Application of a Planar Doppler Velocimetry System to a High Reynolds Number Compressible Jet

A Planar Doppler Velocimetry (PDV) system has been constructed and used to investigate the instantaneous turbulent velocity structure of a round high-speed compressible air jet with a low-speed co-flow. The exit condition was Mach=0.85 at ambient pressure, yielding a Reynolds number of about 650,000 on diameter. The PDV system was installed at NASA Langley Research Center in the Small Anechoic Jet Facility (SAJF), a chamber in which both the acoustic and aerodynamic properties of jets can be studied. For this test, the goal was to gather data which can be used to relate the turbulence structure of the jet to the levels and character of the acoustic noise produced by the jet. The current PDV system can acquire single-velocity-component, single-shot, planar images (15ns exposures) at 30 Hz. For this paper, the primary data set consists of 240 frames of velocity data acquired with both the jet and the low-speed co-flow seeded with light-scattering articles. Thus, velocities could be measured everywhere in the jet shear layer, both in the jet fluid and in the entrained co-flow. Some data were also taken with only the jet flow seeded. These provided mixing concentration images along with the reduced velocity fields. Other images were taken with only the co-flow seeded. These produced unique quantitative images of high speed entrainment. Optical "laser speckle" noise is the largest source of random noise in pulsed PDV systems. Components for the PDV imaging system were specifically selected to minimize speckle noise. To reduce systematic velocity errors due to laser drift, a frequency monitoring reference leg with a temperature-tuned reference iodine cell, was employed. In the course of this study, a novel flow seeder was developed. It enabled continuously variable seeding of the flow with particles of Sheared Pyrogenic Amorphous Hydrophobic Silica (SPAHS). The seeder comprised a dry fluidized bed hopper and a supersonic nozzle "pickup." Shearing action in the pickup dispersed the seed material in an exceptionally fine cloud (approximately 0.3 micron). These particles followed the flow well, did not clump or cake on screens or model surfaces, and were not susceptible to evaporation. Because of the refractory nature of the particles, SPAHS seeding should also be applicable to anticipated future testing at high temperatures.

Smith, Michael W.↗

Signal processing for ION mobility spectrometers

Signal processing techniques for systems based upon Ion Mobility Spectrometry will be discussed in the light of 10 years of experience in the design of real-time IMS. Among the topics to be covered are compensation techniques for variations in the number density of the gas - the use of an internal standard (a reference peak) or pressure and temperature sensors. Sources of noise and methods for noise reduction will be discussed together with resolution limitations and the ability of deconvolution techniques to improve resolving power. The use of neural networks (either by themselves or as a component part of a processing system) will be reviewed.

Taylor, S.↗

Fluctuation–dissipation relation for a quantum Brownian oscillator in a parametrically squeezed thermal field

In this paper we study the nonequilibrium evolution of a quantum Brownian oscillator, modeling the internal degree of freedom of a harmonic atom or an Unruh–DeWitt detector, coupled to a nonequilibrium and nonstationary quantum field bath and inquire whether a fluctuation–dissipation relation (FDR) can exist after/if it approaches equilibration. This is a nontrivial issue because a squeezed field bath cannot reach equilibration and yet, as this work shows, the system oscillator indeed can, which is a necessary condition for FDRs. We discuss three different settings: (A) The bath field essentially remains in a squeezed thermal state throughout, whose squeeze parameter is a mode- and time-independent constant. This situation is often encountered in quantum optics and quantum thermodynamics. (B) The bath field is initially in a thermal state, but is subjected to a parametric process leading to mode- and time-dependent squeezing. This scenario is encountered in cosmology and dynamical Casimir effects. The squeezing in the bath in both types of processes will affect the oscillator’s nonequilibrium evolution. We show that at late times it approaches equilibration and this stationarity condition warrants the existence of a FDR. The trait of squeezing is marked by the oscillator’s effective equilibrium temperature, and the proportionality factor in the FDR is only related to the stationary component of the noise kernel of the bath field. Setting (C) is more subtle: A finite system–bath coupling strength can set the oscillator in a squeezed state even though the bath field is stationary and does not engage in any parametric process. The squeezing of the system in this case is in general time-dependent but becomes constant when the internal dynamics is fully relaxed. We begin with comments on the broad range of physical processes involving squeezed thermal baths and end with some remarks on the significance of FDRs in capturing the essence of quantum backreaction in nonequilibrium and stochastic systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

