Search NASA⌕ Search

SEARCH · Search NASA

Results for “Voltage Acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Development of planar P-type point contact germanium detectors for low-mass dark matter searches

The detection of low-energy deposition in the range of sub-eV through ionization using germanium (Ge) with a bandgap of ~ 0.7 eV requires internal amplification of the charge signal. This can be achieved through high electric field that accelerates charge carriers, which can then generate more charge carriers. The minimum electric field required to generate internal charge amplification is derived for different temperatures. We report the development of a planar point contact Ge detector in terms of its fabrication and the measurements of its leakage current and capacitance as a function of applied bias voltage. With the determination of the measured depletion voltage, the field distribution is calculated using GeFiCa, which predicts that the required electric field for internal charge amplification can be achieved in proximity to the point contact. The energy response to an Am-241 source is characterized and discussed. We conclude that such a detector with internal charge amplification can be used to search for low-mass dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

PID-Regulated Heating System for PIP-II Reference Line

The Proton Improvement Project-2 centers on building a new superconducting linear particle accelerator (Linac) at Fermilab. At the heart of the accelerator is the reference line, a critical system that defines the ideal path for the particle beam as it passes through magnets, RF cavities, and other beamline elements. Temperature stability is crucial for the reliable operation of RF components, such as mixers and filters. Fluctuations affect key performance parameters like conversion loss, isolation, and linearity. To mitigate any drift caused by ambient temperature changes, a heating plate assembly is utilized to maintain key components at a controlled temperature of 40°C. The system utilizes an aluminum 36”x36”x0.5” heat plate powered by a MOSFET-based control circuit, delivering approximately 460 W of thermal energy through a resistor array. Real-time temperature feedback is provided by a PT100 Resistance Temperature Detector (RTD), which interfaces with a Proportional–Integral–Derivative (PID) control algorithm to maintain closed-loop temperature regulation. The control signal actively modulates the gate voltage of an N channel MOSFET, dynamically adjusting power delivery in response to deviations from the temperature setpoint. Simulations and LTspice models validate the functionality and responsiveness of the circuit under varying conditions. The prototype has successfully demonstrated stable thermal control, paving the way for integration into the PIP-II infrastructure. The final design will feature an expanded resistor array, as well as communication with a PLC for continuous data acquisition and diagnostics. This work directly supports Fermilab’s broader mission by contributing to the stability and reliability of core accelerator systems, enhancing the precision of particle beam delivery for future physics experiments.

Mosher, Alexander [Fermilab]↗

Glass/glass photovoltaic module reliability and degradation: a review

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

14 SOLAR ENERGY↗

Coherent Strain-Inhibiting Phase Construction of Lithium-Rich Manganese-Based Oxide Toward High Mechanochemical Stability

A layered lithium-rich manganese-based oxide cathode, containing $R\overline{3}m$ (LiTMO 2 , TM = Mn, Ni, Co) and $C2/m$ (Li 2 MnO 3 ) nanodomains, utilizes both transition metals and oxygen redox to yield substantial energy density. However, the inherent heterogeneous nature and distinct nanodomain redox chemistries of layered lithium-rich oxides will inevitably cause pernicious lattice strain and structural displacement, which can hardly be eliminated by conventional doping or coating strategies and result in accelerated performance decay. Herein, we incorporate a strain-inhibiting perovskite phase coherently grown within the layered structure to effectively restrain the displacement and lattice strain during uneven Li-ion extraction. The enhanced mechanochemical stability of the designed cathode benefits the persistent structure and reversible oxygen redox, thereby achieving high initial Coulombic efficiency and stable cycling and voltage profiles. In conclusion, our approach of lattice engineering alleviates the strain and displacement caused by inhomogeneous reactivity between heterogeneous nanodomains and promotes the development of advanced cathode materials with long durability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Erosion of focus rings in capacitively coupled plasma etching reactors

