Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

The National Spherical Torus Experiment-Upgrade poloidal high-k scattering system pitch angle design modifications

A 693 GHz, eight-channel, poloidal high-k (k refers to wavenumber) collective scattering system is under development for the National Spherical Torus Experiment-Upgrade device. It will replace the previous 280 GHz, five-channel, tangential scattering system to study high-k electron density fluctuations, thereby providing a measurement of the k θ -spectrum of both electron temperature gradient and ion temperature gradient modes. A tool is under development to calculate the wavenumber that exists in the presence of strong magnetic pitch angles. Here we use this tool to motivate a new receiver optical design for significantly improved performance, details of which are presented herein.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress in pedestal and edge physics: Chapter 3 of the special issue: on the path to tokamak burning plasma operation

This paper describes the extensive progress that has been made in the understanding of tokamak pedestal physics since the 2007 publication of ‘Progress in the ITER Physics Basis’ (Ikeda 2007 Nucl. Fusion 47 E01–S500). It serves as Chapter 3 of the 2025 Nuclear Fusion Special Issue titled ‘On the Path to Tokamak Burning Plasma Operation’ (Campbell et al 2025 Nucl. Fusion ). This review was compiled by the pedestal and edge physics (PEP) community affiliated with the International Tokamak Physics Activity organization. It attempts to collect in one place citations to the majority of published literature on the pedestal physics topics that will be most important for the operation of a future power producing burning plasma tokamak. These include citations to publications describing the physics of the pedestal plasmas in many operating tokamaks worldwide and the pedestal physics projections for several near-term future devices including ITER. Descriptions of experimental results, interpretive modeling and predictive extrapolations are integrated together and comprehensive references are provided. This review is organized around four primary technical sections, viz.: pedestal structure, edge localized mode (ELM) characteristics, ELM control and regimes without large ELMs. Key results from many of the references are described briefly and set into the tokamak burning plasma power plant context. In addition, different perspectives on pedestal physics topics that are currently under debate within the community are also described, to provide guidance on needs for future research. Finally, attempts are made to describe conclusions from all of this progress consistent with discussions by the pedestal physics community at this time. The goal of this review is to provide a useful reference document for pedestal physics researchers going forward toward operation of a burning tokamak fusion plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards Optimal and Executable Distribution Grid Restoration Planning With a Fine-Grained Power-Communication Interdependency Model

Distribution service restoration (DSR) under natural disasters is always a critical and challenging problem for utility companies. An effective solution must not ignore the power-communication interdependency as various systems are getting increasingly connected in the Smart Grid era. In this paper, we propose a two-layer distribution system model with both power and communication components. Based on this model, we formulate the restoration process as a routing problem that schedules the path and action sequence of utility crews that involves repairing damaged components, closing power switches, and enabling communication paths between the control center and remote field devices. Further, we develop a simulation-based method to quantitatively evaluate the restoration process with public reference models of large-scale power systems. The experimental results show that our method improves the total restored energy up to 57.6% and reduces the recovery time up to 63% by considering the power-communication interdependency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and Validation of Passive Yaw in the Open-Source WEC-Sim Code

A passive yaw implementation is developed, validated, and explored for the WEC-Sim, an open-source wave energy converter modeling tool that works within MATLAB/Simulink. The Reference Model 5 (RM5) is selected for this investigation, and a WEC-Sim model of the device is modified to allow yaw motion. A boundary element method (BEM) code was used to calculate the excitation force coefficients for a range of wave headings. An algorithm was implemented in WEC-Sim to determine the equivalent wave heading from a body’s instantaneous yaw angle and interpolate the appropriate excitation coefficients to ensure the correct time-domain excitation force. This approach is able to determine excitation force for a body undergoing large yaw displacement. For the mathematically simple case of regular wave excitation, the dynamic equation was integrated numerically and found to closely approximate the results from this implementation in WEC-Sim. A case study is presented for the same device in irregular waves. In this case, computation time is increased by 32x when this interpolation is performed at every time step. To reduce this expense, a threshold yaw displacement can be set to reduce the number of interpolations performed. A threshold of 0.01° was found to increase computation time by only 22x without significantly affecting time domain results. Similar amplitude spectra for yaw force and displacements are observed for all threshold values less than 1°, for which computation time is only increased by 2.2x.