International Space Station USOS Crew Quarters Ventilation and Acoustic Design Implementation

The International Space Station (ISS) United States Operational Segment (USOS) has four permanent rack sized ISS Crew Quarters (CQ) providing a private crewmember space. The CQ uses Node 2 cabin air for ventilation/thermal cooling, as opposed to conditioned ducted air from the ISS Temperature Humidity Control System or the ISS fluid cooling loop connections. Consequently, CQ can only increase the air flow rate to reduce the temperature delta between the cabin and the CQ interior. However, increasing airflow causes increased acoustic noise so efficient airflow distribution is an important design parameter. The CQ utilized a two fan push-pull configuration to ensure fresh air at the crewmember s head position and reduce acoustic exposure. The CQ interior needs to be below Noise Curve 40 (NC-40). The CQ ventilation ducts are open to the significantly louder Node 2 cabin aisle way which required significantly acoustic mitigation controls. The design implementation of the CQ ventilation system and acoustic mitigation are very inter-related and require consideration of crew comfort balanced with use of interior habitable volume, accommodation of fan failures, and possible crew uses that impact ventilation and acoustic performance. This paper illustrates the types of model analysis, assumptions, vehicle interactions, and trade-offs required for CQ ventilation and acoustics. Additionally, on-orbit ventilation system performance and initial crew feedback is presented. This approach is applicable to any private enclosed space that the crew will occupy.

Broyan, James Lee, Jr.↗

Experimental evaluation of fluctuating density and radiated noise from a high temperature jet

An experimental investigation has been conducted to characterize the fluctuating density within a high-temperature (1100 K) subsonic jet and to characterize by the noise radiated to the surroundings. Cross correlations obtained by introducing time delay to the signals detected from spatially separated crossed laser beams set up as a Schlieren system were used to determine radial and axial distributions of the convection velocity of the moving noise sources (eddies). In addition, the autocorrelation of the fluctuating density was evaluated in the moving frame of reference of the eddies. Also, the autocorrelation of the radiated noise in the moving reference frame was evaluated from cross correlations by introducing time delay to the signals detected by spatially separated pairs of microphones. Radial distributions of the mean velocity were obtained from measurements of the stagnation temperature, and stagnation and static pressures with the use of probes.

Massier, P. F.↗

Anomalous Loss Reduction Below Two‐Level System Saturation in Aluminum Superconducting Resonators

Superconducting resonators are widely used in many applications such as qubit readout for quantum computing, and kinetic inductance detectors. These resonators are susceptible to numerous loss and noise mechanisms, especially the dissipation due to two-level systems (TLS) which become the dominant source of loss in the few-photon and low temperature regime. In this study, capacitively-coupled aluminum half-wavelength coplanar waveguide resonators are investigated. Surprisingly, the loss of the resonators is observed to decrease with a lowering temperature at low excitation powers and temperatures below the TLS saturation. This behavior is attributed to the reduction of the TLS resonant response bandwidth with decreasing temperature and power to below the detuning between the TLS and the resonant photon frequency in a discrete ensemble of TLS. When response bandwidths of TLS are smaller than their detunings from the resonance, the resonant response and thus the loss is reduced. At higher excitation powers, the loss follows a logarithmic power dependence, consistent with predictions from the generalized tunneling model (GTM). A model combining the discrete TLS ensemble with the GTM is proposed and matches the temperature and power dependence of the measured internal loss of the resonator with reasonable parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

System for measuring passenger reaction to transportation-vehicle vibration

Equipment is capable of measuring frequencies from 0 to 50 Hz and is portable, light, inexpensive, and easily adaptable to field operations. System could be used in situations where it is necessary to record simultaneously subject response to other types of physical measurement or stimuli, such as temperature, noise, or pressure.

