SEARCH · Search NASA
Results for “nuclear analysis”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A Preliminary Model for Spacecraft Propulsion Performance Analysis Based on Nuclear Gain and Subsystem Mass-Power Balances
A preliminary model for spacecraft propulsion performance analysis based on nuclear gain and subsystem mass-power balances are presented in viewgraph form. For very fast missions with straight-line trajectories, it has been shown that mission trip time is proportional to the cube root of alpha. Analysis of spacecraft power systems via a power balance and examination of gain vs. mass-power ratio has shown: 1) A minimum gain is needed to have enough power for thruster and driver operation; and 2) Increases in gain result in decreases in overall mass-power ratio, which in turn leads to greater achievable accelerations. However, subsystem mass-power ratios and efficiencies are crucial: less efficient values for these can partially offset the effect of nuclear gain. Therefore, it is of interest to monitor the progress of gain-limited subsystem technologies and it is also possible that power-limited systems with sufficiently low alpha may be competitive for such ambitious missions. Topics include Space flight requirements; Spacecraft energy gain; Control theory for performance; Mission assumptions; Round trips: Time and distance; Trip times; Vehicle acceleration; and Minimizing trip times.
High-Resolution Fast-Neutron Spectrometry for Arms Control and Treaty Verification
Many nondestructive nuclear analysis techniques have been developed to support the measurement needs of arms control and treaty verification, including gross photon and neutron counting, low- and high-resolution gamma spectrometry, time-correlated neutron measurements, and photon and neutron imaging. One notable measurement technique that has not been extensively studied to date for these applications is high-resolution fast-neutron spectrometry (HRFNS). Applied for arms control and treaty verification, HRFNS has the potential to serve as a complimentary measurement approach to these other techniques by providing a means to either qualitatively or quantitatively determine the composition and thickness of non-nuclear materials surrounding neutron-emitting materials. The technique uses the normally-occurring neutrons present in arms control and treaty verification objects of interest as an internal source of neutrons for performing active-interrogation transmission measurements. Most low-Z nuclei of interest for arms control and treaty verification, including 9Be, 12C, 14N, and 16O, possess fast-neutron resonance features in their absorption cross sections in the 0.5- to 5-MeV energy range. Measuring the selective removal of source neutrons over this energy range, assuming for example a fission-spectrum starting distribution, may be used to estimate the stoichiometric composition of intervening materials between the neutron source and detector. At a simpler level, determination of the emitted fast-neutron spectrum may be used for fingerprinting 'known' assemblies for later use in template-matching tests. As with photon spectrometry, automated analysis of fast-neutron spectra may be performed to support decision making and reporting systems protected behind information barriers. This paper will report recent work at Idaho National Laboratory to explore the feasibility of using HRFNS for arms control and treaty verification applications, including simulations and experiments, using fission-spectrum neutron sources to assess neutron transmission through composite low-Z attenuators.
Inspection of Dry Storage Casks Using PGAA and NAA Techniques
In this effort, an assessment of a chloride detection method is performed for inspecting the surfaces of dry cask storage system (DCSS) canisters, with focus on the implementation of a non-destructive nuclear analysis and methodology. Some DCSS canisters (especially those located in coastal environments) will be exposed to marine environments, which can cause atmospheric stress corrosion cracking (SCC). Chloride deposits on canister surfaces provide the corrosive environment necessary for atmospheric SCC with the residual stresses and materials properties conditions. The most susceptible regions on the canister surface are the weld areas, or where cold work has been performed, and may provide the necessary driving force for crack growth. The heat-affected zones (HAZs) near welds are also potentially susceptible to atmospheric SCC due to sensitization of the material caused by chromium depletion during the welding process. Information collected from the field and from laboratory studies has not been able to rule out the possibility of atmospheric chloride induced stress corrosion cracking (CISCC), although no occurrences of atmospheric SCC in DCSS canisters have been detected