Search NASA⌕ Search

SEARCH · Search NASA

Results for “occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

THE GALAXY-HALO/SUBHALO CONNECTION: MASS RELATIONS AND IMPLICATIONS FOR SOME SATELLITE OCCUPATIONAL DISTRIBUTIONS

We infer the local stellar-to-halo/subhalo mass relations (MRs) for central and satellite galaxies separately. Our statistical method is an extension of the abundance matching, halo occupation distribution, and conditional stellar mass function formalisms. We constrain the model using several combinations of observational data, consisting of the total galaxy stellar mass function (GSMF), its decomposition into centrals and satellites, and the projected two-point correlation functions (2PCFs) measured in different stellar mass (M{sub *}) bins. In addition, we use the {Lambda}CDM halo and subhalo mass functions. The differences among the resulting MRs are within the model-fit uncertainties (which are very small, smaller than the intrinsic scatter between galaxy and halo mass), no matter what combination of data are used. This shows that matching abundances or occupational numbers is equivalent, and that the GSMFs and 2PCFs are tightly connected. We also constrain the values of the intrinsic scatter around the central-halo (CH) and satellite-subhalo (SS) MRs assuming them to be constant: {sigma}{sub c} = 0.168 {+-} 0.051 dex and {sigma}{sub s} = 0.172 {+-} 0.057 dex, respectively. The CH and SS MRs are actually different, in particular when we take the subhalo mass at the present-day epoch instead of at their accretion time. When using the MRs for studying the satellite population (e.g., in the Milky Way, MW), the SS MR should be chosen instead of the average one. Our model allows one to calculate several population statistics. We find that the central galaxy M{sub *} is not on average within the mass distribution of the most massive satellite, even for cluster-sized halos, i.e., centrals are not a mere realization of the high end of the satellite mass function; however for >3 Multiplication-Sign 10{sup 13} M{sub Sun} halos, {approx}15% of centrals could be. We also find that the probabilities of MW-sized halos of having N Magellanic Cloud (MC) sized satellites agree well with observational measures; for a halo mass of 2 Multiplication-Sign 10{sup 12} M{sub Sun }, the probability to have two MCs is 5.4%, but if we exclude those systems with satellites larger than the MCs, then the probability decreases to <2.2%.

79 ASTRONOMY AND ASTROPHYSICS↗

Seasonal changes in occupancy and activity patterns in native Collared Peccary and non-native wild pig and Common Warthog in southern Texas, the United States

Abstract Southern Texas, USA, is home to native collared peccaries (Dicotyles tajacu) and introduced populations of invasive wild pigs (generally Sus scrofa × domesticus hybrids) and non-native African warthogs (Phacochoerus africanus). Although these ecologically similar mammals co-occur in this region, the potential impacts of invasive suids on collared peccaries are poorly understood. We examined co-occupancy and activity pattern overlap of collared peccaries, wild pigs, and warthogs across 3 seasons (fall, winter, and spring) using remote camera data collected from Chaparral Wildlife Management Area, Cotulla, Texas (November 2020 to June 2021). Using activity pattern analyses and single and 2-species occupancy models incorporating habitat and climate characteristics, we found evidence of extensive spatial overlap between all species pairs and varying degrees of temporal overlap depending on species pairs and season. Collared peccaries and wild pigs displayed moderate temporal overlap across all seasons. Collared peccaries appeared to alter fall activity in the presence of wild pigs to be active earlier in the morning and less active during the day. Collared peccaries and warthogs had low-to-moderate temporal overlap (low in fall, winter; moderate in spring). Wild pigs and warthogs had low temporal overlap (fall, spring) and wild pigs appeared to alter activity in the presence of warthogs (fall), becoming less active during the day during peak warthog activity. Overall, our results suggest that peccary, wild pig, and warthog interactions and activity are dynamic and vary seasonally according to the ecology and preferred environmental conditions of each species. Given the potential for interspecific competition and disease transmission with Collared Peccary and other native wildlife, resource partitioning between wild pigs and warthogs needs to be further examined to aid in effective management strategies.