In plasma etching reactors, the structure surrounding the wafer, often called a focus ring (FR), plays an important role in maintaining uniform fluxes of reactants across the wafer. The FR is typically made of dielectric materials. During the plasma etching process, the sheath that forms over the wafer to accelerate ions anisotropically into the surface extends over the FR. Electrical charging of the FR modifies the sheath relative to that over the wafer. On the one hand, one wants the sheath to be uniform across the wafer-FR boundary to enable uniform fluxes to the edge of the wafer. On the other hand, maintaining a high voltage sheath over the FR will erode the FR, which is undesirable as the FR is a consumable component that must be periodically replaced in high volume manufacturing. In this work, we computationally investigated the consequences of dielectric constant ε of the FR materials on erosion of the FR. The series capacitance of the FR and its underlying structure is typically smaller than that of the wafer and its underlying structure. As a result, the FR charges quickly relative to the wafer, which then reduces the voltage across the sheath on top of the FR. The ion energy and angular distributions (IEADs) striking the FR are, therefore, generally lower in energy with a broader angular distribution. With ε = 2, the ion energies striking the middle to the outer edge of the FR are 30–180 eV, whereas for ε = 100, the ion energies are 120–380 eV. At the transition between the wafer and the FR, there is a skew in the IEAD as large as 15° that results from the difference in sheath thickness above the wafer and the FR. This skew and the erosion rate across the FR are functions of the dielectric constant of the FR material. With low ε, the FR charges quickly, less plasma is produced above the FR, and there is less voltage across the sheath that results in less FR erosion. Increasing ε of the FR produces a higher sheath voltage as well as higher ion fluxes over the FR, which increases erosion, while the skew at the edge of the wafer is less severe. Further, the material of the subsurface portion of the FR, which dominates its capacitance, is an important consideration in the design of the substrate assembly.

36 MATERIALS SCIENCE↗

Evaluation of bifacial module technologies with combined–accelerated stress testing

In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. Furthermore, this is attributed to previous X-ray topography and modeling work showing higher stress in cells and interconnections in glass-glass modules than glass-backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. We found light-induced degradation (LID) in module types with regenerated (inactive) cells with C-AST, suggesting the possibility of LID destabilization in some field conditions. We could also distinguish potential-induced degradation (PID) on the back of the bifacial passivated emitter and rear cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass-glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while –1200 V system voltage is applied in C-AST, supporting the conclusion that this module type with glass-glass construction would be susceptible to PID in the field.

14 SOLAR ENERGY↗

IMoFi - Intelligent Model Fidelity: Physics-Based Data-Driven Grid Modeling to Accelerate Accurate PV Integration (Final Report)

This report summarizes the work performed under a project funded by U.S. DOE Solar Energy Technologies Office (SETO) to use grid edge measurements to calibrate distribution system models for improved planning and grid integration of solar PV. Several physics-based data-driven algorithms are developed to identify inaccuracies in models and to bring increased visibility into distribution system planning. This includes phase identification, secondary system topology and parameter estimation, meter-to-transformer pairing, medium-voltage reconfiguration detection, determination of regulator and capacitor settings, PV system detection, PV parameter and setting estimation, PV dynamic models, and improved load modeling. Each of the algorithms is tested using simulation data and demonstrated on real feeders with our utility partners. The final algorithms demonstrate the potential for future planning and operations of the electric power grid to be more automated and data-driven, with more granularity, higher accuracy, and more comprehensive visibility into the system.

14 SOLAR ENERGY↗

Predicting Trends in VOC Through Rapid, Multimodal Characterization of State-of-the-Art p-i-n Perovskite Devices

Perovskite photovoltaic technologies are approaching commercial deployment, yet single junction and tandem architectures both still have significant room to improve power conversion efficiency and stability. The ability to perform rapid screening of material quality after altering processing conditions is critical to accelerating the optimization and commercialization of perovskite-based technologies. Currently, researchers utilize a wide range of stand-alone metrology tools to isolate sources of power loss throughout a device stack, which can be slow and labor intensive. Here, we demonstrate the use of a multimodal metrology approach to rapidly determine the maximum achievable and predicted open circuit voltages of >100 perovskite devices during fabrication. Acquisition of these different data is facilitated by combining them into a single integrated measurement platform. We show that these data and automated analysis can be used to rapidly understand and ultimately predict quantitative trends in open circuit voltages of state-of-the-art device architectures. The data and automated analysis workflow presented provides a reliable approach to quickly identify absorber and charge transport layer combinations that can lead to improved open circuit voltages.

14 SOLAR ENERGY↗

Degradation behavior of CIGS solar Cells: A parametric analysis

A parametric study of the effect of bulk and interface properties on device characteristics as a function of heat and light stress under open-circuit and short-circuit conditions is developed for Cu(In,Ga)(S,Se) 2 solar cells using SCAPS-1D simulator. The variables and interdependencies modeled include: (1) conduction band offset (CBO) between buffer and absorber; (2) buffer ionized donor density; (3) CIGS shallow acceptor density; (4) CIGS deep acceptor density; (5) CIGS shallow donor density; (6) ionized acceptor concentration in the ordered vacancy compound (OVC) CIGS/buffer interface; and (7) back contact work-function. An increase in absorber shallow acceptor or a decrease in shallow donor density results in an increase in net carrier density and open-circuit voltage (V OC ). Further, a decrease in V OC is observed with an increase in the deep acceptors or neutral midgap defects in the CIGS due to higher charge carrier recombination. A change of CBO from spike to cliff condition is a dominant mechanism of decreasing VOC with an interface defect density of 10 12 cm -2 . The minimum depletion width is found to be specifically sensitive to CBO and interface defect density. An inflection in the capacitance–voltage curves (in reverse bias) is observed with simultaneous increase in bulk deep acceptor density and shallow donor density near the back contact.