to-date. A number of researchers have demonstrated that localized corrosion can take place under such situations on materials commonly used for interim storage containers, including 304SS (Cook et al. 2010; Shirai et al. 2011) and 316SS (Tani et al. 2009). In this summary, the preliminary results of a neutron activation analysis (NAA) and prompt gamma activation analysis (PGAA) are performed using MCNP6, a highly sophisticated, multi-particle Monte Carlo simulation code (with the employment of the high performance computing system at the Idaho National Laboratory), and confirm the feasibility of using PGAA and NAA as an environmental inspection methodology for detection and monitoring of small quantities of chlorine on canister surfaces. The specific signature of gamma rays due reactions of sea salt constituents are documented and summarized in this paper. The environmental constituent for passive oxide film breaching is chlorine, which can cause pitting initiation and incubation time that may lead to cracking in stainless steel. Therefore, an assessment of chloride presence at a canister surface is essential before moving to other nondestructive analysis (NDA) methods for detection of pitting and cracking. Two nonlinear acoustic techniques will also be used in our integrated research project (IRP) research study that proves to be useful in the detection of SCC: nonlinear resonant ultrasound spectroscopy (NRUS), and time revisited elastic nonlinear diagnostic (TREND). These two techniques are complementary to marine atmospheric detection techniques. In this presentation only PGAA and NAA are described in detail. (authors)
Nuclear Energy Knowledge and Validation Center (NEKVaC) Needs Workshop Summary Report
The Department of Energy (DOE) has made significant progress developing simulation tools to predict the behavior of nuclear systems with greater accuracy and of increasing our capability to predict the behavior of these systems outside of the standard range of applications. These analytical tools require a more complex array of validation tests to accurately simulate the physics and multiple length and time scales. Results from modern simulations will allow experiment designers to narrow the range of conditions needed to bound system behavior and to optimize the deployment of instrumentation to limit the breadth and cost of the campaign. Modern validation, verification and uncertainty quantification (VVUQ) techniques enable analysts to extract information from experiments in a systematic manner and provide the users with a quantified uncertainty estimate. Unfortunately, the capability to perform experiments that would enable taking full advantage of the formalisms of these modern codes has progressed relatively little (with some notable exceptions in fuels and thermal-hydraulics); the majority of the experimental data available today is the "historic" data accumulated over the last decades of nuclear systems R&D. A validated code-model is a tool for users. An unvalidated code-model is useful for code developers to gain understanding, publish research results, attract funding, etc. As nuclear analysis codes have become more sophisticated, so have the measurement and validation methods and the challenges that confront them. A successful yet cost-effective validation effort requires expertise possessed only by a few, resources possessed only by the well-capitalized (or a willing collective), and a clear, well-defined objective (validating a code that is developed to satisfy the need(s) of an actual user). To that end, the Idaho National Laboratory established the Nuclear Energy Knowledge and Validation Center to address the challenges of modern code validation and to manage the knowledge from past, current, and future experimental campaigns. By pulling together the best minds involved in code development, experiment design, and validation to establish and disseminate best practices and new techniques, the Nuclear Energy Knowledge and Validation Center (NEKVaC or the ‘Center’) will be a resource for industry, DOE Programs, and academia validation efforts.
AMPX: A Modern cross section processing system for generating nuclear data libraries - 14619
