Site-Selective Real-Time Observation of Bimolecular Electron Transfer in a Photocatalytic System Using L-Edge X-Ray Absorption Spectroscopy

Here, time-resolved X-ray absorption spectroscopy has been utilized to monitor the bimolecular electron transfer in a photocatalytic water splitting system. This has been possible by uniting the local probe and element specific character of X-ray transitions with insights from high-level ab initio calculations. The specific target has been a heteroleptic [Ir III (ppy) 2 (bpy)] + photosensitizer, in combination with triethylamine as a sacrificial reductant and Fe 3 (CO) 12 as a water reduction catalyst. The relevant molecular transitions have been characterized via high-resolution Ir L-edge X-ray absorption spectroscopy on the picosecond time scale and restricted active space self-consistent field calculations. The presented methods and results will enhance our understanding of functionally relevant bimolecular electron transfer reactions and thus will pave the road to rational optimization of photocatalytic performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polarization-resolved core exciton dynamics in LiF using attosecond transient absorption spectroscopy

The ability to control absorption by modifying the polarization of light presents an exciting opportunity to experimentally determine the orbital alignment of absorption features. Here, attosecond extreme ultraviolet (XUV) transient absorption spectroscopy is used to investigate the polarization dependence of core exciton dynamics in LiF thin films at the Li + K edge. XUV pulses excite electrons from the Li 1s core level into the conduction band, allowing for the formation of a p-orbital-like core exciton, aligned along the XUV light polarization axis. A sub-5 fs near-infrared (NIR) probe pulse then arrives at variable time delays, perturbing the XUV-excited states and allowing the coherence decay of the core exciton to be mapped. The coherence lifetimes are found to be ≈ 2.4 ± 0.4 fs, which is attributed to a phonon-mediated dephasing mechanism as in previous core exciton studies. The differential absorption features are also shown to be sensitive to the relative polarization of the XUV and NIR fields. The parallel NIR probe induces couplings between the initial XUV-excited p-like bright exciton and s-like dark excitons. When crossed pump and probe polarizations are used, the coupling between the bright and dark states is no longer dipole-allowed, and the transient absorption signal associated with the coupling is suppressed by approximately 90%. This interpretation is supported by simulations of a few-level model system, as well as analysis of the calculated band structure. Here, the results indicate that laser polarization can serve as a powerful experimental tool for exploring the orbital alignment of core excitonic states in solid-state materials.

Attosecond laser spectroscopy↗

Direct Observation of Plasma-Stimulated Activation of Surface Species Using Multimodal In Situ/Operando Spectroscopy Combining Polarization-Modulation Infrared Reflection-Absorption Spectroscopy, Optical Emission Spectroscopy, and Mass Spectrometry

Nonthermal plasmas (NTPs) produce reactive chemical environments, including electrons, ions, radicals, and vibrationally excited molecules, that can drive chemistry at temperatures at which such species are thermally inaccessible. There has been growing interest in the integration of conventional catalysis with reactive NTPs to promote novel chemical transformations. Unveiling the full potential of plasma-catalytic processes requires a comprehensive understanding of plasma-catalytic synergies, including characterization of plasma-catalytic surface interactions. In this work, we report on a newly designed multimodal spectroscopic instrument combining polarization-modulation infrared reflection-absorption spectroscopy (PM-IRAS), mass spectrometry, and optical emission spectroscopy (OES) for the investigation of plasma–surface interactions such as those found in plasma catalysis. In particular, this tool has been utilized to correlate plasma-phase chemistry with both surface chemistry and gas-phase products in situ (1) during the deposition of carbonaceous surface species via NTP-promoted nonoxidative coupling of methane and (2) during subsequent activation of surface deposits with an atmospheric pressure and temperature argon plasma jet on both nickel (Ni) and silicon dioxide (SiO 2 ) surfaces. For the first time, the activation of carbonaceous surface species by a NTP on Ni and SiO 2 surfaces to form hydrogen gas and C 2 hydrocarbons was directly observed, where both PM-IRAS and OES measurements suggest that they may form through different pathways. Furthermore, this unique tool for studying plasma–surface interactions could enable more rational design of plasma-stimulated catalytic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UV laser long-path absorption spectroscopy

Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive absorption measurements some specific problems of those detectors have to be solved experimentally (i.e. fixed pattern noise, dark signal noise, nonuniform efficiency of individual elements, spatial sensitivity variations). In order to improve the low spatial resolution we performed laboratory studies using a multiple reflection cell to convert the long path technique to a real in situ point measurement. Under the conditions of field experiments in Julich residual absorbance signals at present are about 1.5x10(exp -4) corresponding to an OH detection sensitivity of 2x10(exp 6) OH/cm(exp 3) using a light path of 5.8 km. Total integration times for one measurement point vary between a few minutes and an hour.

