Search NASA⌕ Search

SEARCH · Search NASA

Results for “disturbance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Application of helium line intensity ratio spectroscopy to xenon plasma in E × B Penning discharge

Here, we propose the application of helium line intensity ratio spectroscopy in a low-pressure (0.3 mTorr) xenon E × B discharge with an electron temperature of ~2 eV and a density of 10 10 –10 11 cm –3 . We successfully identified the helium atom line emissions at 388.9, 447.1, 501.6, 504.8, and 706.5 nm with helium pressures of up to ~20 mTorr. The measured electron temperature, density, and I–V characteristics of the discharge remained almost constant in all helium pressures in the present experiment, indicating the suitability of the helium gas as a diagnostic gas. The results of helium line intensity ratio spectroscopy using the line emissions at 388.9, 447.1, and 504.8 nm showed fair agreement with the Langmuir probe measurement. Considering the trade-off relationship between the disturbance introduced by the helium gas and the signal-to-noise ratio, we conclude that a helium pressure of approximately 4 mTorr (approximately 13 times the partial pressure of xenon) represents the optimal pressure range for the application of the helium line emission intensity ratio method to this xenon plasma. It is found that the use of the line emissions at 501.6 and 706.5 nm result in a significant disturbance in the helium line intensity ratio method due to the radiation trapping effect.

helium line intensity ratio spectroscopy↗

Characterizing manufacturing sector disruptions with targeted mitigation strategies

It has become clear in recent decades that manufacturing supply chains are increasingly vulnerable to disruptions of varying geographical scales and intensities. These disruptions—whether intentional, accidental, or resulting from natural disasters—cause failures and capacity reductions to manufacturing infrastructure, with lasting effects that can cascade throughout the manufacturing network. An overall lack of understanding of solutions to mitigate disturbances has rendered the challenge of reducing manufacturing supply chain vulnerability even more difficult. Additionally, the variability of disruptions and their impacts complicates policy maker and stakeholder efforts to plan for specific disruptive scenarios. It is necessary to comprehend different kinds of disturbances and group them based on stakeholder-provided metrics to support planning processes and modeling efforts that promote adaptable, resilient manufacturing supply chains. This paper reviews existing methods for risk management in manufacturing supply chains and the economic and environmental impacts of disruptions. In addition, we develop a framework using agglomerative hierarchical clustering to classify disruptions using U.S. manufacturing network data between 2000 and 2021 and characteristic metrics defined in the literature. Our review identifies five groups of disruptions and discusses both general mitigation methods and strategies targeting each identified group. Further, we highlight gaps in the literature related to estimating and including environmental costs in disaster preparedness and mitigation planning. We also discuss the lack of easily available metrics to quantify environmental impacts of disruptions and how such metrics could be included into our methodology.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

White-tailed deer responses to acoustic predator cues are contingent upon past land use and contemporary fire regime

Prey can assess the immediate risk of predation by detecting cues of predator presence, and it is expected that prey should invest in costly antipredator behaviors when a cue of predator presence is detected. Features of the habitat in which the cue is detected, such as vegetative concealment, serve as indirect cues of risk and can mediate how prey respond to direct cues of predator presence. Past agricultural land use and contemporary fire regimes are common disturbances that may modify prey perceptions of risk and could, therefore, alter prey responses to direct cues of predator presence. Here we examined whether the overlap of these two disturbances affected white-tailed deer (Odocoileus virginianus) responses to cues of predator presence by measuring deer vigilance and foraging bout duration in response to coyote (Canis latrans) vocalizations across 20 woodlands that varied in past land use and contemporary fire regime. Frequent fire regimes consistently increased deer visibility to predators across both land-use history contexts. Deer exhibited no behavioral response to the predator cue in habitats containing infrequent fire regimes or agricultural legacies. Deer responded to the cue in frequently burned woodlands without agricultural legacies through increased vigilance and time spent at a foraging location. These findings reveal that land-use legacies and contemporary fire regimes can mediate how prey respond to direct cues of risk. They also suggest that prey may balance the uncertainty associated with cues of predation risk with the urgency of responding to a potential attack by being vigilant and remaining in place.