Nuclear data libraries are essential for nuclear analysis code systems like SCALE. AMPX has been continuously developed since the early 1970's and is used to generate these data libraries for SCALE. Recently, Oak Ridge National Laboratory (ORNL) initiated a major modernization effort to position AMPX for continued development and deployment on modern computing platforms. An important step toward modernization has been to merge AMPX under the SCALE continuous integration (CI) development framework. As a result, AMPX is now developed under the SCALE software quality assurance plan, providing increased confidence in the quality of data libraries developed and deployed by AMPX. This merge allowed us to develop novel methods to generate self-shielding factors that combine SCALE's resonance self-shielding capabilities with the AMPX library-generation capabilities. AMPX processes Evaluated Nuclear Data Format (ENDF/B) files. The ENDF community is working to develop a more modern format that will replace the existing ENDF/B format. Due to strict space and memory requirements when AMPX was first developed, the original AMPX processing and reading of ENDF data were tightly integrated. On newer computer systems, this is no longer necessary. Now there is a separation between reading and processing which allows for simultaneous support of current and new ENDF formats. As a result, AMPX is positioned to adopt any new ENDF format when available. For end users, the modernization effort has resulted in improved processing capabilities for generating nuclear data libraries. The objective of the paper is to document the latest AMPX cross-section processing capabilities and provide the current status of the AMPX modernization effort. (authors)
Rapid extraction and assay of uranium from environmental surface samples
Not Available
Frequency spectrum analysis code for nuclear noise based on improved wavelet algorithm - 337
The core of the narrow flow channel generally faced the problem of local bubble boiling with the temperature rise of the nuclear fuel element, it is necessary and meaningful to answer and deal with the problem on the technical level. Reactor noise analysis begins with the study of the physical characteristics of the core, after nearly 30 years of research and development it has become a powerful tool in the auxiliary monitoring of the power reactor operating. By using this noise frequency spectrum analysis technology, the reactor dynamic parameter such as prompt neutron decay constant can be measured. Also, through such system, the frequency characteristics of reactor can be real-time monitored, which is helpful for safety operation and fault diagnosis. Spectrum analysis technology in the Fourier analysis era is now barely available, the reason is that the local spectral characteristics of this technology are not obvious, but this defect can be greatly improved by wavelet analysis technique, however, the traditional wavelet analysis will introduce the problem of spectral confusion. To solve the problem, based on the improved wavelet algorithm, frequency spectrum analysis code for nuclear noise is developed,from the perspective of fine spectral analysis, the local boiling accident of the coolant can be prejudged and avoid. Based on the analysis and test of experimental data,The results show that the calculation ability of the code is in accordance with the expected, it can be applied in the operation of research reactor. (authors)
Structural and Functional Analysis of mRNA Export Regulation by the Nuclear Pore Complex
Explore the source record for details and available documents.
IJS procedure for RELAP5 to TRACE input model conversion using SNAP
The TRAC/RELAP Advanced Computational Engine (TRACE) advanced, best-estimate reactor systems code developed by the U.S. Nuclear Regulatory Commission comes with a graphical user interface called Symbolic Nuclear Analysis Package (SNAP). Much of efforts have been done in the past to develop the RELAP5 input decks. The purpose of this study is to demonstrate the Institut 'Josef Stefan' (IJS) conversion procedure from RELAP5 to TRACE input model of BETHSY facility. The IJS conversion procedure consists of eleven steps and is based on the use of SNAP. For calculations of the selected BETHSY 6.2TC test the RELAP5/MOD3.3 Patch 4 and TRACE V5.0 Patch 1 were used. The selected BETHSY 6.2TC test was 15.24 cm equivalent diameter horizontal cold leg break in the reference pressurized water reactor without high pressure and low pressure safety injection. The application of the IJS procedure for conversion of BETHSY input model showed that it is important to perform the steps in proper sequence. The overall calculated results obtained with TRACE using the converted RELAP5 model were close to experimental data and comparable to RELAP5/MOD3.3 calculations. Therefore it can be concluded, that proposed IJS conversion procedure was successfully demonstrated on the BETHSY integral test facility input model. (authors)
How to reduce Shutdown Dose Rates in ITER Diagnostics Equatorial Ports
