD) exhibit porosities of 0.34–0.37 and an average oil saturation of 0.09 ± 0.03, in comparison to an independent TGA-based estimate of 0.16. GC-MS fingerprints obtained from an adjacent depressurized core (Core 17P-1, 891.37–891.44 m MD), together with oil pore habit revealed by μ-CT, suggest that the oil is partly native but also includes contributions from mineral oil-based drilling fluid contamination. Further analysis of oil–porewater interactions and flushing tests confirms that native oil saturation in the analyzed samples ranges from 0.04 to 0.08 with an average of approximately 0.06, and the oil is highly immobile. Flow simulations demonstrate that the native oil saturation of ≈0.06 reduces permeability by approximately 50% due to both pore blockage and increased flow-path tortuosity. These findings reveal the potential presence of native oil within the ANS gas hydrate reservoir and suggest that future simulation models may need to account for its impact on permeability to improve long-term performance predictions of gas and water production.

02 PETROLEUM↗

Calcium Sulfate and Calcium Carbonate Scaling of Thin-Film Composite Polyamide Reverse Osmosis Membranes with Surface-Tethered Polyacrylic Acid Chains

The gypsum and calcite scaling propensities of the thin-film composite polyamide (PA-TFC) reverse osmosis (RO) membrane, modified with a tethered surface layer of polyacrylic acid (PAA) chains, was evaluated and compared to the scaling of selected commercial RO membranes. The tethered PAA layer was synthesized onto a commercial polyamide membrane (i.e., base-PA) via atmospheric pressure plasma-induced graft polymerization (APPIGP). The PAA nano-structured (SNS) base-PA membrane (SNS-PAA-PA) was scaled to a lesser degree, as quantified by a lower permeate flux decline and surface imaging, relative to the tested commercial membranes (Dow SW30, Toray SWRO, and BWRO). The cleaning of gypsum-scaled membranes with D.I. water flushing achieved 100% water permeability recovery for both the SNS-PAA-PA and Dow SW30 membranes, relative to 92–98% permeability restoration for the Toray membranes. The calcium carbonate scaling of SNS-PAA-PA membranes was also lower relative to the commercial membranes, but permeability recovery after D.I. water cleaning was somewhat lower (94%) but consistent with the level of surface scale coverage. In contrast, the calcite and gypsum-scaled membrane areas of the commercial membranes post-cleaning were significantly higher than for the SNS-PAA-PA membrane but with 100% permeability recovery, suggesting the potential for membrane damage when mineral scaling is severe.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Universal scaling-law for flow resistance over canopies with complex morphology

Flow resistance caused by vegetation is a key parameter to properly assess flood management and river restoration. However, quantifying the friction factor or any of its alternative metrics, e.g. the drag coefficient, in canopies with complex geometry has proven elusive. We explore the effect of canopy morphology on vegetated channels flow structure and resistance by treating the canopy as a porous medium characterized by an effective permeability, a property that describes the ease with which water can flow through the canopy layer. We employ a two-domain model for flow over and within the canopy, which couples the log-law in the free layer to the Darcy-Brinkman equation in the vegetated layer. We validate the model analytical solutions for the average velocity profile within and above the canopy, the volumetric discharge and the friction factor against data collected across a wide range of canopy morphologies encountered in riverine systems. Results indicate agreement between model predictions and data for both simple and complex plant morphologies. For low submergence canopies, we find a universal scaling law that relates friction factor with canopy permeability and a rescaled bulk Reynolds number. This provides a valuable tool to assess habitats sustainability associated with hydro-dynamical conditions.

54 ENVIRONMENTAL SCIENCES↗

The effect of precursor types on the magnetic properties of Y-type hexa-ferrite composite

With magnetic composite including uniform magnetic particles, we expect to realize good high-frequency soft magnetic properties. We produced needle-like (α-FeOOH) nanoparticles with nearly uniform diameter and length of 20 and 500 nm. Zn-doped Y-type hexa-ferrite samples were prepared by solid state reaction method using the uniform goethite and non-uniform hematite (Fe{sub 2}O{sub 3}) with size of <1 μm, respectively. The micrographs observed by scanning electron microscopy show that more uniform hexagonal plates are observed in ZYG-sample (Zn-doped Y-type hexa-ferrite prepared with non-uniform hematite) than in ZYH-sample (Zn-doped Y-type hexa-ferrite prepared with uniform goethite). The permeability (μ′) and loss tangent (δ) at 2 GHz are 2.31 and 0.07 in ZYG-sample and 2.0 and 0.07 in ZYH sample, respectively. We can observe that permeability and loss tangent are strongly related to the particle size and uniformity based on the nucleation, growth, and two magnetizing mechanisms: spin rotation and domain wall motion. The complex permeability spectra also can be numerically separated into spin rotational and domain wall resonance components.