60 APPLIED LIFE SCIENCES↗

The lifetime risk and impact of vitiligo across sociodemographic groups: a UK population-based cohort study

Abstract Background Vitiligo is an autoimmune skin disorder characterized by depigmented patches of skin, which can have significant psychological impacts. Objectives To estimate the lifetime incidence of vitiligo, overall, by ethnicity and across other sociodemographic subgroups, and to investigate the impacts of vitiligo on mental health, work and healthcare utilization. Methods Incident cases of vitiligo were identified in the Optimum Patient Care Database of primary care records in the UK between 1 January 2004 and 31 December 2020. The lifetime incidence of vitiligo was estimated at age 80 years using modified time-to-event models with age as the timescale, overall and stratified by ethnicity, sex and deprivation. Depression, anxiety, sleep disturbance, healthcare utilization and work-related outcomes were assessed in the 2 years after vitiligo diagnosis and compared with matched controls without vitiligo. The study protocol for this retrospective observational study was registered with ClinicalTrials.gov (NCT06097494). Results In total, 9460 adults and children were newly diagnosed with vitiligo during the study period. The overall cumulative lifetime incidence was 0.92% at 80 years of age [95% confidence interval (CI) 0.90–0.94]. Cumulative incidence was similar in female (0.94%, 95% CI 0.92–0.97) and male patients (0.89%, 95% CI 0.86–0.92). There were substantial differences in lifetime incidence across ethnic groups, listed by Office for National Statistics criteria [Asian 3.58% (95% CI 3.38–3.78); Black 2.18% (95% CI 1.85–2.50); Mixed/multiple 2.03% (95% CI 1.58–2.47); Other 1.05% (95% CI 0.94–1.17); and White 0.73% (95% CI 0.71–0.76)]. Compared with matched controls, people with vitiligo had an increased risk of depression [adjusted odds ratio (aOR) 1.08, 95% CI 1.01–1.15]; anxiety (aOR 1.19, 95% CI 1.09–1.30); depression or anxiety (aOR 1.10, 95% CI 1.03–1.17); and sleep disturbance [adjusted hazard ratio (aHR) 1.15, 95% CI 1.02–1.31]. People with vitiligo also had a greater number of primary care encounters (adjusted incidence rate ratio 1.29, 95% CI 1.26–1.32) and a greater risk of time off work (aHR 1.15, 95% CI 1.06–1.24). There was little evidence of disparities in vitiligo-related impacts across ethnic subgroups. Conclusions Clinicians should be aware of the markedly increased incidence of vitiligo in people belonging to Asian, Black, Mixed/multiple and Other groups. The negative impact of vitiligo on mental health, work and healthcare utilization highlights the importance of monitoring people with vitiligo to identify those who need additional support.

Eleftheriadou, Viktoria↗

Taxonomic and functional restoration of tallgrass prairie soil microbial communities in comparison to remnant and agricultural soils

Abstract Restoring ecosystems requires the re-establishment of diverse soil microbial communities that drive critical ecosystem functions. In grasslands, restoration and management require the application of disturbances like fire and grazing. Disturbances can shape microbial taxonomic composition and potentially functional composition as well. We characterized taxonomic and functional gene composition of soil communities using whole genome shotgun metagenomic sequencing to determine how restored soil communities differed from pre-restoration agricultural soils and original remnant soils, how management affects soil microbes, and whether restoration and management affect the number of microbial genes associated with carbohydrate degradation. We found distinct differences in both taxonomic and functional diversity and composition among restored, remnant, and agricultural soils. Remnant soils had low taxonomic and functional richness and diversity, as well as distinct composition, indicating that restoration of agricultural soils does not re-create soil microbial communities that match remnants. Prescribed fire management increased functional diversity, which also was higher in more recently planted restorations. Finally, restored and post-fire soils included high abundances of genes encoding cellulose-degrading enzymes, so restorations and their ongoing management can potentially support functions important in carbon cycling.