Dorn, Hans-Peter↗

Electron thermalization and relaxation in laser-heated nickel by few-femtosecond core-level transient absorption spectroscopy

Direct measurements of photoexcited carrier dynamics in nickel are made using few-femtosecond extreme ultraviolet (XUV) transient absorption spectroscopy at the nickel M 2,3 edge. It is observed that the core-level absorption line shape of photoexcited nickel can be described by a Gaussian broadening (σ) and a red shift (ω s ) of the ground-state absorption spectrum. Theory predicts and the experimental results verify that after initial rapid carrier thermalization, the electron temperature increase (ΔT ) is linearly proportional to the Gaussian broadening factor σ, providing quantitative real-time tracking of the relaxation of the electron temperature. Measurements reveal an electron cooling time for 50 nm thick polycrystalline nickel films of 640 ± 80 fs. With hot thermalized carriers, the spectral red shift exhibits a power-law relationship with the change in electron temperature of ω s ∝ ΔT 1.5 . Rapid electron thermalization via carrier-carrier scattering accompanies and follows the nominal 4-fs photoexcitation pulse until the carriers reach a quasithermal equilibrium. Entwined with a <6 fs instrument response function, carrier thermalization times ranging from 34 fs to 13 fs are estimated from experimental data acquired at different pump fluences and it is observed that the electron thermalization time decreases with increasing pump fluence. Here, the study provides an initial example of measuring electron temperature and thermalization in metals in real time with XUV light, and it lays a foundation for further investigation of photoinduced phase transitions and carrier transport in metals with core-level absorption spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of launch conditions for Spacelab satisfying the constraints of an absorption spectroscopy project

The conditions for absorption spectroscopy of the homosphere between 20 and 100 km from a space platform such as Spacelab are considered. Using nominal orbital elements, and taking launch data and time as parameters of the problem, formula were established that give the data necessary for determining the flight plan. The geographical coordinates of the tangential points of the solar illumination boundaries were also calculated. It is shown that the latitude coverage of the observation is closely related to launch conditions. Expressions for the pointing angles referred to an instantaneous terrestrial trihedron are given. These angular elements are needed to determine the real pointing angles in a reference system linked to Spacelab.

Vercheval, J.↗

In situ monitoring of lanthanide reactions with oxide species via combined absorption spectroscopy and electrochemical methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form various insoluble oxide and oxychloride species with uranium and fission products. This work demonstrates real-time concentration monitoring of two trivalent lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. A combination of high-temperature absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled in the range of 0.001 M to 0.5 M by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides (LnOCl) or mixtures of oxychlorides and oxides (Ln2O3). However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with square wave voltammetry (SWV). Estimated reaction rates and extent of Pr3+ removal from solution as monitored by SWV agreed to within ~10% of the results found from absorption spectroscopy monitoring. This demonstrates that simultaneous electrochemical testing complements and expands the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Digging deeper: Buried layers and interfaces studied by modified total electron yield and soft x-ray absorption spectroscopy

We report on the soft x-ray absorption spectroscopy investigation of thin film capacitors using a modified total electron yield detection mode. This mode utilizes two ammeters instead of one as commonly employed in the classical total electron yield scheme to measure photocurrents of devices under soft x-ray irradiation. The advantage of this configuration over the surface sensitive classical total electron yield mode is that it can provide information from buried layers and interfaces up to a thickness equal to the penetration depth of soft x-rays. The method can be easily adapted to existing synchrotron end stations. We investigate dielectric capacitors with dissimilar electrodes to assess the feasibility of the modified total electron yield method. Furthermore, in operando soft x-ray absorption spectroscopy measurements are performed on ferroelectric capacitors under bias and using two ammeters. The experimental results are discussed in terms of the external and internal photoemission processes and their distribution in thin film capacitors under an external bias condition. The proposed detection method opens the way to perform electronic and chemical state analyses of the buried interfaces and layers in various devices like multiferroic tunnel junctions, memristive devices, etc., during operation under an applied bias.