36 MATERIALS SCIENCE↗

Percolation connectivity, pore size, and gas apparent permeability: Network simulations and comparison to experimental data: Connectivity, Pore Size, and Gas Permeability

We modeled single-phase gas flow through porous media using percolation networks. Gas permeability is different from liquid permeability. The latter is only related to the geometry and topology of the pore space, while the former depends on the specific gas considered and varies with gas pressure. As gas pressure decreases, four flow regimes can be distinguished as viscous flow, slip flow, transition flow, and free molecular diffusion. Here we use a published conductance model presumably capable of predicting the flow rate of an arbitrary gas through a cylindrical pipe in the four regimes. We incorporated this model into pipe network simulations. We considered 3-D simple cubic, body-centered cubic, and face-centered cubic lattices, in which we varied the pipe radius distribution and the bond coordination number. Gas flow was simulated at different gas pressures. The simulation results showed that the gas apparent permeability k app obeys an identical scaling law in all three lattices, k app ~ (z-z c ) β , where the exponent β depends on the width of the pipe radius distribution, z is the mean coordination number, and z c its critical value at the percolation threshold. Surprisingly, (z-z c ) had a very weak effect on the ratio of the apparent gas permeability to the absolute liquid permeability, k app /k abs , suggesting that the Klinkenberg gas slippage correction factor is nearly independent of connectivity. We constructed models of k app and k app /k abs based on the observed power law and tested them by comparison with published experimental data on glass beads and other materials.

58 GEOSCIENCES↗

3D Printing of Functional Hydrogel Devices for Screenings of Membrane Permeability and Selectivity

Developing a fundamental understanding of the effects of varying ligand chemistries on mass transport rates is key to designing membranes with solute-specific selectivity. While permeation cells offer a robust method to characterize membrane performance, they are limited to assessing a single membrane chemistry or salt solution per test. As a result, investigating the effects of varying ligand chemistries on membrane performance can be a tedious process, involving both the preparation of multiple samples and numerous, time-consuming permeation tests. This study uses digital light processing (DLP) 3D printing to fabricate a millifluidic flow-based permeation device made from a hydrogel active ester network that can be easily functionalized with ion-selective ligands. Without the need for bonding or assembly steps, ligands can be introduced and tested in the permeation device by simply injecting a small volume of a ligand solution. Various salt concentrations and molecular species can be cycled through a single device by switching the solution feeding into the salt reservoir, thereby reducing the number of samples needed for permeability and selectivity screenings. This research sets the groundwork for formulation development and postprocessing methods to 3D-print functional millifluidic devices capable of assessing solute selectivity in membranes and polymer adsorbents for aqueous separations. In this work, comparable salt permeability trends were observed with both 3D-printed devices and traditional assays. Devices were functionalized with an imidazole ligand to investigate salt permeability and selectivity of monovalent and divalent salts. Measurements showed increasing permeability for monovalent salts (NaCl) relative to divalent salts (MgCl 2 , CuCl 2 ) in functionalized membranes, with higher monovalent/divalent selectivity at increasing imidazole grafting densities. Here, the methods and findings described here represent a step toward developing higher-throughput methods with 3D-printed devices for screening the effects of ligand chemistry on mass transport rates in membrane materials.

36 MATERIALS SCIENCE↗

Non-permeable substrate carrier for electroplating

One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The substrate carrier comprises a non-conductive carrier body on which the substrates are to be held. Electrically-conductive lines are embedded within the carrier body, and a plurality of contact clips are coupled to the electrically-conductive lines embedded within the carrier body. The contact clips hold the substrates in place and electrically couple the substrates to the electrically-conductive lines. The non-conductive carrier body is continuous so as to be impermeable to flow of electroplating solution through the non-conductive carrier body. Other embodiments, aspects and features are also disclosed.

36 MATERIALS SCIENCE↗

Non-permeable substrate carrier for electroplating

One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The substrate carrier comprises a non-conductive carrier body on which the substrates are to be held. Electrically-conductive lines are embedded within the carrier body, and a plurality of contact clips are coupled to the electrically-conductive lines embedded within the carrier body. The contact clips hold the substrates in place and electrically couple the substrates to the electrically-conductive lines. The non-conductive carrier body is continuous so as to be impermeable to flow of electroplating solution through the non-conductive carrier body. Other embodiments, aspects and features are also disclosed.

36 MATERIALS SCIENCE↗

Non-permeable substrate carrier for electroplating

One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The substrate carrier comprises a non-conductive carrier body on which the substrates are to be held. Electrically-conductive lines are embedded within the carrier body, and a plurality of contact clips are coupled to the electrically-conductive lines embedded within the carrier body. The contact clips hold the substrates in place and electrically couple the substrates to the electrically-conductive lines. The non-conductive carrier body is continuous so as to be impermeable to flow of electroplating solution through the non-conductive carrier body. Other embodiments, aspects and features are also disclosed.

