Search NASA⌕ Search

SEARCH · Search NASA

Results for “orifice”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Column Number Density Expressions Through M = 0 and M = 1 Point Source Plumes Along Any Straight Path

Analytical expressions for column number density (CND) are developed for optical line of sight paths through a variety of steady free molecule point source models including directionally-constrained effusion (Mach number M = 0) and flow from a sonic orifice (M = 1). Sonic orifice solutions are approximate, developed using a fair simulacrum fitted to the free molecule solution. Expressions are also developed for a spherically-symmetric thermal expansion (M = 0). CND solutions are found for the most general paths relative to these sources and briefly explored. It is determined that the maximum CND from a distant location through directed effusion and sonic orifice cases occurs along the path parallel to the source plane that intersects the plume axis. For the effusive case this value is exactly twice the CND found along the ray originating from that point of intersection and extending to infinity along the plume's axis. For sonic plumes this ratio is reduced to about 4/3. For high Mach number cases the maximum CND will be found along the axial centerline path. Keywords: column number density, plume flows, outgassing, free molecule flow.

Venting↗

Column Number Density Expressions Through M = 0 and M = 1 Point Source Plumes Along Any Straight Path

Analytical expressions for column number density (CND) are developed for optical line of sight paths through a variety of steady free molecule point source models including directionally-constrained effusion (Mach number M = 0) and flow from a sonic orifice (M 1). Sonic orifice solutions are approximate, developed using a fair simulacrum fitted to the free molecule solution. Expressions are also developed for a spherically-symmetric thermal expansion (M = 0). CND solutions are found for the most general paths relative to these sources and briefly explored. It is determined that the maximum CND from a distant location through directed effusion and sonic orifice cases occurs along the path parallel to the source plane that intersects the plume axis. For the effusive case this value is exactly twice the CND found along the ray originating from that point of intersection and extending to infinity along the plumes axis. For sonic plumes this ratio is reduced to about 43. For high Mach number cases the maximum CND will be found along the axial centerline path.

Column Density↗

Diagnostic Techniques to Elucidate the Aerodynamic Performance of Acoustic Liners

In support of Topic A.2.8 of NASA NRA NNH10ZEA001N, the University of Florida (UF) has investigated the use of flow field optical diagnostic and micromachined sensor-based techniques for assessing the wall shear stress on an acoustic liner. Stereoscopic particle image velocimetry (sPIV) was used to study the velocity field over a liner in the Grazing Flow Impedance Duct (GFID). The results indicate that the use of a control volume based method to determine the wall shear stress is prone to significant error. The skin friction over the liner as measured using velocity curve fitting techniques was shown to be locally reduced behind an orifice, relative to the hard wall case in a streamwise plane centered on the orifice. The capacitive wall shear stress sensor exhibited a linear response for a range of shear stresses over a hard wall. PIV over the liner is consistent with lifting of the near wall turbulent structure as it passes over an orifice, followed by a region of low wall shear stress.

June, Jason↗

Combustion chamber inlet manifold separates vapor from liquid

Circular manifold with tangential orifices at the inner circumference provides for the vapor constituent of a vaporized cryogenic propellant to enter a rocket combustion chamber before the liquid constituent. The vapor is separated from the liquid by centrifugal action and precedes it into the chamber through carefully positioned orifices.

Baker, D. I.↗

Equation relates flow at free jet to flow downstream

Nonlinear equation relates the flowrate at an orifice to that at a station downstream from the orifice. This equation should aid in understanding combustion instabilities and should not be subject to the substantial errors of prior analytical methods.

Fenwick, J. R.↗

Measuring internal dimensions of small transparent objects

Technique individually photographs first the orifice in the transparent object and then a microscopic scale immersed in a liquid having the same index of refraction as the transparent object. Using a scale photograph, the orifice photograph is measured.

