At least 343 records · Page 19

The hard x-ray nanotomography microscope at the advanced light source

Beamline 11.3.1 at the Advanced Light Source is a tender/hard (6–17 keV) x-ray bend magnet beamline recently re-purposed with a new full-field, nanoscale transmission x-ray microscope. The microscope is designed to image composite and porous materials possessing a submicrometer structure and compositional heterogeneity that determine materials’ performance and geologic behavior. The theoretical and achieved resolutions are 55 and <100 nm, respectively. The microscope is used in tandem with a <25 nm eccentricity rotation stage for high-resolution volume imaging using nanoscale computed tomography. The system also features a novel bipolar illumination condenser for the illumination of an ~100 μm spot of interest on the sample, followed by a phase-type zone plate magnifying objective of ~52 µm field of view and a phase detection ring. The zone plate serves as the system objective and magnifies the sample with projection onto an indirect x-ray detection system, consisting of a polished single crystal CsI(Tl) scintillator and a range of high-quality Plan Fluorite visible light objectives. The objectives project the final visible light image onto a water-cooled CMOS 2048 × 2048-pixel 2 detector. Here, in this paper, we will discuss the salient features of this instrument and describe early results from imaging the internal three-dimensional microstructure and nanostructure of target materials, including fiber-reinforced composites and geomaterials.

47 OTHER INSTRUMENTATION↗

Photon rings around warped black holes

Abstract The black hole photon ring is a prime target for upcoming space-based VLBI missions seeking to image the fine structure of astrophysical black holes. The classical Lyapunov exponents of the corresponding nearly bound null geodesics control the quasinormal ringing of a perturbed black hole as it settles back down to equilibrium, and they admit a holographic interpretation in terms of quantum Ruelle resonances of the microstate dual to the Kerr black hole. Recent work has identified a number of emergent symmetries related to the intricate self-similar structure of the photon ring. Here, we explore this web of interrelated phenomena in an exactly soluble example that arises as an approximation to the near-extremal Kerr black hole. The self-dual warped AdS 3 geometry has a photon ring as well as S L ( 2 , R ) isometries and an exactly calculable quasinormal mode (QNM) spectrum. We show explicitly that the geometric optics approximation reproduces the eikonal limit of the exact scalar QNM spectrum, as well as the approximate ‘near-ring’ wavefunctions. The S L ( 2 , R ) isometries are directly related to the emergent conformal symmetry of the photon ring in black hole images but are distinct from a recently discussed conformal symmetry of the eikonal QNM spectrum. The equivalence of the classical QNM spectrum—and thus the photon ring—to the quantum Ruelle resonances in the context of a spacetime with a putative holographic dual suggests that the photon ring of a warped black hole is indeed part of the black hole hologram.

79 ASTRONOMY AND ASTROPHYSICS↗

Time delay lens modelling challenge

ABSTRACT In recent years, breakthroughs in methods and data have enabled gravitational time delays to emerge as a very powerful tool to measure the Hubble constant H0. However, published state-of-the-art analyses require of order 1 yr of expert investigator time and up to a million hours of computing time per system. Furthermore, as precision improves, it is crucial to identify and mitigate systematic uncertainties. With this time delay lens modelling challenge, we aim to assess the level of precision and accuracy of the modelling techniques that are currently fast enough to handle of order 50 lenses, via the blind analysis of simulated data sets. The results in Rungs 1 and 2 show that methods that use only the point source positions tend to have lower precision ($10\!-\!20{{\ \rm per\ cent}}$) while remaining accurate. In Rung 2, the methods that exploit the full information of the imaging and kinematic data sets can recover H0 within the target accuracy (|A| < 2 per cent) and precision (<6 per cent per system), even in the presence of a poorly known point spread function and complex source morphology. A post-unblinding analysis of Rung 3 showed the numerical precision of the ray-traced cosmological simulations to be insufficient to test lens modelling methodology at the percent level, making the results difficult to interpret. A new challenge with improved simulations is needed to make further progress in the investigation of systematic uncertainties. For completeness, we present the Rung 3 results in an appendix and use them to discuss various approaches to mitigating against similar subtle data generation effects in future blind challenges.

