Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

SURPHEX (tm): New dry photopolymers for replication of surface relief diffractive optics

High efficiency, deep groove, surface relief Diffractive Optical Elements (DOE) with various optical functions can be recorded in a photoresist using conventional interferometric holographic and computer generated photolithographic recording techniques. While photoresist recording media are satisfactory for recording individual surface relief DOE, a reliable and precise method is needed to replicate these diffractive microstructures to maintain the high aspect ratio in each replicated DOE. The term 'high aspect ratio' means that the depth of a groove is substantially greater, i.e. 2, 3, or more times greater, than the width of the groove. A new family of dry photopolymers SURPHEX was developed recently at Du Pont to replicate such highly efficient, deep groove DOE's. SURPHEX photopolymers are being utilized in Du Pont's proprietary Dry Photopolymer Embossing (DPE) technology to replicate with very high degree of precision almost any type of surface relief DOE. Surfaces relief microstructures with width/depth aspect ratio of 1:20 (0.1 micron/2.0 micron) were faithfully replicated by DPE technology. Several types of plastic and glass/quartz optical substrates can be used for economical replication of DOE.

Shvartsman, Felix P.↗

Liquid crystal point diffraction interferometer

A new instrument, the liquid crystal point diffraction-interferometer (LCPDI), has been developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point diffraction interferometer (PDI) and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with very high data density and with automated data reduction. This dissertation describes the theory of both the PDI and liquid crystal phase control. The design considerations for the LCPDI are presented, including manufacturing considerations. The operation and performance of the LCPDI are discussed, including sections regarding alignment, calibration, and amplitude modulation effects. The LCPDI is then demonstrated using two phase objects: defocus difference wavefront, and a temperature distribution across a heated chamber filled with silicone oil. The measured results are compared to theoretical or independently measured results and show excellent agreement. A computer simulation of the LCPDI was performed to verify the source of observed periodic phase measurement error. The error stems from intensity variations caused by dye molecules rotating within the liquid crystal layer. Methods are discussed for reducing this error. Algorithms are presented which reduce this error; they are also useful for any phase-stepping interferometer that has unwanted intensity fluctuations, such as those caused by unregulated lasers.

Mercer, Carolyn R.↗

A phase-stepped point diffraction interferometer using liquid crystals

A new instrument, the liquid crystal point diffraction interferometer (LCPDI), has been developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point diffraction interferometer (PDI) and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with high data density and with automated data reduction. The design of the LCPDI is briefly discussed. An algorithm is presented for eliminating phase measurement error caused by object beam intensity variation from frame-to-frame. The LCPDI is demonstrated by measuring the temperature distribution across a heated chamber filled with silicone oil. The measured results are compared to independently measured results and show excellent agreement with them. It is expected that this instrument will have application in the fluid sciences as a diagnostic tool, particularly in space based applications where autonomy, robustness, and compactness are desirable qualities. It should also be useful for the testing of optical elements, provided a master is available for comparison.

Mercer, Carolyn R.↗

A diffraction-limited far-infrared imager for the KAO

We describe both our current instrument and a follow-on instrument expected to be operational at the start of the next flight year on the KAO. The current instrument uses a 20-channel bolometer array arranged in two columns of 10 detectors each. Broadband observations can be made at the true diffraction limit, lambda/2D, at either 50 or 100 microns during a flight. Our forthcoming system will use two arrays of 3 x 10 detectors to enable simultaneous imaging at both 50 and 100 microns at the KAO diffraction limit for each wavelength. Observing modes and typical sensitivities will be discussed.

Harvey, Paul M.↗

Liquid-Crystal Point-Diffraction Interferometer

Liquid-crystal point-diffraction interferometer (LCPDI) invented to combine flexible control of liquid-crystal phase-shifts with robustness of point-diffraction interferometers. Produces interferograms indicative of shapes of wavefronts of laser beams having passed through or reflected from objects of interest. Interferograms combined in computers to produce phase maps describing wavefronts.

Mercer, Carolyn R.↗

Neutron diffraction measurements and modeling of residual strains in metal matrix composites

Neutron diffraction measurements at room temperature are used to characterize the residual strains in tungsten fiber-reinforced copper matrix, tungsten fiber-reinforced Kanthal matrix, and diamond particulate-reinforced copper matrix composites. Results of finite element modeling are compared with the neutron diffraction data. In tungsten/Kanthal composites, the fibers are in compression, the matrix is in tension, and the thermal residual strains are a strong function of the volume fraction of fibers. In copper matrix composites, the matrix is in tension and the stresses are independent of the volume fraction of tungsten fibers or diamond particles and the assumed stress free temperature because of the low yield strength of the matrix phase.