Mills, S. M.↗

A neutral particle wake method for measuring the atmospheric temperature from a satellite

A method is described that permits a satellite-borne neutral mass spectrometer to perform measurements of the atmospheric temperature. The method employs the spectrometer to examine the partial pressure variations that occur as the wake of a small rectangular baffle is swept across the entrance orifice of the spectrometer. For a given baffle size and mounting distance from the orifice the depth of the resulting pressure minimum depends only upon the thermal velocity, or temperature, of the observed species. A check upon the validity of the method is obtained by measuring the wake characteristics of more than one species and/or by employing each of several baffle sizes.

Brace, L. H.↗

Thick film silicon growth techniques

Silicon ribbon growth experiments were conducted using orifices (dies) fabricated from SiC-SiO2 mixtures, fused quartz, SiC, and fine-grained, high density graphite. The best results were obtained from graphite dies. A number of different approaches was tried in modifying the thermal gradient in the dies and in holding the dies. The best results here were obtained from a 0.25-in. thick Mo disc holding a graphite die directly and fitting the die quite closely. Ribbon growths as wide as 9 mm were obtained, while the longest ribbon was 450 x 3.5 x 0.5 mm. Resistivities of ribbons grown from graphite dies have been measured over the range of 0.03 to 1.6 ohm-cm. Some thoughts and literature findings are presented regarding refractory oxide materials as potential orifices.

Bates, H. E.↗

Piston manometer as an absolute standard for vacuum gage calibration in the range 10 to 700 microtorr

Total pressure in a calibration chamber is determined by measuring the force on a disk suspended in an orifice in the baseplate of the chamber. The disk forms a narrow annular gap with the orifice. A continuous flow of calibration gas passes through the chamber and annulus to a downstream pumping system. The ratio of pressures on the two faces of the disk exceeds 100:1, so that chamber pressure is substantially equal to the product of disk area and net force on the disk. This force is measured with an electrodynamometer that can be calibrated in situ with dead weights. Probable error in pressure measurement is plus or minus (0.5 microtorr + 0.6 percent).

Warshawsky, I.↗

Subsonic wind-tunnel tests of a trailing-cone device for calibrating aircraft static pressure systems

A trailing-cone device for calibrating aircraft static-pressure systems was tested in a transonic wind tunnel to investigate the pressure-sensing characteristics of the device including effects of several configuration changes. The tests were conducted at Mach numbers from 0.30 to 0.95 with Reynolds numbers from (0.9 x one million to 4.1 x one million per foot). The results of these tests indicated that the pressures sensed by the device changed slightly but consistently as the distance between the device pressure orifices and cone was varied from 4 to 10 cone diameters. Differences between such device-indicated pressures and free-stream static pressure were small, however, and corresponded to Mach number differences of less than 0.001 for device configurations with pressure orifices located 5 or 6 cone diameters ahead of the cone. Differences between device-indicated and free-stream static pressures were not greatly influenced by a protection skid at the downstream end of the pressure tube of the device nor by a 2-to-1 change in test Reynolds number.

Jordan, F. L., Jr.↗

Space shuttle: An investigation of the load distribution over the SRB and external tank of a 0.004 scale model of the 049 space shuttle launch configuration

A study was conducted in a trisonic wind tunnel to determine the load distribution over the external tank and solid rocket boosters of the space shuttle launch configuration. The external tank was sting-supported and the solid rocket boosters and orbiter were mounted directly on the external tank. The external tank was, instrumented with 152 pressure orifices and the solid rocket boosters contained 78 orifices. The pressure data were obtained for various combinations of the three geometric components as the gap size between the external tank and the solid rocket boosters, angle of attack, and angle of sideslip were varied. Mach numbers ranged from 0.8 to 1.96.

Lott, R. A.↗

Externally pressurized gas-lubricated journal bearings with herringbone grooves - Load capacity and stability analysis.

A small eccentricity analysis was performed to predict load capacity and stability. Numerical results were obtained for a range of feeding parameter, pressure ratio, groove length and orifice recess volume for compressibility numbers from 0 to 50. These results were obtained from a digital computer program. Results showed that the addition of herringbone grooving to an externally pressurized bearing increases stability, but reduces load capacity at low compressibility numbers. A fully-grooved bearing is more stable than a partially-grooved bearing. Orifice recesses reduce stability, especially at high compressibility numbers.

