Assessing the Effects of Data Compression in Simulations Using Physically Motivated Metrics

This paper examines whether lossy compression can be used effectively in physics simulations as a possible strategy to combat the expected data-movement bottleneck in future high performance computing architectures. We show that, for the codes and simulations we tested, compression levels of 3–5X can be applied without causing significant changes to important physical quantities. Rather than applying signal processing error metrics, we utilize physics-based metrics appropriate for each code to assess the impact of compression. We evaluate three different simulation codes: a Lagrangian shock-hydrodynamics code, an Eulerian higher-order hydrodynamics turbulence modeling code, and an Eulerian coupled laser-plasma interaction code. We compress relevant quantities after each time-step to approximate the effects of tightly coupled compression and study the compression rates to estimate memory and disk-bandwidth reduction. We find that the error characteristics of compression algorithms must be carefully considered in the context of the underlying physics being modeled.

Laney, Daniel↗

Influence of sun zenith angle on canopy clumping and the resulting impacts on photosynthesis

Addressing the impact of vegetation architecture on shortwave radiation transfer in land surface models is important for accurate weather forecasting, carbon budget estimates, and climate predictions. This paper investigates to what extent it is possible to retrieve structural parameters of two different parameterization schemes from direct transmittance derived from digital hemispherical photography and 3D radiative transfer modeling for two study sites with different vegetation canopy architectures. Neglecting the representation of 3D canopy structure in radiative transfer schemes leads to significant errors in shortwave radiation partitioning (up to 3.5 times more direct transmittance in the 3D model). Structural parameters, referred to as whole canopy ‘clumping indices’, were obtained in order to evaluate the impact of angular variation in clumping on shortwave radiation transfer. Impacts on photosynthesis were evaluated at site level with the UKESM land surface model, JULES. A comparison between flux tower derived and modeled photosynthesis indicates that considering zenith angular variations of structural parameters in the radiative transfer scheme of the UKESM land surface model significantly improves photosynthesis prediction in light limited ecosystems (from RMSE = 2.91 μmol CO 2 .m -2 .s -1 to RMSE = 1.51 μmol CO 2 .m -2 .s -1 , 48% smaller), typically with enhanced photosynthesis from bottom layers.

54 ENVIRONMENTAL SCIENCES↗

Performance Evaluation of an Offshore Wave Measurement Buoy in Monochromatic Waves

The accurate measurement of waves underpins marine energy resource characterization, device design, and project development. Datawell wave buoys are widely deployed and have long served as a trusted standard for wave measurements. We quantify the measurement performance, including wave elevation and energy flux estimation, of a Datawell DWR-MkIII buoy using prescribed monochromatic heave motions on a large-amplitude six-degree-of-freedom motion platform at the National Laboratory of the Rockies, assuming the buoy behaves as an ideal wave follower. Commanded motions were validated with an optical motion tracking system while buoy elevation and raw acceleration were recorded. Wave elevations were propagated to wave energy flux estimation using four methods, including one frequency-domain method and three time-domain methods. The Bayesian optimization was applied for design of experiments, and records from three test sites were also applied and evaluated in the present study. Results show two error regions within the nominal period range of 1.6 s to 30 s. For wave periods between 5 s and 25 s, the buoy provides accurate wave height measurements. For short periods less than 5 s, the 1.28 Hz sampling frequency induces sub-Nyquist artifacts that bias elevation and can drive maximum energy flux estimation errors above 100%. For long periods exceeding 25 s, the buoy reported elevation is underpredicted with error depending on period but relatively independent of wave height, with maximum wave height and wave energy flux errors reaching 64% and 87%, respectively. Furthermore, analysis of three field-derived cases shows that frequency-domain estimates at 1.28 Hz agree within 2% of the corresponding 100 Hz estimates, while larger method-dependent differences are observed for the Hilbert method.