Kupferman, Caitlin A. (ORCID:0009000953554860)↗

Comparison of Different Variants of the U.S. Army Occupational Physical Assessment Test

The U.S. Army Occupational Physical Assessment Test (OPAT) is a pre-enlistment physical employment screening assessment developed to place recruits and soldiers into Military Occupational Specialties (MOSs) based on their physical capabilities in order to optimize performance and limit injury. The OPAT consists of the seated power throw (SPT), strength deadlift (SDL), standing long jump, and interval aerobic run. During the scientific validation of the OPAT, two variants of the SPT and two variants of the SDL were used. Although the OPAT was validated using both variants for each test, U.S. Army scientists and policymakers have received queries regarding how these variants compare to each other. Therefore, the purpose of this study was to compare different variants of the SPT and SDL. Thirty-two participants (14 male and 18 female) between the ages of 18 and 42 years visited the laboratory on one occasion and performed two variants of the SPT (seated on the ground [the current OPAT standard] versus seated in a chair with a 35 cm seat height) and two variants of the SDL (using a hex-bar [the current OPAT standard] versus using paired dumbbells). Testing order for the different variants was randomized. The protocol was approved by the U.S. Army Medical Research and Development Command Institutional Review Board. Performing the SPT from a chair significantly (P < .05) increased performance when compared to performing the SPT from the ground (5.4 ± 1.3 m versus 5.0 ± 1.4 m, respectively). Values for the two SPT variants were correlated (tau = 0.90). Performing the SDL using the hex-bar significantly increased the maximal weight lifted when compared to performing the SDL using paired dumbbells (86.9 ± 18.4 kg versus 83.1 ± 18.0 kg, respectively). Values for the two SDL variants were correlated (tau = 0.83). Performing different variants of the SPT and SDL influenced the resulting score. Although these findings do not alter the administration or scoring of the OPAT, they do provide a valuable reference in the event of future inquiries regarding the development of the OPAT.

General & Internal Medicine↗

The Completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: exploring the halo occupation distribution model for emission line galaxies

We study the modelling of the halo occupation distribution (HOD) for the eBOSS DR16 emission line galaxies (ELGs). Motivated by previous theoretical and observational studies, we consider different physical effects that can change how ELGs populate haloes. We explore the shape of the average HOD, the fraction of satellite galaxies, their probability distribution function (PDF), and their density and velocity profiles. Our baseline HOD shape was fitted to a semi-analytical model of galaxy formation and evolution, with a decaying occupation of central ELGs at high halo masses. We consider Poisson and sub/super-Poissonian PDFs for satellite assignment. We model both Navarro–Frenk–White and particle profiles for satellite positions, also allowing for decreased concentrations. We model velocities with the virial theorem and particle velocity distributions. Additionally, we introduce a velocity bias and a net infall velocity. We study how these choices impact the clustering statistics while keeping the number density and bias fixed to that from eBOSS ELGs. The projected correlation function, w p , captures most of the effects from the PDF and satellites profile. The quadrupole, ξ 2 , captures most of the effects coming from the velocity profile. We find that the impact of the mean HOD shape is subdominant relative to the rest of choices. Here, we fit the clustering of the eBOSS DR16 ELG data under different combinations of the above assumptions. The catalogues presented here have been analysed in companion papers, showing that eBOSS RSD+BAO measurements are insensitive to the details of galaxy physics considered here. These catalogues are made publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing the Fulde-Ferrell-Larkin-Ovchinnikov Phase by Double Occupancy Modulation Spectroscopy

In this Letter we consider a spin-imbalanced two-component attractive Fermi gas loaded in a 1D optical lattice in the presence of an harmonic confining potential. We propose that the observation of the change in the double occupancy with respect to a lattice depth modulation can provide clear evidence of the Fulde-Ferrell-Larkin-Ovchinnikov (FFLO) phase. Simulating the time evolution of the system, we can characterize the double occupancy spectrum for different initial conditions. In particular, we numerically observe a striking narrowing of the width of the spectrum for increasing imbalance. Using Bethe-ansatz equations in the strongly interacting limit, we show that the width relates directly to the FFLO wave vector q.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Decoding Ethiopian Abodes: Towards Classifying Buildings by Occupancy Type Using Footprint Morphology

