Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION COUNTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A collimated neutron detector for RFP plasmas in MST

The neutron emissivity profile in the Madison Symmetric Torus is being reconstructed through the use of a collimated neutron detector. A scintillator-photomultiplier tube (PMT) system is employed to detect the fusion neutrons with the plasma viewing volume defined by a 55 cm deep, 5 cm diameter aperture. Effective detection of neutrons from the viewing volume is achieved through neutron moderation using 1300 lbs of high density polyethylene shielding, which modeling predicts attenuates the penetrating flux by a factor of 10{sup 4} or more. A broad spectrum of gamma radiation is also present due to the unconfined fusion proton bombardment of the thick aluminum vacuum vessel. A 15 cm cylindrical liquid scintillator of 3.8 cm diameter is used to further increase directional sensitivity. A fast (5 ns rise time) preamplifier and digitization at 500 MHz prevent pulse pile-up even at high count rates (∼10{sup 4}/s). The entire neutron camera system is situated on an adjustable inclining base which provides the differing plasma viewing volumes necessary for reconstruction of the neutron emissivity profile. This profile, directly related to the fast-ion population, allows for an investigation of the critical fast-ion pressure gradient required to destabilize a neutral beam driven Alfvénic mode which has been shown to transport fast ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GIOVE, a shallow laboratory Ge-spectrometer with 100 μBq/kg sensitivity

A new germanium gamma spectrometer called GIOVE (Germanium spectrometer with Inner and Outer Veto) has been set up at the underground/shallow laboratory (15 m w.e.) of MPI-K. Its double plastic scintillator veto system and neutron moderation interlayer lower the background by more than one order of magnitude compared to the other existing spectrometer at this facility. The integral (40-2700 keV) background rate of about 290 counts (day kg){sup −1} is just a factor 4 to 8 above that of the GeMPI spectrometers operated at LNGS (3800 m w.e.) and thus proves that even under shallow overburden sub mBq/kg sensitivities are achievable. Extended material screening and neutron attenuation studies preceded the final design of the spectrometer. The technical realization of the spectrometer is described in detail with special emphasis on the inner veto system. For its optimisation a simulation model was developed for light collection on small low activity PMT’s under various geometrical conditions. Radon suppression is accomplished by employing a gas tight sample container and a nitrogen flushed glove-box system with an airlock. The active volume of the crystal was modelled by absorption scanning measurements and Monte Carlo simulations. The complete shield is implemented in a Geant4 based simulation framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pile-up recovery in gamma-ray detection

Count rates in gamma-ray detectors are fundamentally limited at the high end by the physics of the detection process but should not be limited further by the design of read-out. Using intense stimuli, such as the ELI, it is desirable to extract the full wealth of information flow that sensors can deliver. We discuss the photon-statistical limitations of scintillation systems and charge-collection issues of solid-state detectors. With high-speed digitizing in particular, two promising approach architectures are those of posterior list mode corrections and of time-domain adaptive filters, introducing a 'rich list mode with uncertainties' and thus a somewhat different look at experimental spectra. Real-time performance is also considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A probable 1970 hard X-ray outburst by 4U0041+32

Balloon observations of a hard X-ray burst in 1970 most likely associated with the highly variable high-latitude X-ray source 4U 0041+32 are reported. The observation of X-ray flux at a density of about 0.06 photons/sq cm per sec from a previously unknown source at r.a. O h 45 min, dec 33 + or - 3 deg was made by a scintillation telescope on February 4, 1970. The spectrum was found to be very hard between 25 and 300 keV, with radiation in the form of a well-collimated beam causing the excess counting rate over a period of 30 min. Further observations on September 25, 1970 indicated the object had faded to an intensity below 0.01 photons/sq cm per sec. The power law spectrum obtained during the February burst is observed to differ from those of other hard transients and hard compact binary X-ray sources by the fact that it extends to 300 keV, its apparent lack of pulsation and its not being associated with an early-type giant or supergiant companion.