14 SOLAR ENERGY↗

Multiscale Characterization of Photovoltaic Modules—Case Studies of Contact and Interconnect Degradation

The current popularity of photovoltaic (PV) systems is due in large part to their exceptional reliability and significantly lower cost than other energy sources. Studying cell and module degradation is key to promote further development in the state of the art. Fielded or accelerated aged modules exhibit different failure modes, of which metallization degradation (contacts and interconnections) is prevalent. In this work, we discuss how multiscale characterization methods can be applied to a variety of module technologies that have been field exposed and have undergone accelerated age testing. These methods include performing characterization on the module level, cell level, and finally the materials level. The observed performance losses from the module- and cell-level characterization can be correlated with materials properties to find out the root cause of degradation. We recommend an initial nondestructive characterization suite, including module- and cell-level current-voltage ( I--V ), Suns-V OC , photoluminescence and electroluminescence imaging, quantum efficiency, ultraviolet fluorescence imaging, and thermal infrared imaging. Samples are then extracted from particularly degraded regions of the module and prepared for materials characterization techniques, such as top-down and cross-sectional scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, secondary ion mass spectrometry, Raman spectroscopy, and transmission electron microscopy, allowing a deeper look into the mechanism behind the metallization degradation. This article serves as an instructional review to introduce the different multiscale characterization methods and how they can be effectively applied to perform PV degradation studies. Furthermore, we also share some of our examples and discuss the strengths, limitations, and best practices for each of the characterization techniques.

14 SOLAR ENERGY↗

Performance Evaluation of Distributed Energy Resource Management Algorithm in Large Distribution Networks

This paper presents performance evaluation of hierarchical optimization and control for distributed energy resource management system (DERMS) in large distribution networks via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory environment, including the accurate modeling of a full-scale distribution system of 11,000 nodes, the DERMS software controller, and 90 power hardware photovoltaics (PVs) and battery inverters. The applied DERMS algorithm is designed based on a realtime optimal power flow algorithm and implemented with acceleration design that performs fast dispatch of simulated PVs and real physical hardware DER devices every 4 seconds.

DERMS↗

Auto-BLAST (AutoBLAST) [SWR-20-93]

Battery life modeling often involves a lot of manual parameter fitting and is not easy for users to adopt the model and use it. To reduce the difficulties for users to adopt battery lifetime models, an automatic battery lifetime modeling analysis and simulation tool suite, Auto-BLAST, has been developed. Auto-BLAST includes a lithium-loss-base life model, a battery electric model, and an algorithm which automatically fits all key parameters in the electric and life models using user provided data. The models and algorithm are packaged into two user-friendly GUIs, Auto-LifeMod, for easy battery life prognostic model fitting and Auto-LifeSim, for easy battery lifetime simulation. The lithium-loss-based life model adopts a similar model framework that models degradations using aging rate models, using battery cycling data to predict battery degradation and expected lifetime. The electric model is an equivalent circuit model which simulates battery voltage responses based on current/power demand profiles. The auto-fitting algorithm uses the user-input data to generate custom battery life model(s). Two GUIs, wrapping around the life model and the auto-fitting algorithm, provide friendly interfaces for users to generate a life model and use it for case study. One GUI requires summary data from accelerated battery life degradation tests as an input and produces battery life models predicting (a) capacity degradation, and (b) resistance growth of the battery. The GUI displays the electrical model response and the input experimental data against the life model predictions with fitted model parameters and fitting error. The GUI also generates an output file to save the fitted model parameters. The second GUI uses the life model from the first GUI and a user-defined battery cycling profile to predict battery lifetime degradation and expected lifetime. Predicted capacity and resistance vs. time are plotted in the GUI and saved to output file. There is a user guide for both GUIs

Mishra, Partha↗

CO 2 electrolysis to multicarbon products in strong acid

Carbon dioxide electroreduction (CO 2 R) is being actively studied as a promising route to convert carbon emissions to valuable chemicals and fuels. However, the fraction of input CO 2 that is productively reduced has typically been very low, <2% for multicarbon products; the balance reacts with hydroxide to form carbonate in both alkaline and neutral reactors. Acidic electrolytes would overcome this limitation, but hydrogen evolution has hitherto dominated under those conditions. We report that concentrating potassium cations in the vicinity of electrochemically active sites accelerates CO 2 activation to enable efficient CO 2 R in acid. We achieve CO 2 R on copper at pH <1 with a single-pass CO 2 utilization of 77%, including a conversion efficiency of 50% toward multicarbon products (ethylene, ethanol, and 1-propanol) at a current density of 1.2 amperes per square centimeter and a full-cell voltage of 4.2 volts.