Mason, Cayla N. (ORCID:0000000345983824)↗

Noninvasive mid-circuit measurement and reset on atomic qubits

Mid-circuit measurement and reset of subsets of qubits are crucial ingredients of quantum error correction and many quantum information applications. Measurement of atomic qubits is accomplished through resonant fluorescence, which typically disturbs neighboring atoms due to photon scattering. We propose and prototype a scheme for measurement and reset that provides both spatial and spectral isolation by using tightly focused laser beams and narrow atomic transitions. The unique advantage of this scheme is that all operations are applied exclusively to the read-out qubit, with little overhead and negligible disturbance to the other qubits of the same species. In this paper, we pave the way for noninvasive and high-fidelity mid-circuit measurement and demonstrate all key building blocks on a single trapped barium ion.

atomic systems↗

Locating the Source of Forced Oscillations in Transmission Power Grids

A forced oscillation event in power grids refers to a state where malfunctioning or abnormally operating equipment causes persisting periodic disturbances in the system. While power grids are designed to damp most perturbations during standard operations, some of them can excite normal modes of the system and cause significant energy transfers across the system, creating large oscillations thousands of miles away from the source. Localization of the source of such disturbances remains an outstanding challenge due to a limited knowledge of the system parameters outside of the zone of responsibility of system operators. Here, we propose a new method for locating the source of forced oscillations that addresses this challenge by performing a simultaneous dynamic model identification using a principled maximum likelihood approach. We illustrate the validity of the algorithm on a variety of examples where forcing leads to resonance conditions in the system dynamics. Our results establish that an accurate knowledge of system parameters is not required for a successful inference of the source and frequency of a forced oscillation. We anticipate that our method will find a broader application in general dynamical systems that can be well described by their linearized dynamics over short periods of time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A New Proposal Generalized Predictive Control Algorithm With Polynomial Reference Tracking Applied for Sodium Fast Reactors

This paper proposes a generalized predictive control (GPC) with constraints and orthonormal Laguerre functions using the simplified model of the primary system (reactor core and intermediate heat exchanger (IHX)) of a prototypical sodium fast reactor (SFR). This paper develops a multiple-input multiple-output (MIMO) GPC with input constraints able to track polynomial references of any degree applied in coolant temperature difference across the core and fractional power. The manipulated variables of the GPC-SFR are the reactivity and the sodium flow rate of the primary and secondary pipes. Moreover, orthonormal Laguerre functions and step down condition number techniques were also applied to avoid the numerical ill-conditioning issue in quadratic programming of large systems. Thus, a GPC type-2 was designed to control fractional power, coolant temperature difference across the core and sodium tank temperature of the SFR primary system when temperature references change according to a linear ramp after reaching their steady-state operation, sustaining 100% power operation on the reactor. In order to analyze the load tracking capability of the GPC-SFR type-2, the load following from 100% fractional power (FP) to 60% FP at 0.8% FP/min rate is simulated. Constraints on the rate of coolant temperature difference across the core and reactivity were applied for the design safety. For comparison criteria, this paper compares the GPC-SFR type-2 with the GPC-SFR type-1, i.e., standard model predictive control (MPC), to verify the viability and superior performance of the proposal regarding: (a) ramp-tracking capability of temperature and load; (b) the rejections of a reactivity disturbance of -1 cent and a secondary sodium inlet temperature disturbance of +10°F; and (c) a simulation with uncertainty in reactor design. The simulations show that the GPC-SFR type-2 overcome the GPC-SFR type-1 robustness and performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Observer-Based Nonlinear Control Scheme to Reduce Oscillations and Zero Crossing in Skid-Steer Vehicles

Motion sickness is a common condition experienced by drivers of skid-steer vehicles, primarily caused by zero crossing and oscillations in undamped systems. This study proposes an observer-based nonlinear control scheme to reduce transient oscillations and zero-crossing phenomena in skid-steer vehicles, thereby potentially alleviating motion sickness. Reducing transient oscillations and zero crossing in the transient response may alleviate motion sickness. A nonlinear damping controller is designed to improve transient response by reducing oscillations and zero-crossing. To design the controller, a reduced-order kinematic model based on coordinate transformation is developed. This transformation not only converts the system modeling into a controllable form but also enhances control performance. Modeling error is addressed by considering the distance between the center of the vehicle and the sensor location. Despite these improvements, model uncertainties and external disturbances remain, which may degrade control performance. To ensure robustness and estimate such disturbances, a high-order sliding mode observer (HOSMO) is incorporated. The effectiveness of the proposed method is validated through MATLAB/Simulink and TruckMaker simulations. From the simulation results, it was shown that the proposed method reduced the mean squared error of the tracking error to within 10 % compared to the state feedback controller with the HOSMO.