50 EE - Wind and Water Power Program - Water (EE-4↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

CCD correlated quadruple sampling processor

A correlated quadruple sampling processor for improved signal-to-noise ratio in the output of a charge-coupled device (CCD) is comprised of: switching means for momentarily clamping a CCD signal line at a first reference level A before a CCD data pulse and then obtaining a first data sample B with respect to the reference A during a CCD data pulse, and storing the positive sample B-A; switching means for momentarily clamping the CCD signal line a second time at the level C during the presence of the CCD data pulse and then obtaining a second data sample D with respect to the reference level C after the CCD data pulse, and storing the negative sample D-C; and means for obtaining the difference between the stored samples +(B-A) and -(D-C), thus increasing the net signal amplitude by a factor of about 2 while the noise would be increased by only a factor of square root of 2 since there will be no correlation in the noise between the double samples +(B-A) and -(D-C) effectively added.

Gaalema, S. D.↗

Summary of Proton Test on the Quick Logic QL3025 at Indiana University

This issue of the Programmable Logic Application Notes is a compilation of topics: (1) Proton irradiation tests were performed on the Quick Logic QL3025 at the Indian University Cyclotron facility. The devices, tests, and results are discussed; (2) The functional failure of EEPROM's in heavy ion environment is presented; (3) the Act 1 architecture is summarized; (4) Antifuse hardness and hardness testing is updated; the single even upset (SEU) response of hardwired flip-flops is also presented; (4) Total dose results of the ACT 2 and ACT 3 circuits is presented in a chart; (5) Recent sub-micron devices testing of total dose is presented in a chart along with brief discussion; and (6) a reference to the WWW site for more articles of interest.

Katz, Richard↗

Development and Validation of Passive Yaw in the Open-Source WEC-Sim Code: Preprint

A passive yaw implementation is developed, validated, and explored for the Wave Energy Converter Simulator (WEC-Sim), an open-source wave energy converter modeling tool that works within MATLAB/Simulink. The Reference Model 5 (RM5) is selected for this investigation, and a WEC-Sim model of the device is modified to allow yaw motion. A boundary element method (BEM) code was used to calculate the excitation force coefficients for a range of wave headings. An algorithm was implemented in WEC-Sim to determine the equivalent wave heading from a body’s instantaneous yaw angle and interpolate the appropriate excitation coefficients to ensure the correct time-domain excitation force. This approach is able to determine excitation force for a body undergoing large yaw displacement. For the mathematically simple case of regular wave excitation, the dynamic equation was integrated numerically and found to closely approximate the results from this implementation in WEC-Sim. A case study is presented for the same device in irregular waves. In this case, computation time is increased by 32x when this interpolation is performed at every time step. To reduce this expense, a threshold yaw displacement can be set to reduce the number of interpolations performed. A threshold of 0.01 was found to increase computation time by only 22x without significantly affecting time domain results. Similar amplitude spectra for yaw force and displacements are observed for all threshold values less than or equal to 1, for which computation time is only increased by 2.2x.