Clevenson, S. A.↗

RF performance measurement of the DSS-14 70-meter antenna at C-band/L-band

The calibration of the 70-meter antenna at C-band (5.01 GHz) and L-band (1.668 GHz) is described. This calibration comes after a modification to an existing L-band feed to include the C-band frequencies. The test technique employs noise-adding radiometers and associated equipment running simultaneously at both frequencies. The test procedure is described including block diagrams, and results are presented for efficiency, system temperature, and pointing.

Gatti, M. S.↗

Evaluation of Turbulence-Model Performance in Jet Flows

The importance of reducing jet noise in both commercial and military aircraft applications has made jet acoustics a significant area of research. A technique for jet noise prediction commonly employed in practice is the MGB approach, based on the Lighthill acoustic analogy. This technique requires as aerodynamic input mean flow quantities and turbulence quantities like the kinetic energy and the dissipation. The purpose of the present paper is to assess existing capabilities for predicting these aerodynamic inputs. Two modern Navier-Stokes flow solvers, coupled with several modern turbulence models, are evaluated by comparison with experiment for their ability to predict mean flow properties in a supersonic jet plume. Potential weaknesses are identified for further investigation. Another comparison with similar intent is discussed by Barber et al. The ultimate goal of this research is to develop a reliable flow solver applicable to the low-noise, propulsion-efficient, nozzle exhaust systems being developed in NASA focused programs. These programs address a broad range of complex nozzle geometries operating in high temperature, compressible, flows. Seiner et al. previously discussed the jet configuration examined here. This convergent-divergent nozzle with an exit diameter of 3.6 inches was designed for an exhaust Mach number of 2.0 and a total temperature of 1680 F. The acoustic and aerodynamic data reported by Seiner et al. covered a range of jet total temperatures from 104 F to 2200 F at the fully-expanded nozzle pressure ratio. The aerodynamic data included centerline mean velocity and total temperature profiles. Computations were performed independently with two computational fluid dynamics (CFD) codes, ISAAC and PAB3D. Turbulence models employed include the k-epsilon model, the Gatski-Speziale algebraic-stress model and the Girimaji model, with and without the Sarkar compressibility correction. Centerline values of mean velocity and mean temperature are compared with experimental data.

Woodruff, S. L.↗

Antenna for Measuring Electric Fields Within the Inner Heliosphere

A document discusses concepts for the design of an antenna to be deployed from a spacecraft for measuring the ambient electric field associated with plasma waves at a location within 3 solar radii from the solar photosphere. The antenna must be long enough to extend beyond the photoelectron and plasma sheaths of the spacecraft (expected to be of the order of meters thick) and to enable measurements at frequencies from 20 Hz to 10 MHz without contamination by spacecraft electric-field noise. The antenna must, therefore, extend beyond the thermal protection system (TPS) of the main body of the spacecraft and must withstand solar heating to a temperature as high as 2,000 C while not conducting excessive heat to the interior of the spacecraft. The TPS would be conical and its axis would be pointed toward the Sun. The antenna would include monopole halves of dipoles that would be deployed from within the shadow of the TPS. The outer potion of each monopole would be composed of a carbon-carbon (C-C) composite surface exposed to direct sunlight (hot side) and a C-C side in shadow (cold side) with yttria-stabilized zirconia spacers in-between. The hot side cannot view the spacecraft bus, while the cold side can. The booms also can be tilted to minimize heat input to spacecraft bus. This design allows one to reduce heat input to the spacecraft bus to acceptable levels.