Building occupancy classification plays a crucial role in urban planning, disaster management, and population modeling. Traditional methods often require extensive field surveys or detailed datasets, which can be time-consuming, expensive, and may yield incomplete or erroneous data. In this paper, we present a novel approach for classifying buildings as residential or non-residential using only building footprint data. By extracting geometric shape derivatives that characterize building morphology, we developed a high-accuracy classification model employing a combination of unsupervised and supervised learning methods. We utilized open-source data from Open Street Map, aggregating it to create binary labels for buildings based on their respective human use type. Our approach demonstrates the potential for scalability without the need for additional data sources other than building footprints and labels, offering a more efficient solution for building occupancy classification.

Adams, Daniel↗

SU-E-I-57: Estimating the Occupational Eye Lens Dose in Interventional Radiology Using Active Personal Dosimeters Worn On the Chest

Purpose: To provide a general formalism for determination of occupational eye lens dose based on the response of an active personal dosimeter (APD) worn at chest level above the radiation protection apron. Methods: The formalism consists of three factors: (1) APD conversion factor converting the reading at chest level (APDchest) to the corresponding personal dose equivalent at eye level, (2) Dose conversion factor transferring the measured dose quantity, Hp(10), into a dose quantity relevant for the eye lens dose, (3) Correction factor accounting for differences in exposure of the eye(s) compared to the exposure at chest level (e.g., due to protective lead glasses).The different factors were investigated and evaluated based on phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. Results: The eye lens dose can be conservatively estimated by assigning an appropriate numerical value to each factor entering the formalism that in most circumstances overestimates the dose. Doing so, the eye lens dose to the primary operator and assisting staff was estimated in this work as D-eye,primary = 2.0 APDchest and D-eye,assisting = 1.0 APDchest, respectively.The annual eye lens dose to three nurses and one cardiologist was estimated to be 2, 2, 2, and 13 mSv (Hp(0.07)), respectively, using a TLD dosimeter worn at eye level. In comparison, using the formalism and APDchest measurements, the respective doses were 2, 2, 2, and 16 mSv (Hp(3)). Conclusion: The formalism outlined in this work can be used to estimate the occupational eye lens dose from the response of an APD worn on the chest. The formalism is general and could be applied also to other types of dosimeters. However, the numerical value of the different factors may differ from those obtained with the APD’s used in this work due to differences in dosimeter properties.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-02: Occupational Conceptus Doses From Fluoroscopically-Guided Interventional Procedures

Purpose: The aim of this method was to provide dosimetric data on conceptus dose for the pregnant employee who participates in fluoroscopically-guided interventional procedures. Methods: Scattered air-kerma dose rates were obtained for 17 fluoroscopic projections involved in interventional procedures. These projections were simulated on an anthropomorphic phantom placed on the examination table supine. The operating theater was divided into two grids relative to the long table sides. Each grid consisted of 33 cells spaced 0.50 m apart. During the simulated exposures, at each cell, scatter air-kerma rate was measured at 110 cm from the floor i.e. at the height of the waist of the pregnant worker. Air-kerma rates were divided by the dose area product (DAP) rate of each exposure to obtain normalized data. For each projection, measurements were performed for 3 kVp and 3 filtration values i.e. for 9 different x-ray spectra. All measurements were performed by using a modern C-arm angiographic system (Siemens Axiom Artis, Siemens, Germany) and a radiation meter equipped with an ionization chamber. Results: The results consist of 153 iso-dose maps, which show the spatial distribution of DAP-normalized scattered air-kerma doses at the waist level of a pregnant worker. Conceptus dose estimation is possible using air-kerma to embryo/fetal dose conversion coefficients published in a previous study (J Cardiovasc Electrophysiol, Vol. 16, pp. 1–8, July 2005). Using these maps, occupationally exposed pregnant personnel may select a working position for a certain projection that keeps abdominal dose as low as reasonably achievable. Taking into consideration the regulatory conceptus dose limit for occupational exposure, determination of the maximum workload allowed for the pregnant personnel is also possible. Conclusion: Data produced in this work allow for the anticipation of conceptus dose and the determination of the maximum workload for a pregnant worker from any fluoroscopically-guided interventional procedure. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)