42 ENGINEERING↗

Antivascular Effects of Neoadjuvant Androgen Deprivation for Prostate Cancer: An In Vivo Human Study Using Susceptibility and Relaxivity Dynamic MRI

Purpose: The antivascular effects of androgen deprivation have been investigated in animal models; however, there has been minimal investigation in human prostate cancer. This study tested the hypothesis that androgen deprivation causes significant reductions in human prostate tumor blood flow and the induction of hypoxia at a magnitude and in a time scale relevant to the neoadjuvant setting before radiotherapy. Methods and Materials: Twenty patients were examined, each with five multi-parameter magnetic resonance imaging scans: two scans before the commencement of androgen suppression, one scan after 1 month of hormone treatment, and two further scans after 3 months of therapy. Quantitative parametric maps of the prostate informing on relative blood flow (rBF), relative blood volume (rBV), vascular permeability (transfer constant [K{sup trans}]), leakage space (v{sub e}) and blood oxygenation (intrinsic relaxivity [R{sub 2}*]) were calculated. Results: Tumor blood volume and blood flow decreased by 83% and 79%, respectively, in the first month (p < 0.0001), with 74% of patients showing significant changes. The proportion of individual patients who achieved significant changes in T1 kinetic parameter values after 3 months of androgen deprivation for tumor measurements was 68% for K{sup trans} and 53% for v{sub e} By 3 months, significant increases in R{sub 2}* had occurred in prostate tumor, with a rise of 41.1% (p < 0.0001). Conclusions: Androgen deprivation induces profound vascular collapse within 1 month of starting treatment. Increased R{sub 2}* in regions of prostate cancer and a decrease in blood volume suggest a reduction in tumor oxygenation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maximizing selectivity: An analysis of isoporous membranes

Membranes are compelling candidates for many separation-based industrial processes. However, all synthetic membranes are subject to well-recognized permeability-selectivity trade-offs that hinder their use in advanced applications. Having uniform nanoscale pore size, isoporous nanofiltration and ultrafiltration membranes have attracted wide research interest. However, quantitative analysis of isoporous membrane performance is lacking - particularly at module and system-level scales. In this study, an analytical model is built to investigate how membrane pore-size distribution affects the solute separation efficiency (i.e., rejection and selectivity). The model accounts for convective hindrance as well as concentration polarization and explores effects on separation from the solute-to-pore-size ratio and percent recovery (i.e., fraction of feed flow that passes through the membrane). At the module level, our analysis suggests that a notably sharper rejection vs. solute size curve can be obtained as the pore-size distribution becomes narrower. Additionally, as the recovery increases, the rejection of a solute is maintained at a high level using isoporous membranes while the rejection drops rapidly for membranes that possess a disperse pore-size distribution. Furthermore, in the separation of mixed solutes, isoporous membranes achieve a large selectivity with a modest loss of permeability. Overall, this study elaborates the unique role that isoporous membranes play within the permeability-selectivity trade-off relations and identifies the most exciting opportunities for their future applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ensemble Shear Strength, Stability, and Permeability of Mixed Mineralogy Fault Gouge Recovered From 3D Granular Models

We conduct numerical shear experiments on mixtures of quartz and talc gouge using a three-dimensional (3D) distinct element model. A modified slip-weakening constitutive law is applied at contacts. We perform velocity-stepping experiments on both uniform and layered mixtures of quartz and talc analogs. We separately vary the proportion of talc in the uniform mixtures and talc layer thickness in the layered mixtures. Shear displacements are cycled through velocities of 1 and 10 μm/s. We follow the resulting evolution of ensemble shear strength, slip stability, and permeability of the gouge mixture and explore the mesoscopic mechanisms. Simulation results show that talc has a strong weakening effect on shear strength—a thin shear-parallel layer of talc (three particles wide) can induce significant weakening. However, the model offsets laboratory-derived strong weakening effects of talc observed in uniform mixtures, implying the governing mechanisms may be the shear localization effect of talc, which is enhanced by its natural platy shape or preimposed layered structure. Ensemble stability (a – b ) can be enhanced by increasing talc content in uniform talc-quartz mixtures. Reactivation-induced permeability increase is amplified with increased quartz content before the maturation of shear localization. Postmaturation permeability enhances on velocity upsteps and diminishes on velocity downsteps. Talc enhances compaction at velocity downsteps, potentially reducing fault permeability. Evolution trends of stability relating to the composition and structure of the fault gouge are straightforwardly obtained from the 3D simulation. Local friction evolution indicates that talc preferentially organizes and localizes in the shear zone, dominating the shear strength and frictional stability of faults

58 GEOSCIENCES↗

Effect of temperature and time on properties of spark plasma sintered NiCuZn: Co ferrite

Spark plasma sintering is a powerful method to produce fine grain dense ferrite at low temperature. However the process, usually conducted in neutral atmosphere in a carbon die, yields carbon surface deposition and the reduction of Fe{sup 3+} into Fe{sup 2+}. It is shown that subsequent annealing in air can remove carbon and under some conditions produce complete oxidation of Fe{sup 2+} ions. Regular values of the resistivity and permittivity (resp., 1 M{Omega}m, 13 {epsilon}{sub 0}) are recovered for most samples annealed at temperatures not higher than 750 deg. C. A relatively high value of the permeability (up to 240) and a high merit factor ({mu}{sub s}xf{sub r}>5 GHz) have been achieved.

36 MATERIALS SCIENCE↗