Kröger, E.↗

In situ Monitoring of Lanthanide Reactions with Oxide Species via Combined Absorption Spectroscopy and Electrochemical Methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form insoluble oxide and oxychloride species with fission products. This work demonstrates real-time concentration monitoring of two lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. Combined absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides or mixtures of oxychlorides and oxides. However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with square wave voltammetry (SWV). Reaction rates and extent of Pr3+ removal from solution as monitored by SWV agreed closely with results found from spectroscopic monitoring. This demonstrates that simultaneous electrochemical testing complements the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

absorption spectroscopy↗

In situ monitoring of lanthanide reactions with oxide species via combined absorption spectroscopy and electrochemical methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form insoluble oxide and oxychloride species with fission products. This work demonstrates real-time concentration monitoring of two lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. Combined absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides or mixtures of oxychlorides and oxides. However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with cyclic voltammetry (CV). Reaction rates and extent of Pr3+ removal from solution as monitored by CV agreed closely with results found from spectroscopic monitoring. This demonstrates that simultaneous electrochemical testing complements the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sulfur Kβ X-ray emission spectroscopy: comparison with sulfur K-edge X-ray absorption spectroscopy for speciation of organosulfur compounds

Until recently, sulfur was known as a “spectroscopically silent” element because of a paucity of convenient spectroscopic probes suitable for in situ chemical speciation. In recent years the technique of sulfur K-edge X-ray absorption spectroscopy (XAS) has been used extensively in sulfur speciation in a variety of different fields. With an initial focus on reduced forms of organic sulfur, we have explored a complementary X-ray based spectroscopy – sulfur Kβ X-ray emission spectroscopy (XES) – as a potential analytical tool for sulfur speciation in complex samples. In this work, we compare and contrast the sensitivity of sulfur Kβ XES with that of sulfur K-edge XAS, and find differing sensitivities for the two techniques. In some cases an approach involving both sulfur K-edge XAS and sulfur Kβ XES may be a powerful combination for deducing sulfur speciation in samples containing complex mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupled valence carrier and core-exciton dynamics in WS 2 probed by few-femtosecond extreme ultraviolet transient absorption spectroscopy

Few-femtosecond extreme ultraviolet (XUV) transient absorption spectroscopy, performed with optical 500-1000 nm supercontinuum and broadband XUV pulses (30-50 eV), simultaneously probes dynamics of photoexcited carriers in WS$_{2}$ at the W O$_3$ edge (37-45 eV) and carrier-induced modifications of core-exciton absorption at the W N$_{6,7}$ edge (32-37 eV). Access to continuous core-to-conduction band absorption features and discrete core-exciton transitions in the same XUV spectral region in a semiconductor provides a novel means to investigate the effect of carrier excitation on core-exciton dynamics. The core-level transient absorption spectra, measured with either pulse arriving first to explore both core-level and valence carrier dynamics, reveal that core-exciton transitions are strongly influenced by the photoexcited carriers. A $1.2\pm0.3$ ps hole-phonon relaxation time and a $3.1\pm0.4$ ps carrier recombination time are extracted from the XUV transient absorption spectra from the core-to-conduction band transitions at the W O$_{3}$ edge. Global fitting of the transient absorption signal at the W N$_{6,7}$ edge yields $\sim 10$ fs coherence lifetimes of core-exciton states and reveals that the photoexcited carriers, which alter the electronic screening and band filling, are the dominant contributor to the spectral modifications of core-excitons and direct field-induced changes play a minor role. This work provides a first look at the modulations of core-exciton states by photoexcited carriers and advances our understanding of carrier dynamics in metal dichalcogenides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The electrode–electrolyte interface of Cu via modulation excitation X-ray absorption spectroscopy

The development and application of modulation excitation X-ray absorption spectroscopy with sub-second resolution and better than 0.02% detection sensitivity unveils the kinetics of the anodic oxidation of Cu in bicarbonate electrolytes. Accessing the electrode–electrolyte interface under operating conditions and capturing time-resolved kinetics remain challenging in electrochemical studies. Copper's interfacial oxidation dynamics remain unclear despite extensive research. Modulation excitation X-ray absorption spectroscopy (ME-XAS) was used to probe Cu in 100 mM KHCO 3 with sub-second sensitivity, revealing that hydroxide forms 30 ± 10 ms before the appearance of Cu 2 O at positive potentials (0 to 0.5 V vs. RHE) near open-circuit conditions. From −0.4 to 0.8 V vs. RHE, hydroxide coverage reaches 49%, accompanied by a balanced presence of Cu( i ) and Cu( ii ) oxides. These insights into Cu interfacial redox behavior under intermittent renewable energy operation—relevant to CO 2 electrolyzer durability—enhance our fundamental understanding of electrochemical interfaces.

