The use of Airborne Imaging Spectrometer (AIS) data to differentiate marsh vegetation

The Airborne Imaging Spectrometer (AIS) is a high spectral resolution (9.6-nm-wide bands between 0.9 and 2.4 microns) instrument. Analysis of AIS data revealed significant differences in characteristics of the spectral radiance curves of four types of wetland vegetation canopies (trees, broadleaf herbaceous, Spartina alterniflora, and S. patens/Distichlis spicata) in Delaware, enabling them to be distinguished. The single most useful spectral region was that between 1.40 and 1.90 microns. Differences in radiance values at various wavelengths between samples of the same vegetation type could potentially be used to estimate biomass. Thus, high spectral resolution spectrometry appears to have significant value for remote sensing studies of wetland vegetation.

Gross, M. F.↗

Compact FUV camera concept for Space Weather applications

Far ultraviolet (FUV) images of Earth from space have proven invaluable in revealing contextual phenomena associated with space weather in the high latitude auroral regions and, more recently with TIMED and IMAGE in the mid and equatorial regions. Images of this nature can be used to investigate compelling questions associated with the interaction of the ionosphere/mesosphere-magnetosphere-solar wind. Three such questions are: 1. What are the critical time and spatial scales that determine the coupling between the magnetosphere and ionosphere? 2. What are the sources and characteristics of ionospheric variability? 3. How does the configuration of the magnetosphere change as a function of internal boundary conditions established by the mesosphere/ionosphere and the external driving conditions of the solar wind? Observations that lead to quantitative analyses are required to significantly advance the state of knowledge with regard to the affects of space weather and the interaction between and within these regions of Geospace. Current available image data sets are sufficient for qualitative analysis and morphological investigations, and while quantitative analyses are possible, they are difficult and limited to few events at best. In order to qualitatively access the time, spatial, and causal phenomena on global scales, simultaneous images of various FUV emissions with a combination of better spatial, temporal and spectral resolution and sensitivity than currently available is required. We present an instrument concept that is being developed to improve the spatial, temporal and spectral resolution and sensitivity needed to perform the quantitative analysis that enable significant advancement in our understanding of the impact of space weather on Geospace. The approach is to use the self-filtering concept that combines the imaging and filtering functions and thus reduces the size of the 4-mirror off-axis optical system. The optical and filter design will de described and results of preliminary breadboard tests will be provided.

Spann, James↗

Imaging systems for the delineation of spectral properties of geologic materials in the visible and near-infrared

The current status of imaging systems for the identification of the spectral properties of geologic minerals in the visible and near infrared ranges is reviewed. The technical characteristics of the most important instruments are given, including the MSS and TM, the Airborne Imaging Spectrometer, (AIS) the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), and the Shuttle Imaging Spectrometer Experiment (SISEX). It is pointed out that none of the current systems have sufficient spectral resolution to identify mineralogy on the basis of absorption characteristics in the visible, near-infrared or shortwave-infrared bands. The development of new systems with higher spectral resolution is discussed.

Marsh, S. E.↗

Expected scientific performance of the three spectrometers on the extreme ultraviolet explorer

The expected in-orbit performance of the three spectrometers included on the Extreme Ultraviolet Explorer astronomical satellite is presented. Recent calibrations of the gratings, mirrors and detectors using monochromatic and continuum EUV light sources allow the calculation of the spectral resolution and throughput of the instrument. An effective area range of 0.2 to 2.8 sq cm is achieved over the wavelength range 70-600 A with a peak spectral resolution (FWHM) of 360 assuming a spacecraft pointing knowledge of 10 arc seconds (FWHM). For a 40,000 sec observation, the average 3 sigma sensitivity to a monochromatic line source is 0.003 photons/sq cm s. Simulated observations of known classes of EUV sources, such as hot white dwarfs, and cataclysmic variables are also presented.

Vallerga, J. V.↗

Concept Study for a Compact Planetary Homodyne Interferometer (PHI) for Temporal Global Observation of Methane on Mars in IR

We present a concept study to develop a new instrument to sequentially and over a long time measure methane abundance on Mars and find out its global seasonal variations, if any. The Planetary Homodyne Interferometer (PHI) can offer integrated spectra over a wide field-of-view (FOV) in high spectral resolution (R~10(exp 5)) in a compact design using no (or a small < 1m) primary mirror. PHI is best suited to studies of sources where temporally tracing specific spectral features sensitivity, and spectral resolution is of higher significance than spatial fidelity.

