Search NASA⌕ Search

SEARCH · Search NASA

Results for “Silicon detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Novel Sensors for Particle Tracking: a Contribution to the Snowmass Community Planning Exercise of 2021

Five contemporary technologies are discussed in the context of their potential roles in particle tracking for future high energy physics applications. These include sensors of the 3D configuration, in both diamond and silicon, submicron-dimension pixels, thin film detectors, and scintillating quantum dots in gallium arsenide. Drivers of the technologies include radiation hardness, excellent position, vertex, and timing resolution, simplified integration, and optimized power, cost, and material.

Detectors↗

Novel Sensors for Particle Tracking: a Contribution to the Snowmass Community Planning Exercise of 2021

Five contemporary technologies are discussed in the context of their potential roles in particle tracking for future high energy physics applications. These include sensors of the 3D configuration, in both diamond and silicon, submicron-dimension pixels, thin film detectors, and scintillating quantum dots in gallium arsenide. Drivers of the technologies include radiation hardness, excellent position, vertex, and timing resolution, simplified integration, and optimized power, cost, and material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge Trap Analysis in a SENSEI Skipper-CCD: Understanding Low-Energy Backgrounds in Rare-Event Searches

Skipper Charge-Coupled Devices (Skipper-CCDs) are ultra-low-threshold detectors capable of detecting energy deposits in silicon at the eV scale. Increasingly used in rare-event searches, one of the major challenges in these experiments is mitigating low-energy backgrounds. In this work, we present results on trap characterization in a silicon Skipper-CCD produced in the same fabrication run as the SENSEI experiment at SNOLAB. Lattice defects contribute to backgrounds in rare-event searches through single-electron charge trapping. To investigate this, we employ the charge-pumping technique at different temperatures to identify dipoles produced by traps in the CCD channel. We fully characterize a fraction of these traps and use this information to extrapolate their contribution to the single-electron background in SENSEI. We find that this subpopulation of traps does not contribute significantly but more work is needed to assess the impact of the traps that can not be characterized.

Brusco, Agustin [Buenos Aires U.]↗

Design and construction of the CMS Outer Tracker for the Phase-2 Upgrade

he High Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of $3000-4000$~fb$^{-1}$ after 10 years of operation with peak instantaneous luminosity reaching about $5-7.5\times10^{34}$cm$^{-2}$s$^{-1}$. During Long Shutdown 3, several components of the CMS detector will undergo major changes, called Phase-2 upgrade, to be able to operate in the challenging environment of the HL-LHC. The current CMS silicon strip tracker has to be replaced with a new detector. The Phase-2 Outer Tracker (OT) will have higher radiation tolerance, higher granularity, and the capability to handle higher data rates compared to the current system. Another key feature of the OT will be to provide tracking information to the Level-1 (L1) trigger, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made out of modules with two closely spaced sensors read out by front-end ASICs, which can correlate hits in the two sensors creating short track segments called stubs. The stubs will be used for tracking in the L1 track finder. The modules come in two flavors: strip-strip (2S) and pixel-strip (PS), which contain different sensor configurations and multiple ASICs. In this contribution, the design of the CMS Phase-2 OT, the technological choices, and the quality assurance (QA) procedures used to ensure the functionality of the modules will be reported. The contribution will cover the first results with pre-production devices and the different aspects taken into account during the QA: from fulfilling the precision specification of the module assembly procedure to ensuring the proper communication between the different ASICs on the module. The module noise performance is also checked and the full module functionality is verified at different temperatures.

Zoi, Irene↗

Design and construction of the CMS Outer Tracker for the Phase-2 Upgrade

The High Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of $3000-4000\;$fb$^{-1}$ after 10 years of operation with peak instantaneous luminosity reaching about $5-7.5\times10^{34}$cm$^{-2}$s$^{-1}$. During Long Shutdown 3, several components of the CMS detector will undergo major changes, called Phase-2 upgrades, to be able to operate in the challenging environment of the HL-LHC. The current CMS silicon strip tracker has to be replaced with a new detector. The Phase-2 Outer Tracker (OT) will have high radiation tolerance, higher granularity and the capability to handle higher data rates. Another key feature of the OT will be to provide tracking information to the Level-1 trigger, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made out of modules which have two closely spaced sensors read out by front-end ASICs, which can correlate hits in the two sensors creating short track segments, called stubs. The stubs will be used for tracking in the L1 track finder. In this contribution, the design of the CMS Phase-2 OT, the technological choices and first results with prototype devices are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collider Physics (Final Technical Report)