Saigal, A.↗

Microbial Diffraction Gratings as Optical Detectors for Heavy Metal Pollutants

As a significant industrial pollutant, cadmium is implicated as the cause of itai-itai disease. For biological detection of cadmium toxicity, an assay device has been developed using the motile response of the protozoa species, Tetrahymena pyriformis. This mobile protozoa measures 50 microns in diameter, swims at 10 body lengths per second, and aggregates into macroscopically visible patterns at high organism concentrations. The assay demonstrates a Cd(+2) sensitivity better than 1 micro-M and a toxicity threshold to 5 micro-M, thus encouraging the study of these microbial cultures as viable pollution detectors. Using two-dimensional diffraction patterns within a Tetrahymena culture, the scattered light intensity varies with different organism densities (population counts). The resulting density profile correlates strongly with the toxic effects at very low dosages for cadmium (less than 5 ppm) and then for poison protection directly (with nickel and copper antagonists competing with cadmium absorption). In particular, copper dosages as low as 0.1-0.5 mM Cu have shown protective antagonism against cadmium, have enhanced density variability for cultures containing 1 mM Cd(+2) and therefore have demonstrated the sensitivity of the optical detection system. In this way, such microbial diffraction patterns give a responsive optical measure of biological culture changes and toxicity determination in aqueous samples of heavy metals and industrial pollutants.

Noever, David↗

Liquid-Crystal Point-Diffraction Interferometer for Wave-Front Measurements

A new instrument, the liquid-crystal point-diffraction interferometer (LCPDI), is developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point-diffraction interferometer and adds to it a phase-stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wave fronts with very high data density and with automated data reduction. We describe the theory and design of the LCPDI. A focus shift was measured with the LCPDI, and the results are compared with theoretical results,

Mercer, Carolyn R.↗

Defining X-Ray Diffraction Parameters for the Design and Operation of a Planetary-Surface Rock Analyzer

Our joint research effort was aimed at developing techniques for X-ray diffractometry that was being investigated by NASA as possible flight instrumentation for the exploration of Mars. SJSU would provide the use of in-house X-ray facilities for calibration of the instrumentation , and would provide technical expertise regarding interpretation of data acquired during both laboratory testing, and during field testing of instruments on the Marsokhod rover at Ames. Accomplishments are: (1) quantification of X-ray signals from rock surfaces using San Jose State University (SJSU) diffractometer; (2) development of criteria for fingerprinting rock samples using pattern recognition of diffraction spectra, and augmentation of diffraction data with X-ray fluorescence information; (3) calibration of NASA instrumentation using SJSU-generator data; and (4) assistance in the development, lab testing, and field deployment of the NASA instrument on the Russian Marsokhod roving vehicle designed for martian exploration.

Metzger, Ellen P.↗

X-ray Diffraction Studies of the Structure and Thermochemistry of Alkaline-Earth Oxide-Coated Thermionic Cathodes

NASA LeRC has a broad, active cathode technology development program in which both experimental and theoretical studies are being employed to further development of thermionic cathodes for use as electron sources in vacuum devices for communications and other space applications. One important type of thermionic cathode under development is the alkaline-earth oxide-coated (BaO, SrO, CaO) cathode. Significant improvements in the emission characteristics of this cathode have been obtained through modification of the chemical composition and morphology of the oxide coating, with the best result thus far coming from the addition of In2O3 and Sc2O3. Whereas the In2O3 produces a finer, more uniform particle structure, the exact chemical state and role of the Sc2O3 in the emission enhancement is unknown. The purpose of this cooperative agreement is to combine the studies of the surface chemistry and electron emission at NASA LeRC of chemically modified oxide coatings with a study of the thermochemistry and crystal structure using X-ray diffraction equipment and expertise at Clark Atlanta University (CAU). The study at CAU is intended to provide the description and understanding of the structure and thermochemistry needed for further improvement and optimization of the modified coatings. A description of the experimental procedure, preliminary X-ray diffraction test results, together with the design of an ultrahigh vacuum chamber necessary for high temperature thermochemistry studies will be presented.

Karikari, E. K.↗

Stationary Crystal Diffraction with a Monochromatic Convergent X-Ray Source and Application for Macromolecular Crystal Data Collection

A diffraction geometry utilizing convergent X-rays from a polycapillary optic incident on a stationary crystal is described. A mathematical simulation of the resulting diffraction pattern (in terms of spot shape, position and intensity) is presented along with preliminary experimental results recorded from a lysozyme crystal. The effective source coverage factor is introduced to bring the reflection intensities onto the same scale. The feasibility of its application to macromolecular crystal data collection is discussed.

Ho, Joseph X.↗

Stationary Crystal Diffraction with a Monochromatic Convergent X-Ray Source and Application for Macromolecular Crystal Data Collection

A diffraction geometry utilizing convergent X-rays from a polycapillary optic incident on a stationary crystal is described. A mathematical simulation of the resulting diffraction pattern (in terms of spot shape, position and intensity) is presented along with preliminary experimental results recorded from a lysozyme crystal. The effective source coverage factor is introduced to bring the reflection intensities onto the same scale. The feasibility of its application to macromolecular crystal data collection is discussed.