Extended targets↗

X-ray spectroscopy and imagery of supernova remnants with the Einstein Observatory

The two complementary spectroscopic instruments of the Einsten Observatory make possible X-ray spectroscopy of SNRs with considerably increased sensitivity and spectral resolution. The Solid State Spectrometer is a cryogenically cooled detector with 160 eV resolution, which suffices not only for the separation of lines due to different elements, but also the resolution of H-like, He-like and neutral lines from the same element for Si and above. The Focal Plane Crystal Spectrometer uses Bragg crystals to achieve excellent spectral resolution, but at the expense of sensitivity. Both instruments operate over most of the 0.2-4 keV energy band of the Einstein telescope, and are able to detect most of the important X-ray lines except the K lines of Fe and Ni.

Winkler, P. F.↗

eXTP: Enhanced X-Ray Timing and Polarimetry Mission

eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary goals are the determination of the equation of state of matter at supra-nuclear density, the measurement of QED effects in highly magnetized star, and the study of accretion in the strong-field regime of gravity. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time ever the simultaneous spectral-timing-polarimetry studies of cosmic sources in the energy range from 0.5-30 keV (and beyond). Key elements of the payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics for a total effective area of approx. 0.9 m(exp. 2) and 0.6 m(exp. 2) at 2 keV and 6 keV respectively, equipped with Silicon Drift Detectors offering less than 180 eV spectral resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon Drift Detectors, for a total effective area of approx. 3.4 m(exp. 2), between 6 and 10 keV, and spectral resolution better than 250 eV; the Polarimetry Focusing Array (PFA) - a set of 2 X-ray telescope, for a total effective area of 250 cm(exp. 2) at 2 keV, equipped with imaging gas pixel photoelectric polarimeters; the Wide Field Monitor (WFM) - a set of 3 coded mask wide field units, equipped with position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90 degrees field of view. The eXTP international consortium includes major institutions of the Chinese Academy of Sciences and Universities in China, as well as major institutions in several European countries and the United States. The predecessor of eXTP, the XTP mission concept, has been selected and funded as one of the so-called background missions in the Strategic Priority Space Science Program of the Chinese Academy of Sciences since 2011. The strong European participation has significantly enhanced the scientific capabilities of eXTP. The planned launch date of the mission is earlier than 2025.

X-ray astronomy↗

Development and Testing of a Superconducting Ground Plane on Transition Edge Sensors

Much of the normal matter in the universe is thought to exist as diffuse hot gas near 1.0 × 10 6 K, which can be detected through its 0.1–0.5 keV line emission. Distinguishing among multiple temperature regions and emission mechanisms along a line of sight requires resolving individual spectral lines in this particularly crowded spectral range. This requires 1–2 eV spectral resolution, which is currently only possible using grating spectrometers, which are suitable only for point sources, but not for the diffuse sources we wish to observe. We aim to measure individual spectral lines in this energy band using transition edge sensors (TES) that have the required 1–2 eV non-dispersive spectral resolution on a sounding rocket. While TESs offer sufficient energy resolution, they are very sensitive to ambient magnetic fields, e.g. from earth’s field and stray fields from the adiabatic demagnetization refrigerator (ADR) that is used to cool TESs to their ∼70 mK transition temperature. Strict space and weight limitations on the sounding rocket payload will limit the use of conventional high permeability magnetic shielding. Further design challenges arise in designing shielding with at least a 45∘ field of view, which is required to maintain a large enough throughput to obtain a useful spectrum on a brief (∼300 s) sounding rocket flight. Here we explore adding a superconducting ground plane (SGP) to the backside of the TES to reduce its field sensitivity and minimize attenuation requirements for the external shielding, which is based on prior work from (de Wit et al. 2022). We tested the feasibility of SGPs with novel materials, geometries, and on larger TESs with different biasing conditions.

Astrophysics↗

Echelle spectrographs at grazing incidence

It is shown that by using the conical diffraction mount, existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft X rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV, has a primary mirror and an entrance slit to the spectrograph. The system has a resolution of 10,000, operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The X-ray spectrograph uses objective gratings to obtain spectral resolution of 28,000 over any factor of 2 in. wavelength. It operates to wavelengths as short as 4 A.

Cash, W.↗

Multilayer Monochromator For Hard X Rays And Gamma Rays

Compact monochromator for hard x rays and gamma rays provides high spectral resolution with high throughput. Resembles instruments in "Compact X-Ray and Extreme-Ultraviolet Monochromator" (MFS-28499), "Scanning X-Ray or Extreme-Ultraviolet Monochromator" (MFS-28492), "Ultra-High-Spectral-Resolution X-Ray/EUV Monochromator" (MFS-28500), and "Four-Mirror X-Ray and Extreme-Ultraviolet Monochromator" (MFS-28498). Operates on principle of multilayer Bragg reflector. Used in nuclear, astronomical, and biomedical research, x-ray crystallography, research on processing materials, research in x-ray lasers, and x-ray lithography.