50 EE - Wind and Water Power Program - Water (EE-4↗

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium↗

Acceleration Modes and Transitions in Pulsed Plasma Accelerators

Pulsed plasma accelerators typically operate by storing energy in a capacitor bank and then discharging this energy through a gas, ionizing and accelerating it through the Lorentz body force. Two plasma accelerator types employing this general scheme have typically been studied: the gas-fed pulsed plasma thruster and the quasi-steady magnetoplasmadynamic (MPD) accelerator. The gas-fed pulsed plasma accelerator is generally represented as a completely transient device discharging in approximately 1-10 microseconds. When the capacitor bank is discharged through the gas, a current sheet forms at the breech of the thruster and propagates forward under a j (current density) by B (magnetic field) body force, entraining propellant it encounters. This process is sometimes referred to as detonation-mode acceleration because the current sheet representation approximates that of a strong shock propagating through the gas. Acceleration of the initial current sheet ceases when either the current sheet reaches the end of the device and is ejected or when the current in the circuit reverses, striking a new current sheet at the breech and depriving the initial sheet of additional acceleration. In the quasi-steady MPD accelerator, the pulse is lengthened to approximately 1 millisecond or longer and maintained at an approximately constant level during discharge. The time over which the transient phenomena experienced during startup typically occur is short relative to the overall discharge time, which is now long enough for the plasma to assume a relatively steady-state configuration. The ionized gas flows through a stationary current channel in a manner that is sometimes referred to as the deflagration-mode of operation. The plasma experiences electromagnetic acceleration as it flows through the current channel towards the exit of the device. A device that had a short pulse length but appeared to operate in a plasma acceleration regime different from the gas-fed pulsed plasma accelerators was developed by Cheng, et al. The Coaxial High ENerGy (CHENG) thruster operated on the 10-microseconds timescales of pulsed plasma thrusters, but claimed high thrust density, high efficiency and low electrode erosion rates, which are more consistent with the deflagration mode of acceleration. Separate work on gas-fed pulsed plasma thrusters (PPTs) by Ziemer, et al. identified two separate regimes of performance. The regime at higher mass bits (termed Mode I in that work) possessed relatively constant thrust efficiency (ratio of jet kinetic energy to input electrical energy) as a function of mass bit. In the second regime at very low mass bits (termed Mode II), the efficiency increased with decreasing mass bit. Work by Poehlmann et al. and by Sitaraman and Raja sought to understand the performance of the CHENG thruster and the Mode I / Mode II performance in PPTs by modeling the acceleration using the Hugoniot Relation, with the detonation and deflagration modes representing two distinct sets of solutions to the relevant conservation laws. These works studied the proposal that, depending upon the values of the various controllable parameters, the accelerator would operate in either the detonation or deflagration mode. In the present work, we propose a variation on the explanation for the differences in performance between the various pulsed plasma accelerators. Instead of treating the accelerator as if it were only operating in one mode or the other during a pulse, we model the initial stage of the discharge in all cases as an accelerating current sheet (detonation mode). If the current sheet reaches the exit of the accelerator before the discharge is completed, the acceleration mode transitions to the deflagration mode type found in the quasi-steady MPD thrusters. This modeling method is used to demonstrate that standard gas-fed pulsed plasma accelerators, the CHENG thruster, and the quasi-steady MPD accelerator are variations of the same device, with the overall acceleration of the plasma depending upon the behavior of the plasma discharge during initial transient phase and the relative lengths of the detonation and deflagration modes of operation.

Polzin, Kurt A.↗

Incompressible Navier-Stokes Computations for the Development of a Ventricular Assist Device

An incompressible flow analysis code, INS3D, has been applied to the development of a mechanical heart assist device. The solution method is based on the artificial compressibility approach and uses an implicit-upwind differencing scheme together with a Gauss-Seidel line relaxation method. The equations are solved in steadily rotating reference frames and the centrifugal and the Coriolis force terms are included as source terms. The resulting computational procedure is validated for liquid rocket engine analysis and applied subsequently to analyze a Ventricular Assist Device (VAD). A new design configuration is developed which includes an inducer upstream of the impeller main blades, and substantial improvement is observed in the performance of the VAD.

Kiris, Cetin↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

Characterization of Low Noise, Precision Voltage Reference REF5025-HT Under Extreme Temperatures

The performance of Texas Instruments precision voltage reference REF5025-HT was assessed under extreme temperatures. This low noise, 2.5 V output chip is suitable for use in high temperature down-hole drilling applications, but no data existed on its performance at cryogenic temperatures. The device was characterized in terms of output voltage and supply current at different input voltage levels as a function of temperature between +210 C and -190 C. Line and load regulation characteristics were also established at six load levels and at different temperatures. Restart capability at extreme temperatures and the effects of thermal cycling, covering the test temperature range, on its operation and stability were also investigated. Under no load condition, the voltage reference chip exhibited good stability in its output over the temperature range of -50 C to +200 C. Outside that temperature range, output voltage did change as temperature was changed. For example, at the extreme temperatures of +210 C and - 190 C, the output level dropped to 2.43 V and 2.32 V, respectively as compared to the nominal value of 2.5 V. At cryogenic test temperatures of -100 C and -150 C the output voltage dropped by about 20%. The quiescent supply current of the voltage reference varied slightly with temperature but remained close to its specified value. In terms of line regulation, the device exhibited excellent stability between -50 C and +150 C over the entire input voltage range and load levels. At the other test temperatures, however, while line regulation became poor at cryogenic temperatures of -100 C and below, it suffered slight degradation at the extreme high temperature but only at the high load level of 10 mA. The voltage reference also exhibited very good load regulation with temperature down to -100 C, but its output dropped sharply at +210 C only at the heavy load of 10 mA. The semiconductor chip was able restart at the extreme temperatures of -190 C and +210 C, and the limited thermal cycling did not influence its characteristics and had no impact on its packaging as no structural or physical damage was observed.

