Search NASA⌕ Search

SEARCH · Search NASA

Results for “readout electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quality assurance test of silicon photomultipliers and electronic boards for STAR event plane detector

The event plane detector (EPD), installed in the Solenoid Tracker at the Relativistic Heavy-Ion Collider located at the Brookhaven National Laboratory is a plastic scintillator-based device that measures the reaction centrality and event plane in the forward region of the relativistic heavy-ion collisions. We used silicon photomultiplier (SiPM) arrays to detect the photons produced in the scintillator via the fiber connection. Signals from the SiPM arrays were amplified by the front-end electronic (FEE) board, and sent to the analog-to-digital converter (ADC) boards for further processing via the receiver (RX) board. The full EPD system consisted of 24 super-sectors (SSs); each SS was equipped with two SiPM boards, two FEE boards and two RX boards, and they corresponded to 744 readout channels. All these boards were mass produced at the University of Science and Technology of China, with a dedicated quality assurance (QA) procedures applied to identify any problems before deployment. This article describes the details of the QA method and the related test system. As a result, the QA test results are presented along with the discussions.

EPD↗

Synthesis of nanodiamonds encapsulated by zeolitic imidazole framework-8 for quantum sensing applications

Nitrogen vacancy (NV)-containing nanodiamonds are widely used in quantum sensing applications due to their high sensitivity to magnetic fields, relatively low cost, and ability to be initialized, manipulated, and read out at room temperature. Quantum sensing techniques such as optically detected magnetic resonance (ODMR) and spin relaxometry have exploited the sensitivity of the NV nanodiamonds to magnetic fields to detect a range of analytes, such as pH, metal ions, and biomolecules. However, diversifying the sensing targets accessible by NV diamond quantum sensors typically requires careful engineering of the diamond surface chemistry with stimuli-responsive functional groups. Here, a simple protocol for coating NV nanodiamonds with the zeolitic imidazole framework 8 (ZIF-8), a widely used metal-organic framework, is presented. ZIF-8 is a highly porous material that has been used as a selective sensor for gasses, metal ions, and other analytes. The material is well-characterized by x-ray diffraction, transmission electron microscopy, scanning electron microscopy, x-ray photoelectron spectroscopy, and luminescence spectroscopy. Encapsulation of NV nanodiamonds with a porous scaffold such as ZIF-8 provides a promising method for improving the selectivity for the quantum sensing of various analytes. Importantly, the ZIF-8 coating does not impact the luminescence properties of the NV diamond, which is a key readout in ODMR and spin relaxometry sensing approaches. Indeed, the ODMR spectra with and without the ZIF-8 shell is nearly identical. Moreover, the ZIF-8 coating increases the longitudinal spin relaxation time of the NV nanodiamond by a factor of 4 relative to aggregated diamond, a desirable outcome for spin relaxation-based quantum sensing. Metal-organic framework composites with nanodiamonds thus are an exciting strategy for enhancing NV nanodiamond performance in applications such as quantum sensing and quantum-enhanced nuclear magnetic resonance spectroscopy.

nitrogen vacancy nanodiamond↗

Spectroscopic Measurements and Models of Energy Deposition in the Substrate of Quantum Circuits by Natural Ionizing Radiation