60 APPLIED LIFE SCIENCES↗

OpenStudio Occupant-centric KPIs Reporting Measure v1.0

This is an OpenStudio measure that calculates and reports the occupant-centric key performance indicators (KPIs) for evaluating building energy performance from occupant-centric perspectives. The measure automatically calculate the KPIs in the following categories: (1) visual & lighting, (2) thermal (3) air quality, and (4) others.

Hong, Tianzhen↗

Toward Human-Centric Transportation and Energy Metrics: Influence of Mode, Vehicle Occupancy, Trip Distance, and Fuel Economy

Traditional metrics measuring transportation and energy outcomes can be augmented to better represent impacts on people's lives and systems-level performance. In this context, this study introduces two novel metrics: road capacity (as number of people traveling and accessing services) and energy intensity (as energy use for people traveling and accessing services). Current national-level distributions of available data in the United States for factors contributing to the two new integrated metrics are used as context to evaluate potential outcomes. These factors include vehicle occupancy, mode share, fuel economy, and trip distance. Variations in input values provide insights on how these factors shape efficiencies in road capacity and energy intensity. Parametric sensitivity analysis indicates that the impact of each input depends upon the metric being evaluated. For the human-centered road capacity mobility metric, increasing vehicle occupancy has the largest effect &ndash; twice that of increasing mode share for bike, walk, and transit. For the energy intensity mobility metric, the effect of improving fuel economy is the largest. However, when the focus is on accessibility (instead of mobility), for both metrics the effect of lowering average trip distance is the largest. Additionally, a novel interactive tool to visualize the results for various parameter combinations makes the metrics practitioner ready. The findings suggest that the diffusion of new human-centric metrics that benchmark outcomes associated with road capacity and energy may be significant in motivating new sustainable transportation investments and efficient utilization of infrastructure, mobility assets, and services.

ADVANCED PROPULSION SYSTEMS↗

Spatial and temporal variations in indoor environmental conditions, human occupancy, and operational characteristics in a new hospital building

The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.

54 ENVIRONMENTAL SCIENCES↗

Occupational radiation Exposure at Agreement State-Licensed Materials Facilities, 1997-2010

The purpose of this report is to examine occupational radiation exposures received under Agreement State licensees. As such, this report reflects the occupational radiation exposure data contained in the Radiation Exposure Information and Reporting System (REIRS) database, for 1997 through 2010, from Agreement State-licensed materials facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Zone Level Occupant-Responsive Building Energy Systems at the GSA

The General Services Administration (GSA) partnered with the U.S. Department of Energy (DOE) to develop and implement building energy system retrofits, aiming to reduce energy consumption of at least two building systems by a total of 30 percent or more, as part of DOE’s Commercial Building Partnership (CBP) Program. Lawrence Berkeley National Laboratory (LBNL) provided technical expertise in support of this DOE program, working with the GSA and a team of consultants. This case study reports expected energy savings from appropriate energy efficient design and operations modifications to lighting and heating, ventilating and air conditioning (HVAC) systems at the selected study sites. These retrofits comprised installation of new lighting systems with dimming capability and occupancy-sensor control at the individual light fixture level, and utilized lighting system occupancy sensor signals to continually readjust zone-level ventilation airflow according to the number of people present, down to minimum rates when vacant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A post-occupancy monitored evaluation of the dimmable lighting, automated shading, and underfloor air distribution system in The New York Times Building