Seo, Jiwon [Chung-Ang University, Seoul (Korea, Re↗

Enhancing the Survivability of Power Systems With Grid-Edge DERs Against DoS Attacks

Power system survivability, defined as the ability of a system to maintain steady-state functionality under varying operational conditions, reflects its resilience against disturbances. While existing research primarily focuses on physical-layer disturbances, the increasing prevalence of grid-edge DERs, which are primarily used for integrating renewable energy, has significantly expanded the cyber attack surface. As a result, operational disruptions caused by cyber threats are posing significant challenges to system survivability and cannot be overlooked. To fill this gap, we redefine system survivability to incorporate the cyber layer’s status and propose a Distributionally Robust Optimization (DRO) approach to enhance power system survivability against potential cyber-physical threats. In this paper, we first analyze the operational guidelines of systems with a high penetration of DERs under various cyber network conditions and redefine survivability in this context. Next, we focus on the most common cyber threat, Denial-of-Service (DoS) attacks, and develop a corresponding attack model. This model allows for the creation of a kernel-based ambiguity set that captures attack uncertainties using historical data. Finally, we transform the proposed DRO model as a tractable optimization problem, with its solution providing an optimal cyber redundancy plan to enhance system survivability in DoS attack scenarios. Simulation results on the IEEE 13-node and 123-node test feeders demonstrate the effectiveness of our proposed model in improving system survivability. This model can also be expanded to include other types of common attacks and serve as a comprehensive planning tool to improve overall cyber physical survival of the system.

cybersecurity↗

Towards Robustness Guarantees for Feedback-Based Optimization

Feedback-based online optimization algorithms have gained traction in recent years because of their simple implementation, their ability to reject disturbances in real time, and their increased robustness to model mismatch. While the robustness properties have been observed both in simulation and experimental results, the theoretical analysis in the literature is mostly limited to nominal conditions. In this work, we propose a framework to systematically assess the robust stability of feedback-based online optimization algorithms. We leverage tools from monotone operator theory, variational inequalities and classical robust control to obtain tractable numerical tests that guarantee robust convergence properties of online algorithms in feedback with a physical system, even in the presence of disturbances and model uncertainty. The results are illustrated via an academic example and a case study of a power distribution system.

approximation algorithms↗

Synchronverter-based Control of Multi-Port Autonomous Reconfigurable Solar Plants (MARS)

Control of integrated photovoltaic (PV) plants with energy storage systems (ESSs) has become an important research and development topic in recent times. In this context, a Multi-port Autonomous Reconfigurable Solar (MARS) plant that integrates PV and ESS to alternating current transmission grid and high-voltage direct current (HVdc) link is studied in this paper. With penetration of power electronic based resources in the grid, the grid’s capability to recover from frequency or voltage disturbances are reduced. Therefore, one of the vital objectives of any new grid integrated power electronic resource is to provide advanced control functions like voltage and frequency support to the grid during disturbances. In this research work, a detailed implementation of a synchronverter-based control algorithm of MARS is presented. The proposed control algorithm and the MARS control architecture are evaluated through simulations on PSCAD/EMTDC simulation platform to showcase the performance in different operating conditions. In addition, they are evaluated in Opal-RT offline simulation models which can also be used to perform control-hardware-in-the-loop (cHIL) tests.

Marthi, Phani Ratna Vanamali↗

A Single-Stage Multilevel AC-DC Bidirectional Converter With Natural Grid Harmonic Elimination

Generally, AC-DC converters have an AC-DC stage followed by a DC-DC stage. In these two stage approaches, the AC-DC stage is hard-switched, whereas the DC-DC stage is soft-switched. Therefore, the devices in the AC-DC stage can be switched only at tens of kHz to avoid excessive switching losses, thus limiting the bandwidth of the current control loop. Hence, the control of these converters with distorted grid voltages requires multiple harmonic compensation loops or other complex control algorithms in order for the grid currents to comply with IEEE standards. By integrating both the stages, the devices in the AC-DC stage can also be soft-switched, thus facilitating higher switching frequency, and thereby higher current control bandwidth. This paper proposes an integrated multilevel bidirectional AC-DC converter with improved control bandwidth and disturbance rejection. It is shown experimentally that the high bandwidth current control loop of the converter can reject grid harmonic current disturbances, without the need for any compensation loops or complex control techniques, and comply with IEEE standards.