Naturally occurring background radiation is a potential source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. In order to characterize the radiation environment in an unshielded laboratory representative of superconducting qubits’ environments, we performed broadband, spectroscopic measurements of background radiation events inside a millikelvin refrigerator. The spectrometer was designed to mimic the size and composition of a quantum circuit. Specifically, we measured the background radiation spectra in silicon substrates of two thicknesses, 500 and 1500 µm, and one area, 25 mm 2 . The observed spectra span energies from a few kilo-electron-volts up to nearly 10 MeV, are nearly featureless, and decrease in intensity by a factor of 40 000 between 100 keV and 3 MeV for the 500-µm substrate. We integrate the spectra to obtain the average event rates and deposited power levels. These quantities correspond to a rate of 0.023 events per second and a power of 4.9 keV s -1 , when counting events that deposit at least 40 keV for the 500-µm-thick substrate. We find that the cryogenic measurements are in good agreement with predictions based on simple measurements of the terrestrial gamma-ray flux outside the refrigerator, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. This model requires no free parameters to predict the background radiation spectra in the silicon substrates. The agreement between measurements and predictions demonstrates that the model we present can be used to assess the relative contributions of terrestrial and cosmic-ray sources to background radiation interactions in silicon substrates of varying thickness. These spectroscopic measurements are performed with a novel combination of superconducting microresonators located on micromachined silicon islands that define the interaction volume with background radiation. The resonators transduce deposited energy to a readily detectable electrical signal. Microresonator readout closely resembles dispersive superconducting qubit readout, so similar devices—with or without micromachined islands—are suitable for integration with superconducting quantum circuits as detectors for background radiation events. For our specific laboratory conditions, we find that gamma-ray emissions from radioisotopes are responsible for the majority of events that deposit E < 1 ⁢Me⁢V. We present results demonstrating that the background radiation spectrum contains relevant contributions from cosmic-ray particles other than muons, particularly a tail of multi-mega-electron-volt events due to protons and neutrons. These observations suggest several paths to reducing the impact of background radiation on quantum circuits, supported by an empirically validated model for generating reliable predictions of radiation interactions with silicon substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

Intelligent Experiments Through Real-time AI: Fast Data Processing and Autonomous Detector Control for sPHENIX and Future EIC Detectors (Final Report)

The overall vision of this project was to integrate real-time artificial intelligence (AI) directly into the data acquisition and detector-control systems of nuclear physics experiments, including both fast online event selection and an autonomous detector-control feedback loop. The work carried out under the award focused on the fast online event-selection half of that vision: the efficient recording of low-momentum heavy-flavor (HF) hadron decays in proton-proton collisions at the sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC)—an observable that requires fast tracking and topological trigger selection not previously demonstrated at RHIC, and that is essential for QCD studies at future facilities such as the Electron-Ion Collider (EIC). The autonomous detector-control (GPU-based feedback) component named in the project title remained a design concept and was not implemented under this award. The Massachusetts Institute of Technology (MIT) group led the offline simulation and data processing needed to train the machine-learning (ML) models, the translation of trained models to Field-Programmable Gate Array (FPGA) firmware using the hls4ml framework, and the physics validation of heavy-flavor reconstruction. Over the award period, the team developed and hardware-tested the principal components of an AI-based heavy-flavor trigger on simulated and recorded sPHENIX tracker data: a software Bipartite Graph Attention Network (BiGAT) trigger model reaching > 95% signal efficiency at 99% background rejection; an FPGA-native hit clusterizer matching the offline clustering; smaller networks synthesized to FPGA within the required sub-10 µs latency; and an assembled decoder–clusterizer–inference firmware chain exercised on the FELIX readout board. A complete, fully integrated hardware demonstrator was not finished within the award period. This report documents the project goals, the MIT group’s contributions, the technical accomplishments, and the outlook toward applications at the future EIC ePIC detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First 3D vector tracking of helium recoils for fast neutron measurements at Super$\mathrm{KEKB}$

Here we present results from the first deployment of novel, high definition, compact gas Time Projection Chambers (TPCs) with pixel chip readout as part of the BEAST II beam background measurement project at SuperKEKB. The TPCs provide detailed 3D imaging of ionization from neutron-induced nuclear recoils in a helium and carbon dioxide target gas mixture at standard temperature and pressure. We present the TPC performance and the neutron backgrounds observed during the initial stage of collider commissioning. We find excellent electron background rejection, leading to background-free nuclear recoil measurements above 50 keV ee , despite the extreme high-background environment. We measure an angular resolution better than 20° for recoil tracks longer than 1.7 mm, corresponding to an average ionization energy of approximately 100 keV ee . We also obtain the full 3D vector direction of helium recoils by utilizing charge profile measurements along the recoil axis, with a correct head/tail assignment efficiency of approximately 80%. With this performance, we present comparisons between measured and simulated event rates, recoil energy spectra, and directional distributions originating from beam–gas and Touschek beam losses at SuperKEKB. We utilize head/tail recognition to distinguish neutron components traveling with positive radial velocity in the Belle II coordinate system from those traveling in the opposite direction. Finally, we present a novel method of discriminating beam–gas interactions from Touschek beam losses that can eliminate the need for dedicated accelerator runs for background measurements. This method is still statistics-limited. However, future studies should be able to verify this method, which in turn could lead to neutron background analysis runs symbiotic with normal Belle II operation. The capabilities demonstrated here also suggest that high definition recoil imaging in gas TPCs is applicable to low energy, low-background experiments, such as directional dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Low Cost SIPM Evaluation and Control Prototyping System including accurate bias voltage generation, leakage current measurement, and temperature control using Peltier cooling