Sittler, Edward Charles↗

First Results From an Uncooled LWIR Polarimeter for Cubesat Deployment

A compact long-wave infrared (LWIR) channeled spectro-polarimeter (IRCSP) has been developed for integration into the NASA Earth Science Technology Office (ESTO) funded submm-wave and LWIR polarimeters project to measure the microphysical properties of cloud ice. Once deployed, the IRCSP will produce the first linear Stokes measurements ( S0 , S1 , S2 ) of upper-tropospheric cirrus clouds from 8.5 to 12.5 μm. For the first time, a compact, light-weight, and uncooled LWIR polarimeter with off-the-shelf thermal optical components is demonstrated. We report narrowband calibration measurements which quantify metrics of polarimetric system performance. The response of the system to linearly polarized light is shown to agree with both a Mueller matrix model and modulation function for narrowband calibration measurements with an R2 > 0.98 from 8 to 11 μm. The polarimetric efficiency is >0.8 from 8 to 11 μm for narrowband measurements indicating satisfactory performance of the polarization optics. Beyond 11 μm, the agreement is significantly reduced as thermal noise compounds with reduced detector response. Ultimately, the observed system performance is limited by the spectral response of the detector past 11 μm in addition to the thermal noise inherent for the measurements at room temperature.

LWIR↗

Improved fabrication techniques for infrared bolometers

Ion implantation and sputter metallization are used to produce ohmic electrical contacts to Ge:Ga chips. The method is shown to give a high yield of small monolithic bolometers with very little low-frequency noise. It is noted that when one of the chips is used as the thermometric element of a composite bolometer it must be bonded to a dielectric substrate. The thermal resistance of the conventional epoxy bond is measured and found to be undesirably large. A procedure for soldering the chip to a metallized portion of the substrate in such a way as to reduce this resistance is outlined. An evaluation is made of the contribution of the metal film absorber to the heat capacity of a composite bolometer. It is found that the heat capacity of a NiCr absorber at 1.3 K can dominate the bolometer performance. A Bi absorber possesses significantly lower heat capacity. A low-temperature blackbody calibrator is built to measure the optical responsivity of bolometers. A composite bolometer system with a throughput of approximately 0.1 sr sq cm is constructed using the new techniques. The noise in this bolometer is white above 2.5 Hz and is slightly below the value predicted by thermodynamic equilibrium theory.

Lange, A. E.↗

Positive- and negative-frequency noise from an ensemble of two-level fluctuators

The analysis of charge noise based on the Bloch-Redfield treatment of an ensemble of dissipative two-level fluctuators generally results in a violation of the fluctuation-dissipation theorem. The standard Markov approximation (when applied to the two-level fluctuators coupled to a bath) can be identified as the main origin of this failure. The resulting decoherence rates only involve the bath response at the fluctuator frequency, and thus completely neglect the effects of frequency broadening. A systematic and computationally convenient way to overcome this issue is to employ the spectator-qubit method: by coupling an auxiliary qubit to the two-level fluctuator ensemble, an analytical approximation for S(ω) fully consistent with the fluctuation-dissipation theorem can be obtained. We discuss the resulting characteristics of the noise which exhibits distinct behavior over several frequency ranges, including a 1/f to 1/f2 crossover with a T3 temperature dependence of the crossover frequency.

2-dimensional systems↗

In-Service Monitoring of Steam Pipe Systems at High Temperatures

An effective, in-service health monitoring system is needed to track water condensation in real time through the walls of steam pipes. The system is required to measure the height of the condensed water from outside the pipe, while operating at temperatures that are as high as 250 C. The system needs to account for the effects of water flow and cavitation. In addition, it is desired that the system does not require perforating the pipes and thereby reducing the structural integrity. Generally, steam pipes are used as part of the district heating system carrying steam from central power stations under the streets to heat, cool, or supply power to high-rise buildings and businesses. This system uses ultrasonic waves in pulse-echo and acquires reflected signal data. Via autocorrelation, it determines the water height while eliminating the effect of noise and multiple reflections from the wall of the pipe. The system performs nondestructive monitoring through the walls of steam pipes, and automatically measures the height of condensed water while operating at the high-temperature conditions of 250 C. For this purpose, the ultrasonic pulse-echo method is used where the time-of-flight of the wave reflections inside the water are measured, and it is multiplied by the wave velocity to determine the height. The pulse-echo test consists of emitting ultrasonic wave pulses from a piezoelectric transducer and receiving the reflections from the top and bottom of the condensed water. A single transducer is used as a transmitter as well as the receiver of the ultrasonic waves. To obtain high resolution, a broadband transducer is used and the frequency can be in the range of 2.25 to 10 MHz, providing sharp pulses in the time domain allowing for higher resolution in identifying the individual reflections.