30 DIRECT ENERGY CONVERSION↗

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting↗

Rapid Event Detection via Synchro-Waveform Based Temporal Attention Network in Distributed Grid

Compared with the information collected from phasor measurement units, synchro-waveforms contain high-fidelity disturbances of the grid, which can be a granular and authentic representation of measurements in the modern power system. However, the dynamic changing morphology makes it challenging to effectively capture various disturbance information from the synchro-waveforms. To tackle this issue, this paper proposes a Synchro-waveform based Temporal Attention (STA) network to achieve rapid event detection. First, a multi-scenario distributed model with renewable integration is established to generate synchro-waveforms under various uncertainties. Then, three typical temporal features are extracted directly from the synchro-waveform measurements. Additionally, the lightweight STA network is deployed to identify the most common event types in renewable energy systems via the self-attention based vision transformer module. The results from simulated experiments demonstrate that the proposed approach can achieve rapid and real-time detection within 0.81 ms and over 96.27 % accuracy.

Dong, Yuqing [University of Tennessee (UT)]↗

First Demonstration of Vertical 2T-nC FeRAM Hybrid Cell and its Scalability for High-Density 3D Ferroelectric Capacitor Memory

In this article, we perform a comprehensive experimental and modeling study into the scaling of vertical 2T-nC ferroelectric random-access memory (FeRAM) hybrid cell to demonstrate a high performance and high-density 3D capacitor memory. We demonstrate: i) first time successful integration of the vertical 2T-3C FeRAM cell by stacking the vertical metal-ferroelectricmetal (MFM) stack on top of Si CMOS transistors; ii) successful experimental operation of the memory cell, including the quasi-nondestructive read out (QNRO) of the polarization without write back after 106 read cycles; iii) the write bit line (WBL) heavily screens the coupling between neighboring strings, making it a minor concern; V ) aggressive stacking of the WBLs, i.e., number of MFMs in a string, could facilitate the self-boosting during write operation due to ferroelectric linear capacitance (CFE), which allows self-boosted inhibition for Vw/2 scheme and worsens the Vw/3 scheme as disturb increases to intolerable 2Vw/3; v) aggressive horizontal scaling significantly increases the read disturb to cells on neighboring planes due to capacitance between two WBLs (Cz).

42 ENGINEERING↗

Preparing an on-Demand Cloud Processing Workflow for NISAR Ecosystems Science Products

In preparation for the NISAR launch and data collection in 2024, the NISAR Project Science Team is building workflows for each Science Team discipline (Ecosystems, Cryosphere, and Solid Earth). This abstract focuses on the Ecosystem disciplines and the development of on-demand cloud-processing workflows for wetlands inundation, forest biomass, agricultural active crop area, and forest disturbance. The workflow simulates NISAR data using UAVSAR or ALOS-2 Single Look Complex data, which are processed to Level 2 geocoded polarimetric covariance matrix products using InSAR Scientific Computing Environment 3.0 software and to Level 3 science products using the Algorithm Theoretical Basis Documents. In this presentation, we describe these workflows and efforts to improve efficiency and data accessibility by using a cloud processing system. We present preliminary sample products from each Ecosystem discipline: inundation, forest biomass, crop area, and forest disturbance.

Christensen, Alexandra↗

Improving Frequency Stability and Minimizing Load Shedding Events by Adopting Grid-Scale Energy Storage with Grid Forming Inverters

The upward adoption trend of renewable generation not only means cleaner energy integrated into modern power grids, but also that most new generation sources are based on front-end inverter bridges, used as interfaces to most wind generation and all the solar PV. It is well known that due to their power electronics-based construction rather than rotational shafts, these sources do not provide inertia inherently, nor substantial amounts of short-circuit currents. However, stable energy such as what can be stored in energy storage systems, although interfaced via inverters, can be controlled to respond to system disturbances in a manner that emulates inertial behavior. This paper focuses on the application of such energy storage systems to augment inertia in the island of Puerto Rico. To do so, a user defined inverter model that contains grid forming capabilities and fast frequency response is modeled and integrated into the real transmission system in power flow and dynamics software. Energy storage is then connected to two selected areas so that it not only provides frequency regulation to avoid widespread load shedding events, but also other tangible benefits. The simulated cases suggest that even relatively small energy storage systems can avert load shedding events if adequately placed in the transmission network.

Grid-forming inverters, IBR, Inertia↗