Ho, J. X.↗

Measuring In-Plane Displacements with Variable Sensitivity Using Diffractive Optic Interferometry

This paper introduces a method called diffractive optic interferometry (DOI) which allows in-plane displacement components to be measured with variable sensitivity. DOI relies on binary optical elements fabricated as phase-type Dammann gratings which produce multiple diffraction orders of nearly equal intensity. Sensitivity is varied by combining the different wavefronts produced by a conjugate pair of these binary optical elements; a transmission element is used to produce several illumination beams while a reflective element, replicated on the surface of a specimen, provides the reference for the undeformed state. The steps taken to design and fabricate these binary optical elements are described. The specimen grating is characterized, and tested on a disk subjected to diametrical compression. Overall, the results are excellent, with experimental data agreeing to within a few percent of the theoretical predictions.

Shepherd, Robert L.↗

Rectangular Relief Diffraction Gratings for Coherent Lidar Beam Deflection

LIDAR systems require a light transmitting system for sending a laser light pulse into space and a receiving system for collecting the retro-scattered light, separating it from the outgoing beam and analyzing the received signal for calculating wind velocities. Currently, a shuttle manifested coherent LIDAR experiment called SPARCLE (SPAce Readiness Coherent Lidar Experiment) includes a silicon wedge (or prism) in its design in order to deflect the outgoing beam 30 degrees relative to the incident direction. The intent of this paper is to present two optical design approaches that may enable the replacement of the optical wedge component (in future, larger aperture, post-SPARCLE missions) with a surface relief transmission diffraction grating. Such a grating could be etched into a lightweight, flat, fused quartz substrate. The potential advantages of a diffractive beam deflector include reduced weight, reduced power requirements for the driving scanning motor, reduced optical sensitivity to thermal gradients, and increased dynamic stability.

Cole, H. J.↗

Remote X-Ray Diffraction and X-Ray Fluorescence Analysis on Planetary Surfaces

The legacy of planetary X-ray Diffraction (XRD) and X-ray Fluorescence (XRF) began in 1960 when W. Parish proposed an XRD instrument for deployment on the moon. The instrument was built and flight qualified, but the Lunar XRD program was cancelled shortly before the first human landing in 1969. XRF chemical data have been collected in situ by surface landers on Mars (Viking 1 & 2, Pathfinder) and Venus (Venera 13 & 14). These highly successful experiments provide critical constraints on our current understanding of surface processes and planetary evolution. However, the mineralogy, which is more critical to planetary surface science than simple chemical analysis, will remain unknown or will at best be imprecisely constrained until X-ray diffraction (XRD) data are collected. Recent progress in X-ray detector technology allows the consideration of simultaneous XRD (mineralogic analysis) and high-precision XRF (elemental analysis) in systems miniaturized to the point where they can be mounted on fixed landers or small robotic rovers. There is a variety of potential targets for XRD/XRF equipped landers within the solar system, the most compelling of which are the poles of the moon, the southern highlands of Mars and Europa.

Blake, David F.↗

Effect of Stacking Faults on the X-Ray Diffraction Profiles of Beta-SiC Powders

X-ray diffraction patterns or beta-SiC (3C or the cubic polytype or sic) powders often exhibit an additional peak at d = 0.266 nm, high background intensity around the (111) peak, and relative intensities for peaks which differ from those predicted from the crystal structure. Computer simulations were used to show that all these features are due to stacking faults in the powders and not due to the presence of other polytypes in the powders. Such simulations allow diffraction patterns to be generated for different types, frequencies, and spatial distribution or faults. Comparison of the simulation results to the XRD data indicates that the B-SiC particles consist either of heavily faulted clusters distributed irregularly between regions that have only occasional faults or twins, or the powders consist of two types of particles with different populations of faults: those with a high density of faults and those with only twins or occasional faults. Additional information is necessary to determine which description is correct. However, the simulation results can be used to rule out certain fault configurations.

Pujar, Vijay V.↗

Phase Sensitive X-Ray Diffraction Imaging of Defects in Biological Macromolecular Crystals

Characterization of defects and/or disorder in biological macromolecular crystals presents much greater challenges than in conventional small-molecule crystals. The lack of sufficient contrast of defects is often a limiting factor in x-ray diffraction topography of protein crystals. This has seriously hampered efforts to understand mechanisms and origins of formation of imperfections, and the role of defects as essential entities in the bulk of macromolecular crystals. In this report, we employ a phase sensitive x-ray diffraction imaging approach for augmenting the contrast of defects in protein crystals.

Hu, Z. W.↗

High Pressure X-Ray Diffraction Studies on Nanocrystalline Materials

Application of in situ high pressure powder diffraction technique for examination of specific structural properties of nanocrystals based on the experimental data of SiC nanocrystalline powders of 2 to 30 nrn diameter in diameter is presented. Limitations and capabilities of the experimental techniques themselves and methods of diffraction data elaboration applied to nanocrystals with very small dimensions (< 30 nm) are discussed. It is shown that due to the complex structure, constituting a two-phase, core/surface shell system, no unique lattice parameter value and, consequently, no unique compressibility coefficient can satisfactorily describe the behavior of nanocrystalline powders under pressure. We offer a tentative interpretation of the distribution of macro- and micro-strains in nanoparticles of different grain size.

Palosz, B.↗