Ding, X.↗

Iterative multi-task learning and inference from seismic images

Seismic interpretation aims to extract quantitative and interpretable attributes from a seismic image produced using some migration method to inform characteristics of a subsurface reservoir or target of interest. Current paradigms for computing seismic attributes mostly rely on single-task algorithms. We develop an iterative, multi-task machine learning method to learn and infer multiple attributes from a seismic image. This method is composed of two stages: a multi-task inference stage and a multi-modal, multi-task refinement stage. The basic mechanism of this method is that we train a multi-task inference neural network (NN) to estimate a set of attributes, including a relative geological time (RGT), a denoised higher-resolution (DHR) seismic image, and multiple fault attributes (including probability, dip, and strike), from a low-resolution, noisy seismic image; then we input the inferred attributes to a multi-task refinement NN to enhance the raw inference results iteratively. The two multi-task NNs are trained separately based on synthetic seismic images and associated attributes generated by a geological modeling algorithm. The software we intend to release is a PyTorch implementation of this multi-task learning method for both 2D and 3D cases along with scripts to run the training/validation. The algorithm and software can be a useful tool for automatic seismic interpretation.

Gao, Kai↗

Synthetic β-sheets mimicking fibrillar and oligomeric structures for evaluation of spectral X-ray scattering technique for biomarker quantification

Archetypical cross-β spines sharpen the boundary between functional and pathological proteins including β-amyloid, tau, α-synuclein and transthyretin are linked to many debilitating human neurodegenerative and non-neurodegenerative amyloidoses. An increased focus on development of pathogenic β-sheet specific fluid and imaging structural biomarkers and conformation-specific monoclonal antibodies in targeted therapies has been recently observed. Identification and quantification of pathogenic oligomers remain challenging for existing neuroimaging modalities. We propose two artificial β-sheets which can mimic the nanoscopic structural characteristics of pathogenic oligomers and fibrils for evaluating the performance of a label free, X-ray based biomarker detection and quantification technique. Highly similar structure with elliptical cross-section and parallel cross-β motif is observed among recombinant α-synuclein fibril, Aβ-42 fibril and artificial β-sheet fibrils. We then use these β-sheet models to assess the performance of spectral small angle X-ray scattering (sSAXS) technique for detecting β-sheet structures. sSAXS showed quantitatively accurate detection of antiparallel, cross-β artificial oligomers from a tissue mimicking environment and significant distinction between different oligomer packing densities such as diffuse and dense packings. The proposed synthetic β-sheet models mimicked the nanoscopic structural characteristics of β-sheets of fibrillar and oligomeric states of Aβ and α-synuclein based on the ATR-FTIR and SAXS data. The tunability of β-sheet proportions and shapes of structural motifs, and the low-cost of these β-sheet models can become useful test materials for evaluating β-sheet or amyloid specific biomarkers in a wide range of neurological diseases. By using the proposed synthetic β-sheet models, our study indicates that the sSAXS has potential to evaluate different stages of β-sheet-enriched structures including oligomers of pathogenic proteins.

59 BASIC BIOLOGICAL SCIENCES↗

DESI Massive Poststarburst Galaxies at z ~ 1.2 Have Compact Structures and Dense Cores

Poststarburst galaxies (PSBs) are young quiescent galaxies that have recently experienced a rapid decrease in star formation, allowing us to probe the fast-quenching period of galaxy evolution. In this work, we obtained Hubble Space Telescope (HST)/WFC3 F110W imaging to measure the sizes of 171 massive (log(M $\ast$ /M ⊙ ) ~ 11) spectroscopically identified PSBs at 1 < z 1.3 selected from the DESI Survey Validation luminous red galaxy sample. This statistical sample constitutes an order of magnitude increase from the ~20 PSBs with space-based imaging and deep spectroscopy. We perform structural fitting of the target galaxies with pysersic and compare them to quiescent and star-forming galaxies in the 3D-HST survey. We find that these PSBs are more compact than the general population of quiescent galaxies, lying systematically ~0.1 dex below the established size–mass relation. However, their central surface mass densities are similar to those of their quiescent counterparts (log(Σ 1kpc /(M ⊙ kpc -2 ))~10.1). These findings are easily reconciled by later ex situ growth via minor mergers or a slight progenitor bias. These PSBs are round in projection (b/a median ~ 0.8), suggesting that they are primarily spheroids, not disks, in 3D. We find no correlation between the time since quenching and light-weighted PSB sizes or central densities. This disfavors apparent structural growth due to the fading of centralized starbursts in this galaxy population. Instead, we posit that the fast quenching of massive galaxies at this epoch occurs preferentially in galaxies with preexisting compact structures.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation and confirmation of nine strong-lensing systems in Dark Energy Survey Year 1 data