16 TIDAL AND WAVE POWER↗

Monte Carlo MP2-F12 for Noncovalent Interactions: The C 60 Dimer

A scalable stochastic algorithm is presented that can evaluate explicitly correlated (F12) second-order many-body perturbation (MP2) energies of weak, noncovalent, intermolecular interactions. It first transforms the formulas of the MP2 and F12 energy differences into a short sum of high-dimensional integrals of Green’s functions in real space and imaginary time. Furthermore, these integrals are then evaluated by the Monte Carlo method augmented by parallel execution, redundant-walker convergence acceleration, direct-sampling autocorrelation elimination, and control-variate error reduction. By sharing electron-pair walkers across the supermolecule and its subsystems spanned by the joint basis set, the statistical uncertainty is reduced by one to 2 orders of magnitude in the MP2 binding energy corrected for the basis-set incompleteness and superposition errors. The method predicts the MP2-F12/aug-cc-pVDZ binding energy of 19.1 ± 4.0 kcal mol –1 for the C 60 dimer at the center distance of 9.748 Å.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beam-Based Diagnostics of Electric Guide Fields and Lattice Parameters for Run-1 of the Muon g-2 Storage Ring at Fermilab

A portion of the Muon g-2 Storage Ring electric system, which provides vertical beam focusing, exhibited an unexpected time dependence that produced a characteristic evolution of the stored beam during Run-1 of the Muon g-2 Experiment at Fermilab (E989). A method to reconstruct the Run-1 electric guide fields has been developed, which is based on a numerical model of the muon storage ring and optimization algorithms supported by COSY INFINITY. This method takes beam profile measurements from the Muon g-2 straw tracking detectors as input, and it produces a full reconstruction of the time-dependent fields. The fields can then be used for the reproduction of detailed beam tracking simulations and the calculation of ring lattice parameters for acceptance studies and systematic error evaluations.

43 PARTICLE ACCELERATORS↗

Highly Accurate Method for Real-Time Active Power Reserve Estimation for Utility-Scale Photovoltaic Power Plants

This paper applies a robust technique for determining the available power from a curtailed utility-scale photovoltaic (PV) power plant. The proposed technique does not require deploying any additional equipment or sensors and is based only on the addition of new control logic to the existing power plant controller. Also, the proposed method is universally applicable to PV plants with any type of smart inverters and PV modules. Accurate determination of available power is important for using curtailed PV generation as a resource for various types of active power controls, such as spinning reserves and primary and secondary frequency control. For PV plants to be able to maintain the desired regulation range, the plant controller must be able to estimate the available aggregate peak power that all the plant's inverters can produce at any point in time and ensure that the control error stays within the tolerance band at all times. In this paper, we explore a highly accurate control method that uses dedicated inverters within the plant as reference units and evaluates the available aggregate peak power for the whole plant under different cloud variability conditions.

14 SOLAR ENERGY↗

High-Resolution Regional Wave Hindcast for Hawaii

This report summarizes modeling efforts for hindcasting of wave climate within the exclusive economic zone (EEZ) around the state of Hawaii. Specifically, the report provides detailed description of model mesh development, sensitivity analysis of the configuration of model parameters, data used for model forcing and validation, model skill assessment, and model outputs for resource characterization. The unstructured, nested-grid modeling approach incorporates a regional high-resolution SWAN (Simulating WAves Nearshore) model within the global-regional WAVEWATCH III® (WW3) wave model. The models were configured to comply with the International Electrotechnical Commission (IEC) Technical Standards for wave energy resource characterization. The SWAN model domain covers the entire EEZ with a spatial resolution of approximately 300 m in the nearshore region. Two levels of WW3 nested grids, from 0.5 arc-degree at global to 7.5 arc-minute at regional scale, were used to provide boundary conditions that drive the high-resolution nearshore SWAN model. The WW3 and SWAN models were forced by 0.5 arc-degree Climate Forecast System Reanalysis wind and 5 km regional Weather Research and Forecasting wind, respectively. Wave resource and bulk wave parameters were simulated for a 32-year period from 1979 to 2010, and were subsequently validated using wave buoy data within the model domain. Model performance was evaluated using a set of error statistics. Overall, the model shows good skills in reproducing the wave climate in the Hawaii EEZ in both spatial and temporal domains. Comparisons of time series and scatter plots for the six IEC resource parameters and the associated error statistics tables, and horizontal two-dimensional plots of annually averaged and monthly averaged IEC parameters are provided.