Patterson, Richard↗

Trap Passivation for Reducing On-Resistance and Saturation Voltage in Wafer-Bonded InGaAs-Channel/GaN-Drain Vertical FETs

High frequency and high power are the driving forces behind semiconductor transistor technology. However, conventional devices have the tradeoff of either being high speed or high breakdown—but not both. Wafer-bonded current aperture vertical electron transistors (BAVETs) help eliminate the tradeoff by combining a high-speed III-As channel to a high-breakdown III-N drift region. The device presented herein comprises of an InAlAs gate-barrier/InGaAs channel, wafer-bonded to an InGaN/GaN drift region, with the InGaAs/InGaN interface referred to as the wafer-bonded interface (WBI). The electronic behavior of WBIs is yet less known but necessary in realizing the potential of a BAVET. Herein, strong trap activity at the WBI is shown to be the cause of abnormally high saturation voltage ( V DS_SAT ) in BAVETs. The traps cause unintentional space charge (SC) region in the drain region of the device. This causes a drain resistance, a higher ON-resistance ( R ON ), and a higher V DS_SAT . Here, the challenge is overcome by hydrogen passivation of traps at WBI by using a p-doping for the InAlAs layer, which reduces the trap-charge concentration at the WBI. Consequently, the width of the SC region is reduced and a reduction in V DS_SAT is demonstrated, wherein it reduces from >12 to 5 V.

36 MATERIALS SCIENCE↗

Modular Apparatus and Method for Attaching Multiple Devices

A modular apparatus for attaching sensors and electronics is disclosed. The modular apparatus includes a square recess including a plurality of cavities and a reference cavity such that a pressure sensor can be connected to the modular apparatus. The modular apparatus also includes at least one voltage input hole and at least one voltage output hole operably connected to each of the plurality of cavities such that voltage can be applied to the pressure sensor and received from the pressure sensor.

Okojie, Robert S↗

Modular Apparatus and Method for Attaching Multiple Devices

A modular apparatus for attaching sensors and electronics is disclosed. The modular apparatus includes a square recess including a plurality of cavities and a reference cavity such that a pressure sensor can be connected to the modular apparatus. The modular apparatus also includes at least one voltage input hole and at least one voltage output hole operably connected to each of the plurality of cavities such that voltage can be applied to the pressure sensor and received from the pressure sensor.

Okojie, Robert S.↗

Interoperability Review of Wireless Hardware in Emergency Air-To-Ground Mesh Networks

The air-to-ground network has the goal of advancing the capabilities and versatility of communications in wildfire and emergency scenarios. To ensure compatibility and keep costs low for emergency services interoperability between hardware is an important step in development of the mesh network. For the purposes of this evaluation interoperability of hardware is described as the ability for hardware from different vendors to be interchangeable within the network with minimal initial setup and no functional change from an operator’s viewpoint. This report will also focus on the features and limitations in addition to the interoperability of the major wireless hardware systems core to the function of the proposed air-to-ground mesh network. The hardware systems involved are ADS-B receivers, 3GPP Sidelink devices, mesh radios, and commercial ISM band radios. For early testing the mesh radios will be in the 900 MHz frequency range using the DoodleLabs RM-1700-22W Mesh Rider Radio as the lab reference. This report will consider and categorize desirability of features, the amount of setup required before deployment, the effect on performance characteristics from nominal and maximum load, and the ability to interface with other vender devices.

Mesh Radio↗