ABSTRACT We describe the observation and confirmation of nine new strong gravitational lenses discovered in Year 1 data from the Dark Energy Survey (DES). We created candidate lists based on (i) galaxy group and cluster samples, and (ii) photometrically selected galaxy samples. We selected 46 candidates through visual inspection and then used the Gemini Multi-Object Spectrograph(GMOS) at the Gemini South telescope to acquire a spectroscopic follow-up of 21 of these candidates. Through an analysis of these spectroscopic follow-up data, we confirmed nine new lensing systems and rejected two candidates, and the analysis was inconclusive on 10 candidates. For each of the confirmed systems, our report measured spectroscopic properties, estimated source image–lens separations, and estimated enclosed masses as well. The sources that we targeted have an i-band surface brightness range of $i_{\rm SB} \sim 22\!-\!24\, {\rm mag}\,{\rm arcsec}^{-2}$ and a spectroscopic redshift range of zspec ∼ 0.8−2.6. The lens galaxies have a photometric redshift range of zlens ∼ 0.3−0.7. The lensing systems range in source image–lens separation from 2 to 9 arcsec and in enclosed mass from 1012 to 1013 M⊙.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Z-Target Radiography Postprocessing With A Deep Convolution Neural Network

Analyzing X-ray radiographs is crucial for understanding target behavior in Inertial Confinement Fusion (ICF) and High Energy Density (HED) platforms. However, the density of Magneto Raleigh Taylor (MRT) bands and limitations of target materials often obscure relevant spike growth and density information. To address this issue, machine learning postprocessing techniques can be applied to remove darkened regions in radiography images. In this study, a novel method is presented for removing MRT darkened regions from z-target radiographs using a convolutional neural network (CNN). The CNN, consisting of six layers, treats the darkened regions as noise and employs a mixed loss function and end-to-end frameworks to suppress them while preserving sharpness. The six-layer architecture is designed to effectively learn features when provided with a larger volume of learning space. Each layer is optimized using a mixed loss function that combines a standard loss pixel approach with a multi-scaled structural similarity index loss, which considers luminance, contrast, and structure in local neighborhoods. This approach is particularly beneficial for capturing the stochastic structure of MRT limbs. Due to the limited availability of experimental data, training is conducted using synthetic target radiography from 3D Alegra simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

Production and purification of 43Sc and 47Sc from enriched [46Ti]TiO2 and [50Ti]TiO2 targets

Abstract The radioscandium isotopes, 43 Sc and 47 Sc, compose a promising elementally matched theranostic pair that can be used for the development of imaging and therapeutic radiopharmaceuticals with identical structures. This study aimed to investigate the production of high radionuclidic purity 43 Sc from enriched [ 46 Ti]TiO 2 targets and 47 Sc from enriched [ 50 Ti]TiO 2 targets and establish a target recycling technique. Enriched [ 46 Ti]TiO 2 targets were irradiated with 18 MeV protons, and enriched [ 50 Ti]TiO 2 targets were bombarded with 24 MeV protons. 43 Sc and 47 Sc were purified using ion chromatography attaining recovery yields of 91.7 ± 7.4% and 89.9 ± 3.9%, respectively. The average radionuclidic purity for 43 Sc was 98.8 ± 0.3% and for 47 Sc 91.5 ± 0.6%, while the average recovery of enriched titanium target material was 96 ± 4.0%. The highest apparent molar activity for [ 43 Sc]Sc-DOTA was 23.2 GBq/µmol and 3.39 GBq/µmol for [ 47 Sc]Sc-DOTA. This work demonstrates the feasibility of using enriched recycled [ 46 Ti]TiO 2 and [ 50 Ti]TiO 2 targets to produce high purity 43 Sc and 47 Sc as an elementally matched theranostic isotope pair.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources

With its ability to efficiently probe low-Z materials, X-ray phase imaging methods have recently raised high interest in multiple fields from biology and medical applications to high energy density (HED) physics. Initially developed with synchrotron light and X-ray tubes, we present a novel grating based Talbot X-ray deflectometer (TXD) diagnostic that was coupled with laser-generated K-α X-ray sources. The multi-terawatt laser (I > 1 × 10 14 W cm -2 ) was used as a testbed for diagnostic development. It was found that X-ray source chromaticity plays an important role in TXD. Indeed, the broadband spectrum of laser-generated X-ray sources may strongly impact image quality and thus diagnostic performance. We qualified X-ray emission from different laser-produced sources and determined laser, target, and deflectometer parameters that optimize TXD performance. We present the first results of referenceless grating-based X-ray imaging at high-power laser facilities and discuss the implications of this new development in HED research.

47 OTHER INSTRUMENTATION↗

Multi-Scale 3D Imaging for Machine Learning Property Upscaling: Mt. Simon Sandstone Case Study

Petrographic properties of principal target reservoirs for carbon sequestration, such as the Mt. Simon Sandstone, are relevant to broad interest groups. The Mt. Simon Sandstone is a deep, saline, regionally extensive Cambrian sandstone, overlain by low permeability sealing formations, making it one of the viable geologic carbon storage reservoirs in the Midwestern US. Its thickness (exceeding 2400 ft in some localities), depth, and lateral extent, combined with high porosity and permeability make it a high-priority target of multiple ongoing geologic carbon sequestration efforts in the United States of America. The National Energy Technology Laboratory in Morgantown, West Virginia, has been engaged in characterization efforts of the Mt. Simon for over a decade, with a strong focus on Computed Tomographic data acquisition. Data generated during this period has been hitherto not accessible to the public. This archival effort focused on preservation of historical CT data and associated metadata, and facilitating their accessibility, culminating with the publication of the entire dataset on NETL’s Energy Data eXchange (EDX) and the associated Gill et. al (2024) paper.

Gill, Magdalena K.↗

Systems and methods of adaptive two-wavelength single-camera imaging thermography (ATSIT) for accurate and smart in-situ process temperature measurement during metal additive manufacturing

A two-wavelength, single-camera imaging thermography system for in-situ temperature measurement of a target, comprising: a target light path inlet conduit for receiving a target light beam reflected from the target; a beam splitter installed in a splitter housing at a distal end of the target light path conduit, wherein the beam splitter divides the target light beam into a first light beam and a second light beam; a first light path conduit emanating from the splitter housing comprising a first aperture iris installed within the first light path conduit for aligning the first light beam; a first band pass filter installed within the first light path conduit for regulating the first light beam to a first wavelength λ1 and an optional half waveplate installed within the first light path conduit to modulate a polarization ratio of the first light beam of λ1 wavelength; a second light path conduit emanating from the splitter housing comprising a second aperture iris installed within the second light path conduit for aligning the second light beam; a second band pass filter installed within the second light path conduit for regulating the second light beam to a second wavelength λ2; a junction housing, wherein distal ends of each of the first and second light path conduits are connected to the junction housing; a polarizing beam splitter installed in the junction housing, wherein the polarizing beam splitter reflects the first light beam of λ1 wavelength along the same path or a parallel path of the second light beam of λ2 wavelength that passes directly through the polarizing beam splitter unreflected to create a merged light beam comprising light of λ1 and λ2 wavelengths; and a light path outlet conduit connected to the junction for directing the merged beam to a high-speed camera for imaging.

Zhao, Xiayun↗

MeV x-ray production from a petawatt laser in the regime of a relativistically transparent preplasma, with applications to radiography

Bright sources of mega-electron volt (MeV) x-rays have many unique applications, including nuclear physics, radiation oncology, and imaging high areal density systems. High intensity lasers (>1018 W cm−2) incident on mm-thick metal targets can deliver MeV x-rays via the bremsstrahlung process, providing sources with ultrashort duration (∼ps) and small source size (∼100 μm). Here, we report on a reproducible regime of laser-driven MeV x-ray sources, where the x-ray dose can be further increased by 60% by coating the metal target with micrometers of plastic. High fidelity numerical simulations indicate that the interaction is a result of relativistic transparency in the preplasma. Though relativistic transparency is present in both cases, the greater sound speed and smaller ion inertia of the plastic target allow the laser to more deeply penetrate and couple more efficiently to electrons. Radiography with this system demonstrates a resolving power < 300 μm, important for imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A microCT-based platform to quantify drug targeting