Fleming, D. P.↗

Theory of a generalized Helmholtz resonator.

Based on the jet-flow model which is manifested in the nonlinearity of the orifice flow upon the passage of a high intensity wave, the theory of a generalized Helmholtz resonator has been developed. The results for some special devices, such as the conventional Helmholtz resonator and the quarter-wave tube, can be obtained through this general approach. The performance of the acoustic damper is characterized by a quantity known as the real part of the admittance coefficient. It is known that the conventional Helmholtz resonator has the lowest peak performance but the response is quite flat over a certain frequency range. On the other hand, a quarter-wave tube offers the largest peak in energy absorption with rather poor off-resonance behavior. Once the orifice length goes beyond the quarter-wave tube configuration, the performance of the so-called long damping device is even less attractive away from resonance.

Tang, P. K.↗

The diluter-demand oxygen system used during the international Himalayan expedition to Mount Everest.

The diluter-demand regulators are designed in such a way that as the individual inspires he simultaneously draws ambient air and pure oxygen from a tank into his mask. The size of the ambient air orifice is made directly proportional to the barometric pressure by use of a passive aneroid valve. As altitude increases the ambient air orifice is automatically made smaller and the individual inspires a greater proportion of oxygen.

Blume, F. D.↗

Lyophilized spore dispenser

A lyophilized spore dispenser is provided which produces a finely divided, monoparticulate cloud of bacterial spores. The spores are contained within a tightly sealed chamber, and a turbulator orifice connected to an air supply source provides a jet of air which stirs up the spores and causes the spores to be suspended in eddy currents within the chamber. This air jet also produces a positive pressure within the chamber which forces the spores out of an injection orifice.

Jessup, A. D.↗

Terminal-shock and restart control of a Mach 2.5, axisymmetric, mixed compression inlet with 40 percent internal contraction

Results of experimental tests conducted on a supersonic, mixed-compression, axisymmetric inlet are presented. The inlet is designed for operation at Mach 2.5 with a turbofan engine (TF-30). The inlet was coupled to either a choked orifice plate or a long duct which had a variable-area choked exit plug. Closed-loop frequency responses of selected diffuser static pressures used in the terminal-shock control system are presented. Results are shown for Mach 2.5 conditions with the inlet coupled to either the choked orifice plate or the long duct. Inlet unstart-restart traces are also presented. High-response inlet bypass doors were used to generate an internal disturbance and also to achieve terminal-shock control.

Baumbick, R. J.↗

Effect of cavitation on fluid stability in polymer thickened fluids and lubricants

The effects of cavitating flow on the polymeric additives used in functional fluids are described. A comparison of thermal and mechanical stability tests for these polymer solutions show distinct differences in the machanism of the polymer degradation. The thermal degradation tests appear to cause an unzippering or depolymerization type of reaction in which there is no particular selectivity based on molecular weight. The mechanical degradation of these fluids appears to be based on molecular weight. Measurements of molecular weight distributions during mechanical degradation show that for a given level of intensity only molecules above a certain minimum size are degraded. The effects of ultrasonic radiation on polymer degradation are reported. Tests were conducted to demonstrate the mechanism of mechanical polymer degradiation in an orifice. A more severe test than the orifice test in which two tapered roller bearings loaded against each other produce the mechanical breakdown is discussed.

Duda, J. L.↗

Nonlinear gas oscillations in pipes. II - Experiment

The problem of forced acoustic oscillations in a pipe was experimentally investigated, taking into account the response of both open and closed tubes to near-resonant excitation by large amplitude oscillations of a piston at one end of the tube. Attention was given to the effect of the orifice area on shock waves. By comparing the experimental results with nonlinear theory, wave reflection coefficients of the orifice plates were determined at both closed-tube and open-tube resonant frequencies. This approach can even be used when the terminating elements are subjected to intense periodic pressure pulses.

Sturtevant, B.↗