Garcia-Esparza, Angel T↗

Interfacial properties in energy storage systems studied by soft x-ray absorption spectroscopy and resonant inelastic x-ray scattering

Interfacial behaviors and properties play critical roles in determining key practical parameters of electrochemical energy storage systems, such as lithium-ion and sodium-ion batteries. Soft x-ray spectroscopy features shallow penetration depth and demonstrates inherent surface sensitivity to characterize the interfacial behavior with elemental and chemical sensitivities. Here, we present a brief survey of modern synchrotron-based soft x-ray spectroscopy of the interface in electrochemical energy storage systems. The technical focus includes core-level spectroscopy of conventional x-ray absorption spectroscopy and resonant inelastic x-ray scattering (RIXS). We show that while conventional techniques remain powerful for probing the chemical species on the surface, today’s material research studies have triggered much more demanding chemical sensitivity that could only be offered by advanced techniques such as RIXS. Another direction in the field is the rapid development of various in situ/operando characterizations of complex electrochemical systems. Notably, the solid-state battery systems provide unique advantages for future studies of both the surface/interface and the bulk properties under operando conditions. We conclude with perspectives on the bright future of studying electrochemical systems through these advanced soft x-ray spectroscopic techniques.

25 ENERGY STORAGE↗

Comparison of excitation temperature of a laser-produced plasma by combining emission and absorption spectroscopy

Measurement of the temporal evolution of laser-produced plasma temperature is very important for many of its applications, and several plasma diagnostic tools are routinely used by researchers. However, it is very challenging to measure the properties of the plasma at the early and late times of its evolution using a single diagnostic tool. In this study, we combined emission and laser absorption spectroscopy to compare the excitation temperatures of a laser-produced uranium plasma system. Several U I transitions in the near-infrared spectral range (775–800 nm) were considered, and the Boltzmann plot method was used to measure the excitation temperatures using both emission and absorption spectroscopy. Emission spectroscopy provided early-time temperature measurements of the plasma up to times 2–20 µs, while absorption spectroscopy provided temperature measurements at late times of plasma evolution (for times 5–80 µs). The emission and absorbance of U I transitions were found to follow the Boltzmann distribution, indicating the plasma is likely in the state of local thermodynamic equilibrium even at late times of its lifetime. The emission and absorption-based time-resolved excitation temperatures demonstrated good agreement at earlier times (≤15 µs) in the overlapped temporal region, while a deviation in the measured values was seen at times (≥15 µs), and potential reasons for such a disagreement are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Inner Shell Spectroscopy beamline at NSLS-II: a facility for in situ and operando X-ray absorption spectroscopy for materials research

The Inner Shell Spectroscopy (ISS) beamline on the 8-ID station at the National Synchrotron Light Source II (NSLS-II), Upton, NY, USA, is a high-throughput X-ray absorption spectroscopy beamline designed for in situ, operando, and time-resolved material characterization using high monochromatic flux and scanning speed. This contribution discusses the technical specifications of the beamline in terms of optics, heat load management, monochromator motion control, and data acquisition and processing. Results of the beamline tests demonstrating the quality of the data obtainable on the instrument, possible energy scanning speeds, as well as long-term beamline stability are shown. The ability to directly control the monochromator trajectory to define the acquisition time for each spectral region is highlighted. Examples of studies performed on the beamline are presented. The paper is concluded with a brief outlook for future developments.

36 MATERIALS SCIENCE↗

White-line evolution in shocked solid Ta evidenced by synchrotron x-ray absorption spectroscopy

Time-resolved x-ray absorption experiments have been performed on shocked tantalum. Using a single 100 ps synchrotron x-ray pulse, nanosecond-lived equilibrium states of shocked solid Ta have been measured by L 3 -edge absorption spectroscopy. The energy shift and intensity change of the white line were measured up to 130 GPa and 2000 K. The experimental results are discussed in light of density functional theory calculations and FEFF simulations. Lastly, the absence of occurrence of the hcp-ω phase is suggested from the analysis of the shape of the white line.