We describe an electronics system to operate SIPMs in the laboratory. The system is comprised of a single channel amplifier board (SIPM Amp) and a 4-channel control board to which up to 4 SIPM Amp boards can be connected. The control board supplies a common low voltage power for the amplifiers. All channels feature individually regulated bias and Peltier power voltages, along withPt10K RTD readout. A graphical user interface allows control of the bias voltages, amplifier voltage, Peltier voltages, and also provides for readback of leakage currents and other voltages. The GUI app has a feedback loop to measure the SIPM temperature (with the PT10K) and generate correction voltages to the Peltier to regulate the temperature. The temperatures, which can be achieved by Peltier cooling depend on the thermal design of the setup, the practical limit being about 50C below ambient. The SIPM Amp. board is a small (3x5cm) PCB that has a single SIPM readout channel. The SIPM scan be surface mounted on the pcb or connected to a 2-pin 0.100" socket. The area around the SIPM footprint is thermally isolated by perforations in the PCB. The RTD is located inside the thermal break. Onboard is BV and LV filtering. The 10X amplifier is based on MiniCircuits' GALI-S66+ integrated circuit, tweaked for a 6V power. The amplifier was selected for a combination of high bandwidth, low noise, and low power. An accoupled amplifier output is connected to an SMA connector. For best operation of this inverting amplifier the output signal should be in the range of 0 to -1V.The Amplifier board is connected to the Control board with a 10-conductor 0.025" pitch ribbon cable, carrying all the services. Peltier power for currents more than 1A should use a separate 2-contact connector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of selenium imaging detectors toward a definitive search for neutrinoless ββ decay

Imaging sensors made from an ionization target layer of amorphous selenium (aSe) coupled to a silicon complementary metal-oxide-semiconductor (CMOS) active pixel array for charge readout are a promising technology for neutrino physics. The high spatial resolution in a solid-state target provides unparalleled rejection of backgrounds from natural radioactivity in the search for the neutrinoless ββ decay of 82 Se. With this grant, we experimentally determined two crucial factors necessary for the realization of this novel technology: i) the intrinsic energy response of aSe to ionizing electrons, and ii) the feasibility to couple a target layer of aSe to a CMOS active pixel sensor to image electron tracks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale engineering and dynamic stabilization of mesoscopic spin textures

Thermalization, while ubiquitous in physics, has traditionally been viewed as an obstacle to be mitigated. In contrast, we demonstrate here the use of thermalization in the generation, control, and readout of “shell-like” spin textures with interacting 13 C nuclear spins in diamond, wherein spins are polarized oppositely on either side of a critical radius. The textures span several nanometers and encompass many hundred spins; they are created and interrogated without manipulating the nuclear spins individually. Long-time stabilization is achieved via prethermalization to a Floquet-engineered Hamiltonian under the electronic gradient field: The texture is therefore metastable and robust against spin diffusion. This enables the state to endure over multiple minutes before it decays. Our work on spin-state engineering paves the way for applications in quantum simulation and nanoscale imaging.