Bar-Cohen, Yoseph↗

Denoising of imaginary time response functions with Hankel projections

Imaginary-time response functions of finite-temperature quantum systems are often obtained with methods that exhibit stochastic or systematic errors. Reducing these errors comes at a large computational cost—in quantum Monte Carlo simulations, the reduction of noise by a factor of two incurs a simulation cost of a factor of four. In this paper, we relate certain imaginary-time response functions to an inner product on the space of linear operators on Fock space. We then show that data with noise typically does not respect the positive definiteness of its associated Gramian. The Gramian has the structure of a Hankel matrix. As a method for denoising noisy data, we introduce an alternating projection algorithm that finds the closest positive definite Hankel matrix consistent with noisy data. We test our methodology at the example of fermion Green's functions for continuous-time quantum Monte Carlo data and show remarkable improvements of the error, reducing noise by a factor of up to 20 in practical examples. We argue that Hankel projections should be used whenever finite-temperature imaginary-time data of response functions with errors is analyzed, be it in the context of quantum Monte Carlo, quantum computing, or in approximate semianalytic methodologies. Published by the American Physical Society 2024

Yu, Yang (ORCID:0000000186178878)↗

Experimental evaluation of fluctuating density and radiated noise from a high-temperature jet

An experimental investigation has been conducted to characterize the fluctuating density within a high temperature (1100 K) subsonic jet and to characterize the noise radiated to the surroundings. Cross correlations obtained by introducing time delay to the signals detected from spatially separated crossed laser beams set up as a schlieren system were used to determine radial and axial distributions of the convection velocity of the moving noise sources (eddies). In addition, the autocorrelation of the fluctuating density was evaluated in the moving frame of reference of the eddies. Also, the autocorrelation of the radiated noise in the moving reference frame was evaluated from cross correlations by introducing time delay to the signals detected by spatially separated pairs of microphones. The radiated noise results are compared with Lighthill's theory and with the data of Lush. Radial distributions of the mean velocity were obtained from measurements of the stagnation temperature, and stagnation and static pressures with the use of probes.

Massier, P. F.↗

Application of a Physics-Based Stabilization Criterion to Flight System Thermal Testing

The theory shown here can provide thermal stability criteria based on physics and a goal steady state error rather than on an arbitrary "X% Q/mC(sub P)" method. The ability to accurately predict steady-state temperatures well before thermal balance is reached could be very useful during testing. This holds true for systems where components are changing temperature at different rates, although it works better for the components closest to the sink. However, the application to these test cases shows some significant limitations: This theory quickly falls apart if the thermal control system in question is tightly coupled to a large mass not accounted for in the calculations, so it is more useful in subsystem-level testing than full orbiter tests. Tight couplings to a fluctuating sink causes noise in the steady state temperature predictions.

Baker, Charles↗

Quantum Sensing using Geometrical Phase in Qubit-Oscillator Systems

We present a quantum sensing protocol for coupled qubit-oscillator systems that surpasses the standard quantum limit (SQL) by exploiting a geometrical phase. The signal is encoded in the geometrical phase that is proportional to the area enclosed in oscillator phase space. This area is amplified through squeezing, enabling sensitivities beyond the SQL. Our method is independent of oscillator's initial state, amenable to sensing with high-temperature or logical error-corrected states. The protocol shows robustness to qubit Markovian noise and preserves its state-independence, underscoring its practicality for next-generation quantum metrology. We demonstrate application to force sensing beyond the SQL in longitudinally coupled systems, and to high-precision measurements of couplings and pulse calibration surpassing SQL in dispersively coupled circuit quantum electrodynamics (cQED) architectures.

Suri, Nishchay [LBNL, Berkeley]↗