Laros, J. G.↗

Comparison of Supervised and Un-Supervised Machine Learning Algorithms for Threat Detection and Scintillator Performance for Radiation Portal Monitoring

Following the events of September 11, 2001, international border crossing have been equipped with radiation portal monitors (RPMs) to identify illicit radioactive material. Polyvinyl toluene (PVT) scintillators are commonly used due to their low cost and reasonable maintainability, however they offer low spectral resolution. Despite the fact that over twenty years has transpired since this event, radioisotopes are still typically identified by hand-crafted classification algorithms, e.g., total counts or energy windowing, and exhibit relatively poor performance in detecting threats at the low false alarm rates required to support the stream of commerce. While some improvement to performance has been realized via the use of supervised machine learning, these classification algorithms typically utilize simulations in lieu of real data due to the sparsity of data for one or more classes. Accordingly, the performance of these algorithms is somewhat less than optimal when examining experiments or simulations with model mismatch. Consequently, in this work, we examine the application of a number of unsupervised machine learning, anomaly detection based algorithms, to circumvent the inverse crime when analyzing spectroscopy data for RPMs. We also compare anomaly detection results with those obtained via the use of supervised classification detection ML algorithms when model mismatch is introduced between the simulated threat items utilized for training/testing. Finally, we compared the performance of the PVT scintillators to those obtained with higher resolution detectors using both anomaly detection and supervised classification algorithms.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Lifetime measurements of 214Po and 212Po with the CTF liquid scintillator detector at LNGS

We have studied the alpha decays of 214Po into 210Pb and of 212Po into 208Pb tagged by the coincidence with the preceding beta decays from 214Bi and 212Bi, respectively. The employed 222Rn, 232Th, and 220Rn sources were sealed inside quartz vials and inserted in the Counting Test Facility at the underground Gran Sasso National Laboratory in Italy. We find that the mean lifetime of 214Po is (236.00 +- 0.42(stat) +- 0.15(syst)) \mu s and that of 212Po is (425.1 +- 0.9(stat) +- 1.2(syst)) ns. Our results, obtained from data with signal-to-background ratio larger than 1000, reduce the overall uncertainties and are compatible with previous measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AMS Ground Truth Measurements: Calibration and Test Lines

Airborne gamma spectrometry is one of the primary techniques used to define the extent of ground contamination after a radiological incident. Its usefulness was demonstrated extensively during the response to the Fukushima nuclear power plant (NPP) accident in March-May 2011. To map ground contamination a set of scintillation detectors is mounted on an airborne platform (airplane or helicopter) and flown over contaminated areas. The acquisition system collects spectral information together with the aircraft position and altitude every second. To provide useful information to decision makers, the count rate data expressed in counts per second (cps) needs to be converted to the terrestrial component of the exposure rate 1 m above ground, or surface activity of isotopes of concern. This is done using conversion coefficients derived from calibration flights. During a large scale radiological event, multiple flights may be necessary and may require use of assets from different agencies. However, as the production of a single, consistent map product depicting the ground contamination is the primary goal, it is critical to establish very early into the event a common calibration line. Such a line should be flown periodically in order to normalize data collected from different aerial acquisition systems and potentially flown at different flight altitudes and speeds. In order to verify and validate individual aerial systems, the calibration line needs to be characterized in terms of ground truth measurements. This is especially important if the contamination is due to short-lived radionuclides. The process of establishing such a line, as well as necessary ground truth measurements, is described in this document.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-State Photomultiplier Development for Radiation Detection

We are pursuing the sensitivity of back-thinned silicon (BT Si) with the gain of an SSPM (Baker 2011). Working in collaboration with Radiation Monitoring Devices, Inc., we are designing and fabricating prototype devices. Our original idea spurred from hybrid designs of advanced image sensors that use the sensitivity of BT Si that is then bump bonded to a CMOS readout device. As shown in the graph below (right), the BT Si has a far superior quantum efficiency (QE) than the standard photocathode response available in photomultiplier tubes (PMTs). Collecting as many scintillation photons as possible is the first objective. There has been major concern that the prototype could not deliver the ~105 electronic gain of a PMT. However, recently developed SSPMs do provide the electronic gain needed. We are now pursuing the design of a BTSSPM. With a smaller footprint, the SSPM can potentially lead to a simple, compact deployment package. Because the SSPM can be pixelated and tiled, we foresee developing an imaging detector. Pinhole imaging of radiation sources is a well-exercised technology. Our implementation of the coded aperture (Marks 2010) imager provides a high throughput pinhole imager. We intend to apply miniature coded apertures to minimal pixel count SSPMs to evaluate image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation tool for optical design of PET detector modules including scintillator material and sensor array