16 TIDAL AND WAVE POWER↗

Evaluating pulse-shaping capabilities of next-generation pulsed power architectures

This project evaluated the pulse shaping capabilities of next-generation pulsed power (NGPP) architectures. NGPP architectures share several common attributes including multiple independent pulse-generation lines, a radial water-insulated impedance transformer, and a central vacuum insulated load region. A multi-module circuit model was developed, incorporating independent pulse-generation lines and a 2-D transmission line mesh of the radial impedance transformer to assess the effects of azimuthal asymmetry in pulse-shaped experiments. Circuit model simulations demonstrated that NGPP architectures are able to produce the the desired current pulse shapes for exemplar NGPP experiments. Additionally, the project explored automated methods for experiment design, including derivative -ree optimization and machine learning. Pulse-shaped experiments require designers to determine machine parameters that reliably produce the desired current pulse at the load, a process that typically relies on expert knowledge and iterative adjustments using the Z circuit model. Given the increased complexity of NGPP systems, this manual approach may be impractical. While the evaluated methods do not eliminate the need for manual iteration, they can reduce the time required for experiment design. Derivative-free optimization automates much of the trial-and-error process, providing a close starting point for manual adjustments or making small modifications to near-final designs. Meanwhile, deep neural network methods can generate a good qualitative match to the desired current pulse in under one second without requiring circuit model simulations.

42 ENGINEERING↗

An algorithm for control system design via parameter optimization

An algorithm for design via parameter optimization has been developed for linear-time-invariant control systems based on the model reference adaptive control concept. A cost functional is defined to evaluate the system response relative to nominal, which involves in general the error between the system and nominal response, its derivatives and the control signals. A program for the practical implementation of this algorithm has been developed, with the computational scheme for the evaluation of the performance index based on Lyapunov's theorem for stability of linear invariant systems.

Sinha, P. K.↗

Reconstruction errors in digital-to-analog conversion.

Error could theoretically be found as a function of time, midway between any two arbitrarily placed sample points. However, the analysis and the result would be difficult to use. As an alternative, worst-case instantaneous errors can be evaluated near the base-line crossing and at the peak of the analog signal. Location of sample points affects the error values obtained, but use of the points provides a means of comparing different reconstruction techniques. Zero-order conversion is discussed together with first-order conversion, second-order conversion, and third-order conversion.

Dotson, W. P., Jr.↗

Simulation Test Of Descent Advisor

Report describes piloted-simulation test of Descent Advisor (DA), subsystem of larger automation system being developed to assist human air-traffic controllers and pilots. Focuses on results of piloted simulation, in which airline crews executed controller-issued descent advisories along standard curved-path arrival routes. Crews able to achieve arrival-time precision of plus or minus 20 seconds at metering fix. Analysis of errors generated in turns resulted in further enhancements of algorithm to increase accuracies of its predicted trajectories. Evaluations by pilots indicate general support for DA concept and provide specific recommendations for improvement.

Davis, Thomas J.↗

Development of an unstructured solution adaptive method for the quasi-three-dimensional Euler and Navier-Stokes equations