The UNM members of the ATLAS Collaboration published a comprehensive study of ATLAS Pixel leakage current recorded from the beginning of Run 1 through the end of Run 2. This study depended upon a hardware system that was designed and built by UNM and installed by us in the ATLAS cavern. The study compared ATLAS data to predictions by the Hamburg Model, thereby leveraging ATLAS data to improve a widely used simulation that has application to other LHC experiments as well as silicon systems in radiation environments outside HEP applications. Having validated the model in this way, we then used it to make predictions for ATLAS tracker design and operational conditions in Run 3 and beyond.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TTDAQ: A Continuous Flow, Timing and Trigger DAQ System

Final Scientific/Technical Report for DOE Award DE-SC0019581, “TTDAQ: A Continuous Flow, Timing and Trigger DAQ System.” The report summarizes Telluric Labs’ Phase II STTR work developing silicon-photonic building blocks for a software-defined, continuous-flow, trigger-less data acquisition system for next-generation high-energy and nuclear-physics detectors. The project focused on radiation-hard photonic integrated circuits, remote optical illumination, dense wavelength-division multiplexing, and a differential microring-resonator transceiver architecture designed to improve high-speed optical link stability and bandwidth. The report describes project objectives, technical accomplishments, AIM Photonics tape-outs, bench characterization, radiation-hardness testing, deferred integration work, and potential applications beyond physics readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a phonon-mediated kinetic inductance detector at the NEXUS cryogenic facility

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the Northwestern EXerimental Underground Site (NEXUS) low-background facility at Fermilab for characterization and evaluation of this detector architecture’s efficacy for a DM search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470-nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of 2.1 ± 0.2 eV, a factor of two better than the current state of the art, enabled by quasiparticle lifetimes extending up to 6.5 ms. However, due to the subpercent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to σ E = 318 ± 29 eV. We further model both the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, and the observed noise spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

On-chip probabilistic inference for charged-particle tracking at the sensor edge

Modern scientific instruments operate under increasingly extreme constraints on bandwidth, latency, and power. Inference at the sensor edge determines experimental data collection efficiency by deciding which information to save for further analysis. Particle tracking detectors at the Large Hadron Collider exemplify this challenge: pixelated silicon sensors generate rich spatiotemporal ionization patterns, yet most of this information is discarded due to data-rate limitations. Concurrently, advancements in co-design tools provide rapid turn-around for incorporating machine learning into application-specific integrated circuits, motivating designs for particle detectors with new integrated technologies. We demonstrate that neural networks embedded in the front-end electronics can infer charged-particle kinematic parameters from a single silicon layer. We regress hit positions and incident angles with calibrated uncertainties, while satisfying stringent constraints on numerical precision, latency, and silicon area. Our results establish a path toward probabilistic inference directly at the edge, opening new opportunities for intelligent sensing in high-rate scientific instruments.

Das, Arghya Ranjan [Purdue U.] (ORCID:000000018451↗

Evaluation of 3D pixel silicon sensors for the CMS Phase-2 Inner Tracker

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R&D program, aiming at using 3D pixel silicon sensors in the innermost barrel layer of the detector, has been carried out by CMS in collaboration with the FBK (Trento, Italy) and CNM (Barcelona, Spain) foundries. The sensors will feature a pixel cell size of 25 × 100 µm 2 , with a centrally located electrode connected to the readout chip. The sensors are read out by the RD53A and CROCv1 chips, developed in 65 nm CMOS technology by the RD53 Collaboration, a joint effort between the ATLAS and CMS groups. This paper reports the results achieved in beam test experiments before and after irradiation, up to a fluence of approximately 2 . 6 × 1 0 16 n eq /cm 2 . Measurements of assemblies irradiated to a fluence of 1 × 10 16 n˙eq/cm 2 show a hit detection efficiency higher than 96% at normal incidence, with fewer than 2% of channels masked, across a bias voltage range greater than 50 V . Even after irradiation to a higher fluence of 1.6 × 10 16 n˙eq/cm 2 , similar performance is maintained over a bias voltage range of 30 V , remaining well within CMS requirements.