42 ENGINEERING↗

Research in Neutrino Physics (Final Technical Report)

The goal of the experimental neutrino efforts at Louisiana State University is to measure the properties of neutrinos and to improve our understanding of neutrino interactions. In pursuit of this goal, the group will continue its Intensity Frontier work on the DUNE experiment at Fermilab and the T2K experiment at J-PARC, Japan. The current work is focused on understanding how neutrinos change flavor and on the possibility for asymmetry between neutrinos and anti-neutrinos. The effort on T2K includes physics measurements using the collected T2K data and preparation for the second phase T2K-II data with an increased beam power and the newly upgraded ND280 detector, featuring a novel 3D fine grained scintillation tracker with 4π acceptance and 3D readout. T2K is in a position to improve our understanding of neutrino nucleus interactions which continue to be one of the largest systematic uncertainties for neutrino oscillation measurements. On DUNE, the effort is on analyzing the data collected by the ProtoDUNE-SP prototype at CERN and on the design, installation, and commissioning of ProtoDUNE-II and later the DUNE Far Detector cold electronics. The final DUNE Module-1 components will be fully characterized by ProtoDUNE-II and the collected data will be used to improve and tune simulation and reconstruction algorithms, and to measure hadron scattering cross section, used to improve the modeling of neutrino final state interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unraveling Fano noise and the partial-charge-collection effect in x-ray spectra below 1 keV

Fano noise, readout noise, and the partial-charge-collection (PCC) effect collectively contribute to the degradation of energy spectra in charge-coupled device (CCD) measurements, especially at low energies. Here, in this work, the x rays produced by the fluorescence of fluorine (677 eV) and aluminum (1486 eV) were recorded using a Skipper-CCD, which enabled the readout noise to be reduced to 0.2 e - . Based on an analytical description of photopeak shapes resulting from the convolution of the PCC effect and Fano noise, we achieved a precise characterization of the energy spectra. This description enabled us to disentangle and quantify the contributions from both Fano noise and the PCC effect. As a result, we determined the Fano factor and the electron-hole pair creation energy. Additionally, we estimated the PCC region of the sensor and, for the first time, experimentally observed the expected skewness of photopeaks at low energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deployment of ADTimePix3 areaDetector Driver at Neutron and X-ray User Facilities

TimePix3 is a 65k hybrid pixel readout chip with simultaneous Time-of-Arrival (ToA) and Time-over-Threshold (ToT) recording in each pixel*. The chip operates without a trigger signal with a sparse readout where only pixels containing events are read out. The flexible architecture allows 40 MHits/s/cm² readout throughput, using simultaneous readout and acquisition by sharing readout logic with transport logic of superpixel matrix formed using 2x4 structure. The chip ToA records 1.5625 ns time resolution. The X-ray and charged particle events are counted directly. However, indirect neutron counts use 6Li fission in a scintillator matrix, such as ZnS(Ag). The fission space-charge region is limited to 5-9 um. A photon from scintillator material excites a photocathode electron, which is further multiplied in dual-stack MCP. The neutron count event is a cluster of electron events at the chip. We report on the EPICS areaDetector** ADTimePix3 driver that controls Serval*** using json commands. The driver directs data to storage and to a real-time processing pipeline and configures the chip. The time-stamped data are stored in raw .tpx3 file format and passed through a socket where the clustering software identifies individual neutron events. The conventional 2D images are available as images for each exposure frame, and a preview is useful for sample alignment. The areaDetector driver allows integration of time-enhanced capabilities of this detector into SNS beamlines controls and unprecedented time resolution.

Gofron, Kaz↗

Beam test results for the Endcap Timing ReadOut Chip (ETROC2) for the CMS ETL upgrade

The Endcap Timing ReadOut Chip (ETROC) for the Compact Muon Solenoid (CMS) Minimum ionizing particle Timing Detector (MTD) is designed to process Low Gain Avalanche Diode (LGAD) signals with a time resolution of 40-50ps per hit, with 30-35 ps per charged particle using two layer detector. The ETROC2, is the first full size (16x16 pixels) and full functionally design that has been tested in hadron and electron beams at CERN and DESY (Sep 2023 - June 2024). Precision timing studies at these test beams are done using a self-referential beam telescope composed of up to 4 layers/chips. This talk describes the ETROC2 beam telescope and summarizes the performance of the ETROC2 chips bump-bonded to (16x16) Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) LGAD sensors using results from recent test beams. The experiences and lessons learned during the course of these test beams are also detailed in this talk.