The ITER vacuum vessel presents 54 access ports, arranged in three levels, where port plugs are inserted hosting different types of systems: test blanket modules, antennas, vacuum pumps, neutral beam injectors and diagnostics. At the equatorial level, nine out of the eighteen access ports present diagnostics port plugs, in which the diagnostics systems are deployed into three DSMs (Diagnostics Shield Modules). The DSMs, being a major constituent in volume of the port plugs, must help to fulfill the design target of Shutdown Dose Rates (SDDR) corresponding to 100 μSv.h{sup -1} after 10{sup 6} s of cooling time for planned in-situ maintenance operations in the port interspace. Additionally, the DSMs are largely responsible for the port plug drained weight limit of 45 T, which imposes limitations to the shielding technology. Up to now, all the proposed DSM designs combine differently stainless steel, water and/or B{sub 4}C as shielding to accommodate a maximum of 1.1 m{sup 3} of DSM bulk shield, contained into a L 1845 x W 518 x H 2011 mm stainless steel box weighting 5.8 T for each DSM. These proposals show insufficient shielding properties with respect to SDDR, while none of them satisfies currently the weight limit. However, during 2016, a new DSM concept has been developed, named 'modular DSM', with significant engineering advances and changes. The DSM length has been increased by 500 mm, up to 2345 mm. The SS box has been reduced to the minimum structure required, presenting the same weight while being larger and hosting a larger volume of bulk shielding inside. Thus, the volume of bulk shielding has been enlarged up to 1.5 m{sup 3} per DSM. The shielding technology is based on B{sub 4}C bricks deployed in SS trays that are attached to the vertical plates. This results in a bulk shielding made of 65% of B{sub 4}C, 10% SS and 25% void, with effective density of 2.4 g.cm{sup -3}. In summary, the modular DSM, without a weight increase, hosts extra 0.5 m3 of bulk shielding along an additional 500 mm of length, to be used with a light but highly neutron absorber, what allows fitting the weight limit of 45 T for the port plug once drained. From now, the non-modular DSMs will be referred as 'short DSMs'. The modular DSM's advantages with respect to the short DSM versions have shown that the DSMs design can be improved in generic approach, i.e. when the penetrations of the systems are not taken into consideration. A mention apart is required when port specific penetrations are considered. Provided that they will be an important radiation transmission path, their presence could significantly diminish the improvement. To clarify this issue, in this work we have carried out a nuclear analysis of the ITER equatorial port no. 11 integration considering the modular DSM. It is a first plasma port hosting the following 6 major diagnostics systems: Neutral Particle Analyzer (NPA), H-α monitor, Low Field Side (LFS) reflectometry, Visible - Ultraviolet divertor (VUV div), Visible - Ultraviolet core survey (VUV CS) and X-rays Crystal System (XRCS). For the baseline case, a SDDR matrix has been derived assigning responsibilities to the different EP no. 11 individual systems in terms of neutron flux transmission through them, and the related activation due to that neutron flux (activation of itself, but also of the rest of systems taken one by one). Different EP no. 11 configurations have been studied in addition to the baseline case. For example, the backfill of the port plug penetrations to protect all the empty space not required for systems sight. Another issue is the determination of the role of the Co impurity content minimization from 0.05 wt.% to 0.03 wt.% recently proposed. In this summary, only some results related to the baseline are given.
An Extremely Stable, Highly Soluble Monosubstituted Anthraquinone for Aqueous Redox Flow Batteries
An extremely stable, energy-dense (53.6 Ah L –1 , 2 M transferrable electrons), low crossover (permeability of <1 × 10 –13 cm 2 s –1 using Nafion 212 (Nafion is a trademark polymer from DuPont)), and potentially inexpensive anthraquinone with 2-2-propionate ether anthraquinone structure (abbreviated 2-2PEAQ) is synthesized and extensively evaluated under practically relevant conditions for use in the negolyte of an aqueous redox flow battery. 2-2PEAQ shows a high stability with a fade rate of 0.03–0.05% per day at different applied current densities, cut-off voltage windows, and concentrations (0.1 and 1.0 M ) in both a full cell paired with a ferro/ferricyanide posolyte as well as a symmetric cell. 2-2PEAQ is further shown to have extreme long-term stability, losing only ≈0.01% per day when an electrochemical rejuvenation strategy is employed. From post-mortem analysis (nuclear magnetic resonance (NMR), liquid chromatography–mass spectrometry (LC-MS), and cyclic voltammetry (CV)) two degradation mechanisms are deduced: side chain loss and anthrone formation. 2-2PEAQ with the ether linkages attached on carbons non-adjacent to the central ring is found to have three times lower fade rate compared to its isomer with ether linkages on the carbon adjacent to the central quinone ring. Here, the present study introduces a viable negolyte candidate for grid-scale aqueous organic redox flow batteries.