With aggressive goals to reduce national energy use and carbon emissions, the US Department of Energy will be looking to exemplary buildings that have already invested in new approaches to achieving the energy performance goals now needed at a national level. The New York Times Building, in New York, New York, incorporates a number of innovative technologies, systems and processes and could become a model for widespread replication in new and existing buildings. Post-occupancy data are invaluable in establishing confidence in innovation. A year-long monitored study was conducted to verify energy performance, assess occupant comfort and satisfaction with the indoor environment, and evaluate impacts on maintenance and operations. Lessons learned were derived from the analysis; these lessons could help identify and shape policy, financial, or supporting strategies to accelerate diffusion in the commercial building market.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Automated Measurement and Verification and Innovative Occupancy Detection Technologies

In support of DOE’s sensors and controls research, the goal of this project is to move toward integrated building to grid systems by building on previous work to develop and demonstrate a set of load characterization measurement and evaluation tools that are envisioned to be part of a suite of applications for transactive efficient buildings, built upon data-driven load characterization and prediction models. This will include the ability to include occupancy data in the models, plus data collection and archival methods to include different types of occupancy data with existing networks and a taxonomy for naming these data within a Volttron agent platform.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Practical Guide for Use Of Real Time Detection Systems For Worker Protection And Compliance With Occupational Exposure Limit

This white paper presents practical guidance for field industrial hygiene personnel in the use and application of real time detection systems (RTDS) for exposure monitoring. The focus of the paper is on protection of worker health with solid exposure decisions based on occupational exposure limits (OELs), while successfully managing compliance with applicable regulations. This paper discusses occupational exposure assessment, OELs, traditional use of RTDS, use and limitations of RTDS, use of RTDS for compliance, documentation and reporting of RTDS results. It provides practical matrices for real time monitoring decisions, and a data collection and interpretation worksheet. The paper also addresses the use of professional judgement as it relates to RTDS use.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accessing Wi-Fi Data for Occupancy Sensing

A key issue for saving energy in buildings is to assure that delivery of energy services matches building occupancy as closely as possible, to assure that energy is not wasted providing the services to empty rooms or buildings, and to assure that needed services are provided during all times when desired. Accomplishing this to date has been significantly hampered by a lack of inexpensive mechanisms to obtain and use building-wide and more granular data about occupancy. In recent years, the concept of inferential (or implicit) sensing has been proposed and explored to use data from IT systems that already exists in most buildings, to obtain data that are not perfect, but are nearly free to obtain. Past work by LBNL and others has primarily demonstrated the principle and potential for this, with a primary focus on data from Wi-Fi networks as the best near-term opportunity for inferential sensing from IT networks. This is due to its near-ubiquity, ease of explanation to many audiences, relative uniformness in deployment, low latency of detection, clear ways to mitigate privacy and security, and other benefits (Price et al., 2015). While the potential and value are clear, researchers or building managers who want to obtain the data lack a source of information to understand what data might exist, what devices may have it, and what mechanisms are available to obtain the data. The purpose of this report is to fill that gap. The report begins with a review of institutional issues in collecting such data, including very real concerns about privacy and IT security. It then describes the various system architectures used in Wi-Fi systems in commercial buildings today, and a variety of mechanisms that can be used to obtain information from them, including examples of how to use them, and sample output. Next is a summary of how to use such data for several different purposes, from retrospective analysis to dynamic building operation, and a conclusion. An appendix provides additional detail on specific mechanisms available from major equipment manufacturers. The mechanisms specified in this report can be used by building owners and operators to confirm proper operation and uncover any issues or unexpected conditions as a resource for building owners and researchers interesting in utilizing inferential sensing data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Energy Employment Impacts and Occupational Analyses: Building Envelope & Electrification Upgrades

Under the Communities LEAP (Local Energy Action Program) Pilot, the U.S. Department of Energy (DOE) is working with a group of LEAP communities to bolster workforce development initiatives and support the growth of local employment in the clean energy economy. Through this resource, DOE seeks to provide participating communities with an overview of the types of occupations that could be affected by investments in building envelope and building electrification upgrades in existing building stock - differentiating between the residential and commercial sectors. This occupational analysis is intended to be used by communities to inform workforce initiatives (e.g., local training and education programs) as they implement building energy efficiency and electrification projects at scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