The appearance of single photon avalanche diodes (SPADs) in the field of PET detector modules made it necessary to apply more complex optical design methods to refine the performance of such assemblies. We developed a combined simulation tool that is capable to model complex detector structures including scintillation material, light guide, light collection optics and sensor, correctly taking into account the statistical behavior of emission of scintillation light and its absorbance in SPADs. As a validation we compared simulation results obtained by our software and another optical design program. Calculations were performed for a simple PET detector arrangement used for testing purposes. According to the results, deviation of center of gravity coordinates between the two simulations is 0.0195 mm, the average ratio of total counts 1.0052. We investigated the error resulting from finite sampling in wavelength space and we found that 20 nm pitch is sufficient for the simulation in case of the given spectral dependencies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive assay of plutonium metal plates using a fast-neutron multiplicity counter

Here, we developed a fast-neutron multiplicity counter based on organic scintillators (EJ-309 liquid and stilbene). The system detects correlated photon and neutron multiplets emitted by fission reactions, within a gate time of tens of nanoseconds. The system was used at Idaho National Laboratory to assay a variety of plutonium metal plates. A coincidence counting strategy was used to quantify the 240 Pu effective mass of the samples. Coincident neutrons, detected within a 40-ns coincidence window, show a monotonic trend, increasing with the 240 Pu-effective mass (in this work, we tested the 0.005–0.5 kg range). After calibration, the system estimated the 240 Pu effective mass of an unknown sample ( 240 Pu eff >50 g) with an uncertainty lower than 1% in a 4-min assay time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum-dot doped polymeric scintillation material for radiation detection

In this study, scintillation and luminescence enhancement were observed in a Quantum Dot-doped scintillating polymer, facilitating energy transfer with polymer medium and scintillating dye. 2,5-diphenyloxazole (PPO) and Cadmium Sulfide (CdS) Quantum Dots (QD) with 418 nm emission coated with oleic acid were dispersed in a polyvinyl toluene (PVT) matrix with transparency retained. Under UV excitation a sharp emission was detected at 426 nm from minimal QD loading with possible indication of QD energy transfer. Scintillation enhancement was observed with different radioactive sources in PVT-PPO/QD polymer with a photomultiplier detector setup. The response to gamma and beta radiation was investigated with differences in the energy spectrum and a count increase observed with increased QD loading.

36 MATERIALS SCIENCE↗

MICROSTRUCTURED OPTICAL FIBER FOR X-RAY DETECTION

A novel scintillating optical fiber is presented using a composite micro-structured quartz optical fiber. Scintillating materials are introduced into the multiple inclusions of the fiber. This creates a composite optical fiber having quartz as a cladding with an organic scintillating material core. X-ray detection using these fibers is compared to a collimated cadmium telluride (CdTe) detector over an energy range from 10 to 40 keV. Results show a good correlation between the fiber count rate trend and that of the CdTe detector.

36 MATERIALS SCIENCE↗

NATALIE: A 32 detector integrated acquisition system to characterize laser produced energetic particles with nuclear techniques

We present a stand-alone system to characterize the high-energy particles emitted in the interaction of ultrahigh intensity laser pulses with matter. According to the laser and target characteristics, electrons or protons are produced with energies higher than a few mega electron volts. Selected material samples can, therefore, be activated via nuclear reactions. A multidetector, named NATALIE, has been developed to count the {beta}{sup +} activity of these irradiated samples. The coincidence technique used, designed in an integrated system, results in very low background in the data, which is required for low activity measurements. It, therefore, allows a good precision on the nuclear activation yields of the produced radionuclides. The system allows high counting rates and online correction of the dead time. It also provides, online, a quick control of the experiment. Geant4 simulations are used at different steps of the data analysis to deduce, from the measured activities, the energy and angular distributions of the laser-induced particle beams. Two applications are presented to illustrate the characterization of electrons and protons.

43 PARTICLE ACCELERATORS↗

Microstructured Optical Fiber for X-ray Detection

A novel scintillating optical fiber is presented using a composite micro-structured quartz optical fiber. Scintillating materials are introduced into the multiple inclusions of the fiber. This creates a composite optical fiber having quartz as a cladding with an organic scintillating material core. X-ray detection using these fibers is compared to a collimated cadmium telluride (CdTe) detector over an energy range from 10 to 40 keV. Results show a good correlation between the fiber count rate trend and that of the CdTe detector.