Hoover, Richard B.↗

Surface vs. atmospheric origin of 2.1-2.5 micron absorption features in the Martian spectrum

For 20 years the origin of subtle absorption features in the spectrum of Mars near 2.3 micro-m ('K' band: 1.9-2.5 micro-m) has been debated. This spectral region contains gaseous absorption features predominantly from CO2 and CO on Mars and from telluric H2O and CO2. The authors have obtained new higher spectral resolution telescopic K band spectra of 10 surface regions using the Infrared Telescope Facility (IRTF) at Mauna Kea during 1990. The goals were to confirm the existence of broad features seen at lower spectral resolution and to determine whether these bands are caused by atmospheric gases, surface (or airborne dust) minerals, or a combination of both.

Bell, James F., III↗

Velocity resolved spectroscopy of molecular hydrogen emission in NGC6240

NGC6240 is a member of the class of luminous galaxies which emit a significant fraction of their total light in the infrared. Based on its highly disturbed morphology, Fosbury and Wall (1979) suggested that the system may be a merger of two gas rich galaxies. It has two nuclei separated by 2 arcsec which are visible in the near infrared and at radio wavelengths and CO observations show that the galaxy contains a large mass of molecular gas. Unusually strong H2 emission lines dominate the near infrared spectrum of this galaxy. The galaxy emits approximately 4x10(exp 7) solar luminosity in the 2.12 micron v = 1 to 0 S(1) line alone, an order of magnitude more than other merging or starburst galaxies. To provide a better understanding of the physical processes responsible for the H2 emission from NGC6240 we have begun a program to obtain high spectral resolution observations using the echelle in CGS4 on the UKIRT. Preliminary data which were obtained in February 1991 are presented here. It is intended to obtain further observations with twice the spatial and spectral resolution in June of this year.

Wright, G. S.↗

Medium-resolution studies of extreme-ultraviolet emission from CO by electron impact

We report medium-resolution (0.025 nm full width at half maximum (FWHM)) electron impact-induced emission spectra of CO for 20, 100, and 200 eV impact energies. The emission spectra correspond to the extreme ultraviolet transitions from the B (sup 1)Sigma(sup +)(0), and E (sup 1)Pi(0) vibronic states to the X (sup 1)Sigma(sup +)(0) ground state. The present measurements are carried out at 20 times higher spectral resolution (to separate the many blended components) compared to our previous measurements, which were at a spectral resolution of 0.5 nm FWHM. The emission cross sections corresponding to the B (sup 1)Sigma(sup +)(0) yields X (sup 1)Sigma(sup +)(0), C (sup 1)Sigma(sup +)(0) yields X (sup 1)Sigma(sup +)(0), and E (sup 1)Pi(0) yields X (sup 1)Sigma(sup +)(0) resonance transitions were measured. In addition, excitation functions (0-1 keV) extending well into the Born region have been measured for the strong transitions (B (sup 1)Sigma(sup +)(0) yields X (sup 1)Sigma(sup +)(0) and C (sup 1)Sigma(sup +)(0)) and oscillator strengths have been determined, using a modified Born approximation analytic fit to the measured excitation function.

Kanik, Isik↗

NGC 1058: Gas motions in an extended, quiescent spiral disk

Researchers investigate in detail the motion of gas in the galaxy NGC 1058 using the very large array (VLA) to map the emission in the 21-cm line. This galaxy is so nearly face-on that the contribution to the line width due to the variation of the rotational velocity across the D-array beam is small compared with the random z-motion of the gas. Researchers confirm results of earlier studies (Lewis 1987, A. and A. Suppl., 63, 515; van der Kruit and Shostak 1984, A. and A., 134, 258) of the galaxy's total neutral hydrogen (HI) and kinematics, including the fact that the rotation curve drops faster than Keplerian at the outer edge of the disk, which is interpreted as a fortuitous twist of the plane of rotation in the outer disk. However, their very high velocity resolution (2.58 km s(exp -1) after Hanning smoothing) coupled with good spatial resolution, allows researchers to measure more accurately the line width, and even to some extent its shape, throughout the disk. One of the most interesting results of this study is the remarkable constancy of the line width in the outer disk. From radius 90 to 210 seconds the Gaussian velocity dispersion (sigma sub nu) of the 21-cm line has a mean value of 5.7 km s(exp -1) (after correcting for the spectral resolution) with a dispersion of less than 0.9 km s(exp -1) (after correcting for the spectral resolution) with a dispersion of less than 0.9 km s(exp -1). Translating this directly into a kinetic temperature (Doppler temperature): T sub Dopp equals 121K (sigma sub mu exp 2/(km s(exp -1) (exp 2) gives 4000 K, with a dispersion of less than 1500 K over the outer disk. This constancy is observed even when comparing the spiral arms versus inter-arm regions, which in the radius range from 100 to 150 seconds the surface density modulates (defined as the ratio N sub peak -N sub trough/N sub peak + N sub trough) from 0.5 to 0.25 in the range 150 to 200 seconds.