Evaluation of anti-allergic properties of caffeic acid phenethyl ester in a murine model of systemic anaphylaxis
Caffeic acid phenethyl ester (CAPE) is an active component of honeybee propolis extracts. It has several positive effects, including anti-inflammatory, anti-oxidation, anti-cancer, anti-bacterial, anti-viral, anti-fungal, and immunomodulatory effects. In particular, the suppressive effect of NF-{kappa}B may disrupt a component of allergic induction. The principal objective of this experimental study was to evaluate the effects of CAPE on the active systemic anaphylaxis induced by ovalbumin (OVA) challenge in mice. Mice were intraperitoneally sensitized and intravenously challenged with OVA. Histopathological analysis, nuclear factor (NF)-{kappa}B activation, and the plasma levels of histamine and total IgE after allergen challenge were evaluated. After challenges, all of the sham-treated mice developed anaphylactic symptoms, increased plasma levels of histamine and OVA-specific IgE, marked vascular leakage, NF-{kappa}B activation, platelet-activating factor (PAF) production, and histological changes including pulmonary edema and hemorrhage in the renal medullae within 20 min. By way of contrast, a reduction in the plasma levels of histamine and OVA-specific IgE and an inhibition of NF-{kappa}B activation and PAF release were observed in the CAPE-treated mice. In addition, a significant prevention of hemoconcentration and OVA-induced pathological changes were noted. These results indicate that CAPE demonstrates an anti-allergic effect, which may be the result of its protective effects against IgE-mediated allergy.
Improved Chemical and Colloidal Stability of Gold Nanoparticles through Dendron Capping
Nanoparticle (NP) stability is imperative for commercialization of nanotechnology. In this study, we compare the stability of Au NPs with surfaces functionalized with oleylamine, dodecanethiol, and two dendritic ligands of different generations. Dendrimer ligands provide a significant increase in the chemical stability of Au NPs when analyzed by cyanide-induced NP decomposition as well as an investigation into their colloidal stability at ambient conditions. These results were supported by absorption measurements, transmission electron microscopy, thermogravimetric analysis, nuclear magnetic resonance, and small-angle transmission X-ray scattering and show that dendrimers play a key role in improving the chemical and colloidal stability of NPs.
Spectroscopy of element 115 decay chains
A high-resolution a, X-ray and -ray coincidence spectroscopy experiment was conducted at the GSI Helmholtzzentrum fu r Schwerionenforschung. Thirty correlated a-decay chains were detected following the fusion-evaporation reaction 48Ca + 243Am. The observations are consistent with previous assignments of similar decay chains to originate from element Z = 115. The data includes first candidates of fingerprinting the decay step Mt --> Bh with characteristic X rays. For the first time, precise spectroscopy allows the derivation of excitation schemes of isotopes along the decay chains starting with elements Z > 112. Comprehensive Monte-Carlo simulations accompany the data analysis. Nuclear structure models provide a first level interpretation.
CERT TST November 2016 Visit Summary
The dozen plus presentations covered the span of the Center’s activities, including experimental progress, simulations of the experiments (both for calibration and validation), UQ analysis, nuclear data impacts, status of simulation codes, methods development, computational science progress, and plans for upcoming priorities. All three institutions comprising the Center (Texas A&M, University of Colorado Boulder, and Simon Fraser University) were represented. Center-supported students not only gave two of the oral presentations, but also highlighted their research in a number of excellent posters.
TPC Test-stands: An Overview & Future Prospects
The DUNE near detector design in Phase II will include a magnetized high-pressure gaseous-argon TPC (HPgTPC) surrounded by a calorimeter, called ND-GAr. ND-GAr is designed to provide fine-grained tracking, and due to its low detection threshold, it will be able to constrain one of the least-understood uncertainties for oscillation analysis: nuclear effects in argon at the neutrino interaction vertex. This talk will provide an overview of and an outlook about the ongoing R&D efforts in the context of the existing test stands that are evaluating the various readout system options for DUNE ND-GAr.
High-Pressure Gaseous Argon TPC for the DUNE Near Detector
The DUNE Near Detector design consists of multiple components, each designed to produce complementary constraints on flux and neutrino interaction systematic uncertainties for the oscillation analyses. One of these subdetectors is a magnetized high-pressure gaseous-argon TPC (HPgTPC), which will provide fine-grained tracking in a low-density detector, using the same target nucleus as the DUNE far detector. With its low momentum threshold for particle detection, the HPgTPC will be able to constrain one of the most crucial - and least-well understood - uncertainties for the oscillation analysis: nuclear effects in neutrino-argon interactions. These proceedings describe the current design, physics goals, and projected performance of the HPgTPC, as well as the ongoing R&D work at Fermilab, in which a test-stand TPC is being built and will be operated at up to 10 atm pressure.