Abstract Background Heterotopic ossification (HO) is a frequent and debilitating complication of traumatic musculoskeletal injuries and orthopedic procedures. Prophylactic dosing of botulinum toxin type A (BTxA) holds potential as a novel treatment option if accurately distributed throughout soft-tissue volumes where protection is clinically desired. We developed a high-resolution, microcomputed tomography (microCT)-based imaging strategy to assess drug distribution and validated this platform by quantifying distribution achieved via a prototype delivery system versus a single-bolus injection. Methods We injected an iodine-containing contrast agent (iodixanol 320 mg I/mL) into dissected rabbit musculature followed by microCT imaging and analysis. To contrast the performance of distributed versus bolus injections, a three-dimensional (3D) 64-cm 3 -printed soft-tissue holder was developed. A centered 2-cm 3 volume of interest (VOI) was targeted with a single-bolus injection or an equal volume distributed injection delivered via a 3D-printed prototype. VOI drug coverage was quantified as a percentage of the VOI volume that was < 1.0 mm from the injected fluid. Results The microCT-based approach enabled high-resolution quantification of injection distribution within soft tissue. The distributed dosing prototype provided significantly greater tissue coverage of the targeted VOI (72 ± 3%, mean ± standard deviation) when compared to an equal volume bolus dose (43 ± 5%, p = 0.031) while also enhancing the precision of injection targeting. Conclusions A microCT-based imaging technique precisely quantifies drug distribution within a soft-tissue VOI, providing a path to overcome a barrier for clinical translation of prophylactic inhibition of HO by BTxA. Relevance statement This platform will facilitate rapid optimization of injection parameters for clinical devices used to effectively and safely inhibit the formation of heterotopic ossification. Key points • MicroCT provides high-resolution quantification of soft-tissue drug distribution. • Distributed dosing is required to maximize soft-tissue drug coverage. • Imaging platform will enable rapid screening of 3D-printed drug distribution prototypes. Graphical Abstract

Ausk, Brandon J. (ORCID:0000000335338303)↗

X-ray imaging and radiation transport effects on cylindrical implosions

Magnetization of inertial confinement implosions is a promising means of improving their performance, owing to the potential reduction of energy losses within the target and mitigation of hydrodynamic instabilities. In particular, cylindrical implosions are useful for studying the influence of a magnetic field, thanks to their axial symmetry. In this work, we present experimental results from cylindrical implosions on the OMEGA-60 laser using a 40-beam, 14.5 kJ, 1.5 ns drive and an initial seed magnetic field of B 0 = 30 T along the axes of the targets, compared with reference results without an imposed B-field. Implosions were characterized using time-resolved x-ray imaging from two orthogonal lines of sight. We found that the data agree well with magnetohydrodynamic simulations, once radiation transport within the imploding plasma is considered. We show that for a correct interpretation of the data in these types of experiments, explicit radiation transport must be taken into account.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Semi-automatic image annotation using 3D LiDAR projections and depth camera data

Efficient image annotation is necessary to utilize deep learning object recognition neural networks in nuclear safeguards, such as for the detection and localization of target objects like nuclear material containers (NMCs). This capability can help automate the inventory accounting of different types of NMCs within nuclear storage facilities. The conventional manual annotation process is labor-intensive and time-consuming, hindering the rapid deployment of deep learning models for NMC identifications. This paper introduces a novel semi-automatic method for annotating 2D images of nuclear material containers (NMCs) by combining 3D light detection and ranging (LiDAR) data with color and depth camera images collected from a handheld scan system. The annotation pipeline involves an operator manually marking new target objects on a LiDAR-generated map, and projecting these 3D locations to images, thereby automatically creating annotations from the projections. The semi-automatic approach significantly reduces manual efforts and the expertise in image annotation that is required to perform the task, allowing deep learning models to be trained on-site within a few hours. The paper compares the performance of models trained on datasets annotated through various methods, including semi-automatic, manual, and commercial annotation services. The evaluation demonstrates that the semi-automatic annotation method achieves comparable or superior results, with a mean average precision (mAP) above 0.9, showcasing its efficiency in training object recognition models. Additionally, the paper explores the application of the proposed method to instance segmentation, achieving promising results in detecting multiple types of NMCs in various formations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