3D pixel↗

Reflectivity of VUV-sensitive silicon photomultipliers in liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. Here, the reflectivity is determined to be 25–36 % at an angle of incidence of 20° for the four samples and increases to up to 65 % at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

(pin diodes, APDs, SiPMs, G-APDs, CCDs, EBCCDs, EM↗

AstroPix: A pixelated HVCMOS sensor for space-based gamma-ray measurement

A next-generation medium-energy gamma-ray telescope targeting the MeV range would address open questions in astrophysics regarding how extreme conditions accelerate cosmic-ray particles, produce relativistic jet outflows, and more. One concept, AMEGO-X, relies upon the mission-enabling CMOS Monolithic Active Pixel Sensor silicon chip AstroPix. AstroPix is designed for space-based use, featuring low noise, low power consumption, and high scalability. Desired performance of the device include an energy resolution of 5 keV (or 10% FWHM) at 122 keV and a dynamic range per-pixel of 25–700 keV, enabled by the addition of a high-voltage bias to each pixel which supports a depletion depth of 500 μ m. This work reports on the status of the AstroPix development process with emphasis on the current version under test, version three (v3), and highlights of version two (v2). Version 3 achieves energy resolution of 10.4 ± 3.2% at 59.5 keV and 94 ± 6 μ m depletion in a low-resistivity test silicon substrate.

Astrophysics instrumentation↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

Search for long-lived charginos based on a disappearing-track signature using 136 fb -1 of pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search for long-lived charginos produced either directly or in the cascade decay of heavy prompt gluino states is presented. The search is based on proton–proton collision data collected at a centre-of-mass energy of $\sqrt{s}$ = 13 TeV between 2015 and 2018 with the ATLAS detector at the LHC, corresponding to an integrated luminosity of 136 fb -1 . Long-lived charginos are characterised by a distinct signature of a short and then disappearing track, and are reconstructed using at least four measurements in the ATLAS pixel detector, with no subsequent measurements in the silicon-microstrip tracking volume nor any associated energy deposits in the calorimeter. The final state is complemented by a large missing transverse-momentum requirement for triggering purposes and at least one high-transverse-momentum jet. No excess above the expected backgrounds is observed. Exclusion limits are set at 95% confidence level on the masses of the chargino and gluino for different chargino lifetimes. Chargino masses up to 660 (210) GeV are excluded in scenarios where the chargino is a pure wino (higgsino). For charginos produced during the cascade decay of a heavy gluino, gluinos with masses below 2.1 TeV are excluded for a chargino mass of 300 GeV and a lifetime of 0.2 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of POTATO for 2S Module Grading for the CMS Phase-2 Outer Tracker Upgrade

Due to the High Luminosity-Large Hadron Collider (HL-LHC) upgrade, several detectors of the Compact Muon Solenoid (CMS) will need to be upgraded, specifically the new Outer Tracker detector that will be composed of 13,200 silicon modules. The Outer Tracker features two types of modules; the PS (pixel-strip) and the 2S (strip-strip) modules. With a large influx of production of modules, extensive testing is required to ensure they fulfill the performance requirements. This research introduces POTATO (Phase-II Outer Tracker Analyzer of Test Outputs), a specialized software developed in C++ to analyze, grade, and store results in a centralized database since module data will be collected from various international production facilities. The implementation of POTATO will facilitate the selection of the best performing modules for the Outer Tracker upgrade. This paper is focused on the implementation of the analysis of 2S Module results within POTATO.