A general solution adaptive scheme based on a remeshing technique is developed for solving the two-dimensional and quasi-three-dimensional Euler and Favre-averaged Navier-Stokes equations. The numerical scheme is formulated on an unstructured triangular mesh utilizing an edge-based pointer system which defines the edge connectivity of the mesh structure. Jameson's four-stage hybrid Runge-Kutta scheme is used to march the solution in time. The convergence rate is enhanced through the use of local time stepping and implicit residual averaging. As the solution evolves, the mesh is regenerated adaptively using flow field information. Mesh adaptation parameters are evaluated such that an estimated local numerical error is equally distributed over the whole domain. For inviscid flows, the present approach generates a complete unstructured triangular mesh using the advancing front method. For turbulent flows, the approach combines a local highly stretched structured triangular mesh in the boundary layer region with an unstructured mesh in the remaining regions to efficiently resolve the important flow features. One-equation and two-equation turbulence models are incorporated into the present unstructured approach. Results are presented for a wide range of flow problems including two-dimensional multi-element airfoils, two-dimensional cascades, and quasi-three-dimensional cascades. This approach is shown to gain flow resolution in the refined regions while achieving a great reduction in the computational effort and storage requirements since solution points are not wasted in regions where they are not required.

Jiang, Yi-Tsann↗

Development of an unstructured solution adaptive method for the quasi-three-dimensional Euler and Navier-Stokes equations

A general solution adaptive scheme-based on a remeshing technique is developed for solving the two-dimensional and quasi-three-dimensional Euler and Favre-averaged Navier-Stokes equations. The numerical scheme is formulated on an unstructured triangular mesh utilizing an edge-based pointer system which defines the edge connectivity of the mesh structure. Jameson's four-stage hybrid Runge-Kutta scheme is used to march the solution in time. The convergence rate is enhanced through the use of local time stepping and implicit residual averaging. As the solution evolves, the mesh is regenerated adaptively using flow field information. Mesh adaptation parameters are evaluated such that an estimated local numerical error is equally distributed over the whole domain. For inviscid flows, the present approach generates a complete unstructured triangular mesh using the advancing front method. For turbulent flows, the approach combines a local highly stretched structured triangular mesh in the boundary layer region with an unstructured mesh in the remaining regions to efficiently resolve the important flow features. One-equation and two-equation turbulence models are incorporated into the present unstructured approach. Results are presented for a wide range of flow problems including two-dimensional multi-element airfoils, two-dimensional cascades, and quasi-three-dimensional cascades. This approach is shown to gain flow resolution in the refined regions while achieving a great reduction in the computational effort and storage requirements since solution points are not wasted in regions where they are not required.

Jiang, Yi-Tsann↗

Highly Accurate Method for Real-Time Active Power Reserve Estimation for Utility-Scale PV Power Plants: Preprint

This paper applies a robust technique for determining the available power reserve from a curtailed utility-scale photovoltaic (PV) power plant. The proposed technique does not require deploying any additional equipment or sensors and is based only on the addition of new control logic to the existing power plant controller. Also, the proposed method is universally applicable to PV plants with any type of smart inverters and PV modules. Accurate determination of available power is important for using curtailed PV generation as a resource for various types of active power controls, such as spinning reserves and primary and secondary frequency control. For PV plants to be able to maintain the desired regulation range, the plant controller must be able to estimate the available aggregate peak power that all the plant's inverters can produce at any point in time and ensure that the control error stays within the tolerance band at all times. In this paper, we explore a highly accurate control method that uses dedicated inverters within the plant as reference units and evaluates the available aggregate peak power for the whole plant under different cloud variability conditions.

14 SOLAR ENERGY↗

SU-E-J-123: Targeting Accuracy of Image-Guided Radiosurgery for Intracranial Lesions