DeHaven, Stanton L.↗

A Case Study Correlating Innovative Gamma Ray Scanning Detection Systems Data to Surface Soil Gamma Spectrometry Results - 13580

HydroGeoLogic (HGL), Inc. completed a United States Environmental Protection Agency (USEPA) study to characterize radiological contamination at a site near Canoga Park, California. The characterized area contained 470 acres including the site of a prototype commercial nuclear reactor and other nuclear design, testing, and support operations from the 1950's until 1988 [1]. The site history included radiological releases during operation followed by D and D activities. The characterization was conducted under an accelerated schedule and the results will support the project remediation. The project has a rigorous cleanup to background agenda and does not allow for comparison to risk-based guidelines. To target soil sample locations, multiple lines of evidence were evaluated including a gamma radiation survey, geophysical surveys, historical site assessment, aerial photographs, and former worker interviews. Due to the time since production and decay, the primary gamma emitting radionuclide remaining is cesium-137 (Cs-137). The gamma ray survey covered diverse, rugged terrain using custom designed sodium iodide thallium-activated (NaI(Tl)) scintillation detection systems. The survey goals included attaining 100% ground surface coverage and detecting gamma radiation as sensitively as possible. The effectiveness of innovative gamma ray detection systems was tested by correlating field Cs-137 static count ratios to Cs-137 laboratory gamma spectrometry results. As a case study, the area encompassing the former location of the first nuclear power station in the U. S. was scanned, and second by second global positioning system (GPS)-linked gamma spectral data were evaluated by examining total count rate and nuclide-specific regions of interest. To compensate for Compton scattering from higher energy naturally occurring radionuclides (U-238, Th-232 and their progeny, and K-40), count rate ratios of anthropogenic nuclide-specific regions of interest to the total count rate were calculated. From the scanning data, locations with observed Cs-137 ratios exceeding six standard deviations above the mean ratio were mapped in high resolution [2]. Field teams returned to those locations to collect static count measurements using the same detection systems. Soil surface samples were collected at 30 locations and analyzed for Cs-137. An exponential correlation was identified between Cs-137 concentrations in surface soil and field-scanned Cs-137 ratios. The data indicate field minimum detectable concentration (MDC) of Cs-137 at 0.02 Bq/g (0.5 pCi/g) or lower depending on contaminant distribution in soil. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Memorandum of Understanding for the 2010 Meson Test Beam Program T-995: Muon Detector / Tail Catcher R&D

This is a memorandum of understanding between the Fermi National Accelerator Laboratory and experimenters from Fermilab, Indiana University, Northern Illinois University, University of Notre Dame, Wayne State University, INFN (Trieste / Udine, Roma I, Padova, Ferrara) who have committed to participate in beam tests to be carried out during the 2010 MTBF pro gram. The memorandum is intended solely for the purpose of providing a budget estimate and a work allocation for Fermilab, the funding agencies and the participating institutions. It reflects an arrangement that currently is satisfactory to the parties. However, it is recognized and anticipated that changing circumstances of the evolving research program will necessitate revisions. The parties agree to negotiate amendments to this memorandum which will reflect such required adjustments. The test objectives are to continue the development of extruded scintillator-based muon counters begun in T-956 with emphasis on the use of Si Pixelated Photon Detectors (PPDs). The R&D program outlined here continues the T-956 studies using particle beams to test long strip counters, up to 6m, and new prototype TB4 electronics developed at Fermilab which the experimenters expect will lead to the assembly of future large-scale integrated systems that may be the subject for a future proposal. For the purpose of this work, T-995 will require limited space and resources which may be compatible with other users' equipment in the testing area. The T-995 experimenters may not always require control of the beam. The T-995 experimenters will use some of the same apparatus that is to be used by the experimenters who will study total absorption dual readout calorimetry at MTest (experiment T-1004). The T-995 and T-I004 experimenters both use newly designed Fermilab electronics to digitize the shape of the PPD pulse corresponding to the scintillator output. Both projects will share most of the data acquisition software and typically they will share the same beam instrumentation (beam defining counters and coincidence circuits). Both sets of experimenters will share some of the same counting house logic and analysis software for on-line data analysis. Some of the T-995 and T-I004 manpower available to the two projects will work on both projects although many of the studies will not run concurrently.

43 PARTICLE ACCELERATORS↗