43 PARTICLE ACCELERATORS↗

Beam dynamics corrections in the measurement of the anomalous precession frequency at the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon with an accuracy of 140 ppb (parts per billions). This accuracy, obtained by adding in quadrature a statistical and a systematic contribution of comparable value (100 ppb), will allow to reduce the experimental uncertainty (from the previous E821 experiment at BNL \cite{bnl}) of a factor of 4, and represents one of the most precise tests of the Standard Model (SM) theory of elementary particles. The first result on the Run-1 dataset \cite{prl} was released on April 7, 2021, showing a very good agreement with the previous result from BNL experiment, with a slightly better uncertainty. The corresponding experimental average increases the significance of the discrepancy between the measured and Standard Model prediction of 4.2$\sigma$ \cite{white_paper}.\\ \noindent The measured quantity is the muon magnetic anomaly a$_\mu$=$\frac{g_\mu-2}{2}$ where g$_\mu$ is the gyromagnetic factor of the muon. Dirac's equation predicts g$_\mu$ = 2, while radiative corrections, dominated by the QED contribution due to an exchange of a virtual photon, causes a per-mille correction on this quantity. By including all the SM contributions, a$_\mu$ is known at 370 ppb. The E989 experiment measures $a_\mu$ injecting positive muons with momentum of 3.1 GeV/$c$ polarized longitudinally in bunches (called $fills$) with an average rate of 12 Hz, in a storage ring of 14 meters diameter. Due to the parity violation in the weak muon decay, high energy positrons produced are emitted preferably in the muon's spin direction. By counting the number of positrons with energy greater then 1.7 GeV in function of the time, the frequency precession of the muon spin is measured, that together with the measurement of the magnetic field, allows to extract $a_\mu$. The positrons are detected with 24 electromagnetic calorimeters, that measure the energy and the arrival time of the positrons, each made of 54 crystals of lead fluoride (PbF$_2$) read by silicon photomultipliers (SiPM). Together with calorimeters, two tracking detectors are used to make non-destructive measurements of the muon beam characteristic by reconstructing the muon decay position extrapolating backward the decay positrons. The knowledge of the beam motion inside the ring plays a fundamental role in the analysis of $a_{\mu}$, where the measured anomalous precession frequency $\omega_a$ must be corrected for four main beam dynamics effects. A first correction is associated with the presence of an electric field responsible of the vertical focusing on the storage ring, where vertical direction is orthogonal to the orbit and horizontal direction is along the storage ring radius. Due to the oscillations in the vertical direction, the so called vertical betatron oscillations, a second correction is necessary to account for an average angle associated with the muon motion off the ideal orbit. A third correction is caused by lost muons in the ring which have a different spin phase at the injection respect to the decay ones. Finally, due to the correlation between the vertical and horizontal beam motion of the muons and the acceptance of the calorimeter, a correction (called ``phase-acceptance") arises. In Run1, due to the presence of two damaged resistors in one electrostatic quadrupole, this correction had a prominent role. The replacement of the damaged resistors before Run2 decreased this effect by one order of magnitude, and a further reduction in Run-3 was provided by an improved orbit.\\ \noindent The work of this Thesis focuses on the beam dynamics corrections on $\omega_a$. Due to the prominent role in Run-1 a special attention has been put to the phase-acceptance correction\footnote{The effect of this correction on the E821 BNL measurement of the $g-2$ has been evaluated to be within the quoted systematic error.}. Chapter \ref{ch:anomalous_magnetic_moment} introduces the anomalous magnetic moment of the muon. Chapter \ref{ch:early_experiment} describes the history of the Muon $g-2$ experiments. Chapter \ref{ch:theory} discusses the Standard Model prediction and possible new physics scenario. Chapter \ref{ch:muon_g2_experiment} describes the E989 experiment, whose experimental technique and the apparatus are discussed focusing on the improvements needed to reach the final goal on $a_\mu$ measurement. The original work of the Thesis is discussed in the last 5 chapters. Chapter \ref{ch:experiment_technique} presents the analysis technique to extract $\omega_a$, Chapter \ref{ch:beam_dynamics} describes the beam dynamics in the E989 experiment, Chapter \ref{ch:beam_dynamics_correction} discusses the beam dynamics correction to $\omega_a$, and Chapter \ref{sec:pa_corr} focuses on the phase acceptance correction. Finally Chapter \ref{ch:run23_analysis_improvements} contains the Run-2/3 improvements which are expected to allow for an increased precision ons the beam dynamics co...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