Purpose: To evaluate the setup accuracies of image-guided intracranial radiosurgery across several different linear accelerator platforms. Methods: A CT scan with a slice thickness of 1.0 mm was acquired of a Rando head phantom (The Phantom Laboratory) in a U-frame mask (BrainLAB AG). The phantom had three embedded BBs, simulating a central, left, and anterior lesion. The phantom was setup with each BB placed at the radiation isocenter under image guidance. Four different setup procedures were investigated: (1) NTX-ExacTrac: 6 degree-of-freedom (6D) correction on a Novalis Tx (BrainLAB AG) with ExacTrac localization (BrainLAB AG); (2) NTX-CBCT: 4D correction on the Novalis Tx with cone-beam computed tomography (CBCT); (3) TrueBeam-CBCT: 4D correction on a TrueBeam (Varian) with CBCT; (4) Edge-CBCT: 6D correction on an Edge (Varian) with CBCT. The experiment was repeated 5 times with different initial setup error at each BB location on each platform, and the mean (μ) and one standard deviation (σ) of the residual error was compared.The congruence between radiation and imaging isocenters on each platform was evaluated by acquiring Winston Lutz (WL) images of a WL jig followed by imaging using ExacTrac or CBCT. The difference in coordinates of the jig relative to radiation and imaging isocenters was then recorded. Results: Averaged over all three BB locations, the residual vector setup errors (μ±σ) of the phantom in mm were 0.6±0.2, 1.0±0.5, 0.2±0.1, and 0.3±0.1 on NTX-ExacTrac, NTX-CBCT, TrueBeam-CBCT, and Edge-CBCT, with their ranges in mm being 0.4∼1.1, 0.4∼1.9, 0.1∼0.5, and 0.2∼0.6, respectively. And imaging isocenter was found stable relative to radiation isocenter, with the congruence to radiation isocenter in mm being 0.6±0.1, 0.7±0.1, 0.3±0.1, 0.2±0.1, respectively, on the four systems in the same order. Conclusion: Millimeter accuracy can be achieved with image-guided radiosurgery for intracranial lesions based on this set of experiments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Descent Advisor Preliminary Field Test

A field test of the Descent Advisor (DA) automation tool was conducted at the Denver Air Route Traffic Control Center in September 1994. DA is being developed to assist Center controllers in the efficient management and control of arrival traffic. DA generates advisories, based on trajectory predictions, to achieve accurate meter-fix arrival times in a fuel efficient manner while assisting the controller with the prediction and resolution of potential conflicts. The test objectives were: (1) to evaluate the accuracy of DA trajectory predictions for conventional and flight-management system equipped jet transports, (2) to identify significant sources of trajectory prediction error, and (3) to investigate procedural and training issues (both air and ground) associated with DA operations. Various commercial aircraft (97 flights total) and a Boeing 737-100 research aircraft participated in the test. Preliminary results from the primary test set of 24 commercial flights indicate a mean DA arrival time prediction error of 2.4 seconds late with a standard deviation of 13.1 seconds. This paper describes the field test and presents preliminary results for the commercial flights.

Green, Steven M.↗

Transformer Neural Networks with Spatiotemporal Attention for Predictive Control and Optimization of Industrial Processes

In the context of real-time optimization and model predictive control of industrial systems, machine learning, and neural networks represent cutting-edge tools that hold promise for enhancing dynamic modeling. This work presents a novel transformer neural network architecture for real-time optimization and model predictive control. This network design includes a modified attention mechanism inspired by positional embedding attention from vision transformers and task-specific modifications to the input-output structure of the transformer’s decoder stack. Experiments were conducted using data from a 450 MW coal-fired power plant to evaluate this approach's effectiveness. The transformer neural network was compared with conventional recurrent models, including GRU and LSTM. The transformer exhibited a 6% increase in the R-squared (R2) value of predictions and an 83% reduction in mean squared error (MSE). Computation time was also reduced by 84% compared to conventional recurrent models.

Gallup, Ethan R.↗

Simulated fault injection - A methodology to evaluate fault tolerant microprocessor architectures

A simulation-based fault-injection method for validating fault-tolerant microprocessor architectures is described. The approach uses mixed-mode simulation (electrical/logic analysis), and injects transient errors in run-time to assess the resulting fault impact. As an example, a fault-tolerant architecture which models the digital aspects of a dual-channel real-time jet-engine controller is used. The level of effectiveness of the dual configuration with respect to single and multiple transients is measured. The results indicate 100 percent coverage of single transients. Approximately 12 percent of the multiple transients affect both channels; none result in controller failure since two additional levels of redundancy exist.