Huang, Jianan Erick↗

Development of an ultraprecise glue-free bimorph deformable mirror with a length of 460 mm

Lead zirconate titanate (PZT) bimorph mirrors are essential for performing multiple functions, such as beam shaping, wavefront correction, and dynamic focusing with adjustable beam sizes. They typically consist of a mirror substrate with PZT electrodes bonded to the substrate using a thin epoxy film. However, glue-bonded PZT mirrors exhibit low reproducibility in measurement results. One source of this variability is water absorption by the substrate’s epoxy adhesive during wet fabrication processes, such as elastic emission machining (EEM), which leads to swelling and deformation. Additionally, longer deformable bimorph mirrors require larger PZT electrodes, further complicating their design and fabrication, particularly during bonding and ultraprecise metrology. To address these challenges, silver nanoparticles were employed to bond PZT elements to the silicon (Si) mirror, eliminating the need for epoxy glue. Here, in this study, we developed an inorganic-glue-free PZT bimorph mirror with a length of 460 mm and 28 channels. The glue-free bonding method successfully ensured the high reproducibility of measurements after water immersion. This approach resulted in a shape error of only 0.41 nm root mean square after the figure correction process using an ultraprecise EEM process. Scanning acoustic tomography and basic response function tests confirmed the success of the bonding process, showing no critical voids. Furthermore, the shape changes induced by applying voltages to the PZT electrodes closely matched predictions obtained from simulations. These results demonstrate the reliability and precision of the proposed glue-free bonding technique, paving the way for improved performance of new PZT bimorph mirrors.

Ichii, Yoshio [SLAC National Accelerator Laborator↗

Pathways for a compact double-quarter wave cavity with low peak surface fields and large deflecting kick

This paper describes the parameter choices necessary to obtain a compact Double Quarter Wave (DQW) cavity with low peak surface fields – electric and magnetic – and large deflecting kick. The work is motivated by the space limitations and demanding crabbing voltage required for the crabbing system of the Electron-Ion Collider (EIC) and focuses on the optimization of the 197 MHz crab cavities for the EIC’s hadron ring. For a crabbing voltage of 11.5 MV, the optimized cavity is less than one meter long, showing a maximum peak surface magnetic field of 70 mT and a maximum peak surface electric field of 45 MV/m.

43 PARTICLE ACCELERATORS↗

Recent developments in catalyst-related PEM fuel cell durability

Cost and durability remain the two major barriers to the widespread commercialization of polymer electrolyte membrane fuel cell (PEMFC)-based power systems, especially for the most impactful but challenging fuel cell electric vehicle (FCEV) application. Commercial FCEVs are now on the road; however, their PEMFC systems do not meet the cost targets established by the U.S. Department of Energy, primarily due to the high platinum loading needed on the cathode to achieve the requisite performance and lifetime. Furthermore, while the activities of a number of commercial Pt-based alloy cathode catalysts exceed the beginning-of-life (BOL) targets, these activities, and the overall cathode performance, degrade via a variety of mechanisms described herein. Degradation is mitigated in current FCEVs by utilizing a cathode catalyst with a lower BOL activity (e.g., much lower transition metal alloy content and larger BOL nanoparticle size), necessitating higher catalyst loadings, and through the utilization of system controls that avoid conditions known to exacerbate degradation processes, such as limiting the fuel cell stack voltage range. The design and development of active and robust materials and eliminating the need for vehicle mitigation strategies would greatly simplify the operating system, allowing for greater transient operation, avoiding large hybridization, and curtailing of fuel cell power. Although system mitigation strategies have provided the near-term pathway for FCEV commercialization, material-specific solutions are required to further reduce costs and improve operability and efficiency. Future material developments should focus on stabilization of the electrode structure and minimization of the catalyst particle susceptibility to dissolution caused by oxide formation and reduction over PEMFC cathode-relevant operating potentials plus minimization of support corrosion. Ex situ accelerated stress tests have provided insight into the processes responsible for material and performance degradation and will continue to provide useful information on the relative stability of materials and benchmarks for robust and stable materials-based solutions not requiring system mitigation strategies to achieve adequate lifetime.

25 ENERGY STORAGE↗