Safdari, Murtaza↗

X-ray Response of the Fully-Depleted, p-Channel SiSeRO-CCD

We present an X-ray characterization of a fully depleted, 725 $μ$m thick p-channel SiSeRO CCD. Measurements with a $^{55}$Fe source yield an energy resolution of $54 \pm 0.9$ eV ($14.6 \pm 0.25 e^{-}$) at 5.9 keV for single-pixel events, demonstrating that the SiSeRO amplifier preserves the intrinsic charge resolution of the CCD under multi-sample non-destructive readout. Characterization with a $^{241}$Am source extends the response to higher-energy photons, with reconstructed spectral features observed between 9-26 keV and the 59.5 keV $γ$ emission. These measurements, together with a muon-derived diffusion calibration, show that charge transport and diffusion are consistent with interactions spanning the full sensor depth. These results demonstrate that the SiSeRO CCD simultaneously achieves sub-electron noise performance and efficient charge collection in a thick, fully depleted silicon detector. This combination enables X-ray spectroscopy across a broad energy range while maintaining sensitivity to faint signals.

Cuevas-Zepeda, Julian↗

Trapped Electrons and Ions as Particle Detectors

Electrons and ions trapped with electromagnetic fields have long served as important high-precision metrological instruments, and more recently have also been proposed as a platform for quantum information processing. Here we point out that these systems can also be used as highly sensitive detectors of passing charged particles, due to the combination of their extreme charge-to-mass ratio and low-noise quantum readout and control. In particular, these systems can be used to detect energy depositions many orders of magnitude below typical ionization scales. As illustrations, we suggest some applications in particle physics. We outline a nondestructive time-of-flight measurement capable of sub-eV energy resolution for slowly moving, collimated particles. We also show that current devices can be used to provide competitive sensitivity to models where ambient dark matter particles carry small electric millicharges $\ll$e. Furthermore, our calculations may also be useful in the characterization of noise in quantum computers coming from backgrounds of charged particles.

47 OTHER INSTRUMENTATION↗

Development of High-QE GaN Photodectors for Liquid Noble Particle Detectors

Detection of the handful of photons generated when a dark matter particle interacts in a liquid Xenon detector requires a new type of photodetector with very high detection efficiency at ultraviolet wavelengths, very low radioactive backgrounds, and essentially no measureable readout noise (achieved with devices with high intrisic gain). Such devices would find wide applicability to not only high energy physics experiments, but to a number of commercial applications including, e.g., biomedical imaging of fluorescent tags. We developed photodetectors based on amorphous GaN thin film structures (photocathodes) grown by molecular beam epitaxy on quartz windows. We also developed approaches to integrate these photocathode device structures with vacuum electron multipliers. All materials and fabrication techniques were developed to minimize radioactive backgrounds in materials, so these detectors could be used for very low count rate experiments, such as the future liquid-Xenon dark matter detectors, and future liquid-Argon neutrino detectors. We demonstrated growth of very high quantum efficiency amorphous GaN cathodes grown on a number of different substrates (Stainless steel, p-Silicon) reaching detection efficiencies of 80% at 220nm. The key to this growth was to use nitrogen plasma-assistend MBEs and very low growth temperatures. We also discovered that thinner structures (e.g.,40nm a-GaN thin films) had the best performance. We successfully demonstrated techniques for the vacuum transfer of these photocathode structures to a novel chamber that used hydraulics and bellow to form a cold indium bond needed to integrate these cathodes into sealed-tube devices. A complete, stand-along, device could not be completed during this proposal period due to difficulties in growing structures on the thick quartz window. Subsequent work is aimed at addressing this difficulty, by growing a buffer layer on the quartz substrate.

07 ISOTOPE AND RADIATION SOURCES↗