Hanson, Margaret Murray↗

Compact finite difference schemes with spectral-like resolution

The present finite-difference schemes for the evaluation of first-order, second-order, and higher-order derivatives yield improved representation of a range of scales and may be used on nonuniform meshes. Various boundary conditions may be invoked, and both accurate interpolation and spectral-like filtering can be accomplished by means of schemes for derivatives at mid-cell locations. This family of schemes reduces to the Pade schemes when the maximal formal accuracy constraint is imposed with a specific computational stencil. Attention is given to illustrative applications of these schemes in fluid dynamics.

Lele, Sanjiva K.↗

Introduction to AIRS and CrIS

"Introduction to AIRS and CrIS" is a chapter in a book dealing with various aspects of remote sensing. AIRS and CrIS are both high spectral resolution IR sounding instruments, which were recently launched (AIRS) or will soon be launched (CrIS). The chapter explains the general principles of infra-red remote sensing, and explains the significance and information content of high spectral resolution IR measurements. The chapter shows results obtained using AIRS observations, and explains why similar quality results should be obtainable from CrIS data.

Susskind, Joel↗

Remote sounding of tropospheric minor constituents

The etalon interferometer, or Fabry-Perot interferometer (FPI), with its high throughput and high spectral resolution was widely used in the remote-sensing measurements of the earth's atmospheric composition, winds, and temperatures. The most recent satellite instruments include the Fabry-Perot interferometer flown on the Dynamics Explorer-2 (DE-2) and the High Resolution Doppler Imager (HRDI) to be flown on the Upper Atmosphere Research Satellite (UARS). These instruments measure the Doppler line profiles of the emission and absorption of certain atmospheric species (such as atomic oxygen) in the visible spectral region. The successful space flight of DE-FPI and the test and delivery of UARS-HRDI demonstrated the extremely high spectral resolution and ruggedness of the etalon system for the remote sensing of earth and planetary atmospheres. Recently, an innovative FPI focal plane detection technique called the Circle-to-Line Interferometer Optical (CLIO) system was invented at the Space Physics Research Laboratory (SPRL). The CLIO simplifies the FPI focal plane detection process by converting the circular rings or fringes into a linear pattern similar to that produced by a conventional spectrometer, while retaining the throughput advantage of the etalon interferometer. CLIO makes the use of linear array detectors more practical and efficient with FPI, the combination of FPI and CLIO represents a very promising new technique for the remote sensing of the lower atmospheres of Earth, Mars, Venus, Neptune, and other planets. The Multiorder Etalon Spectrometer (MOES), as a combination of the rugged etalon and the CLIO, compares very favorably to other spaceborne optical instruments in terms of performance versus complexity. The feasibility of an advanced etalon spectrometer for the remote sensing of tropospheric trace species, particularly carbon monoxide (CO), nitrous oxide (N2O), and methane (CH4) was discussed. The etalon atmospheric spectroscopy techniques are described, instrument design and related technical issues are discussed. The primary objective is to establish the concept of atmospheric spectroscopy with the CLIO and etalon system and its applications for the measurements of tropospheric trace species analyze system requirements and performance, determine the feasibility of components and subsystem implementation with available technology, and develop inversion algorithm for retrieval simulation and data analysis.

Drayson, S. Roland↗

Ozone height profiles using laser heterodyne radiometer

The monitoring of vertical profiles of ozone and related minor constituents in the atmosphere are of great significance to understanding the complex interaction between atmospheric dynamics, chemistry and radiation budget. An ultra high spectral resolution tunable CO2 laser heterodyne radiometer has been designed, developed and set up at the National Physical Laboratory, New Delhi to obtain vertical profiles of various minor constituents the characteristic absorption lines in 9 to 11 micron spectral range. Due to its high spectral resolution the lines can be resolved completely and data obtained are inverted to get vertical profiles using an inversion technique developed by the author. In the present communication the salient features of the laser heterodyne system and the results obtained are discussed in detail.

Jain, S. L.↗